Watlow Electric Micro-Based Autotuning Control SERIES 980/985 manual
- Consulta online o descarga el manual de instrucciones
- 47 páginas
- 0.89 mb
Ir a la página of
manuales de instrucciones parecidos
-
Network Card
Watlow Electric Series 94
2 páginas 0.11 mb -
Network Card
Watlow Electric RUI/Gateway
20 páginas 0.32 mb -
Network Card
Watlow Electric Ramping and Profiling Microprocessor-Based Control SERIES 1500
90 páginas 0.94 mb -
Network Card
Watlow Electric Series 97
4 páginas 0.11 mb -
Network Card
Watlow Electric Gateway & DeviceNet
21 páginas 0.31 mb -
Network Card
Watlow Electric Power Series
4 páginas 0.17 mb -
Network Card
Watlow Electric SERIES 1500
90 páginas 0.9 mb -
Network Card
Watlow Electric EZ-ZONE PM
80 páginas 3.26 mb
Buen manual de instrucciones
Las leyes obligan al vendedor a entregarle al comprador, junto con el producto, el manual de instrucciones Watlow Electric Micro-Based Autotuning Control SERIES 980/985. La falta del manual o facilitar información incorrecta al consumidor constituyen una base de reclamación por no estar de acuerdo el producto con el contrato. Según la ley, está permitido adjuntar un manual de otra forma que no sea en papel, lo cual últimamente es bastante común y los fabricantes nos facilitan un manual gráfico, su versión electrónica Watlow Electric Micro-Based Autotuning Control SERIES 980/985 o vídeos de instrucciones para usuarios. La condición es que tenga una forma legible y entendible.
¿Qué es un manual de instrucciones?
El nombre proviene de la palabra latina “instructio”, es decir, ordenar. Por lo tanto, en un manual Watlow Electric Micro-Based Autotuning Control SERIES 980/985 se puede encontrar la descripción de las etapas de actuación. El propósito de un manual es enseñar, facilitar el encendido o el uso de un dispositivo o la realización de acciones concretas. Un manual de instrucciones también es una fuente de información acerca de un objeto o un servicio, es una pista.
Desafortunadamente pocos usuarios destinan su tiempo a leer manuales Watlow Electric Micro-Based Autotuning Control SERIES 980/985, sin embargo, un buen manual nos permite, no solo conocer una cantidad de funcionalidades adicionales del dispositivo comprado, sino también evitar la mayoría de fallos.
Entonces, ¿qué debe contener el manual de instrucciones perfecto?
Sobre todo, un manual de instrucciones Watlow Electric Micro-Based Autotuning Control SERIES 980/985 debe contener:
- información acerca de las especificaciones técnicas del dispositivo Watlow Electric Micro-Based Autotuning Control SERIES 980/985
- nombre de fabricante y año de fabricación del dispositivo Watlow Electric Micro-Based Autotuning Control SERIES 980/985
- condiciones de uso, configuración y mantenimiento del dispositivo Watlow Electric Micro-Based Autotuning Control SERIES 980/985
- marcas de seguridad y certificados que confirmen su concordancia con determinadas normativas
¿Por qué no leemos los manuales de instrucciones?
Normalmente es por la falta de tiempo y seguridad acerca de las funcionalidades determinadas de los dispositivos comprados. Desafortunadamente la conexión y el encendido de Watlow Electric Micro-Based Autotuning Control SERIES 980/985 no es suficiente. El manual de instrucciones siempre contiene una serie de indicaciones acerca de determinadas funcionalidades, normas de seguridad, consejos de mantenimiento (incluso qué productos usar), fallos eventuales de Watlow Electric Micro-Based Autotuning Control SERIES 980/985 y maneras de solucionar los problemas que puedan ocurrir durante su uso. Al final, en un manual se pueden encontrar los detalles de servicio técnico Watlow Electric en caso de que las soluciones propuestas no hayan funcionado. Actualmente gozan de éxito manuales de instrucciones en forma de animaciones interesantes o vídeo manuales que llegan al usuario mucho mejor que en forma de un folleto. Este tipo de manual ayuda a que el usuario vea el vídeo entero sin saltarse las especificaciones y las descripciones técnicas complicadas de Watlow Electric Micro-Based Autotuning Control SERIES 980/985, como se suele hacer teniendo una versión en papel.
¿Por qué vale la pena leer los manuales de instrucciones?
