Heatcraft Refrigeration Products H-IM-FL1A manual
- Consulta online o descarga el manual de instrucciones
- 24 páginas
- 0.62 mb
Ir a la página of
manuales de instrucciones parecidos
-
Refrigerator
Heatcraft Refrigeration Products SWN0075M2B
12 páginas 1.8 mb -
Refrigerator
Heatcraft Refrigeration Products SWN0150H2B
12 páginas 1.8 mb -
Refrigerator
Heatcraft Refrigeration Products H-HTSSB-1208
6 páginas 0.99 mb -
Refrigerator
Heatcraft Refrigeration Products SWN0200M2D
12 páginas 1.8 mb -
Refrigerator
Heatcraft Refrigeration Products PST131H6B*
8 páginas 1.05 mb -
Refrigerator
Heatcraft Refrigeration Products SWN0075M2C
12 páginas 1.8 mb -
Refrigerator
Heatcraft Refrigeration Products PTT
8 páginas 2.13 mb -
Refrigerator
Heatcraft Refrigeration Products SWN0199M6C
12 páginas 1.8 mb
Buen manual de instrucciones
Las leyes obligan al vendedor a entregarle al comprador, junto con el producto, el manual de instrucciones Heatcraft Refrigeration Products H-IM-FL1A. La falta del manual o facilitar información incorrecta al consumidor constituyen una base de reclamación por no estar de acuerdo el producto con el contrato. Según la ley, está permitido adjuntar un manual de otra forma que no sea en papel, lo cual últimamente es bastante común y los fabricantes nos facilitan un manual gráfico, su versión electrónica Heatcraft Refrigeration Products H-IM-FL1A o vídeos de instrucciones para usuarios. La condición es que tenga una forma legible y entendible.
¿Qué es un manual de instrucciones?
El nombre proviene de la palabra latina “instructio”, es decir, ordenar. Por lo tanto, en un manual Heatcraft Refrigeration Products H-IM-FL1A se puede encontrar la descripción de las etapas de actuación. El propósito de un manual es enseñar, facilitar el encendido o el uso de un dispositivo o la realización de acciones concretas. Un manual de instrucciones también es una fuente de información acerca de un objeto o un servicio, es una pista.
Desafortunadamente pocos usuarios destinan su tiempo a leer manuales Heatcraft Refrigeration Products H-IM-FL1A, sin embargo, un buen manual nos permite, no solo conocer una cantidad de funcionalidades adicionales del dispositivo comprado, sino también evitar la mayoría de fallos.
Entonces, ¿qué debe contener el manual de instrucciones perfecto?
Sobre todo, un manual de instrucciones Heatcraft Refrigeration Products H-IM-FL1A debe contener:
- información acerca de las especificaciones técnicas del dispositivo Heatcraft Refrigeration Products H-IM-FL1A
- nombre de fabricante y año de fabricación del dispositivo Heatcraft Refrigeration Products H-IM-FL1A
- condiciones de uso, configuración y mantenimiento del dispositivo Heatcraft Refrigeration Products H-IM-FL1A
- marcas de seguridad y certificados que confirmen su concordancia con determinadas normativas
¿Por qué no leemos los manuales de instrucciones?
Normalmente es por la falta de tiempo y seguridad acerca de las funcionalidades determinadas de los dispositivos comprados. Desafortunadamente la conexión y el encendido de Heatcraft Refrigeration Products H-IM-FL1A no es suficiente. El manual de instrucciones siempre contiene una serie de indicaciones acerca de determinadas funcionalidades, normas de seguridad, consejos de mantenimiento (incluso qué productos usar), fallos eventuales de Heatcraft Refrigeration Products H-IM-FL1A y maneras de solucionar los problemas que puedan ocurrir durante su uso. Al final, en un manual se pueden encontrar los detalles de servicio técnico Heatcraft Refrigeration Products en caso de que las soluciones propuestas no hayan funcionado. Actualmente gozan de éxito manuales de instrucciones en forma de animaciones interesantes o vídeo manuales que llegan al usuario mucho mejor que en forma de un folleto. Este tipo de manual ayuda a que el usuario vea el vídeo entero sin saltarse las especificaciones y las descripciones técnicas complicadas de Heatcraft Refrigeration Products H-IM-FL1A, como se suele hacer teniendo una versión en papel.
