Heat & Glo NorthStar-BK manual
- Consulta online o descarga el manual de instrucciones
- 72 páginas
- 11.91 mb
Ir a la página of
manuales de instrucciones parecidos
-
Indoor Fireplace
Heat & Glo PIER-40
52 páginas 3.18 mb -
Indoor Fireplace
Heat & Glo Cyclone-Cust
46 páginas 2.4 mb -
Indoor Fireplace
Heat & Glo ST-550TM-IPI
62 páginas 3 mb -
Indoor Fireplace
Heat & Glo Gas Fireplace ST-36TR
8 páginas 2.05 mb -
Indoor Fireplace
Heat & Glo Gas Logs For Woodburning Fireplaces Gas Logs
4 páginas 0.61 mb -
Indoor Fireplace
Heat & Glo Soho24B
53 páginas 2.58 mb -
Indoor Fireplace
Heat & Glo Twilight II
4 páginas 0.6 mb -
Indoor Fireplace
Heat & Glo Gas Fireplace SOULSTICE
4 páginas 0.72 mb
Buen manual de instrucciones
Las leyes obligan al vendedor a entregarle al comprador, junto con el producto, el manual de instrucciones Heat & Glo NorthStar-BK. La falta del manual o facilitar información incorrecta al consumidor constituyen una base de reclamación por no estar de acuerdo el producto con el contrato. Según la ley, está permitido adjuntar un manual de otra forma que no sea en papel, lo cual últimamente es bastante común y los fabricantes nos facilitan un manual gráfico, su versión electrónica Heat & Glo NorthStar-BK o vídeos de instrucciones para usuarios. La condición es que tenga una forma legible y entendible.
¿Qué es un manual de instrucciones?
El nombre proviene de la palabra latina “instructio”, es decir, ordenar. Por lo tanto, en un manual Heat & Glo NorthStar-BK se puede encontrar la descripción de las etapas de actuación. El propósito de un manual es enseñar, facilitar el encendido o el uso de un dispositivo o la realización de acciones concretas. Un manual de instrucciones también es una fuente de información acerca de un objeto o un servicio, es una pista.
Desafortunadamente pocos usuarios destinan su tiempo a leer manuales Heat & Glo NorthStar-BK, sin embargo, un buen manual nos permite, no solo conocer una cantidad de funcionalidades adicionales del dispositivo comprado, sino también evitar la mayoría de fallos.
Entonces, ¿qué debe contener el manual de instrucciones perfecto?
Sobre todo, un manual de instrucciones Heat & Glo NorthStar-BK debe contener:
- información acerca de las especificaciones técnicas del dispositivo Heat & Glo NorthStar-BK
- nombre de fabricante y año de fabricación del dispositivo Heat & Glo NorthStar-BK
- condiciones de uso, configuración y mantenimiento del dispositivo Heat & Glo NorthStar-BK
- marcas de seguridad y certificados que confirmen su concordancia con determinadas normativas
¿Por qué no leemos los manuales de instrucciones?
Normalmente es por la falta de tiempo y seguridad acerca de las funcionalidades determinadas de los dispositivos comprados. Desafortunadamente la conexión y el encendido de Heat & Glo NorthStar-BK no es suficiente. El manual de instrucciones siempre contiene una serie de indicaciones acerca de determinadas funcionalidades, normas de seguridad, consejos de mantenimiento (incluso qué productos usar), fallos eventuales de Heat & Glo NorthStar-BK y maneras de solucionar los problemas que puedan ocurrir durante su uso. Al final, en un manual se pueden encontrar los detalles de servicio técnico Heat & Glo en caso de que las soluciones propuestas no hayan funcionado. Actualmente gozan de éxito manuales de instrucciones en forma de animaciones interesantes o vídeo manuales que llegan al usuario mucho mejor que en forma de un folleto. Este tipo de manual ayuda a que el usuario vea el vídeo entero sin saltarse las especificaciones y las descripciones técnicas complicadas de Heat & Glo NorthStar-BK, como se suele hacer teniendo una versión en papel.
