Photogenic Professional Lighting PM400 manual
- Consulta online o descarga el manual de instrucciones
- 20 páginas
- 0.25 mb
Ir a la página of
manuales de instrucciones parecidos
-
Power Supply
Photogenic Professional Lighting PM400R
20 páginas 0.25 mb -
Power Supply
Photogenic Professional Lighting PLRX1000DR
24 páginas 0.3 mb -
Power Supply
Photogenic Professional Lighting PowerLight 1250
20 páginas 0.86 mb -
Power Supply
Photogenic Professional Lighting PM800
20 páginas 0.25 mb -
Power Supply
Photogenic Professional Lighting PLR500DR
24 páginas 0.3 mb -
Power Supply
Photogenic Professional Lighting CFF8
16 páginas 0.09 mb -
Power Supply
Photogenic Professional Lighting 1250, 1250DR, 2500DR
20 páginas 0.86 mb -
Power Supply
Photogenic Professional Lighting PLRX500DR
24 páginas 0.3 mb
Buen manual de instrucciones
Las leyes obligan al vendedor a entregarle al comprador, junto con el producto, el manual de instrucciones Photogenic Professional Lighting PM400. La falta del manual o facilitar información incorrecta al consumidor constituyen una base de reclamación por no estar de acuerdo el producto con el contrato. Según la ley, está permitido adjuntar un manual de otra forma que no sea en papel, lo cual últimamente es bastante común y los fabricantes nos facilitan un manual gráfico, su versión electrónica Photogenic Professional Lighting PM400 o vídeos de instrucciones para usuarios. La condición es que tenga una forma legible y entendible.
¿Qué es un manual de instrucciones?
El nombre proviene de la palabra latina “instructio”, es decir, ordenar. Por lo tanto, en un manual Photogenic Professional Lighting PM400 se puede encontrar la descripción de las etapas de actuación. El propósito de un manual es enseñar, facilitar el encendido o el uso de un dispositivo o la realización de acciones concretas. Un manual de instrucciones también es una fuente de información acerca de un objeto o un servicio, es una pista.
Desafortunadamente pocos usuarios destinan su tiempo a leer manuales Photogenic Professional Lighting PM400, sin embargo, un buen manual nos permite, no solo conocer una cantidad de funcionalidades adicionales del dispositivo comprado, sino también evitar la mayoría de fallos.
Entonces, ¿qué debe contener el manual de instrucciones perfecto?
Sobre todo, un manual de instrucciones Photogenic Professional Lighting PM400 debe contener:
- información acerca de las especificaciones técnicas del dispositivo Photogenic Professional Lighting PM400
- nombre de fabricante y año de fabricación del dispositivo Photogenic Professional Lighting PM400
- condiciones de uso, configuración y mantenimiento del dispositivo Photogenic Professional Lighting PM400
- marcas de seguridad y certificados que confirmen su concordancia con determinadas normativas
¿Por qué no leemos los manuales de instrucciones?
Normalmente es por la falta de tiempo y seguridad acerca de las funcionalidades determinadas de los dispositivos comprados. Desafortunadamente la conexión y el encendido de Photogenic Professional Lighting PM400 no es suficiente. El manual de instrucciones siempre contiene una serie de indicaciones acerca de determinadas funcionalidades, normas de seguridad, consejos de mantenimiento (incluso qué productos usar), fallos eventuales de Photogenic Professional Lighting PM400 y maneras de solucionar los problemas que puedan ocurrir durante su uso. Al final, en un manual se pueden encontrar los detalles de servicio técnico Photogenic Professional Lighting en caso de que las soluciones propuestas no hayan funcionado. Actualmente gozan de éxito manuales de instrucciones en forma de animaciones interesantes o vídeo manuales que llegan al usuario mucho mejor que en forma de un folleto. Este tipo de manual ayuda a que el usuario vea el vídeo entero sin saltarse las especificaciones y las descripciones técnicas complicadas de Photogenic Professional Lighting PM400, como se suele hacer teniendo una versión en papel.