Sobre todo es en ellos donde encontraremos las respuestas acerca de la construcción, las posibilidades del dispositivo Watlow Electric Micro-Based Autotuning Control SERIES 980/985, el uso de determinados accesorios y una serie de informaciones que permiten aprovechar completamente sus funciones y comodidades.
Tras una compra exitosa de un equipo o un dispositivo, vale la pena dedicar un momento para familiarizarse con cada parte del manual Watlow Electric Micro-Based Autotuning Control SERIES 980/985. Actualmente se preparan y traducen con dedicación, para que no solo sean comprensibles para los usuarios, sino que también cumplan su función básica de información y ayuda.
Índice de manuales de instrucciones
-
Página 1
Microprocessor-Based Auto-tuning Control ( User’s Manual) Watlow Controls, 1241 Bundy Blvd., P.O. 8ox 5580, Winona, MN 55987-5580, Phone: 507/454-5300, Fax: 507/452-4507 W985-MA58-9307 February, 1993 Supersedes: W985-MA70-9043 $10.00 Made in the U.S.A. 0 0 Printed on Recycled Paper[...]
-
Página 2
How to Use the Manual First.. Starting Out Install/Wire Front Panel Set Up Tuning Appendix NOTE: Details of a *‘Note** appear here, in the narrow box on the outside of each page. LLL CAUTION: Details of a “Caution” appear here, in the narrow box on the outside of each page. 0 WARNING: Details of a “Warning” appear here, in the narrow box [...]
-
Página 3
Chapters Figures, Table, Charts page Item page Item 4 Starting Out With The Watlow Series 980/985 4 General Description 5 Putting Your Control To Work 5 Overview of the Series 980/985 Menus Chapter 2 6 6 6 6 7 9 9 10 11 13 21 How To Install And Wire The Series 980/985 System Planning Sensor Installation Guidelines Installation Guidelines For Preven[...]
-
Página 4
Chapter 1 Flgure 1 - Series 980/985 Input and Output Overview Starting Out With The Watlow Series 9801985, A Microprocessor-Based Control Single Input - Type J, K, T, N or Pt2 Dual Outputs- PID or ON/OFF User Selectable Heat, Cool or Alarm Output 1 or 2 Percent Power Output 1, Heating Auto-tuning General Description Welcome to the Watlow Series 980[...]
-
Página 5
Putting Your Control To Work To put your Series 980/985 to work, we suggest the following steps: Read the User’s Manual. Plan your installation and wiring. Cut the panel mounting hole and install the control. Wire your Series 980/985 to the system. Start the system and tune the Series 980/985. Make final adjustments to the control parameters and [...]
-
Página 6
Chapter 2 How to Install and Wire the Series 9801985 System Planning This chapter tells you how to install the Series 980/985. All mounting and wiring information is right here. Because Watlow controls are thoroughly tested and "burned in" before leaving the factory, the Series 980/985 is ready to install when you receive it. But before y[...]
-
Página 7
Noise Sources Switches and relay contacts operating inductive loads such as motor, coils, solenoids, and relays, etc. Thyristors or other semiconductor devices which are not zero crossover-fired (randomly-fired or phase angle-fired devices). All welding machinery. Heavy current carrying conductors. Fluorescent and neon lights. How To Decrease Noise[...]
-
Página 8
• Ground loops must be eliminated in the entire control system. There are obvious loops which can be spotted by studying the"as-built" wiring diagram. There are also the not-so-obvious ground loops that result from the technique of connecting internal circuit commons in the manufacturer's equipment. An example of this would be if a[...]
-
Página 9
"Islatros" and other similar power line filters are designed to carry the power for the control circuit and “buffer” the control circuit from A.C. line noise. Devices like the lslatrol use media (electromagnetic filtering) other than electric circuits to filter out electrical noise. Take care in matching the power capabilities of the [...]
-
Página 10
Line Filtering Configurations For Controls Figure 3 - These three diagrams show you filter configurations for removing input power noise. Choose the one best suited for your system. For very dirty or critical applications - use a microcomputer-regulated power supply or Uninterruptable Power Supply (U.P.S.) Don’t fasten common mode line filters or[...]
-
Página 11
How to Install the Series 980/985 Figures 6,7 and 8 provide the Series 980/985’s panel cutout and dimensions. Do not, however, make your panel cutout until you are sure that you are placing the control in the best location. Read the noise guidelines at the beginning of this chapter before installing and wiring the Series 980/985. 1. 2. 3. 4. 5. 6[...]