¿Por qué vale la pena leer los manuales de instrucciones?
Sobre todo es en ellos donde encontraremos las respuestas acerca de la construcción, las posibilidades del dispositivo Heat & Glo NorthStar-BK, el uso de determinados accesorios y una serie de informaciones que permiten aprovechar completamente sus funciones y comodidades.
Tras una compra exitosa de un equipo o un dispositivo, vale la pena dedicar un momento para familiarizarse con cada parte del manual Heat & Glo NorthStar-BK. Actualmente se preparan y traducen con dedicación, para que no solo sean comprensibles para los usuarios, sino que también cumplan su función básica de información y ayuda.
Índice de manuales de instrucciones
-
Página 1
www .heatnglo.com Heat & Glo • NorthStar EP A Fireplace • 480-1081C September 1, 2008 O - T L T ested and Listed by Portland Oregon USA OMNI-T est Laboratories, Inc. C US DO NOT DISCARD THIS MANUAL CAUTION • I m p o r t a n t o p e r a t i n g and maintenance instructions included. • Leave this manual with party responsible for use and [...]
-
Página 2
Page 2 Heat & Glo • NorthStar EP A Fireplace • 480-1081C September 1, 2008 Rea d this man ual be fore in stall ing or opera ting thi s appl iance. Ple ase re tain this o wner's man ual f or futu re re ference . Con gratu lati on s Congratulations on selecting a Heat & Glo gas appliance - an elegant and clean alternative to wood bur[...]
-
Página 3
September 1, 2008 Heat & Glo • NorthStar EP A Fireplace • 480-1081C Page 3 Section 1: Listing and Code Approval s A. ApplianceCertication .................... 4 B. MobileHome Approved .................... 4 C. GlassSpecications ...................... 4 D. BTU&EfciencySpecications ............[...]
-
Página 4
Page 4 Heat & Glo • NorthStar EP A Fireplace • 480-1081C September 1, 2008 September 1, 2008 September 1, 2008 1 Listing an d Code Appro vals A. Appliance Certication Model: NorthStarEPACertied Woodburning Fireplace Laboratory: OMNIT estLaboratories,Inc. Report No: 061-S-40-2 Type: Wood Fireplace Standard: UL127an[...]
-
Página 5
September 1, 2008 September 1, 2008 Heat & Glo • NorthStar EP A Fireplace • 480-1081C Page 5 EPA Certied: 3.25 grams per hour Efciency: up to 77.8% BTU Output with EPA test fuel: with cord wood: 51,400/hr. 70,000/hr Vent Size: 8 inches Firebox Size: 2.7 cubic feet Max Wood Length: 24 inches Fuel: Cord Wood Shipping Weight: 650 lbs [...]
-
Página 6
Page 6 Heat & Glo • NorthStar EP A Fireplace • 480-1081C September 1, 2008 September 1, 2008 September 1, 2008 2 Get ting Star te d A. Design and Installation Considerations Draft is the pressure difference needed to vent replaces successfully .Considerationsforsuccessfuldraftinclude: • Prevent[...]
-
Página 7
September 1, 2008 September 1, 2008 Heat & Glo • NorthStar EP A Fireplace • 480-1081C Page 7 Figure 7.1 Recommended Chimney Locations Recommended Location Marginal Location Location Not Recommended Recommended Location Location NOT Recommended Multi-level Roofs Windward Leeward[...]
-
Página 8
Page 8 Heat & Glo • NorthStar EP A Fireplace • 480-1081C September 1, 2008 September 1, 2008 September 1, 2008 Figure 8.1 T ypical Fireplace System Not e : Junction b o x should be installed dur ing initial setup NOTE: Illustrations used throughout these instructions reect “typical installations” and ar[...]
-
Página 9
September 1, 2008 September 1, 2008 Heat & Glo • NorthStar EP A Fireplace • 480-1081C Page 9 Before beginning the installation be sure the following tools andbuildingsuppliesareavailable: Reciprocating saw Framing material Pliers High temp caulking material Hammer Gloves Phillips screwdriver Framing square Flat blade screwdriver[...]