¿Por qué vale la pena leer los manuales de instrucciones?
Sobre todo es en ellos donde encontraremos las respuestas acerca de la construcción, las posibilidades del dispositivo Heatcraft Refrigeration Products H-IM-FL1A, el uso de determinados accesorios y una serie de informaciones que permiten aprovechar completamente sus funciones y comodidades.
Tras una compra exitosa de un equipo o un dispositivo, vale la pena dedicar un momento para familiarizarse con cada parte del manual Heatcraft Refrigeration Products H-IM-FL1A. Actualmente se preparan y traducen con dedicación, para que no solo sean comprensibles para los usuarios, sino que también cumplan su función básica de información y ayuda.
Índice de manuales de instrucciones
-
Página 1
H-IM-FL1A December , 2004 Part No. 25006901 Installation and Operation Manual T able of Contents General Safety Information ...................................................... 2 Inspection ................................................................................. 2 W arranty Statement ......................................................[...]
-
Página 2
2 © 2004, Heatcraft Refrigeration Products LLC General Safety Information 1. Installation and maintenance to be performed only by qualified personnel who are familiar with this type of equipment. 2. Some units are pressurized with dry air or inert gas. All units must be evacuated before charging the system with refrigerant. 3. Make sure that all [...]
-
Página 3
3 The most important consideration which must be taken into account when deciding upon the location of air-cooled equipment is the provision for a supply of ambient air to the condenser , and removal of heated air from the condensing unit or remote condenser area. Where this essential requirement is not adhered to, it will result in higher head pre[...]
-
Página 4
4 Figure 2. Solid Mount for Mobile or Deep Sump Application. Condensing Unit Rigging and Mounting Rigging holes are provided on all units. Caution should be exercised when moving these units. T o prevent damage to the unit housing during rigging, cables or chains used must be held apart by spacer bars. The mounting platform or base should be level [...]
-
Página 5
5 Suction Filters, Driers, Sight Glasses There are two types of suction and liquid filter/driers used on Heatcraft Refrigeration Products units. Replaceable core and/or sealed units are used, dependent upon the option package ordered. Suction filters, regardless of type, are always installed upstream of the compressor suction service valve, and a[...]
-
Página 6
6 Mineral Oils The BR and Scroll compressors use Sontex 200, a “white oil”. This oil is not suitable for low temperature applications nor is it available through the normal refrigeration wholesalers. For field “top-off” the use of 3GS or equivalent, or Zerol 200TD is permissible, as long as at least 50% of the total oil charge remains Sont[...]
-
Página 7
7 Phase Loss Monitor The combination phase sequence and loss monitor relay protects the system against phase loss (single phasing), phase reversal (improper sequence) and low voltage (brownout). When phase sequence is correct and full line voltage is present on all three phases, the relay is energized as the normal condition indicator light glows. [...]
-
Página 8
8 Liquid Lines Liquid lines should be sized for a minimum pressure drop to prevent “flashing”. Flashing in the liquid lines would create additional pressure drop and poor expansion valve operation. If a system requires long liquid lines from the receiver to the evaporator or if the liquid has to rise vertically upward any distance, the losses [...]
-
Página 9
9 T able 5. Equivalent Feet of Pipe Due to V alve and Fitting Friction Copper T uber, O.D., Type “L” 1/2 5/8 7/8 1 1/8 1 3/8 1 5/8 2 1/8 2 5/8 3 1/8 3 5/8 4 1/8 5 1/8 6 1/8 Globe V alve (Open) 14 16 22 28 36 42 57 69 83 99 1 18 138 168 Angle V alve (Open) 7 9 12 15 18 21 28 34 42 49 57 70 83 90˚ T urn Through T ee 3 4 5 6 8 9 12 14 17 20 22 28[...]
-
Página 10
10 T able 6. Weight of Refrigerants in Copper Lines During Operation (Pounds per 100 lineal feet of type “L” tubing). Line Size Suction Line at Suction T emperature O.D. Liquid Hot Gas in Inches Refrigerant Line Line -40˚F -20˚F 0˚F +20˚F +40˚F 134a 4.0 .15 .01 .01 .02 .04 .06 3/8 22 3.9 .22 .02 .03 .04 .06 .08 R507, 404A 3.4 .31 .03 .04 .[...]
