Empire Comfort Systems 21)L(N manual
- Consulta online o descarga el manual de instrucciones
- 28 páginas
- 1.93 mb
Ir a la página of
manuales de instrucciones parecidos
-
Indoor Fireplace
Empire Comfort Systems DVP42FP7(0,1,2,3)(N,P)-1
56 páginas 3.59 mb -
Indoor Fireplace
Empire Comfort Systems DVD42FP5
52 páginas 4.12 mb -
Indoor Fireplace
Empire Comfort Systems VFD36FB0L-1
20 páginas 4.96 mb -
Indoor Fireplace
Empire Comfort Systems DVP48FP3(0,1,2,3)(N,P)-1
56 páginas 3.59 mb -
Indoor Fireplace
Empire Comfort Systems VFHS-20R-4
28 páginas 2.84 mb -
Indoor Fireplace
Empire Comfort Systems P)-1
28 páginas 1.93 mb -
Indoor Fireplace
Empire Comfort Systems VFP32FPL-1, VFP32FPL-1, VFP36FPL-1, VFP36FPL-1
28 páginas 1.91 mb -
Indoor Fireplace
Empire Comfort Systems VFD32FB0L-1
20 páginas 4.96 mb
Buen manual de instrucciones
Las leyes obligan al vendedor a entregarle al comprador, junto con el producto, el manual de instrucciones Empire Comfort Systems 21)L(N. La falta del manual o facilitar información incorrecta al consumidor constituyen una base de reclamación por no estar de acuerdo el producto con el contrato. Según la ley, está permitido adjuntar un manual de otra forma que no sea en papel, lo cual últimamente es bastante común y los fabricantes nos facilitan un manual gráfico, su versión electrónica Empire Comfort Systems 21)L(N o vídeos de instrucciones para usuarios. La condición es que tenga una forma legible y entendible.
¿Qué es un manual de instrucciones?
El nombre proviene de la palabra latina “instructio”, es decir, ordenar. Por lo tanto, en un manual Empire Comfort Systems 21)L(N se puede encontrar la descripción de las etapas de actuación. El propósito de un manual es enseñar, facilitar el encendido o el uso de un dispositivo o la realización de acciones concretas. Un manual de instrucciones también es una fuente de información acerca de un objeto o un servicio, es una pista.
Desafortunadamente pocos usuarios destinan su tiempo a leer manuales Empire Comfort Systems 21)L(N, sin embargo, un buen manual nos permite, no solo conocer una cantidad de funcionalidades adicionales del dispositivo comprado, sino también evitar la mayoría de fallos.
Entonces, ¿qué debe contener el manual de instrucciones perfecto?
Sobre todo, un manual de instrucciones Empire Comfort Systems 21)L(N debe contener:
- información acerca de las especificaciones técnicas del dispositivo Empire Comfort Systems 21)L(N
- nombre de fabricante y año de fabricación del dispositivo Empire Comfort Systems 21)L(N
- condiciones de uso, configuración y mantenimiento del dispositivo Empire Comfort Systems 21)L(N
- marcas de seguridad y certificados que confirmen su concordancia con determinadas normativas
¿Por qué no leemos los manuales de instrucciones?
Normalmente es por la falta de tiempo y seguridad acerca de las funcionalidades determinadas de los dispositivos comprados. Desafortunadamente la conexión y el encendido de Empire Comfort Systems 21)L(N no es suficiente. El manual de instrucciones siempre contiene una serie de indicaciones acerca de determinadas funcionalidades, normas de seguridad, consejos de mantenimiento (incluso qué productos usar), fallos eventuales de Empire Comfort Systems 21)L(N y maneras de solucionar los problemas que puedan ocurrir durante su uso. Al final, en un manual se pueden encontrar los detalles de servicio técnico Empire Comfort Systems en caso de que las soluciones propuestas no hayan funcionado. Actualmente gozan de éxito manuales de instrucciones en forma de animaciones interesantes o vídeo manuales que llegan al usuario mucho mejor que en forma de un folleto. Este tipo de manual ayuda a que el usuario vea el vídeo entero sin saltarse las especificaciones y las descripciones técnicas complicadas de Empire Comfort Systems 21)L(N, como se suele hacer teniendo una versión en papel.
¿Por qué vale la pena leer los manuales de instrucciones?
Sobre todo es en ellos donde encontraremos las respuestas acerca de la construcción, las posibilidades del dispositivo Empire Comfort Systems 21)L(N, el uso de determinados accesorios y una serie de informaciones que permiten aprovechar completamente sus funciones y comodidades.
Tras una compra exitosa de un equipo o un dispositivo, vale la pena dedicar un momento para familiarizarse con cada parte del manual Empire Comfort Systems 21)L(N. Actualmente se preparan y traducen con dedicación, para que no solo sean comprensibles para los usuarios, sino que también cumplan su función básica de información y ayuda.