¿Por qué vale la pena leer los manuales de instrucciones?
Sobre todo es en ellos donde encontraremos las respuestas acerca de la construcción, las posibilidades del dispositivo Photogenic Professional Lighting PM400, el uso de determinados accesorios y una serie de informaciones que permiten aprovechar completamente sus funciones y comodidades.
Tras una compra exitosa de un equipo o un dispositivo, vale la pena dedicar un momento para familiarizarse con cada parte del manual Photogenic Professional Lighting PM400. Actualmente se preparan y traducen con dedicación, para que no solo sean comprensibles para los usuarios, sino que también cumplan su función básica de información y ayuda.
Índice de manuales de instrucciones
-
Página 1
PhotoMaster Operator’s Manual For Voltage Smart PhotoMaster PM400 Voltage Smart PhotoMaster PM800 Voltage Smart PhotoMaster PM400R Voltage Smart PhotoMaster PM800R & Remote Studio Cont rol Accessories[...]
-
Página 2
2 OPERATOR MANUAL FOR POWER SUPPLIES Voltage Smart PhotoM aster PM400, PM400R, PM800 & PM800R Voltage Smart Advantage Light Heads: PA8, PA8C, PA8D & PA8F Operator Manual for Infrar ed Accessories Thank you for selecting the Photogenic Professional Power Supply PhotoMaster brand Voltage Smart series. The Voltage Smart PhotoMaster series inco[...]
-
Página 3
3 SAFETY PRECAUTIONS Despite the meas ures that have been take n to make electronic flash equipment safe, it must be recognized that high voltages and high temperatures do exist within th e power supply & light heads. Certain pre cautions must be observed in handling the unit. Contact with internal high voltage may result in severe injury or de[...]
-
Página 4
4 To set up the lighting system , first mount and secure all light heads to suitab le stands. The stand adapter allows the light head to be mounted on a stand with a 3 /8” to 5/8” post. Be sure to use a stand th a t is stable and wi ll not tip easily. The light heads are shipped with the m ode ling lamp and flashtube not installed. While instal[...]
-
Página 5
5 The light he ad connectors are key-sh aped , snap-in typ e and will only attach correctly. The plugs must be inserted until the locking snap is heard. Press the flat metal inset to release. The mating pins are autom atically lubricated during each insertio n and withdrawal to greatly extend th e life of these connectors. HANDLE FAN INLET HEAD CON[...]
-
Página 6
6 DIGITAL CONTROL PANEL AND BASIC O PERATION Power Input: The power required to operate the Vo ltage Smart PhotoMas ter PM400, PM400R, PM800, or PM800R is 90 to 250 volts AC, 50 or 60 Hz, 5 Amp. The supplied power cord has a 125V, 15 Amp rating, 15 ft long, and is detachable. For European operation, Photogenic can supply a 230V power cord (PLXLC) w[...]
-
Página 7
7 Functional Operation Voltage Smart PhotoMaster PM400, PM400R, PM800 & PM800R Power Switch: The power switch controls the AC power to both the modeling and flash circuits. You have the option to turn-off the modeli ng circuit independently by pressing the Full On/Off button. Flash Power: When the power is turned on the red Flash LED (A) is ill[...]
-
Página 8
8 Modeling Lights: The modeling lights have three symmetrical modes of operation (NOT independ ent ): 1. MANUAL adjusts the modeling lamp inte nsity using the 1/2 or 1/10 f-stops UP/DOWN arrow buttons. Press the manual ADJUST button (F) to turn the MODEL yellow LED (B) on. Pressing the manual ADJUST button (F) a second time will change th e mode to[...]
-
Página 9
9 “Er-3” message means over heating has occurred. This could be internal or by exceeding the recom mended flash frequency. (See flash rate char t) Once “Er-3” is displayed a “COOL” mode is activated to cool off intern al components, preventing damage. This usually is caused by too ma ny qui ck-di scharg es, resulting in the overheating [...]