-
Página 10
Page 10 Heat & Glo • NorthStar EP A Fireplace • 480-1081C September 1, 2008 September 1, 2008 September 1, 2008 3 F raming and C learances A. Selecting Fireplace Location Several options are available to you when choosing a loca- tionfor yourreplace. Thisreplacemay beusedas aroom divider , installed[...]
-
Página 11
September 1, 2008 September 1, 2008 Heat & Glo • NorthStar EP A Fireplace • 480-1081C Page 1 1 B. Clearances Figure 1 1.1 Clearances to Combustible Materials Fire Risk • Complywithallminimumclearancestocombustiblesasspecied. • Framingornishingmaterialusedonthefrontof,orin[...]
-
Página 12
Page 12 Heat & Glo • NorthStar EP A Fireplace • 480-1081C September 1, 2008 September 1, 2008 September 1, 2008 12 in. (305mm) 42 in. (1067mm) 43-7/8 in. (1 1 14mm) 24 in. (610mm) 2 in. (51mm) Figure 12.1 Framing the Fireplace Position combustible / non-combustible mantel 60 in. (1524mm) from base of the replace WITHIN ENCLOSURE AREA: Ap[...]
-
Página 13
September 1, 2008 September 1, 2008 Heat & Glo • NorthStar EP A Fireplace • 480-1081C Page 13 Fire Risk Do not apply combustible nishing materials overanypartofthefrontofthisreplace. • T he me tal r ep la ce fac e m ay on ly be covered with noncombustible materia[...]
-
Página 14
Page 14 Heat & Glo • NorthStar EP A Fireplace • 480-1081C September 1, 2008 September 1, 2008 September 1, 2008 E. Construct the Chase A chase is a vertical boxlike structure built to enclose the re - place and/or its vent system. V ertical chimneys that run on the outside o[...]
-
Página 15
September 1, 2008 September 1, 2008 Heat & Glo • NorthStar EP A Fireplace • 480-1081C Page 15 A. Install the Outside Air Kit Thisreplace will operatecorrectly only ifadequate ventila - tionisprovidedtoallowproper drafttothereplacesystem. See Section 2. Using an outside air kit m[...]
-
Página 16
Page 16 Heat & Glo • NorthStar EP A Fireplace • 480-1081C September 1, 2008 September 1, 2008 September 1, 2008 Risk of Smoke Spillage Outside air inlet must be located to prevent blockage from: • Leaves • Snow/ice • Otherdebris Blockage may cause combustion air starvation. CAUTION Fire Risk[...]
-
Página 17
September 1, 2008 September 1, 2008 Heat & Glo • NorthStar EP A Fireplace • 480-1081C Page 17 Figure 17.1 Outside Combustion Air Placement Outlet blocked by snow , leaves, etc. NO Garage or combustible liquids storage NO Attic space NO Outlet placed higher than 3 ft below the termination cap NO Use only duct materials specified by manufactu[...]
-
Página 18
Page 18 Heat & Glo • NorthStar EP A Fireplace • 480-1081C September 1, 2008 September 1, 2008 September 1, 2008 • Level the Fireplace Level the replace side-to-side and front-to-back. Shim with noncombustible material, such as sheet metal, as necessary .Secure the replace(using the pallet mo[...]
-
Página 19
September 1, 2008 September 1, 2008 Heat & Glo • NorthStar EP A Fireplace • 480-1081C Page 19 NOTE: • Chimney performance may vary . • T rees, buildings, roof lines and wind conditions affect performance. • Chimney height may need adjustment if smoking or overdraft occurs. Chimney must extend beyond combustible roof structure Maintain[...]
-
Página 20
Page 20 Heat & Glo • NorthStar EP A Fireplace • 480-1081C September 1, 2008 September 1, 2008 September 1, 2008 A. Chimney Requirements V erticaldistancesaremeasuredfromthebaseofthere - place as shown in Figure 20.1. T o determine the chimney components needed to complete yourparticularinstallation,fol[...]
