Argosy Research H200 Series manual
- Consulta online o descarga el manual de instrucciones
- 13 páginas
- 2.3 mb
Ir a la página of
manuales de instrucciones parecidos
-
Water System
Argosy Research H200HF Series
13 páginas 2.3 mb -
Water System
Argosy Research WaterMate 3
2 páginas 0.58 mb -
Water System
Argosy Research H-125 Series
40 páginas 2.6 mb -
Water System
Argosy Research Series H-100
2 páginas 0.49 mb -
Water System
Argosy Research NF 1.5" Series
2 páginas 0.13 mb -
Water System
Argosy Research H200 Series
13 páginas 2.3 mb
Buen manual de instrucciones
Las leyes obligan al vendedor a entregarle al comprador, junto con el producto, el manual de instrucciones Argosy Research H200 Series. La falta del manual o facilitar información incorrecta al consumidor constituyen una base de reclamación por no estar de acuerdo el producto con el contrato. Según la ley, está permitido adjuntar un manual de otra forma que no sea en papel, lo cual últimamente es bastante común y los fabricantes nos facilitan un manual gráfico, su versión electrónica Argosy Research H200 Series o vídeos de instrucciones para usuarios. La condición es que tenga una forma legible y entendible.
¿Qué es un manual de instrucciones?
El nombre proviene de la palabra latina “instructio”, es decir, ordenar. Por lo tanto, en un manual Argosy Research H200 Series se puede encontrar la descripción de las etapas de actuación. El propósito de un manual es enseñar, facilitar el encendido o el uso de un dispositivo o la realización de acciones concretas. Un manual de instrucciones también es una fuente de información acerca de un objeto o un servicio, es una pista.
Desafortunadamente pocos usuarios destinan su tiempo a leer manuales Argosy Research H200 Series, sin embargo, un buen manual nos permite, no solo conocer una cantidad de funcionalidades adicionales del dispositivo comprado, sino también evitar la mayoría de fallos.
Entonces, ¿qué debe contener el manual de instrucciones perfecto?
Sobre todo, un manual de instrucciones Argosy Research H200 Series debe contener:
- información acerca de las especificaciones técnicas del dispositivo Argosy Research H200 Series
- nombre de fabricante y año de fabricación del dispositivo Argosy Research H200 Series
- condiciones de uso, configuración y mantenimiento del dispositivo Argosy Research H200 Series
- marcas de seguridad y certificados que confirmen su concordancia con determinadas normativas
¿Por qué no leemos los manuales de instrucciones?
Normalmente es por la falta de tiempo y seguridad acerca de las funcionalidades determinadas de los dispositivos comprados. Desafortunadamente la conexión y el encendido de Argosy Research H200 Series no es suficiente. El manual de instrucciones siempre contiene una serie de indicaciones acerca de determinadas funcionalidades, normas de seguridad, consejos de mantenimiento (incluso qué productos usar), fallos eventuales de Argosy Research H200 Series y maneras de solucionar los problemas que puedan ocurrir durante su uso. Al final, en un manual se pueden encontrar los detalles de servicio técnico Argosy Research en caso de que las soluciones propuestas no hayan funcionado. Actualmente gozan de éxito manuales de instrucciones en forma de animaciones interesantes o vídeo manuales que llegan al usuario mucho mejor que en forma de un folleto. Este tipo de manual ayuda a que el usuario vea el vídeo entero sin saltarse las especificaciones y las descripciones técnicas complicadas de Argosy Research H200 Series, como se suele hacer teniendo una versión en papel.
¿Por qué vale la pena leer los manuales de instrucciones?
Sobre todo es en ellos donde encontraremos las respuestas acerca de la construcción, las posibilidades del dispositivo Argosy Research H200 Series, el uso de determinados accesorios y una serie de informaciones que permiten aprovechar completamente sus funciones y comodidades.
Tras una compra exitosa de un equipo o un dispositivo, vale la pena dedicar un momento para familiarizarse con cada parte del manual Argosy Research H200 Series. Actualmente se preparan y traducen con dedicación, para que no solo sean comprensibles para los usuarios, sino que también cumplan su función básica de información y ayuda.
Índice de manuales de instrucciones
-
Página 1
H200 & H200HF SERIES W A TER CONDITIONERS Apartment Buildings Boiler W ater T reatment Car W ashes Commercial Buildings Condominiums Factories Hospitals Laundries Mobile Home Parks Motels and Hotels Nursing and Rest Homes Ofce Buildings Restaurants Schools For Commer cial & Industrial Applications H200 T op Mount H200 Side Mount H200HF S[...]
-
Página 2
Hellenbrand Means Quality and Reliability Since 1967, Hellenbrand, Inc. has provided water solutions to the water tr eatment industry in the U.S. and around the world. Our gr owth in the water tr eatment industry is a direct r esult of pro- viding high quality products and supporting the applications for those pr oducts with over 200+ years of indu[...]
