Contemporary Research AV6X4 manual
- Consulta online o descarga el manual de instrucciones
- 14 páginas
- 0.37 mb
Ir a la página of
manuales de instrucciones parecidos
-
Switch
Contemporary Research EISK8-100T Series
4 páginas 0.29 mb -
Universal Remote
Contemporary Research ICC2-IRC
22 páginas 0.37 mb -
TV Receiver
Contemporary Research ICC2-ATSC
23 páginas 0.81 mb -
Stereo Receiver
Contemporary Research AV6X4
14 páginas 0.37 mb -
TV Receiver
Contemporary Research IP-HDVR
38 páginas 1.08 mb -
Network Hardware
Contemporary Research ICC/ICW-HE
2 páginas 0.15 mb -
Switch
Contemporary Research MOD HUB series
8 páginas 0.03 mb -
MP3 Player
Contemporary Research IP-HDTV
30 páginas 0.95 mb
Buen manual de instrucciones
Las leyes obligan al vendedor a entregarle al comprador, junto con el producto, el manual de instrucciones Contemporary Research AV6X4. La falta del manual o facilitar información incorrecta al consumidor constituyen una base de reclamación por no estar de acuerdo el producto con el contrato. Según la ley, está permitido adjuntar un manual de otra forma que no sea en papel, lo cual últimamente es bastante común y los fabricantes nos facilitan un manual gráfico, su versión electrónica Contemporary Research AV6X4 o vídeos de instrucciones para usuarios. La condición es que tenga una forma legible y entendible.
¿Qué es un manual de instrucciones?
El nombre proviene de la palabra latina “instructio”, es decir, ordenar. Por lo tanto, en un manual Contemporary Research AV6X4 se puede encontrar la descripción de las etapas de actuación. El propósito de un manual es enseñar, facilitar el encendido o el uso de un dispositivo o la realización de acciones concretas. Un manual de instrucciones también es una fuente de información acerca de un objeto o un servicio, es una pista.
Desafortunadamente pocos usuarios destinan su tiempo a leer manuales Contemporary Research AV6X4, sin embargo, un buen manual nos permite, no solo conocer una cantidad de funcionalidades adicionales del dispositivo comprado, sino también evitar la mayoría de fallos.
Entonces, ¿qué debe contener el manual de instrucciones perfecto?
Sobre todo, un manual de instrucciones Contemporary Research AV6X4 debe contener:
- información acerca de las especificaciones técnicas del dispositivo Contemporary Research AV6X4
- nombre de fabricante y año de fabricación del dispositivo Contemporary Research AV6X4
- condiciones de uso, configuración y mantenimiento del dispositivo Contemporary Research AV6X4
- marcas de seguridad y certificados que confirmen su concordancia con determinadas normativas
¿Por qué no leemos los manuales de instrucciones?
Normalmente es por la falta de tiempo y seguridad acerca de las funcionalidades determinadas de los dispositivos comprados. Desafortunadamente la conexión y el encendido de Contemporary Research AV6X4 no es suficiente. El manual de instrucciones siempre contiene una serie de indicaciones acerca de determinadas funcionalidades, normas de seguridad, consejos de mantenimiento (incluso qué productos usar), fallos eventuales de Contemporary Research AV6X4 y maneras de solucionar los problemas que puedan ocurrir durante su uso. Al final, en un manual se pueden encontrar los detalles de servicio técnico Contemporary Research en caso de que las soluciones propuestas no hayan funcionado. Actualmente gozan de éxito manuales de instrucciones en forma de animaciones interesantes o vídeo manuales que llegan al usuario mucho mejor que en forma de un folleto. Este tipo de manual ayuda a que el usuario vea el vídeo entero sin saltarse las especificaciones y las descripciones técnicas complicadas de Contemporary Research AV6X4, como se suele hacer teniendo una versión en papel.
¿Por qué vale la pena leer los manuales de instrucciones?
Sobre todo es en ellos donde encontraremos las respuestas acerca de la construcción, las posibilidades del dispositivo Contemporary Research AV6X4, el uso de determinados accesorios y una serie de informaciones que permiten aprovechar completamente sus funciones y comodidades.
Tras una compra exitosa de un equipo o un dispositivo, vale la pena dedicar un momento para familiarizarse con cada parte del manual Contemporary Research AV6X4. Actualmente se preparan y traducen con dedicación, para que no solo sean comprensibles para los usuarios, sino que también cumplan su función básica de información y ayuda.
Índice de manuales de instrucciones
-
Página 1
17630 Davenport Rd, Suite113 Dallas, TX 75252 USA Tel: 972.931.2728 888.972.2728 Fax: 972.931-2765 Web: www.crwww.com www.contemporaryresearch.com Product Manual AV6x4 Audio/Video Router, 6x4 January 14, 2003[...]