-
Página 21
September 1, 2008 September 1, 2008 Heat & Glo • NorthStar EP A Fireplace • 480-1081C Page 21 • Mea sure ho w far the chi mney need s to be shi fted to enab le it to avoid the overhead obstacle. See Figure 21.2. Use dimension “A” to determine chimney section required to achieve the needed shift.[...]
-
Página 22
Page 22 Heat & Glo • NorthStar EP A Fireplace • 480-1081C September 1, 2008 September 1, 2008 September 1, 2008 D. Assemble the Chimney Sections Attach either a straight chimney section or an offset to the top of the replace (depending on your installation require - ment). Chimney sections are locked together by p[...]
-
Página 23
September 1, 2008 September 1, 2008 Heat & Glo • NorthStar EP A Fireplace • 480-1081C Page 23 F . Install the Ceiling Firestops • M ark an d cut an ope ning in the ceili ng fo r the c eilin g restopbeingused.SeeFigure23.2. • Frame the opening with the same size lumber used in the [...]
-
Página 24
Page 24 Heat & Glo • NorthStar EP A Fireplace • 480-1081C September 1, 2008 September 1, 2008 September 1, 2008 G. Install the Attic Insulation Shield An insulation shield must be installed when there is a pos- sibility of insulation coming into contact with the factory built chimney system. • Bend th e t ab s at the to p o f t he at tic [...]
-
Página 25
September 1, 2008 September 1, 2008 Heat & Glo • NorthStar EP A Fireplace • 480-1081C Page 25 Slanted Roofs Flat Roofs Chimney must extend 3 ft (914 mm) above the roof Chimney must extend 2 ft (610 mm) above any portion of the roof within 10 ft (3048 mm) of the chimney Chimney must extend 3 ft (914 mm) above the roof Chimney must extend 2 f[...]
-
Página 26
Page 26 Heat & Glo • NorthStar EP A Fireplace • 480-1081C September 1, 2008 September 1, 2008 September 1, 2008 Figure 26.1 Ceiling/Attic Construction Fire Risk • Must maintain 2 in. (51 mm) air clearance to insulation and other combustible materials. W ARNING • Mark the Exit Point of the Roof Locate the point[...]
-
Página 27
September 1, 2008 September 1, 2008 Heat & Glo • NorthStar EP A Fireplace • 480-1081C Page 27 NAIL FLASHING PLA TE CHIMNEY THIMBLE EXTENSION SCREW FLASHING THIMBLE ADJUST ABLE EXTENSION HOLES FLASHING CHIMNEY FLASHING PLA TE NAIL THIMBLE SCREW THIMBLE EXTENSION B. SL-300 Series Ceiling/Roof Thimble 1. Locate the point where the chimney will[...]
-
Página 28
Page 28 Heat & Glo • NorthStar EP A Fireplace • 480-1081C September 1, 2008 September 1, 2008 September 1, 2008 T ermination Cap Storm Collar Slope Downward T urn-down Drip Edge Chase (Chimney) 2 in. (51 mm) Collar on Chase T op Caulk .018 (26 ga) min. Galvanized Chase T op Figure 28.1 Chase T op Construction 2 in. (51 mm) min. collar 6 in.[...]
-
Página 29
September 1, 2008 September 1, 2008 Heat & Glo • NorthStar EP A Fireplace • 480-1081C Page 29 Storm Collar Flashing Collar T op of Pipe 14-1/2 in. (368mm) max. 1-1/2 in. (38 mm) min. overlap 2 in. (51 mm) min. Figure 29.1 Installing a TR342 Round T elescoping T ermination Cap 2 in. (51 mm) min. 4-1/2in. (1 14 mm) max. 1-1/2in. (38 mm)[...]
-
Página 30
Page 30 Heat & Glo • NorthStar EP A Fireplace • 480-1081C September 1, 2008 September 1, 2008 September 1, 2008 7 Accessories A. Fan Replacement Screwdriver Slot Screws Unplug wire harness before removing fan Remove nut and lift out fan Fan Cord Location The NorthStar Fireplace comes standard equipped with two fans, installed at the factory[...]