-
Página 12
Figure 6 - Series 980/985 Panel Cutout Dimensions Panel Cutout Max. Panel Thickness 0.50 (12.7mm) ~ 3.82 +0.03 - 0.00 (92mm + 0.8) Load Power indicators V Panel T I .89 (48.0 mm Figure 7 - Series 980/985 Dimensions _ Adjustuble 12 WATLOW Series 9801985 User’s Manual ‘Install and Wire, Chapter 2[...]
-
Página 13
How to Wire the Series 980/985 The Series 980/985 wiring is illustrated by model number option. Check the unit sticker on the control and compare your model number to those shown here and also the model number breakdown in the back of this manual. Series 980/985 internal circuits appear “inside“ the line drawing of the 980/985, while connection[...]
-
Página 14
Figure 10 - Input Options “1”, **2* & *3’, Thermo- couple Wiring Diagram. Flgure 11 - Input Options "2" & "3" Process Input Wlring Diagram. 1 NOTE: When using a 4- 2OmA process Input, the input impedance is 2 4 9 o h m s lnput Options “1 “, “2” & “3”, Thermocouple Input Terminals 18 & 20 Model #[...]
-
Página 15
Input Options “2” & "3" RTD - 2 Wire Terminals 12 - 14 ModeI#98 _ A-2_ _0-0000 98_A-3_ _0-0000 Jumper#l3to#l4 II II . . . . . . Input Options “2” & "3" RTD - 3 Wire Terminals 12 - 14 Model# 98_ A-2_ _ 0-0000 98_A-3_ _0-0000 . . . . . . - J NOTE: Long lead lengths create electrical resistance. There will be a S 1?[...]
-
Página 16
Output 1 Option “B”, Solid State Relay Figure 14 - Solid State Relay, Output 1, Option “B” Wiring Diagram. Figure 15 - DC Output 1 (Open Collector), Option 72” Wiring Diagram. ModeI# 98_A-_ B _0-0000 Solid State Relay Solid State Relay Watlow's solid state relays change state at zero volts, which is *zero-cross switching.” They are[...]
-
Página 17
Output 1 Option “D”, 6 Amp Mechanical Relay Model#98_A-_D _0-0000 Mechanical Relay Mechanical Relay The Electromechanical relay iS an electrical and mechanical d8vice with moving parts. When power is applied to the relay solenoid, Contact closure is Created through move- ment of the “Common” Contact of the relay. Off state impedance is 2 O [...]
-
Página 18
Figure 18 - 4-2OmA, Output 1, Option "F" Wiring Diagram. Figure 19 - 0-20mA, Output 1, Option “G” Wiring Diagram. Output 1 Option “F", 4-20mA Model# 98_A-_F _0-0000 Process Output Proportional value determined by the control to balance the sensor input and set point. This value will fall between 4-20mA depending on your process[...]
-
Página 19
Output 1 Option “H”, O-5VDC Model# 98_A-_H _0-0000 Process Output Proportional value determined by the control to balance the sensor input and set point. This value will fall between O-5VDC dependlng on your process output type. Output 2 Option “B”, Solid State Relay Model# 98_A- B 0-0000 -- Solid State Relay Watlow’s solid state relays c[...]
-
Página 20
Figure 22 - DC Output (Open Collector), output 2 Option "C" Wiring Diagram. Figure 23 - 6 Amp Mechanical Relay, Output 2, Option "D" Wiring Diagram. Output 2 Option “C", DC Output (Open Collector) Model# 98_A- C 0-0000 __ - . . . . . . . ’ 9 - 8 Heat, Cool + # or Alarm Switched DC Watlow’s solid state switch is a low [...]
-
Página 21
n T 0 WARNING: Install high or low temperature limit control protection in systems where an overtemperature fault condition could present a fire hazard or other hazard. Failure to install temperature limit control protection where a potential hazard exists could result in damage to equipment and property, and injury to personnel. 0 1 CAUTION: Do no[...]
-
Página 22
Chapter 3 1 NOTE: The Upper display will always show the process value after 1 minute without key strokes. Figure 25 - Series 980/985 Displays How to Use the Keys and Displays Series 980/985 Displays and Load LED’s Upper Display Red, 0.3” high LED, seven segment, three or four digit display indicating either process actual tem- perature, the op[...]
-
Página 23
Series 980/985 Keys Figure 27 - Series 980/985 Keys UP/DOWN keys MODE Key When pressed simultaneously for 3 sec- Steps the control through the onds, the Setup Menu appears displaying Operating menu; also, in the the LOC parameter. From the LOC pa- Auto mode, enters new data rameter, press the UP/DOWN keys again selected less than 5 seconds and the [...]