-
Página 3
• Solid state micropr ocessor can control fr om one to four units allowing you system add on capabilities as your needs grow . • Regeneration may be initiated with a time clock, meter delayed or meter immediate. • Up to nine fully programmable cycle times, that can be moved around and r epeated in various orders for your particular applicatio[...]
-
Página 4
H200/H200HF Diagnostic and Histor y Screens provide the water treatment operator with a wealth of information. Diagnostic Screens • Days since last regeneration • T otal volume treated since last regeneration • Reserve history for the current day and previous six-days • Usage history by the hour for each of the last 63 days • Maximum o[...]
-
Página 5
H200/H200HF Diagnostic and Histor y Screens provide the water treatment operator with a wealth of information. DIAGNOSTIC 5 DIAGNOSTIC 6 DIAGNOSTIC 7 DIAGNOSTIC 7-B WS2H Control V alve Manual Page 21 Diagnostic Screens (continued) DIAGNOSTICS 5 Maximum fl ow rate for the last 28 days. Max fl ow rate of the day DIAGNOSTICS 5-B Hourly history of ma[...]
-
Página 6
H200/H200HF Diagnostic and Histor y Screens provide the water treatment operator with a wealth of information. HISTOR Y 1 HISTOR Y 2 HISTOR Y 3 Page 22 WS2H Control V alve Manual V alve History Returns to normal operation after 5 minutes. Accessed by pressing UP and DOWN simultaneously for >3 seconds, then by pressing UP and DOWN simultaneously [...]
-
Página 7
Modes of Regeneration Time Clock - 7 or 28 day calendar clock shall initiate regeneration at a pr e-set time of day . Parallel Individual Meters - All units are in service at the same time with either delayed or immediate r e- generation. A lockout feature or of fsetting time of regeneration pr events more than one unit to r egenerate at a time. Un[...]
-
Página 8
A . MINERAL T ANK: Fiberglass tank with Polyethylene Inner Shell and Fiberglass Roving Manufactured to Operate at 150 psi. NSF Approved. B. DISTRIBUTOR SYSTEM: T wo-Inch Hub & Lateral Dis - tributor for Maximum Service Flow and Minimal Pressure Loss. C. MINERAL: High Capacity Ion Exchange Resin. Uniform and stable beads assure long life, high s[...]
-
Página 9
Brine T ank(s) Inlet Bypass V alve Brine T ank(s) Outlet Isolation V alves Flex Connectors MA V V alve H200 T win/T riple x/Fourple x Installation T op-Mount - First-in, Last-Out Piping Arrangement. H200 Single Installation - Side Mount Brine T ank Inlet Outlet Bypass V alve Isolation V alves Sidemount Adapter Base Brine Line 1" MNPT 2” FNPT[...]
-
Página 10
H200 T win Alternating - Side Mount H200 T win/T riple x/Fourple x Installation - Side Mount First-in, Last-Out Piping Arrangement. Brine T ank See NOTE Figure 7 Figure 6 Brine T ank(s) Figure 7 NOTE: System connections to the tank must accommodate longitudinal movement between side, top and bot- tom openings, exibility in piping or ex connec[...]
-
Página 11
H200 HF Single T ank Installation H200 HF T win Alternating Installation H200 HF T riple x/Fourple x Installation Brine T ank See NOTE Figure 7 Figure 8 See NOTE Figure 7 Figure 9 See NOTE Figure 7 Figure 10 Outlet Meter High Flow Service V alve 1 Bypass V alve Inlet Outlet is Plugged High Flow Service V alve Pipe is on an angle Isolation V alve 1 [...]
-
Página 12
RECOMMENDED BRINE T ANK APPROXIMA TE PIPE SIZE MINERAL T ANK SIZE SAL T STORAGE SHIPPING WEIGHT -TOP MOUNT MODEL (INCHES) (INCHES) (INCHES) ( LBS) SINGLE TWIN H200-240 2 24 X 72 24 X 50 715 674 1325 H200-300-24 2 24 X 72 24 X 50 715 776 1529 H200-300-30 2 30 X 72 30 X 50 1,1 10 1059 2064 H200-450-30 2 30 X 72 39 X 48 2,030 1333 2593 H200-450-36 2 3[...]
-
Página 13
RA TED CAP ACITY FLOW RA TES (gpm) RESIN LOW SAL T MEDIUM SAL T HIGH SAL T BKW MODEL CU.FT . GRAINS/LBS GRAINS/LBS GRAINS/LBS 15 PSI 25 PSI GPM H200HF-300-24-3 10 190,000/60 280,000/100 320,000/150 120 170 12 H200HF-300-30-3 10 190,000/60 280,000/100 320,000/150 175 225 20 H200HF-450-30-3 15 285,000/90 420,000/150 480,000/225 158 212 20 H200HF-450-[...]