-
Página 31
September 1, 2008 September 1, 2008 Heat & Glo • NorthStar EP A Fireplace • 480-1081C Page 31 B. Bafe Removal and Installation 1. Remove all ash from rebox, and extinguish all hot embers before disposal into a metal container . 2. Remove the bafe protection channel by turning[...]
-
Página 32
Page 32 Heat & Glo • NorthStar EP A Fireplace • 480-1081C September 1, 2008 September 1, 2008 September 1, 2008 This kit is tested and safe when installed in accordance with this installation manual. It is your responsibility to read all instructions before starting installation and to follow these instructions carefully during installation[...]
-
Página 33
September 1, 2008 September 1, 2008 Heat & Glo • NorthStar EP A Fireplace • 480-1081C Page 33 INST ALLA TION 1. Remove the knockout or cover plate from the top of the replaceanddiscardit.SeeFigure33.1. 2. Cut a 3 in. (76mm) hole in the insulation board as per the dimensions shown in Figure 33.1. Adapter Mounting Plat[...]
-
Página 34
Page 34 Heat & Glo • NorthStar EP A Fireplace • 480-1081C September 1, 2008 September 1, 2008 September 1, 2008 NOTE: Secure the duct so that clearance to the re - place outer wrap is maintained. T ape all seams with aluminum tape 1-1/4 in. (32mm) minimum width or as specied by local codes.) 10. Seal all the way around the inside of t[...]
-
Página 35
September 1, 2008 September 1, 2008 Heat & Glo • NorthStar EP A Fireplace • 480-1081C Page 35 E. Timer Assembly Replacement Shock Risk Disconnect power by turning off circuit breaker BEFORE servicing. CAUTION 1. Remove both doors by lifting doors up and off of hinges. 2. Remove the black knob and spring handle. 3. Remove the outside air kno[...]
-
Página 36
Page 36 Heat & Glo • NorthStar EP A Fireplace • 480-1081C September 1, 2008 September 1, 2008 September 1, 2008 9. There is very little room to pull the timer assembly out the front ofthe replace. P lace your hand through the access door in the oor of the replace. Let the timer assem[...]
-
Página 37
September 1, 2008 September 1, 2008 Heat & Glo • NorthStar EP A Fireplace • 480-1081C Page 37 Item Description Qty 1 Screw8-32x1/2PHPHL TC 2 2 Screw6-32x1/4PHPHL TC 2 3 W asher SAE #10 2 4 Bushing 2 5 Linkage Control Arm 1 3. Place linkage control arm over timer shaft and tighten set screw . Figure 37.1. [...]
-
Página 38
Page 38 Heat & Glo • NorthStar EP A Fireplace • 480-1081C September 1, 2008 September 1, 2008 September 1, 2008 8 F inish ing A. Hearth Extension A hearth extension must be installed with all replaces to protect the combustible oor in front of the replace from both radian[...]
-
Página 39
September 1, 2008 September 1, 2008 Heat & Glo • NorthStar EP A Fireplace • 480-1081C Page 39 Figure 39.1 Positioning the Protective Metal Hearth Strips Fire Risk • MetalhearthstripsMUST be installed. Sparksorembersmayigniteooring. W ARNING Fire Risk • Hearth extensions must be installed exactlyasspec[...]
-
Página 40
Page 40 Heat & Glo • NorthStar EP A Fireplace • 480-1081C September 1, 2008 September 1, 2008 September 1, 2008 Fascia OuterCan Flange Ember Strip (Seal gap with High temp, noncombustible sealant able to withstand 300°) T ile or Marble Minimum2-1/4in.(57mm)CementBoard orequivalent,(ortwo1/2in.pi[...]
-
Página 41
September 1, 2008 September 1, 2008 Heat & Glo • NorthStar EP A Fireplace • 480-1081C Page 41 Seal with non-combustible sealant C. Position the Hearth Extension Position and secure the hearth extension over the protective met al s trips that hav e been place d part ial ly und er the repl ace front. These [...]