-
Página 24
Chapter 4 1 NOTE: While in the Setup menu, all outputs are OFF. Figure 27 - Entering the Setup Menu. Figure 28 - The Setup Menu. an NOTE: When using a process input such as O-5VDC or 4-2OmA, the rL and rH settings scale the display to match the measured range of the process signal. How To Setup The Series 9801985 Setting up the Series 980/985 is a [...]
-
Página 25
Setup Parameters At the top of the menu, the Series 980/985 displays the user level of operation in the Upper display, and the LOC parameter in the Lower display. When pressing the MODE key, the value of the next parameter appears in the Upper display, and the parameter itself is in the Lower display. Lock: Selects the level of operator lock-out. T[...]
-
Página 26
Latching: Selects whether the output is latching or non-latching when Output 2 is an alarm. Latching alarms must be cleared before the alarm output will reset. Non-latching automatically resets the alarm output when the condition clears. The range is LAt or nLA, default is nLA. This only appears if the Ot2 = AL. Silencing: Selects alarms silencing [...]
-
Página 27
m Mode Key + Control Set Point J NOTE: The Upper display will always show the process value after 1 minute without key strokes. = Prompt appears or not according to control configuration. 1 g.f$fygj [!I . Operation Parameters Set Point 2: Sets the operating set point for Output 2 when control mode is Ht/ Ht or CL/CL. SP2 only appears when Ot1 and 0[...]
-
Página 28
Chart 3 - Operation Menu Prompts and Descriptions. Dead Band: Enter the Dead Band between the heating and cooling functions adjustable from ± 99°F/± 55°C. The default is 0°. Appears when Ot2 = CL. Alarm Low: Represents the low process alarm or low deviation alarm. Displayed only when 0t2 parameter is AL. Alarm High: Represents the high process[...]
-
Página 29
Chapter 5 How to Tune and Operate Tuning - Automatic Auto-tuning: The Series 9801985 gives you the capability to automatically tune the PlD parameters to fit the characteristics of your particular thermal system. The auto-tuning procedure operates on a thermal response value - slow, medium, or fast. A slow thermal response is used when the process [...]
-
Página 30
Tuning - Manual For optimum control performance, tune the Series 985 to the thermal system The tuning settings here are meant for a broad spectrum of applications; your system may have somewhat different requirements. 1. 2. 3. 4. 5. 6. Apply power to the Series 965 and enter a set point. Begin with these Operation Parameters: Pbl = 1, rE1 = 0.00, r[...]
-
Página 31
Indication of Auto/Manual operation is the LED located on the AUTO/MAN key. When the LED is ON, the control is in the Manual operation, an alarm condition is present, and the output de-energizes. When the LED is OFF, the control is in AUTO operation and the alarm is energized. When the LED flashes, press the key again within five seconds to complet[...]
-
Página 32
Press ~ twice- Read error Figure 32 - Error Code Display Examples J NOTE: Electrical noise or a noise event, vibra- tion or excess environmental moisture or tem- perature may cause Series 985 errors to occur. If the cause of an error is not otherwise apparent, check for these. •If the alarm is non-latching... The alarm will clear itself automatic[...]
-
Página 33
Er 1, 2, 3 & 7 Errors - Control Outputs May Be ON If operator access is LOC 0 or 1 . . . . ..and the control was in AUTO operation when the error occurred, it will go into MANUAL (% power) operation. If the output power is less than 70%±5% change within the last two minutes, the 985 will switch into Manual operation at the last Automatic power[...]
-
Página 34
Appendix Control Mode • Single set point, non-ramping. l Single input, dual outputs. l Control outputs: User selectable as: Heat, Heat/Heat, Heat/Cool, Cool, Cool/Cool, Heat/Alarm, Cool/Alarm l Outputs independent, or related via deadband for Heat/Cool. l ON/OFF: 3°F or 1 .7°C switching hysteresis or 0.3°F or 0.l7°C for 0.10 Units . l PID par[...]
-
Página 35
Primary Output (Heating or Cooling) l Solid state relay, 0.5A @ 24VAC minimum, 253VAC maximum, opto- isolated, zero cross switching. l Electromechanical relay, Form C, 6A @ 115/230VAC, 6A @ 28VDC, 1/8 hp. @ 115VAC 125VA @ 115VAC. Warranted to 100,000 cycles. l Open collector, switched DC signal provides a minimum turn ON voltage of 3VDC into a mini[...]