-
Página 11
1 1 Line Insulation After the final leak test, refrigerant lines exposed to high ambient conditions should be insulated to reduce heat pickup and prevent the formation of flash gas in the liquid lines. Suction lines should be insulated with 3/4" wall Armstrong “Armaflex” or equal. Liquid lines should be insulated with 1/2 inch wall insu[...]
-
Página 12
12 Field Wiring W ARNING: All wiring must be done in accordance with applicable codes and local ordinances. The field wiring should enter the areas as provided on the unit. The wiring diagram for each unit is located on the inside of the electrical panel door . All field wiring should be done in a profes - sional manner and in accordance with all[...]
-
Página 13
13 NOTE: All adjustable controls and valves must be field adjusted to meet desired operation. There are no factory preset controls or valve adjustments. System Balancing - Compressor Superheat IMPORT ANT : In order to obtain the maximum capacity from a system, and to ensure trouble- free operation, it is necessary to balance each and every system.[...]
-
Página 14
14 T able 7. System T roubleshooting Chart PROBLEM POSSIBLE CAUSES POSSIBLE CORRECTIVE STEPS Compressor will not run 1. Main switch open. 1. Close switch. 2. Fuse blown. 2. Check electrical circuits and motor winding for shorts or grounds. Investigate for possible overloading. Replace fuse after fault is corrected. 3. Thermal overloads tripped. 3. [...]
-
Página 15
15 Preventive Maintenance Air Cooled Condensing Units Quarterly 1) Visually inspect unit • Look for signs of oil stains on interconnection piping and condenser coil. Pay close attention to areas around solder joints, building penetrations and pipe clamps. Check any suspect areas with an electronic leak detector . Repair any leaks found and add re[...]
-
Página 16
16 Wiring Diagram for BACU51D2CHPQ 208V 14 AWG COMPRESSOR 1 M7 M8 FAN ARRANGEMENT COMP- 1 ALL COMPRESSORS THERMALLY PROTECTED COMPRESSOR 3 SEE COMPRESSOR ELECTRIC BOX COVERS FOR PROPER CONNECTION M4 M3 M5 M6 M1 M2 COMPRESSOR 2 ZR1 2 ZR19 COMP-3 COMP- 2 COMP-4 ENTRANCE ELECTRICAL COMPRESSOR 4 ZR16 ZR16 50 A C1 75 A C2 # 8 AWG 6 AWG # C4 60 A C3 60 A[...]
-
Página 17
17 Wiring Diagram for BACU59D2CHPQ 208V 14 AWG COMPRESSOR 1 M7 M8 FAN ARRANGEMENT COMP-1 ALL COMPRESSORS THERMALLY PROTECTED COMPRESSOR 3 SEE COMPRESSOR ELECTRIC BOX COVERS FOR PROPER CONNECTION M4 M3 M5 M6 M1 M2 COMPRESSOR 2 ZR12 ZR19 COMP-3 COMP-2 COMP-4 ENTRANCE ELECTRICAL COMPRESSOR 4 ZR19 ZR19 50 A C1 75 A C2 # 8 AWG 6 AWG # C4 75 A C3 75 A # [...]
-
Página 18
18 Control Circuit Wiring Diagram for BACU51 and BACU59[...]
-
Página 19
19 Submittal[...]
-
Página 20
20 Submittal[...]
-
Página 21
21 System Reference Data The following information should be filled out and signed by Refrigeration Installation Contractor at time of start-up. Date System Installed: _____________________________________________________ Installer and Address: _____________________________________________________ __________________________________________________[...]
-
Página 22
22 Notes[...]
-
Página 23
23 Notes[...]
-
Página 24
H EA TCRAFT R EFRIGERA TION P RODUCTS LLC 2175 W EST P ARK P LACE B OULEV ARD • S TONE M OUNT AIN , GA 30087 USA 770-465-5600 • F AX : 770-465-5990 WWW . HEA TCRAFTRPD . COM S inc e produc t im provem e nt i s a c ontinui n g ef for t , we re s er v e th e ri g ht to mak e c han g e s in sp e c i fi c ation s wi tho u t n o tice . V isi t us on[...]