Empire Comfort Systems FAW-40-1IP manual
- Consulta online o descarga el manual de instrucciones
- 18 páginas
- 0.74 mb
Ir a la página of
manuales de instrucciones parecidos
-
Furnace
Empire Comfort Systems DV-55E-5
20 páginas 1.01 mb -
Furnace
Empire Comfort Systems DV-20E-5
20 páginas 1.32 mb -
Furnace
Empire Comfort Systems DV-215-7SG
20 páginas 0.7 mb -
Furnace
Empire Comfort Systems RB)
20 páginas 1.11 mb -
Furnace
Empire Comfort Systems GWT-50-2
20 páginas 1.11 mb -
Furnace
Empire Comfort Systems FAW-55SPP
12 páginas 0.82 mb -
Furnace
Empire Comfort Systems FAW-40-1SPP
18 páginas 0.74 mb -
Furnace
Empire Comfort Systems 7088-3
12 páginas 0.17 mb
Buen manual de instrucciones
Las leyes obligan al vendedor a entregarle al comprador, junto con el producto, el manual de instrucciones Empire Comfort Systems FAW-40-1IP. La falta del manual o facilitar información incorrecta al consumidor constituyen una base de reclamación por no estar de acuerdo el producto con el contrato. Según la ley, está permitido adjuntar un manual de otra forma que no sea en papel, lo cual últimamente es bastante común y los fabricantes nos facilitan un manual gráfico, su versión electrónica Empire Comfort Systems FAW-40-1IP o vídeos de instrucciones para usuarios. La condición es que tenga una forma legible y entendible.
¿Qué es un manual de instrucciones?
El nombre proviene de la palabra latina “instructio”, es decir, ordenar. Por lo tanto, en un manual Empire Comfort Systems FAW-40-1IP se puede encontrar la descripción de las etapas de actuación. El propósito de un manual es enseñar, facilitar el encendido o el uso de un dispositivo o la realización de acciones concretas. Un manual de instrucciones también es una fuente de información acerca de un objeto o un servicio, es una pista.
Desafortunadamente pocos usuarios destinan su tiempo a leer manuales Empire Comfort Systems FAW-40-1IP, sin embargo, un buen manual nos permite, no solo conocer una cantidad de funcionalidades adicionales del dispositivo comprado, sino también evitar la mayoría de fallos.
Entonces, ¿qué debe contener el manual de instrucciones perfecto?
Sobre todo, un manual de instrucciones Empire Comfort Systems FAW-40-1IP debe contener:
- información acerca de las especificaciones técnicas del dispositivo Empire Comfort Systems FAW-40-1IP
- nombre de fabricante y año de fabricación del dispositivo Empire Comfort Systems FAW-40-1IP
- condiciones de uso, configuración y mantenimiento del dispositivo Empire Comfort Systems FAW-40-1IP
- marcas de seguridad y certificados que confirmen su concordancia con determinadas normativas
¿Por qué no leemos los manuales de instrucciones?
Normalmente es por la falta de tiempo y seguridad acerca de las funcionalidades determinadas de los dispositivos comprados. Desafortunadamente la conexión y el encendido de Empire Comfort Systems FAW-40-1IP no es suficiente. El manual de instrucciones siempre contiene una serie de indicaciones acerca de determinadas funcionalidades, normas de seguridad, consejos de mantenimiento (incluso qué productos usar), fallos eventuales de Empire Comfort Systems FAW-40-1IP y maneras de solucionar los problemas que puedan ocurrir durante su uso. Al final, en un manual se pueden encontrar los detalles de servicio técnico Empire Comfort Systems en caso de que las soluciones propuestas no hayan funcionado. Actualmente gozan de éxito manuales de instrucciones en forma de animaciones interesantes o vídeo manuales que llegan al usuario mucho mejor que en forma de un folleto. Este tipo de manual ayuda a que el usuario vea el vídeo entero sin saltarse las especificaciones y las descripciones técnicas complicadas de Empire Comfort Systems FAW-40-1IP, como se suele hacer teniendo una versión en papel.
¿Por qué vale la pena leer los manuales de instrucciones?
Sobre todo es en ellos donde encontraremos las respuestas acerca de la construcción, las posibilidades del dispositivo Empire Comfort Systems FAW-40-1IP, el uso de determinados accesorios y una serie de informaciones que permiten aprovechar completamente sus funciones y comodidades.
Tras una compra exitosa de un equipo o un dispositivo, vale la pena dedicar un momento para familiarizarse con cada parte del manual Empire Comfort Systems FAW-40-1IP. Actualmente se preparan y traducen con dedicación, para que no solo sean comprensibles para los usuarios, sino que también cumplan su función básica de información y ayuda.
Índice de manuales de instrucciones
-
Página 1
Page 1 INST ALLA TION INSTRUCTIONS AND OWNER'S MANUAL F AN TYPE VENTED W ALL FURNACE MODEL F A W -40-1SPP F A W -40-1IP W ARNING: If not installed, operated and maintained in accordance with the manu- facturer's instructions, this pr oduct could expose you to substances in fuel or fr om fuel combustion which can cause death or serious ill[...]
-
Página 2
Page 2 The base referred to above does not mean the fire-proof base as used on wood stoves. The protection is for rugs that are extremely thick and light colored tile. Installation in Residential Garages Gas utilization equipment in residential garages shall be installed so that all burners and burner ignition devices are located not less than 18&[...]