-
Página 42
Page 42 Heat & Glo • NorthStar EP A Fireplace • 480-1081C September 1, 2008 September 1, 2008 September 1, 2008 TOOLS NEEDED: Powered drill with #2 Phillips head bit; caulking gun. 1in.(25mm)OVERLAP Metal strips 2 in. (51mm) under edge of Fireplace and Hearth Extension and 2 in. (51mm) on both side of fireplace opening. Nail or scr[...]
-
Página 43
September 1, 2008 September 1, 2008 Heat & Glo • NorthStar EP A Fireplace • 480-1081C Page 43 Figure 43.1 Mantel Specications 60 in. (1524mm) Mantel Clearances are from bottom of appliance to lower edge of mantel or trim T rim 48 in. (1219mm) F . Mantel A combustible mantel may be positioned no lower than 60 in.(1524mm)fromthe?[...]
-
Página 44
Page 44 Heat & Glo • NorthStar EP A Fireplace • 480-1081C September 1, 2008 September 1, 2008 September 1, 2008 9 Operating Instr uctions B. General Information Fireplaces, as well as other woodburning appliances, have been used safely for many years. It has been our experience that most problems are caused by improper installation and oper[...]
-
Página 45
September 1, 2008 September 1, 2008 Heat & Glo • NorthStar EP A Fireplace • 480-1081C Page 45 C. Outside Air A source of air (oxygen) is required in order for combustion totakeplace.Whateverair isconsumedbytheremustbe replaced through cracks around windows, under doors, etc. Most newlyconstructed[...]
-
Página 46
Page 46 Heat & Glo • NorthStar EP A Fireplace • 480-1081C September 1, 2008 September 1, 2008 September 1, 2008 D. Clear Space Near the Fireplace Combustible materials must not be stored on the hearth ex- tension. Room furnishings such as drapes, curtains, chairs or other combustibles must be at least 4 ft (1219mm) from theopenfront?[...]
-
Página 47
September 1, 2008 September 1, 2008 Heat & Glo • NorthStar EP A Fireplace • 480-1081C Page 47 CAUTION ALL wiring should be done by a qualied electrician and sha ll be in comp lia nce wi th loc al codes and wi th the Na tio nal Electric Code NFP A/NEC No. 70-current (in the United Sta[...]
-
Página 48
Page 48 Heat & Glo • NorthStar EP A Fireplace • 480-1081C September 1, 2008 September 1, 2008 September 1, 2008 Fire Risk • DoNOTburnwetorgreenwood. • Store wood in dry location. • Stack wood so both ends are exposed to air . Wet, unseasoned wood can cause accumulation of creosote. W ARNING Fire Risk DoNOTs[...]
-
Página 49
September 1, 2008 September 1, 2008 Heat & Glo • NorthStar EP A Fireplace • 480-1081C Page 49 Not e : The r st three or fo ur res should be of m oderate size to allow the oils and binder s to be bur ned from t he rep lac e and t he ref ract or y an d paint to cure. Y ou may[...]
-
Página 50
Page 50 Heat & Glo • NorthStar EP A Fireplace • 480-1081C September 1, 2008 September 1, 2008 September 1, 2008 INCORRECT POSITIONS Ceramic Blanket and Bafe Board are NOT in contactwiththebackoftherebox. Ceramic Blanket is NOT in contact with the back ofthe [...]
-
Página 51
September 1, 2008 September 1, 2008 Heat & Glo • NorthStar EP A Fireplace • 480-1081C Page 51 L. Burning Process Firerequires3thingstoburn:fuel,airandheat.Ifheat isrobbed fromthereplace duringthedryingstage, the new load of wood has reduced the chances for a good clean [...]
-
Página 52
Page 52 Heat & Glo • NorthStar EP A Fireplace • 480-1081C September 1, 2008 September 1, 2008 September 1, 2008 P . Opacity T hisis themeasureof howcleanlyyour replaceis burn - ing. O paci ty is measur ed in p erce nt; 100% o paci ty is w hen an object is totally obscured[...]
