Lincoln Electric Impringer Conveyor Oven 1000 manual
- Consulta online o descarga el manual de instrucciones
- 92 páginas
- 6.54 mb
Ir a la página of
manuales de instrucciones parecidos
-
Convection Oven
Lincoln Electric Impinger Conveyorized Oven 3255
20 páginas 0.42 mb -
Convection Oven
Lincoln Electric Impinger X2 Ovens with Push Button Controls 3240-2
40 páginas 2.7 mb -
Convection Oven
Lincoln Electric Impinger Conveyor Ovens 1633-000-EA
32 páginas 1.8 mb -
Convection Oven
Lincoln Electric 1621-000-EA
24 páginas 1.13 mb -
Convection Oven
Lincoln Electric Impinger Conveyor Ovens 1100 Series
92 páginas 1.29 mb -
Convection Oven
Lincoln Electric Impringer Conveyor Oven 1000
92 páginas 6.54 mb -
Convection Oven
Lincoln Electric CTI 1300 Single Belt Conveyorized Electric Oven 1301
2 páginas 3.25 mb -
Convection Oven
Lincoln Electric Impinger II - Advantage Series
36 páginas 0.7 mb
Buen manual de instrucciones
Las leyes obligan al vendedor a entregarle al comprador, junto con el producto, el manual de instrucciones Lincoln Electric Impringer Conveyor Oven 1000. La falta del manual o facilitar información incorrecta al consumidor constituyen una base de reclamación por no estar de acuerdo el producto con el contrato. Según la ley, está permitido adjuntar un manual de otra forma que no sea en papel, lo cual últimamente es bastante común y los fabricantes nos facilitan un manual gráfico, su versión electrónica Lincoln Electric Impringer Conveyor Oven 1000 o vídeos de instrucciones para usuarios. La condición es que tenga una forma legible y entendible.
¿Qué es un manual de instrucciones?
El nombre proviene de la palabra latina “instructio”, es decir, ordenar. Por lo tanto, en un manual Lincoln Electric Impringer Conveyor Oven 1000 se puede encontrar la descripción de las etapas de actuación. El propósito de un manual es enseñar, facilitar el encendido o el uso de un dispositivo o la realización de acciones concretas. Un manual de instrucciones también es una fuente de información acerca de un objeto o un servicio, es una pista.
Desafortunadamente pocos usuarios destinan su tiempo a leer manuales Lincoln Electric Impringer Conveyor Oven 1000, sin embargo, un buen manual nos permite, no solo conocer una cantidad de funcionalidades adicionales del dispositivo comprado, sino también evitar la mayoría de fallos.
Entonces, ¿qué debe contener el manual de instrucciones perfecto?
Sobre todo, un manual de instrucciones Lincoln Electric Impringer Conveyor Oven 1000 debe contener:
- información acerca de las especificaciones técnicas del dispositivo Lincoln Electric Impringer Conveyor Oven 1000
- nombre de fabricante y año de fabricación del dispositivo Lincoln Electric Impringer Conveyor Oven 1000
- condiciones de uso, configuración y mantenimiento del dispositivo Lincoln Electric Impringer Conveyor Oven 1000
- marcas de seguridad y certificados que confirmen su concordancia con determinadas normativas
¿Por qué no leemos los manuales de instrucciones?
Normalmente es por la falta de tiempo y seguridad acerca de las funcionalidades determinadas de los dispositivos comprados. Desafortunadamente la conexión y el encendido de Lincoln Electric Impringer Conveyor Oven 1000 no es suficiente. El manual de instrucciones siempre contiene una serie de indicaciones acerca de determinadas funcionalidades, normas de seguridad, consejos de mantenimiento (incluso qué productos usar), fallos eventuales de Lincoln Electric Impringer Conveyor Oven 1000 y maneras de solucionar los problemas que puedan ocurrir durante su uso. Al final, en un manual se pueden encontrar los detalles de servicio técnico Lincoln Electric en caso de que las soluciones propuestas no hayan funcionado. Actualmente gozan de éxito manuales de instrucciones en forma de animaciones interesantes o vídeo manuales que llegan al usuario mucho mejor que en forma de un folleto. Este tipo de manual ayuda a que el usuario vea el vídeo entero sin saltarse las especificaciones y las descripciones técnicas complicadas de Lincoln Electric Impringer Conveyor Oven 1000, como se suele hacer teniendo una versión en papel.
¿Por qué vale la pena leer los manuales de instrucciones?
Sobre todo es en ellos donde encontraremos las respuestas acerca de la construcción, las posibilidades del dispositivo Lincoln Electric Impringer Conveyor Oven 1000, el uso de determinados accesorios y una serie de informaciones que permiten aprovechar completamente sus funciones y comodidades.
Tras una compra exitosa de un equipo o un dispositivo, vale la pena dedicar un momento para familiarizarse con cada parte del manual Lincoln Electric Impringer Conveyor Oven 1000. Actualmente se preparan y traducen con dedicación, para que no solo sean comprensibles para los usuarios, sino que también cumplan su función básica de información y ayuda.