Índice de manuales de instrucciones
-
Página 1
Page 1 20101-0-0306 INST ALLA TION INSTRUCTIONS AND OWNER'S MANUAL UNVENTED GAS FIREPLACE MODELS VFP32FP(20,21)L(N,P)-1 VFP32FP(30,31)L(N,P)-1 VFP36FP(20,21)L(N,P)-1 VFP36FP(30,31)L(N,P)-1 EFFECTIVE DA TE MARCH 2006 — Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. — WHA T[...]
-
Página 2
Page 2 20101-0-0306 SECTION P AGE Important Safety Information ................................................................................................. 3 Safety Information for Users of LP Gas ................................................................................. 4 Introduction ...................................................[...]
-
Página 3
Page 3 20101-0-0306 Wh en us e d wi th out a deq ua te co mbu sti on an d ve nti lat i on air , he ate r ma y gi ve o ff C ARB ON M ONO XID E, a n od orl ess , po iso nou s g as . Do not install heater until all necessary pr ovisions are made for combustion and ventilation air . Consult the written instructions provided with the heater for informat[...]
-
Página 4
Page 4 20101-0-0306 Some people cannot smell well. Some people cannot smell the odor of the chemical put into the gas. Y ou must find out if you can smell the odorant in propane. Smoking can decrease your ability to smell. Being around an odor for a time can affect your sensitivity or ability to detect that odor . Sometimes other odors in the area[...]
-
Página 5
Page 5 20101-0-0306 Instructions to Installer 1. Installer must leave instruction manual with owner after installation. 2. Installer must have owner fill out and mail warranty card supplied with unvented room heater . 3. Installer should show owner how to start and operate unvented room heater . Always consult your local Building Department regard[...]
-
Página 6
Page 6 20101-0-0306 Model VFP32FP VFP36FP Input Maximum 32,000 36,000 Minimum 22,000 25,000 Minimum Firebox Opening Height without standoff 32 3/4" 34 3/4" W idth 34” 39” Depth 17 3/8" 17 3/8” Gas Inlet 3/8” 3/8” Accessories EK-1 Embers Kit PE-20 Platinum Embers FBB4* V ariable Speed Automatic Blower VPP32A VFP32FP — Cera[...]
-
Página 7
Page 7 20101-0-0306 W ater vapor is a by-product of gas combustion. An unvented room heater produces approximately one (1) ounce (30ml) of water for every 1,000 BTU's (.3KW's) of gas input per hour . Unvented room heaters are recommended as supplemental heat (a room) rather than a primary heat source (an entire house). In most supplementa[...]
-
Página 8
Page 8 20101-0-0306 The space in the above example is a confined space because the actual BTU/Hr used is more than the maximum BTU/HR the space can support. Y ou must provide additional fresh air . Y our options are as follows: A. Rework worksheet, adding the space of an adjoining room. If the extra space provides an unconfined space, remove door[...]
-
Página 9
Page 9 20101-0-0306 Check all local codes for requirements, especially for the size and type of gas supply line required. Recommended Gas Pipe Diameter Pipe Length Schedule 40 Pipe Inside Diameter T ubing, T ype L Outside Diameter Nat. L.P . Nat. L.P . 0-10 feet 0-3 meters 1/2” 12.7mm 3/8” 9.5mm 1/2” 12.7mm 3/8” 9.5mm 10-40 feet 4-12 meters[...]
-
Página 10
Page 10 20101-0-0306 M in i mu m Wa l l a n d Ce i l in g C l e ar an c e s (Figure 4) Sid ewal l Clea ran ces: The clear ance from the inside of the firep lac e to any combustible wall should not be less than 2". Fireplace Side and Back Clearances: The fireplace outer casing sides and back have zero clearance to combustibles. Ceiling Cleara[...]
-
Página 11
Page 1 1 20101-0-0306 Do not attach combustible material to the mantel of your fireplace. This is a fire hazard. Figure 6 No greeting cards, stockings or ornamentation of any type should be placed o n or attache d to the firep lace. This is a heating ap pliance. The flow of heat can ignite combustibles. Figure 7 COMBUSTIBLE MA TERIALS[...]
-
Página 12
Page 12 20101-0-0306 JUNCTION BOX ASSEMBL Y C Figure 8 VFP32FP VFP36FP A 34" 39" B 29" 34" C 17 3/8" 17 3/8" D 31" 36" E 22 7/8" 24 7/8" F 32 3/4" 34 3/4" G 44 7/16" 48" H 44 7/16" 48" I 55 7/8" 60 7/8" J 35 3/4" 37 3/4" FIREPLACE DIMENSIONS[...]
-
Página 13
Page 13 20101-0-0306 A black hood and trim kit is furnished with each model VFP(32,36)FP fireplace. The hood MUST be installed before the firepl ace is used. Failu re to do so may create a possibl e fire hazard. Atten tion: The hood is located behind top louver duri ng shipmen t of fireplace. Remove top louver for access to hood. The trim kit i[...]