-
Página 2
Contemporary Research Corporation 2 AV6x4 A/V Router Table of Contents Overview ....................................................................................................................... ...................... 3 Specifications ..............................................................................................................[...]
-
Página 3
Contemporary Research Corporation 3 AV6x4 A/V Router Overview Contemporary Research presents the AV6x4, a flex ible, controllable matrix switcher for routing six stereo A/V inputs to four stereo A/V outputs. Using the simplified front-panel controls, it's easy to switch VCRs, DVDs CDs, cameras and other sources to TVs, projectors, and plasma d[...]
-
Página 4
Contemporary Research Corporation 4 AV6x4 A/V Router Specifications Physical Size: 19" [483mm] wide x 1.75" [38mm] height (1RU) x 9.25" [235mm] deep Weight: 4.25lbs [1.47Kg] Enclosure: All aluminum, including front ex trusion, durable black powder coat paint Front Panel Mute All A/V: Toggling Mute for all audio and video, red LED lig[...]
-
Página 5
Contemporary Research Corporation 5 AV6x4 A/V Router Front Panel Programming To Enter a Front Panel Programming Mode 1. Press and hold the Mute A/V button until the red LED light above is lit (indicating Mute On). 2. Press Input 1-6 in the Output A/C section to select Programming Mode 1-6. The Mode and Output A-D LEDs (yellow) will tu rn off when p[...]
-
Página 6
Contemporary Research Corporation 6 AV6x4 A/V Router Front Panel Programming Quick Reference Mode Function A/C Parameter B/D Parameter 1 Baud Rate 1 300 2 600 3 1200 4 2400 5 4800 6 9600 (default 2 Unit Number 1 Unit 1 2 Unit 2 3 Unit 3 3 Input Level 1 Input 1 1 -9 dB 2 Input 2 2 -6 dB 3 Input 3 3 -3 dB 4 Input 4 4 +3 dB 5 Input 5 5 +6 dB 6 Input 6[...]
-
Página 7
Contemporary Research Corporation 7 AV6x4 A/V Router RS-232 Control Protocol Overview The AV6x4 full-duplex RS-232 scheme enables a system programmer to control all routing functions as well as monitor 3 groups of unit status. All commands are sent as ASCII strings. No delays between characters or commands are required, as data is interrupt driven [...]
-
Página 8
Contemporary Research Corporation 8 AV6x4 A/V Router RS-232 Commands Crosspoint Commands A Crosspoint command sends inputs to ou tputs. The command structure is simple: > [Unit] [Crosspoint (X, A, V)] [Input (0-6)] [Output (A-D)] [Input] [Output]… More than one set of Input/Output points can follow th e Crosspoint command. You don’t have to [...]
-
Página 9
Contemporary Research Corporation 9 AV6x4 A/V Router Audio Gain Commands An Audio Gain command adjusts the attenuation or gain of each Input. > [Unit] [Gain] [Input (1-6)] [Level (1-6)] [Input] [Level]… More than one set of Input/Gain pairs can follow the Ga in command. You don’t have to include all Input/Gain pairs in the string, only the o[...]
-
Página 10
Contemporary Research Corporation 10 AV6x4 A/V Router Front Panel Commands Front Panel Commands emulate the functions of front-panel operation and programming. > [Unit] [Panel] [Mode] [Output A/C] [Output B/D] [Lockout] All four parameters (Mode, Output A/C, Output B/D, Lockout) must be included in string. A carriage return is required at the en[...]
-
Página 11
Contemporary Research Corporation 11 AV6x4 A/V Router Response Strings Typical: [Attention] [Unit#] [data ...data] [cr] [lf] AV6x4status response strings contain ASCII characters similar to those used for the same functions in command strings. An ASCII 'carriage return' and ‘line feed' follow each response string. Crosspoint Status[...]
-
Página 12
Contemporary Research Corporation 12 AV6x4 A/V Router RS-232 Cable Connections All drawings show pin numbers relative to a PC COM port or Axcent3 DB-9 RS-232 control port. Pin-outs to other types of control ports may vary. Single Unit 5 GND 2 RXD 3 TXD RXD 2 GND 5 TXD 3 RS-232 Wiring – Single Unit 9-pin D-su b female RS-232 Control Por t Multiple[...]
-
Página 13
Contemporary Research Corporation 13 AV6x4 A/V Router Safety Instructions Read before operating equipment. 1. Cleaning - Unplug this product from the wall outlet before cleaning. Do not use liquid cleaners or aerosol cleaners. Use a damp cloth for cleaning. 2. Power Sources - Use supplied or equivalent UL/CSA approved low voltage DC plug-in transfo[...]
-
Página 14
Contemporary Research Corporation 14 AV6x4 A/V Router Limited Warranty and Disclaimer Contemporary Research Corporation (CR) warrant s this product to be free from defects in material and workmanship under normal use fo r a period of two years from the date of purchase from CR. Should such a defect occur CR will repair or replace, at their option, [...]