Índice de manuales de instrucciones
-
Página 1
1000SeriesS vc REV: 1/5/07 SER VICE MANUA L (DOMESTIC ) IMPING ER CONVEYOR O VENS MODEL SERIES 1000 - 1200 & 1400 Lincoln Foo dservice Products, LLC 1111 North Hadley Road Fort W ayne, Indiana 46804 United States of America Phone : (800) 374 -3004 U.S. Fax: (888 ) 790-8193 • Int’l Fax: (260 ) 436-0735 Technical Service Hot Line (800) 6 78-9[...]
-
Página 2
Impinger I -–1 000 Ser ies Service Ma nual - Dom estic 2 TABLE OF CONTENTS TABLE OF CO NTENT S................................................ ............................................................................ ..................2 SEQUENC E OF OPER ATIONS 10 00/1001/1004/ 1005/120 0/1201/120 4/1205 .......................................[...]
-
Página 3
Impinger I -–1 000 Ser ies Service Ma nual - Dom estic 3 SEQUENCE OF OPERATIONS 1000/100 1/1004/1005/1200/1201/1204/1205 MODEL 10 00 - 120/230 VAC - 60HZ - NATU RAL GAS MODEL 10 01 - 120/230 VAC - 60HZ - L.P. GAS MODEL 10 04 - 120/230 VAC - 60HZ - NATU RAL GAS MODEL 10 05 - 120/230 VAC - 60HZ - L.P. GAS MODEL 12 00 - 120/230 VAC - 60HZ - NATU RAL[...]
-
Página 4
Impinger I -–1 000 Ser ies Service Ma nual - Dom estic 4 generator. The tach. generator is a DC volt age ge nerator which s upplies a voltage to the DC motor control board and is used as a ref erence for m aintaining a constant conveyor sp eed. NOT E The 1200 Ser ies Ovens ut ilize 2 com plete conve yor drive s y stem s. TIME T EMP DISPLAY The T [...]
-
Página 5
Impinger I -–1 000 Ser ies Service Ma nual - Dom estic 5 CONVEYOR DR IVE (S/N 100 to 43 89) Closing the Fa n Switch and the nor mally open C onveyor S witch supplies 120 VAC through a 3A F use, to th e Motor Contr ol Board . AC volts are co nverted to D .C. volts and are sup plied to the C onve yor Motor at board terminals A1 and A2 thr ough a D.[...]
-
Página 6
Impinger I -–1 000 Ser ies Service Ma nual - Dom estic 6 TRANSFO RMER (12.6 VAC) Upon closure of the Fan Switch, 120 VAC is suppl ied to the prim ar y of the 12.6 VAC Transf ormer. The T ransform er steps the voltage d own to 12.6 VAC (norm ally 13 to 14 VAC) w ith a center ta p, and suppl ies power t o the T ime/ Temp. Displa y. The voltage fr o[...]
-
Página 7
Impinger I -–1 000 Ser ies Service Ma nual - Dom estic 7 TIME T EMP DISPLAY Closing the O ven Fan Switch suppl ies 120 VAC , through th e Power T ransform er, to the prim ary of the Tim e/Tem p. Transformer . The secondary out put of the Transf ormers, 12.5to 15 VAC with a c enter tap, is s upplies to ter minals 1, 2, an d3 of the Tim e/Temp. Dis[...]
-
Página 8
Impinger I -–1 000 Ser ies Service Ma nual - Dom estic 8 SCHEMATIC / 1000 , 1001[...]
-
Página 9
Impinger I -–1 000 Ser ies Service Ma nual - Dom estic 9 SCHEMATIC / 1004 , 1005[...]
-
Página 10
Impinger I -–1 000 Ser ies Service Ma nual - Dom estic 10 SCHEMATIC / 1022 , 1023 – S/N Q19077 & BELOW[...]
-
Página 11
Impinger I -–1 000 Ser ies Service Ma nual - Dom estic 11 SCHEMATIC / 1022 , 1023 – S/N Q19078 & A BOVE[...]
-
Página 12
Impinger I -–1 000 Ser ies Service Ma nual - Dom estic 12 SCHEMATIC / 1040 , 1041 – S/N Q14279 & BELOW[...]
-
Página 13
Impinger I -–1 000 Ser ies Service Ma nual - Dom estic 13 SCHEMATIC / 1040 , 1041 – S/N Q14280 & A BOVE[...]
-
Página 14
Impinger I -–1 000 Ser ies Service Ma nual - Dom estic 14 SCHEMATIC / 1200 , 1201[...]
-
Página 15
Impinger I -–1 000 Ser ies Service Ma nual - Dom estic 15 SCHEMATIC / 1202 , 1203 S/N Q14790 & BELOW[...]
-
Página 16
Impinger I -–1 000 Ser ies Service Ma nual - Dom estic 16 SCHEMATIC / 1202 , 1203 S/N Q14791 & ABOVE[...]