-
Página 10
10 Flash Power Bracketing: Bracketing refers to taking up to th ree (3) exposures in a sequence with different flash intensities, either ad ditional watt seconds or fewer watt seconds, from t he displayed or selected “ primary” base i ntensity. The PhotoMaster enables you to set the base flash power and then on e high and one low bracke ting va[...]
-
Página 11
11 OPERATIONAL PARAMETERS Voltage Smart PhotoMaster PM400R & PM400R Flashing Rate: The unit recharges quickly, as indicated by the READY light on the control panel. A quick series of flashes can be obtained within the limits of the recharge time. Continuous rapid flashing, however, can overheat and damag e the flashtube and internal parts. The [...]
-
Página 12
12 SPECIF ICATIONS Voltage Smart PhotoMaster PM400 & PM400R General: Flash Power…........ ............ ........... ..........……….. 12.5 to 400 watt-seconds. Maximum (6 f-st ops) Flash Duration…...... ............ ............ ...........…….. 1/1625 second at Full 1/800 second at 1/32 Reciprocity………………………………[...]
-
Página 13
13 OPERATIONAL PARAMETERS Voltage Smart PhotoMaster PM800, PM800R Flashing Rate: The unit recharges quickly, as indicated by the READY light on the control panel. A quick series of flashes can be obtained within the limits of the recharge time. Continuous rapid flashing, however, can overheat and damag e the flashtube and internal parts. The maximu[...]
-
Página 14
14 SPECIF ICATIONS Voltage Smart PhotoMaster PM800, PM800R General: Flash Power…........ ............ ........... ..........……….. 25 to 800 watt-seconds. Maximum (6 f-st ops) Flash Duration…...... ............ ............ ...........…….. 1/ 962 second at Full 1/431 second at 1/32 Reciprocity……………………………………?[...]
-
Página 15
15 ADVANCED POWERLIGHT FEATURES. Voltage Smart PhotoMaster PM400, P M400R, PM800 & PM8 00R Automa tic Di scharg e Each time the AC line power is disconnecte d or switched off, the un it will automatically flash-dump most of the stored power, and then discharge by resistor the remainder of the stored power. This rem oves all of the flash capacit[...]
-
Página 16
16 Advanced Series Accessories. Voltage Smart PhotoMaster PM400R & PM800R PLIRC-1 Infrared remote controller. Similar to TV, VCR, DTV universal r emote controllers, the PLI RC-1 can control up to nine (9) PhotoMasters with individual se ttings . If several PhotoM asters are us ed with identical settings, the same unit num ber can be assigned to[...]
-
Página 17
17 General Trouble Shooting COMMON PROBLEMS AND CAUSES Unit does not charge. Probable causes : 1. Circuit breaker tripped. (Depress breaker bu tton, rear of unit.) 2. No line power to unit. (Check line cord and outlet. If unit was being heavily used, wait 5 m inutes for internal therm al protector to reset .) Modeling light does not turn on. Probab[...]
-
Página 18
18 Limited PhotoMaster Warranty Photogenic wa rranties the “st andard line” pr oducts are free from defects in material and workmanshi p of the P hotoMaste r PM400, PM40 0R, PM800, PM800R and PA8 u nits for a perio d of three years, from date of manufacture. At our c hoice, we will re pair or re place any of the above that is deemed to be defec[...]
-
Página 19
19 PA8 QUICK CHANGE ACCESSORIES REFLECTORS: PL3R ------ 3” Shallow Background reflector rotates to control light for high key and back lighting. PL3RV----- 3” Veil Slotted Background reflecto r for veil and burst-lighting PL5R------- 5” Deep Conical Ba ckground reflector. PL7R------- 7 ½” Standard high g rain reflector. 35-degree cov erage[...]
-
Página 20
20 Photogenic Professional Lighting 1268 Humbracht Circle Bartlett, Illinois 60103 www.Photogenicpro.com Telephone: 630-830-2500 Fax: 630-830-2525 016497-00V2-04[...]