-
Página 3
Page 3 Some people cannot smell well. Some people cannot smell the odor of the chemical stench put into the gas. Y ou must find out if you can smell the odorant in propane. Smoking can decrease your ability to smell. Being around an odor for a time can affect your sensitivity or ability to detect that odor . Sometimes other odors in the area mask [...]
-
Página 4
Page 4 furnace opening confined� space Figure 1 Outdoor Air Outlet and inlet air can be brought into the confined space via openings into a ventilated attic and ventilated crawl space. f u rna c e o ut l e t a ir inl e t a ir a tt ic ve n til a ti o n l o u ve rs c r a wl s p a c e ve n ti l a ti o n l o u ve rs Figure 2 Confined Space Outdoor [...]
-
Página 5
Page 5 C. 4" (102mm) Oval In-The-W all (all parts purchase locally) 1. T ype B-1 oval pipe or B-W vent pipe 2. T ype B-1 oval elbows or B-W oval elbows 3. Single story type B-1 or (B-W) gas vents require a baseplate and one pair of ceiling plate spacers. 4. Multi-story type B-1 or (B-W) gas vents require a baseplate, one pair of ceiling plate [...]
-
Página 6
Page 6 Figure 5 Use U.L. listed gas vent equipment when installing the F A W -40. For vent pipe running through walls, roof, and within one (1) inch (25mm) of combustible construction, use B-1 or (B-W) [one inch (25mm) clearance to combustibles] vent pipe. T ype B-2 x 4 or T ype B-2 x 6 are to be used in conjunction with a Listed fire stop spacer [...]
-
Página 7
Page 7 #8 x 3/8" (9mm) screws provided. 8. Align clearance holes on 6" x 10" (152mm x 254mm) duct with screw holes on inner casing back and mark duct to be 2 1/4" (57mm) shorter than 8" x 12" (203mm x 305mm) boot. Remove duct and cut to proper length. 9. A t t a c h 6 " x 1 0 " (152mm x 254mm) duct to inner c[...]
-
Página 8
Page 8 Attention! If one of the above procedures results in pressures in excess of 1/2 psig (14" w .c.) (3.5 kPa) on the appliance gas valve, it will result in a hazardous condition. Checking Manifold Pressur e Both Propane and Natural gas valves have a built-in pressure regulator in the gas valve. Natural gas models will have a manifold press[...]
-
Página 9
Page 9 Oiling the Motor The fan motor should be cleaned and oiled once each heating season. Oil holes are located on the top at each end of the motor . Use a few drops of #10 motor oil. T o clean the motor, blow air through its ventilation openings with a vacuum cleaner or low pressure air source. Wiring The appliance, when installed, must be elect[...]
-
Página 10
Page 10 SER VICE AND MAINTENANCE SUGGESTIONS CALL SER VICEMAN GENERAL: All furnaces have been fire-tested to check for proper op- eration. This includes, main burner flame, pilot flame, fan operation, fan control, limit control and automatic valve operation. If the furnace fails to function on initial installation, it is advisable to re-check th[...]
-
Página 11
Page 1 1 FOR YOUR SAFETY READ BEFORE LIGHTING W ARNING: If you do not follow these instructions exactly , a fire or explosion may r esult causing property damage, personal injury or loss of life. A. This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly . B. BEFORE LIGHTING smell all ar[...]
-
Página 12
Page 12 FOR YOUR SAFETY READ BEFORE OPERA TING W ARNING: If you do not follow these instructions exactly , a fire or explosion may r esult causing property damage, personal injury or loss of life. A. This applian ce is equipped with an ignition device which automatically lights the pilot. Do not try to light the pilot by hand. B. BEFORE OPERA TING[...]
-
Página 13
Page 13 ST AR T System Check T rial for Ignition Main Burner Operation END Pilot V alve Opens Ignitor Powered Flame Signal Detected Thermostat Calls for Heat Ignitor OFF Main V alve Opens Internal Check OK Pilot Light and Flame is Sensed During Trial For Ignition (1) Apply 24 V AC T o Appliance Main Pilot V alves Close Thermostat Ca[...]
-
Página 14
Page 14 ST AR T IP SYSTEM TROUBLESHOOTING SEQUENCE T urn OFF Gas Supply Disconnect System Control Harness Set Thermostat to Call for Heat Check for Proper V oltage at Control Harness (See Inset A - V o l t a g e S h o u l d b e 2 4 V Between Thermostat and 24V Common, and 24V Between 24V Common and 24V Hot.) Plug Harness into SmartV alv[...]
-
Página 15
Page 15 I N D E X P A R T N O . N U M B E R D E S C R IP TI ON I N D E X P A R T N O . N U M B E R D ES CR IP TI ON PLEASE NOTE: When ordering parts, it is very important that part number and description of part coincide. 1 WF A-115 GASKET - HEADER 2 DV -1247 TOP PLA TE (USA) 2 15668 TOP PLA TE (CANADA) 3 R-3165 DOOR CLIP (2 REQUIRED) 4 DV -1204 CA[...]
-
Página 16
Page 16 12427-6-0707[...]
-
Página 17
Page 17 Service Notes 12427-6-0707[...]
-
Página 18
Page 18 Empire Comfort Systems, Inc. Nine Eighteen Freeburg A ve. Belleville, Illinois 62220-2623 PH: 1-618-233-7420 PH: 1-800-851-3153 F AX: 1-618-233-7097 F AX: 1-800-443-8648 E-MAIL: info@empirecomfort.com WEB SITE: www .empirecomfort.com 12427-6-0707[...]