-
Página 17
Impinger I -–1 000 Ser ies Service Ma nual - Dom estic 17 SCHEMATIC / 1204 , 1205[...]
-
Página 18
Impinger I -–1 000 Ser ies Service Ma nual - Dom estic 18 SCHEMATIC / 1240 , 1241 – S/N Q14279 & BELOW[...]
-
Página 19
Impinger I -–1 000 Ser ies Service Ma nual - Dom estic 19 SCHEMATIC / 1240 , 1241 – S/N Q14280 & A BOVE[...]
-
Página 20
Impinger I -–1 000 Ser ies Service Ma nual - Dom estic 20 TROUBLESHOOTING GUIDE 1000 & 1200 SYM PTOM POSSIBLE C AUSE EVALU A TION Incom ing Power Suppl y Check breakers / Reset if required / C all Power C o. if needed. (Export Ov ens) For som e export ovens , there is a contr ol circuit step-down tr ansform er. This trans former s teps down s[...]
-
Página 21
Impinger I -–1 000 Ser ies Service Ma nual - Dom estic 21 Air Pressur e Switch Check for 120 VAC on bot h sides of switch. If voltage prese nt on one si de onl y, check f or air tube blockage. A djust air sw itch. If above f ails, replace air pressure s witch. Transf ormer, 24 VAC Check for 120 VAC to primary of transf orm er. Check for 24 VAC fr[...]
-
Página 22
Impinger I -–1 000 Ser ies Service Ma nual - Dom estic 22 Flame Sensor (Ther e should be a visib le pilot flam e at this tim e.) To check for proper flam e sensor oper ation, connect a di gital multim eter (capable of meas uring D. C. m icroamperes) in series between the flam e sensor wire (n orm ally connected t o terminal #4) and term inal #4. [...]
-
Página 23
Impinger I -–1 000 Ser ies Service Ma nual - Dom estic 23 Pilot flam e but no m ain flame Spark Ignitor (Flame Senso r) (Ther e should be a visib le pilot flam e at this tim e). NOT E: The Honeywell I gnition Contr ol uses the spark ignitor as the flam e sensor. If spark continues, chec k f or proper ground con nections at Ignition Contr ol. Chec[...]
-
Página 24
Impinger I -–1 000 Ser ies Service Ma nual - Dom estic 24 1 on 2 on 3 on 4 off 5 off 6 off - Burner Motor Centrif ugal Switch ba d. 1 on 2 on 3 on 4 on 5 of f 6 off - Ignition Co ntrol bad. 1 on 2 on 3 on 4 on 5 o n 6 off - Pilot Shield m issing or warpe d, Flam e Sensor bad, Pi lot - Orifice pl ugged, or Gas Val ve bad. 1 on 2 on 3 on 4 on 5 o n[...]
-
Página 25
Impinger I -–1 000 Ser ies Service Ma nual - Dom estic 25 TROUBLESHOOTING GUIDE SYM PTOM POSSIBLE CAUSE EV A LU ATION Incom ing Power Suppl y Check breakers /Reset if required/ C all Power C o. if needed. (Export Ov ens) For som e export ovens , there is a contr ol circuit step-down tr ansform er. This trans former s teps down supp ly voltage to [...]
-
Página 26
Impinger I -–1 000 Ser ies Service Ma nual - Dom estic 26 Tem perature Control Board Check for 120 VAC input to tem perature contro l board. If not pr esent, ch eck wiring f rom fus e holder to temper ature control boar d. Turn the t emper ature adjustm ent dial to the m axim um temperature position Chec k for 120 VAC at co il of merc ury contact[...]
-
Página 27
Impinger I -–1 000 Ser ies Service Ma nual - Dom estic 27 Speed Contro l Potentiom eter This is a 0 to 400 ohm or 0 to 500 o hm, 10-tur n potentiom eter. W ITH POWER OFF: rem ove the red, white, an d black leads fr om terminals S1, S2, S3. W ith a digital multim eter, chec k the ohm reading ac ross the red to b lack leads. This ohm reading sh oul[...]
-
Página 28
Impinger I -–1 000 Ser ies Service Ma nual - Dom estic 28 Conve yor Gear Motor If DC voltag e is present at A+ and A- a nd the m otor does not run, first chec k the mini break er and then the conve yor. Refer to t he next possi ble cause. Check the leads to the m otor for evidenc e of an y shorts or ope ns, and eac h lead to gro und. If the motor[...]
-
Página 29
Impinger I -–1 000 Ser ies Service Ma nual - Dom estic 29 Conve yor Control(Stepper) Transf ormer Check for 120 VAC supp ly to prim ary of transform er, if voltage is not present, trace wiring back to the f use-holder. If voltage is pr esent, check for output vo ltage from the transf ormer sec ondary. NOT E: this control trans former outputs (2) [...]