-
Página 53
September 1, 2008 September 1, 2008 Heat & Glo • NorthStar EP A Fireplace • 480-1081C Page 53 Q. Chimney Fire Intheeventofachimneyre: • Have the chimney and adjacent structure inspected by qualied professionals. Hearth & Home T echnologies recommendsthat NFIor CSIA certied[...]
-
Página 54
Page 54 Heat & Glo • NorthStar EP A Fireplace • 480-1081C September 1, 2008 September 1, 2008 September 1, 2008 1 0 T rou bleshooting Thisreplace will operatecorrectly only ifadequate ventila - tionisprovidedtoallowproper drafttothereplacesystem. Hearth & Home T echnologies [...]
-
Página 55
September 1, 2008 September 1, 2008 Heat & Glo • NorthStar EP A Fireplace • 480-1081C Page 55 Another appliance in home also exhausting air (furnace, fan, dryer , etc.)? Air register from furnace near fireplace? Doors opening and closing? Window closed for start-up? Outside air closed? Overhead fan operating? Overhanging tree? Bird's n[...]
-
Página 56
Page 56 Heat & Glo • NorthStar EP A Fireplace • 480-1081C September 1, 2008 September 1, 2008 September 1, 2008 C. Diagnostics and Problem Solving Diagnostic Question Possible Causes of Condition Solutions Are the air controls open? • No draft • No combustion air Openaircontrols Is there enough paper? Insufcientheattoi[...]
-
Página 57
September 1, 2008 September 1, 2008 Heat & Glo • NorthStar EP A Fireplace • 480-1081C Page 57 4. I don’t get enough/any heat. What can I do about it? Diagnostic Question Possible Causes of Condition Solutions Howmuchwoodisusedforre? Insufcientfuel Makelargerres How well seasoned is the wood? Condition o[...]
-
Página 58
Page 58 Heat & Glo • NorthStar EP A Fireplace • 480-1081C September 1, 2008 September 1, 2008 September 1, 2008 1 1 Maintenance and Ser vicing the Fire place A. General Maintenance Inspe ction : Inspect th e sy stem at t he appliance co nnecti on and at the chimney top. Cooler surfaces tend to build creosote deposits quicker , so it is impo[...]
-
Página 59
September 1, 2008 September 1, 2008 Heat & Glo • NorthStar EP A Fireplace • 480-1081C Page 59 2. Disposal of Ashes Fire Risk. Disposal of Ashes W ARNING • Ashes should be placed in metal container with tight ttinglid. • Do not place metal container on combustible surface. • Ashes should be retained in closed container until all [...]
-
Página 60
Page 60 Heat & Glo • NorthStar EP A Fireplace • 480-1081C September 1, 2008 September 1, 2008 September 1, 2008 C. Firebrick Replacement The rebox of your replace is lined with high quality rebrick, which has exceptional insulating properties. There is no need to us[...]
-
Página 61
September 1, 2008 September 1, 2008 Heat & Glo • NorthStar EP A Fireplace • 480-1081C Page 61 D. Care and Cleaning of Plated Surfaces Clean-plated surfaces with vinegar or a glass cleaner before lightingyourrstretopreventpermanentstaining. CAUTION • Do not use polishes with abrasives. It will scratch plated surf[...]
-
Página 62
Page 62 Heat & Glo • NorthStar EP A Fireplace • 480-1081C September 1, 2008 September 1, 2008 September 1, 2008 Date of Service Performed By Description of Service F . Service And Maintenance Log[...]
-
Página 63
September 1, 2008 September 1, 2008 Heat & Glo • NorthStar EP A Fireplace • 480-1081C Page 63 1 2 Referen ce Mater ials A. Fireplace Dimensions L K A B C D E F TOP VIEW FRONT VIEW SIDE VIEW NorthStar A B C D E F in 3-1/2 31-1/8 40 37 40-5/16 43-13/16 mm 89 791 1016 940 1024 1 100 G H I J K L in. 6-1/2 9-1 1/16 5-7/8 1 23-1/8 1 1-1/8 mm 165 [...]