-
Página 36
Series 980/985 Model Number Information The Series 980/985 Model Number, listed on your unit sticker, is defined below. ,918 ‘ Control Series 980/985 = Dual output, microprocessor-based I/8 DIN Mounting 0 = Horizontal 5 = Vertical Input 1 = 2 = 3 = Type J thermocouple (3 digit only) Type J, K, T, N, PT 2 thermocouple; RTD 1°, 420mA, 0-5VDC (4 di[...]
-
Página 37
Calibration Menu In the Calibration Menu, various input signals must be supplied in order for the control to go through its auto calibration. The calibration menu can only be entered from the LOC parameter in the Setup menu. Press the UP/DOWN keys simultaneously for 3 seconds (± 1 second). The CAL parameter appears. Any inadvertent change in displ[...]
-
Página 38
Figure 34 - The Calibration Menu. k NOTE Before calibration on an installed control, make sure all data and parameters are documented. See Setup and Operation Charts, Pages 26 and 28. J3 NOTE: Not all parameters will appear. They are dependent on your unit type. Use only the steps that apply to your unit. tcL tcH t A 4A0 t Thermocouple Field Calibr[...]
-
Página 39
RTD Field Calibration Procedure Equipment Required l 1K ohm precision decade resistance box with 0.01 ohms resolution. Setup And Calibration ar NOTE Before calibration on an installed control, make sure all data and parameters are documented. See Setup and Operation Charts, Pages 26 and 28. 1. Connect the AC line voltage L1 to Terminal #4, L2 to Te[...]
-
Página 40
J-3 NOTE: Not all parameters will appear. They are dependent on your unit type. Use only the steps that apply to your unit. 0 - 5 Volt Field Calibration Procedure Equipment Required l Precision voltage source 0-5 volt minimum range with 0.001 volt resolution. Setup And Calibration aI NOTE 1. 2. 3. Before calibration on an installed control, make su[...]
-
Página 41
4-20mA Input Field Calibration Procedure Equipment Required l Precision current source 0-20mA minimum range with 0.01 mA resolution. Setup And Calibration 1 NOTE J NOTE: Not all parameters will appear. They are dependent on Before calibration on an installed control, make sure all data and your unit type. Use parameters are documented. See Setup an[...]
-
Página 42
0-20/4-20mA Output Field Calibration Procedure J3 NOTE Not all parameters will appear. They are dependent on your unit type. Use only the steps that apply to your unit. Equipment Required l 470 ohm 1/2 watt 10% resistor. l 4 - 1/2 digit Digital Multimeter. Setup And Calibration J NOTE 1. 2. 3. Before calibration on an installed control, make sure a[...]
-
Página 43
0-5/0-10 Volt Output Field Calibration Procedure Equipment Required l 20K ohm, 1/4 watt, 10% resistor l 4 - 1/2 digit Digital Multimeter. Setup And Calibration 1 NOTE R NOTE: Not all parameters will appear. They are dependent on your unit type. Use only the steps that apply to your unit. 1. 2. 3. Before calibration on an installed control, make sur[...]
-
Página 44
Alarm: A condition, generated by a controller, Droop: Difference in temperature between set indicating that the process has exceeded or fallen point and stabilized process temperature. below the set or limit point. Duty cycle: Percentage of “load ON time” Anti-reset: Control feature that inhibits auto- matic reset action outside of the proporti[...]
-
Página 45
PD control: Proportioning control with rate action. PI control: Proportioning control with auto-reset. PID control: Proportioning control with auto- reset and rate. Process varlable: Thermal system element to be regulated, such as time, temperature, relative humidity, etc. Programmed display data: Displayed informa- tion which gives the operator/pr[...]
-
Página 46
A Appendi x , 34 AUTO/MAN key, 23 Automatic Operation, 23,31 Auto-tuning, 30 K, L Keys, 23, Fig. 27 Line Filtering Configurations, 10 Local-Remote Set Point, 25,28 ’ B Bumpless transfer, 31 Lower Display, 22, Fig. 25 M C Calibration, 38 Combination Differential Filter, 10, Fig. 5 Common Mode Fitter Wiring, 10, Fig 4 D DCOutput 1, 16, Fig.16 DC Ou[...]
-
Página 47
Warranty The Watlow Series 980/985 is warranted to be free of defects in material and workmanship for 36 months after delivery to the first purchaser for use, provid- ing that the units have not been misapplied. Since Watlow has no control over their use, and sometimes misuse, we cannot guarantee against failure. Wat- low’s obligations hereunder,[...]