-
Página 30
Impinger I -–1 000 Ser ies Service Ma nual - Dom estic 30 NOT E: Time/Tem p displays use two t ypes of tem perature sensor, T hermistor Probe – 2 yellow wires Therm ocouple Probe 1 red wire and 1 white wire Place your p yrometer ther m ocouple into the cen ter between fin gers T2 and T 3 in the o ven. Disconnec t the yellow ti pped therm istor [...]
-
Página 31
Impinger I -–1 000 Ser ies Service Ma nual - Dom estic 31 Conve yor Drive (Stepper) Control Perform all checks as in the above e valuation. If the tim e check is ok ay, refer to the nex t section. Check to see if the conv eyor drive (step per) m otor is running. If motor is not running, ref er to "Conve yor will not run" on page 28. Mag[...]
-
Página 32
Impinger I -–1 000 Ser ies Service Ma nual - Dom estic 32 REMOVAL, INST ALLA TION & ADJUSTMENTS MODEL S ERIES 1000 &1200 CAUTION ! BEFORE R EMOVING OR INSTALLING ANY COM PONENT IN THE IM PINGER OVEN BE SU RE TO DISC ONNECT ELECTRICAL POW ER AND GAS SUP PLY MOTO R, MAIN F AN 1. Shut off power at main bre aker. 2. Rem ove flue by tak ing ou[...]
-
Página 33
Impinger I -–1 000 Ser ies Service Ma nual - Dom estic 33 9 3/4 IN. ± 1/8 IN. COOLING FAN FAN BLADE 3. Reinstall an d locate f an so that the f ront of fan b lades are 9 3/4 " from inside of oven b ack. (See Dra wing) S. N. 4613 & Above (G AS) S. N. 4768 & Above (EL ECTR IC) FAN HUB CONE FAN SPIDER 1 1/2 INCH NOTE: M EASUREMENT MU S[...]
-
Página 34
Impinger I -–1 000 Ser ies Service Ma nual - Dom estic 34 THERM OST A T, COOL ING FAN 1. Shut off power at main bre aker. 2. Rem ove control panel to p and front c over. 3. Rem ove lead wires and m ark f or reassem bly. 4. Rem ove two (2) scre ws and rem ove thermostat. 5. Reassem ble in revers e order. BURNER BL OWER M OTOR 1. Shut off power at [...]
-
Página 35
Impinger I -–1 000 Ser ies Service Ma nual - Dom estic 35 MOTOR CE NTRIFUGAL SWITCH RED RED 24 VAC T O IGNITION CONTROL TO GROUN D TERMINAL ON IGNITION CONT ROL GROUND 24 VAC 120 VAC GREEN WHITE BLACK (BUTTSP LICE CONNECT ORS PRO VIDED FOR 120 VAC P OWE R SUPP LY) WIRING DIAGRAM BURNER BLO WER ASSEM BLY WITH RE LAY RE MOVED TRANSFORM ER P/N 36953[...]
-
Página 36
Impinger I -–1 000 Ser ies Service Ma nual - Dom estic 36 BURNER ASSEM BLY 1. Shut off power at main bre aker. 2. Shut off gas suppl y. 3. Rem ove control panel to p and front pa nel. 4. Rem ove gas control va lve (See "GA S CONTRO L VALVE") 5. Disconnect pilot tube. 6. Rem ove thermostat or s olenoid valve. 7. Rem ove four (4) phillips[...]
-
Página 37
Impinger I -–1 000 Ser ies Service Ma nual - Dom estic 37 M A NIFOLD PRESSURE - A DJU STM ENT 1. Rem ove control panel to p and front c over. 2. W ITH ELECTRIC POW ER AND GAS OF F: rem ove the outlet pr essure tap p lug from the gas control val ve and insta ll the adapter f itting and m anometer. 3. Turn on elec tric power an d gas an d start-up [...]
-
Página 38
Impinger I -–1 000 Ser ies Service Ma nual - Dom estic 38 TEM PERA TUR E CONT ROL POT ENTIOM ETER – REPL ACEMENT 1. Rem ove control panel to p and front c over. 2. Rem ove one screw from control knob g uard and m ove guard t o one side. 3. Rem ove knob and lock nut on contro l pot. shaf t and push out. 4. Rem ove three (3) wires f rom tem perat[...]
-
Página 39
Impinger I -–1 000 Ser ies Service Ma nual - Dom estic 39 HEATING ELEMENT 1. Shut off power at main bre aker. 2. Rem ove rear motor c over. 3. Disconnect heater elem ent wire a nd mark for reass embly. 4. Rem ove oven back assembly. NOT E: For ovens SN 4768 and above , remove f an shroud. 5. Rem ove two (2) mounting s crews an d remove h eating e[...]
-
Página 40
Impinger I -–1 000 Ser ies Service Ma nual - Dom estic 40 1 24V 2 24V 24V 24V (GND) MV MV/PV PV GND BLUE FROM VALVE BLACK FROM VALV E #3 RED FROM VALV E TO PILOT LIGHT BUTT SPLICE AND NEW GREEN WIRE SUPPLIED IN KIT W HITE FROM PILOT LIGHT 2 MV/PV 4 GND 1 MV 3 PV 5 6 24V 24V GND 9 SPARK IGNITOR/SENSOR CABLE FROM BLOWER CENTRIFU GAL SWITCH #3 RED F[...]