-
Página 64
Page 64 Heat & Glo • NorthStar EP A Fireplace • 480-1081C September 1, 2008 September 1, 2008 September 1, 2008 B. Chimney Components RF370 - Roof Flashing Flat to 6/12 Pitch 12 in. (305 mm) 24-5/8in. (625 mm) 27-3/8in. (695 mm) RF371 - Roof Flashing 6/12 to 12/12 Pitch 12in. (305 mm) 31 in. (787 mm) 24-5/8in. (625 mm) Firestop Spa[...]
-
Página 65
September 1, 2008 September 1, 2008 Heat & Glo • NorthStar EP A Fireplace • 480-1081C Page 65 AS8 Straight Attic Insulation Shield 24 in. (610 mm) SL3 - Chimney Stabilizer Inside Diameter 8 in. (203 mm) Outside Diameter 10-1/2in. (267mm) 20-3/4in. (527 mm) SL315-SL330 - Offset/Return Inside Diameter 8 in. (203 mm) Outside Diamet[...]
-
Página 66
Page 66 Heat & Glo • NorthStar EP A Fireplace • 480-1081C September 1, 2008 September 1, 2008 September 1, 2008 Figure 64.1 - NorthStar Fireplace Diagram 27-1/2" 12-3/8" 24" 2.0" Ceramic Blanket 1 3 4 5 6 2 10 12 1 1 9 8 7 14 15 13 Part number list on following page. C. Parts Diagram[...]
-
Página 67
September 1, 2008 September 1, 2008 Heat & Glo • NorthStar EP A Fireplace • 480-1081C Page 67 D. Service Parts and Accessories Beginning Manufacturing Date: 2-17-03 Ending Manufacturing Date: Stocked at Depot Item Description Part No. Comments Serial Number and Date Exploded View Parts List - Numerical Order 1 Starter Plate Assembly SL1 8 i[...]
-
Página 68
Page 68 Heat & Glo • NorthStar EP A Fireplace • 480-1081C September 1, 2008 September 1, 2008 September 1, 2008 D. Service Parts and Accessories Beginning Manufacturing Date: 2-17-03 Ending Manufacturing Date: IMPORT ANT : THIS IS DA TED INFORMA TION . When requesting service or replacement parts for your appliance please provide model numb[...]
-
Página 69
September 1, 2008 September 1, 2008 Heat & Glo • NorthStar EP A Fireplace • 480-1081C Page 69 D. Service Parts and Accessories Beginning Manufacturing Date: 2-17-03 Ending Manufacturing Date: IMPORT ANT : THIS IS DA TED INFORMA TION . When requesting service or replacement parts for your appliance please provide model number and serial numb[...]
-
Página 70
Page 70 Heat & Glo • NorthStar EP A Fireplace • 480-1081C September 1, 2008 September 1, 2008 September 1, 2008 E. W arranty Policy Hearth & Home T echnologies LIMITED W ARRANTY Hearth & Home T echnologies (“HHT”) and its respective brands extends the following warranty for HHT gas, wood, pellet and electric appliances purchased[...]
-
Página 71
September 1, 2008 September 1, 2008 Heat & Glo • NorthStar EP A Fireplace • 480-1081C Page 71 HHT’sobligationunderthiswarrantydoesnotextendtodamagesresultingfrom:(1)installation,operationormain - tenance of the appliance not in accordance with the installation instructions; operati[...]
-
Página 72
Heat & Glo, a brand of Hearth & Home T echnologies 20802 Kensington Boulevard Lakeville, MN 55044 Division of HNI INDUSTRIES Heat & Glo • NorthStar • 480-1081C September 1, 2008 Page 72 CONT ACT INFORMA TION : Please contact your Heat & Glo dealer with any questions or concerns. For the number of your nearest Heat & Glo deal[...]