-
Página 14
Page 14 20101-0-0306 1. Place fireplace in framing opening. 2. Using the four (4) nailing flanges provided with the fireplace, attach two (2) flanges on each side. Attach flanges through prepunched holes. Additional hole locations will be used for different finishing material with thicknesses of 1/2”, 5/8” and 3/4”. Attach these flange[...]
-
Página 15
Page 15 20101-0-0306 Placement of the glowing embers (rock wool) is very individual and light coverage of the areas indicated will provide your best effects. W e recommend separation of the rock wool by hand and make your coverage as light and fluffy as possible. Place just enough embers on the burner to obtain the glow and a gold yellow flame. D[...]
-
Página 16
Page 16 20101-0-0306 Flames from the pilot (rear right back side of the pan burner) as well as the main flame should be visually checked as the log set is installed. In normal operation at full rate after 10 to 15 minutes, the flame appearance should be sets of yellow flames. NOTE: All flames will be random by design, flame height will go up a[...]
-
Página 17
Page 17 20101-0-0306 W ARNING: If you do not follow these instructions exactly , a fire or explosion may r esult causing property damage, personal injury or loss of life. A. This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly . B. BEFORE LIGHTING smell all around the appliance ar ea [...]
-
Página 18
Page 18 20101-0-0306 W ARNING: If you do not follow these instructions exactly , a fire or explosion may r esult causing property damage, personal injury or loss of life. A. This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly . B. BEFORE LIGHTING smell all around the appliance area f[...]
-
Página 19
Page 19 20101-0-0306 Figures 13 and 15 show a correct pilot flame pattern. The correct flame will be blue and will extend beyond the thermocouple. The flame will surround the thermocouple just below the tip. A slight yellow flame may occur where the pilot flame and main burner flame meet. Figures 14 a nd 16 show an incorrect p ilot flame pa [...]
-
Página 20
Page 20 20101-0-0306 Figure 17 W arning: Never use needles, wir es, or similar cylindrical objects to clean the pilot to avoid damaging the calibrated ruby that controls the gas flow . Cleaning and Pilot Maintenance Oxygen Depletion Sensor Pilot (Figur e 17) When the pilot has a large yellow tip flame, clean the Oxygen Depletion Sensor as follows[...]
-
Página 21
Page 21 20101-0-0306 If the gas quality is bad, your pilot may not stay lit, the burners may produce soot and the heater may backfire when lit. If the gas quality or pr essure is low , contact your local gas supplier immediately . 1. When ignitor button is pressed, there is no spark at ODS/ pilot. a. Ignitor electrode positioned wrong - Replace pi[...]
-
Página 22
Page 22 20101-0-0306 USE ONL Y MANUF ACTURER'S REPLACEMENT P AR TS. USE OF ANY OTHER P AR TS COULD CAUSE INJUR Y OR DEA TH. NOTE: SEE LOG INSTRUCTION MANUAL FOR DET AILS ON LOGS AND EMBERS A TTENTION: When ordering parts, it is very important that part number and description of part coincide. P AR TS LIST Index Number Part Number VFP32FP(20,21[...]
-
Página 23
Page 23 20101-0-0306 Parts can be ordered only through your service person or dealer . For best results, the service person or dealer should order parts through the distributor . Parts can be shipped directly to the service person/dealer . All parts listed in the Parts List have a Part Number. When ordering parts, first obtain the Model Number fro[...]
-
Página 24
Page 24 20101-0-0306 FBB4 Blower Installation Attention: Install blower assembly before connecting gas inlet supply line. Note: Junction box on right side of fireplace must be pre- wired at time of fireplace installation for use with blower assembly . It is recommended that an ON/OFF wall switch be installed that will activate the power supply to[...]
-
Página 25
Page 25 20101-0-0306 Wiring The appliance, when installed, must be electrically grounded in accordance with local codes or , in the absence of local codes, with the National Electrical Code, ANSI/NFP A 70 , if an external electrical source is utilized. This appliance is equipped with a three-pr ong [grounding] plug for your protection against shock[...]
-
Página 26
Page 26 20101-0-0306 CAUTION: ALL WIRING SHOULD BE DONE BY A QUALIFIED ELECTRICIAN AND SHALL BE IN COMPLIANCE WITH ALL LOCAL, CITY AND ST A TE BUILDING CODES. BEFORE MAKING THE ELECTRICAL CONNECTION, MAKE SURE THA T MAIN POWER SUPPL Y IS DISCONNECTED. THE APPLIANCE, WHEN INST ALLED, MUST BE ELECTRICALL Y GROUNDED IN ACCORDANCE WITH LOCAL CODES OR, [...]
-
Página 27
Page 27 20101-0-0306 SER VICE NOTES[...]
-
Página 28
Page 28 20101-0-0306 Empire Comfort Systems, Inc. 918 Freeburg A ve. Belleville, IL 62220 PH: 618-233-7420 or 800-851-3153 F AX: 618-233-7097 or 800-443-8648 info@empirecomfort.com www .empirecomfort.com[...]