-
Página 41
Impinger I -–1 000 Ser ies Service Ma nual - Dom estic 41 FLAME SE NSOR 1. Shut off power at main bre aker. 2. Rem ove control panel to p and front c over. 3. Rem ove burner assem bly (see burner assem bly ). 4. Disconnect one (1) wire from flame sensor. 5. Rem ove flame sens or by rem oving one (1) m ounting nut. 6. Reassem ble in revers e order[...]
-
Página 42
Impinger I -–1 000 Ser ies Service Ma nual - Dom estic 42 PILOT O RIFICE - BURN ER 1. Shut off power at main bre aker. 2. Shut off gas suppl y. 3. Rem ove burner assem bly (see Burner As sem bly). 4. Rem ove pilot line from pilot orifice. 5. Rem ove pilot orifice fr om burner igni ter. 6. Reassem ble in revers e order. M A IN ORIFICE - BURNER 1. [...]
-
Página 43
Impinger I -–1 000 Ser ies Service Ma nual - Dom estic 43 CONVEYOR M OTO R REPL A CEM ENT - B A LDOR 1000 SERI ES SN 4390 - 14974 1200 SERI ES SN 4390 – 14791 1. Shut off power at main bre aker. 2. Rem ove control panel to p and front c over. 3. Rem ove the conve yor drive chain f rom the m otor sprock et. 4. Rem ove chain guard. 5. Rem ove the[...]
-
Página 44
Impinger I -–1 000 Ser ies Service Ma nual - Dom estic 44 OPTIC AL ENCODER ASSEM BLY 1. Shut off power at main bre aker. 2. Rem ove conveyor m otor assem bly .If replacing with new ass embl y , cut wires to rem ove as new wires and plug are provided. If only rem oving for acc ess to coup ling follo w step 4. 3. Rem ove pins from connectors with p[...]
-
Página 45
Impinger I -–1 000 Ser ies Service Ma nual - Dom estic 45 PLACE DIGIT AL VOLT METER LEADS O N term inal S1 and S 2, adjust the max pot. for a reading of 3.4 VDC. Place MET ER LEADS o n term inals A1 and A2. A djust the reg. p ot. for a rea ding of 125 V DC. NOT E: In some instanc es when the in put AC volta ge runs on t he high side of the norm a[...]
-
Página 46
Impinger I -–1 000 Ser ies Service Ma nual - Dom estic 46 D. C. M OTOR CONT ROL BO ARD SN 4390 - 149 74 1000 S ERIES G AS OVENS SN 4390 - 147 90 1200 S ERIES Three dif ferent styles of control boards have bee n used and a ll three are s till usable. All three were s upplied under the sam e part num ber. ST YLE 1 CON TROL BO ARD ADJUST MENT NOT E:[...]
-
Página 47
Impinger I -–1 000 Ser ies Service Ma nual - Dom estic 47 check ed until both "MIN " and "MAX" are in proper adjus tment. Measure the s peed of the c onveyor an d adjust the time/tem p. displa y i f necess ary. Seal pots with Glyptol or na il polish. NOT E: Occasionall y a new board (St yle 2 and 3 o nly) is so f ar out of adj[...]
-
Página 48
Impinger I -–1 000 Ser ies Service Ma nual - Dom estic 48 STEPPER CON TROL - ADJUSTM ENT S/N 14975 AND A BOVE 1000 SERIE S G A S OVEN S/N 14792 AND A BOVE 1200 SERIE S G A S OVEN Blue Gray Red Brown Red POW ER J 5 J 4 J 3 J 1 J 6 LOCKED ROTOR To T/T display POTENTIOM ETER Max . Conveyor Speed Ad j. Min. Conveyor Speed Ad j. TIME/T EMP Black to #4[...]
-
Página 49
Impinger I -–1 000 Ser ies Service Ma nual - Dom estic 49 REVERSING C ONVEY OR DIRECT ION SN 100-4389 (BODINE) 1. Shut off power at main bre aker. 2. Rem ove control panel to p. 3. Turn revers ing switch (l ocated on rel ay box) to obt ain desired b elt directio n. 4. Reassem ble in revers e order. SN 4390-149 74 1000 SERIES G AS OVEN SN 4390-147[...]
-
Página 50
Impinger I -–1 000 Ser ies Service Ma nual - Dom estic 50 BEARING, C ONVEYOR SN 2164 AND ABOV E 1. Rem ove conveyor fr om oven and p lace on a flat work sur face. 2. Rem ove connecting link s from conveyor beltin g. See Ins tallation and O perating In structions M anual . 3. Rem ove conveyor belt ing from conveyor DRIVE END 4. Rem ove drive sproc[...]
-
Página 51
Impinger I -–1 000 Ser ies Service Ma nual - Dom estic 51 TEM PERA TUR E G AUGE - REPL ACEMENT 1. Shut off power at main bre aker. 2. Rem ove control panel to p. 3. Disconnect thermoc ouple from temperature gauge. 4. Rem ove two (2) mounting bolts and rem ove tem perature gauge . 5. Reassem ble in revers e order. THERM ISTOR - R EPLACEM ENT 1. Sh[...]
-
Página 52
Impinger I -–1 000 Ser ies Service Ma nual - Dom estic 52 ALL 1000 & 1 200 SERI ES OVENS SWITC H SETTING S 1 2 3 4 5 6 7 8 9 10 TYPE I OFF OFF* ON ON ON OFF* * TYPE II OFF O FF* OFF** ON ON ON TYPE III OFF O FF* OFF** ON OFF ON ON ON OFF ON (Baldor Motor ) TYPE III OFF O FF* OFF** ON OFF OFF ON ON OFF ON (Stepper M otor) TYPE IV OFF O FF ** O[...]
-
Página 53
Impinger I -–1 000 Ser ies Service Ma nual - Dom estic 53 T y pe IV has a djustm ent pots. In the c enter boar d. If temper ature is still inac curate after above calibra tion and tro ubleshooti ng, use the f ollowing to check the High Tem p. Pot. norm ally the High T emp. Pot. does not require adjustm ent. Occas ionally the pot is acc identall y[...]
-
Página 54
Impinger I -–1 000 Ser ies Service Ma nual - Dom estic 54 Dip Swit ch 1 2 3 4 5 6 7 8 9 10 TYPE I OFF OF F OFF ON OFF OFF TYPE II OFF OF F OFF OFF OFF OFF TYPE III OFF OF F OFF OFF OFF OFF OFF O N OFF ON NOT E: W hen on 50 HZ po wer, dip switc h #2 m ust be "ON" W ith power ON turn tim e and tem perature cal. pot. fully cou nterclock wi[...]
-
Página 55
Impinger I -–1 000 Ser ies Service Ma nual - Dom estic 55 THE FO LLOWING ITEMS ARE USE D IN THE M ODEL 1030, 10 46, 1047 IMPING ER OVEN (EXPOR T) AIR PRESSU RE SWIT CHES - RE PLACEMENT AND ADJU STMENT 1. Rem ove control panel to p. 2. Disconnect wires from switch m aking note of wire n umber and l ocation for r einstallation. 3. Rem ove air tube [...]
-
Página 56
Impinger I -–1 000 Ser ies Service Ma nual - Dom estic 56 IGNITIO N CONT ROL - REPL A CEMENT 1. Rem ove control panel to p and front c over. 2. Loosen t wo (2) locking sc rews on fr ont cover of rela y (approx. 1 /2 turn). 3. Rem ove front portion of relay b y pulling straig ht out (rock ing motion). 4. Rem ove wires from plug-in term inal strip,[...]
-
Página 57
Impinger I -–1 000 Ser ies Service Ma nual - Dom estic 57 BURNER ALARM L IGHT - REPL ACEMENT 1. Rem ove control panel to p and front c over. 2. Rem ove two (2) wires f rom light assem bly, not e wire num ber and locatio n. 3. Grasp bod y of light assem bly and slide s idewa ys to rem ove. 4. Reassem ble in revers e order and ch eck. PILOT L IGHT [...]
-
Página 58
Impinger I -–1 000 Ser ies Service Ma nual - Dom estic 58 TEM PERA TUR E CONT ROL POT ENTIOM ETER - REPL ACEMENT 1. Rem ove control panel to p and front c over. 2. Rem ove one screw from control knob g uard and m ove guard t o one side. 3. Rem ove knob and lock nut on contro l pot shaf t and pushout. 4. Rem ove three (3) wires f rom tem perature [...]
-
Página 59
Impinger I -–1 000 Ser ies Service Ma nual - Dom estic 59 THIS PAG E INTENT IONALLY LEFT BLANK.[...]
-
Página 60
Impinger I -–1 000 Ser ies Service Ma nual - Dom estic 60 PARTS / MO DEL SERIE S 1000 & 1200 - GENER AL LETTER PART NO . DESCRIPT ION A 369003 Door Hing e B 369207 Handle Reta iner 369337 Retainer ( See page 62) C 369110 Access W indow (See pa ge 62) D 369209 Latch & Str ike E 369828 Handle Sp acer F 369157 Com plete Door G 1534 Finger Su[...]
-
Página 61
Impinger I -–1 000 Ser ies Service Ma nual - Dom estic 61 BLOW UP / 1000, 1200 – GENERAL[...]
-
Página 62
Impinger I -–1 000 Ser ies Service Ma nual - Dom estic 62 PARTS / A CCESS DOOR & 1050 DOOR LETTER PART NO . DESCRIPT ION 369110 Complete Acc ess W indow Ass y. A 369310 Screw, 6-3 2 x 3/16” B 369377 Screw, 8-3 2 x 3/8” C 369308 Bottom , Access W indow Ass y . D 369111 Glass, Old Style 4 9/32” X 20” 369334 Glass, Ne w Style 4” x 20?[...]
-
Página 63
Impinger I -–1 000 Ser ies Service Ma nual - Dom estic 63 BLOW UP / A CCESS DOOR & 1050 DOOR[...]
-
Página 64
Impinger I -–1 000 Ser ies Service Ma nual - Dom estic 64 PARTS / MODEL 10 00,1001,1050,1051,1004, &1005 – S/N 100 TO 4389 LETTER PART NO . DESCRIPT ION A 369012 Fuseholder 369013 Fuse, 3 Am p B 369014 Fuse, 10 Am p C 369066 Sprock et, Drive - Prior to S/N 4390 D 369260 Switch, ON/O FF E 350225 Lens, Red F 369104 Pilot Lig ht, 24 VAC G 3690[...]
-
Página 65
Impinger I -–1 000 Ser ies Service Ma nual - Dom estic 65 BLOW UP / 1000, 1001, 1050, 1051, 1004, & 10 05 S/N 100 TO 4389[...]
-
Página 66
Impinger I -–1 000 Ser ies Service Ma nual - Dom estic 66 PARTS / MODEL 10 00,1001,1004, A ND 1005 S/ N 4390 & ABOVE LETTER P/N DES CRIPTION A 369247 Shaft Lock Rin g B 369248 Knob 3690 64 Conveyor Spee d Control Dial (Non-Digital Display Ovens) C 3 69012 Fus eholder D 3 69013 Fus e, 3 Amp 3690 14 Fuse, 10 Amp E 36 9158 10 Tooth Sprocket - S/[...]
-
Página 67
Impinger I -–1 000 Ser ies Service Ma nual - Dom estic 67 BLOW UP 1000, 1001, 1004, 1005 S/N 4390 & ABOVE[...]
-
Página 68
Impinger I -–1 000 Ser ies Service Ma nual - Dom estic 68 PARTS / 1022 -1023 LETTER P/N DESCRIPTION A 36 9247 Shaft Lock Ring B 36 9012 Fusehol der 3691 29 Fuseholder, Main F an C 3 69013 Fus e, 3 Amp 3691 30 Fuse, 15A D 3 69064 Conveyor S peed Control Dial-Non Digital Display Units 369248 Knob E 36 9260 Switch, ON/OFF F 369066 Sprocket, Drive - [...]
-
Página 69
Impinger I -–1 000 Ser ies Service Ma nual - Dom estic 69 BLOW UP / 1022, 1023[...]
-
Página 70
Impinger I -–1 000 Ser ies Service Ma nual - Dom estic 70 PARTS / 1040 -1041 LETTER P/N DES CRIPTION A 369247 Shaft Lock Rin g B 369012 Fuseholder C 369013 Fuse, 3 Amp 369014 Fuse, 10 Amp D 369248 Knob E 369158 10 Tooth Sp rocket - S/N 4390 to Q14973 369066 Sprocket - S /N 14974 & Above F 369260 Switch, ON/OFF G 369605 Transformer (Ste pper) [...]
-
Página 71
Impinger I -–1 000 Ser ies Service Ma nual - Dom estic 71 BLOW UP / 1040, 1041[...]
-
Página 72
Impinger I -–1 000 Ser ies Service Ma nual - Dom estic 72 PARTS / 1200 , 1201, 1204 AND 1205 LETTER P/N DESCRIPT ION A 369012 Fuseholder B 369014 Fuse, 10 Am p C 369252 Paddle Switc h D 369248 Knob 369247 Shaft Lock Ring E 369260 Switch, ON/O FF G 350225 Lens, Red H 369507 Cooling Fan Therm ostat I 369104 Pilot Light, 24 VAC J 369193 Therm istor [...]
-
Página 73
Impinger I -–1 000 Ser ies Service Ma nual - Dom estic 73 BLOW UP / 1200, 1201, 1204, 1205[...]
-
Página 74
Impinger I -–1 000 Ser ies Service Ma nual - Dom estic 74 PARTS / 1202 -1203 LETTER P/N DES CRIPTION A 369247 Shaft Lock Ring B 369129 Fuseholder, 15A 369012 Fuseholder C 369013 Fuse, 3 Am p 369130 Fuse, 15A D 369248 Knob E 369252 Paddle Switc h F 369260 Switch , ON/OFF H 350225 Lens, Red I 369128 Neon Pilot L ight, 125 VAC J 369025 Blower Air Sw[...]
-
Página 75
Impinger I -–1 000 Ser ies Service Ma nual - Dom estic 75 BLOW UP / 1202, 1203[...]
-
Página 76
Impinger I -–1 000 Ser ies Service Ma nual - Dom estic 76 PARTS / 1240 -1241 LETTER P/N DESCRIPTION A 36 9012 Fusehol der B 36 9014 Fuse , 10 Amp C 369248 Knob D 3 69247 Shaf t Lock Ring E 36 9260 Switch, ON/OFF G 350225 Lens, Red H 3 69507 Cool ing Fan Thermostat I 369104 Pilot Light, 24 VAC J 369025 Blower Air Switch K 36 9032 Relay L 369363 Un[...]
-
Página 77
Impinger I -–1 000 Ser ies Service Ma nual - Dom estic 77 BLOW UP / 1240, 1241[...]
-
Página 78
Impinger I -–1 000 Ser ies Service Ma nual - Dom estic 78 PARTS / OVEN B ACK - GAS LETTER P/N DESCRIPT ION A 369048 Motor and F an Cover B 369212 Motor, S/N beg ins with a"Q " 369214 Motor, 50 H z, 240V C 369192 Capacitor 7. 5 MFD, 370 V AC D 369045 Oven Back - S/N 4612 & Below 369306 Oven Back Assy. - S/N 46 13 & Ab ove E 36964[...]
-
Página 79
Impinger I -–1 000 Ser ies Service Ma nual - Dom estic 79 BLOW UP / OVEN BACK – GAS[...]
-
Página 80
Impinger I -–1 000 Ser ies Service Ma nual - Dom estic 80 PARTS / OVEN B ACK- ELECTRIC LETTER P/N DES CRIPTION A 369699 Rear Cover Assy. B 369212 Motor, S/N beg ins with a "Q" 369214 Motor, 50 H z, 240V C 369192 Capacitor 7. 5 MFD, 370 V AC D 369307 Oven Back Assy. - S/N 47 68 & Abov e E 369122 240V Heati ng Elem ent 369287 208V Hea[...]
-
Página 81
Impinger I -–1 000 Ser ies Service Ma nual - Dom estic 81 BLOW UP / OVEN BACK – ELECTRIC[...]
-
Página 82
Impinger I -–1 000 Ser ies Service Ma nual - Dom estic 82 PARTS / CONVEYOR MOTO R ASSEMBLY S/N 4390 & A BOVE LETTER P/N DES CRIPTION A 369291 Motor, DC - C onveyor 369384 Motor Brush Assy. B 369294 #4 Lock washer C 369296 Screw, 4-40 x 1/4 D 369290 Optical Enco der Ass y. E 369151 Coupling and Encoder D isc (.050 in. Allen W rench included) F[...]
-
Página 83
Impinger I -–1 000 Ser ies Service Ma nual - Dom estic 83 BLOW UP / CONVEYOR MOTOR ASSEMBLY S/N 4390 & ABOVE[...]
-
Página 84
Impinger I -–1 000 Ser ies Service Ma nual - Dom estic 84 PARTS / SERIES 1000 – CONVEYOR LETTER P/N DES CRIPTION A 369002 Tension Knob, Conve yor B 369314 Roll, Conve yor-Notched C 369835 Conve yor Frame Ass y. D 369312 Conve yor Shaft, Idler E 369160 Conve yor Pan Stop F 369641 Idle Be aring Brack et G 369220 Idle Be aring H 369005 Conve yor B[...]
-
Página 85
Impinger I -–1 000 Ser ies Service Ma nual - Dom estic 85 BLOW UP / SERIES 1000 CONVEYOR[...]
-
Página 86
Impinger I -–1 000 Ser ies Service Ma nual - Dom estic 86 PARTS / SERIES 1200 - CONVEYOR CONTROL LETTER P/N DES CRIPTION A SEE PAGE 82 B 369012 Fuseholder C 369013 Fuse, 3 Am p D 369240 Hi Hat E 369155 Conve yor Motor Contro l, "A" S/N Q46 13 to Q14973 369640 Conve yor Control (Stepp er) S/N Q1497 4 & Abo ve 357028 Fuse, Non De lay,[...]
-
Página 87
Impinger I -–1 000 Ser ies Service Ma nual - Dom estic 87 BLOW UP / SERIES 1200 – CONVEYOR CONTROL[...]
-
Página 88
Impinger I -–1 000 Ser ies Service Ma nual - Dom estic 88 PARTS / SERIES 1200 – CONVEYOR LETTER P/N DES CRIPTION A 369277 Retaining Bl ock, Inner B 369275 Flanged Be aring, .50 ID C 369276 Inner Drive S haft D 369274 Flanged Be aring, .75 ID E 369279 Retaining Bl ock, O uter F 369278 Outer Dr ive Shaft G 369241 Sprock et 3/4" Bor e 369242 [...]
-
Página 89
Impinger I -–1 000 Ser ies Service Ma nual - Dom estic 89 BLOW UP / SERIES 1200 – CONVEYOR[...]
-
Página 90
Impinger I -–1 000 Ser ies Service Ma nual - Dom estic 90 This page in tentionally left blank.[...]
-
Página 91
Impinger I -–1 000 Ser ies Service Ma nual - Dom estic 91 This page in tentionally left blank.[...]
-
Página 92
Impinger I -–1 000 Ser ies Service Ma nual - Dom estic 92[...]