Empire Comfort Systems FAW-40-1IP manuel d'utilisation
- Voir en ligne ou télécharger le manuel d’utilisation
- 36 pages
- 0.94 mb
Aller à la page of
Les manuels d’utilisation similaires
-
Furnace
Empire Comfort Systems 5088-3
12 pages 0.17 mb -
Furnace
Empire Comfort Systems GWT-50-2
20 pages 1.11 mb -
Furnace
Empire Comfort Systems 7088-3
12 pages 0.17 mb -
Furnace
Empire Comfort Systems DV-210-7SG
20 pages 0.7 mb -
Furnace
Empire Comfort Systems DV-55T-1
20 pages 0.92 mb -
Furnace
Empire Comfort Systems RB)
20 pages 1.11 mb -
Furnace
Empire Comfort Systems FAW-40-1IP
18 pages 0.74 mb -
Furnace
Empire Comfort Systems 3588-3
12 pages 0.17 mb
Un bon manuel d’utilisation
Les règles imposent au revendeur l'obligation de fournir à l'acheteur, avec des marchandises, le manuel d’utilisation Empire Comfort Systems FAW-40-1IP. Le manque du manuel d’utilisation ou les informations incorrectes fournies au consommateur sont à la base d'une plainte pour non-conformité du dispositif avec le contrat. Conformément à la loi, l’inclusion du manuel d’utilisation sous une forme autre que le papier est autorisée, ce qui est souvent utilisé récemment, en incluant la forme graphique ou électronique du manuel Empire Comfort Systems FAW-40-1IP ou les vidéos d'instruction pour les utilisateurs. La condition est son caractère lisible et compréhensible.
Qu'est ce que le manuel d’utilisation?
Le mot vient du latin "Instructio", à savoir organiser. Ainsi, le manuel d’utilisation Empire Comfort Systems FAW-40-1IP décrit les étapes de la procédure. Le but du manuel d’utilisation est d’instruire, de faciliter le démarrage, l'utilisation de l'équipement ou l'exécution des actions spécifiques. Le manuel d’utilisation est une collection d'informations sur l'objet/service, une indice.
Malheureusement, peu d'utilisateurs prennent le temps de lire le manuel d’utilisation, et un bon manuel permet non seulement d’apprendre à connaître un certain nombre de fonctionnalités supplémentaires du dispositif acheté, mais aussi éviter la majorité des défaillances.
Donc, ce qui devrait contenir le manuel parfait?
Tout d'abord, le manuel d’utilisation Empire Comfort Systems FAW-40-1IP devrait contenir:
- informations sur les caractéristiques techniques du dispositif Empire Comfort Systems FAW-40-1IP
- nom du fabricant et année de fabrication Empire Comfort Systems FAW-40-1IP
- instructions d'utilisation, de réglage et d’entretien de l'équipement Empire Comfort Systems FAW-40-1IP
- signes de sécurité et attestations confirmant la conformité avec les normes pertinentes
Pourquoi nous ne lisons pas les manuels d’utilisation?
Habituellement, cela est dû au manque de temps et de certitude quant à la fonctionnalité spécifique de l'équipement acheté. Malheureusement, la connexion et le démarrage Empire Comfort Systems FAW-40-1IP ne suffisent pas. Le manuel d’utilisation contient un certain nombre de lignes directrices concernant les fonctionnalités spécifiques, la sécurité, les méthodes d'entretien (même les moyens qui doivent être utilisés), les défauts possibles Empire Comfort Systems FAW-40-1IP et les moyens de résoudre des problèmes communs lors de l'utilisation. Enfin, le manuel contient les coordonnées du service Empire Comfort Systems en l'absence de l'efficacité des solutions proposées. Actuellement, les manuels d’utilisation sous la forme d'animations intéressantes et de vidéos pédagogiques qui sont meilleurs que la brochure, sont très populaires. Ce type de manuel permet à l'utilisateur de voir toute la vidéo d'instruction sans sauter les spécifications et les descriptions techniques compliquées Empire Comfort Systems FAW-40-1IP, comme c’est le cas pour la version papier.
Pourquoi lire le manuel d’utilisation?
Tout d'abord, il contient la réponse sur la structure, les possibilités du dispositif Empire Comfort Systems FAW-40-1IP, l'utilisation de divers accessoires et une gamme d'informations pour profiter pleinement de toutes les fonctionnalités et commodités.
Après un achat réussi de l’équipement/dispositif, prenez un moment pour vous familiariser avec toutes les parties du manuel d'utilisation Empire Comfort Systems FAW-40-1IP. À l'heure actuelle, ils sont soigneusement préparés et traduits pour qu'ils soient non seulement compréhensibles pour les utilisateurs, mais pour qu’ils remplissent leur fonction de base de l'information et d’aide.
Table des matières du manuel d’utilisation
-
Page 1
12427-2-0903 Page 1 INST ALLA TION INSTRUCTIONS AND OWNER'S MANUAL F AN TYPE VENTED WALL FURNACE MODEL F A W -40-1SPP F A W -40-1IP EFFECTIVE DA TE SEPTEMBER 2003 WARNING: If the information in this manual is not followed exactly , a fir e or explosion may result causing pr operty damage, personal injury or loss of life. — Do not store or us[...]
-
Page 2
12427-2-0903 Page 2 The base referred to above does not mean the fire-proof base as used on wood stoves. The protection is for rugs that are extremely thick and light colored tile. Installation in Residential Garages Gas utilization equipment in residential garages shall be installed so that all burners and burner ignition devices are located not l[...]
-
Page 3
12427-2-0903 Page 3 Some people cannot smell well. Some people cannot smell the odor of the chemical stench put into the gas. You must find out if you can smell the odorant in propane. Smoking can decrease your ability to smell. Being around an odor for a time can affect your sensitivity or ability to detect that odor. Some- times other odors in th[...]
-
Page 4
12427-2-0903 Page 4 furnace opening confined space Figure 1 Outdoor Air Outlet and inlet air can be brought into the confined space via openings into a ventilated attic and ventilated crawl space. furnace ou tl e t ai r inlet air attic ventilation louvers cra wl space ventilation louver s Figure 2 Confined Space Outdoor Air Using Vertical or Horizo[...]
-
Page 5
12427-2-0903 Page 5 C. 4 " (102mm) Oval In-The-Wall (all parts purchase locally) 1. Type B-1 oval pipe or B-W vent pipe 2. Type B-1 oval elbows or B-W oval elbows 3. Single story type B-1 or (B-W) gas vents require a baseplate and one pair of ceiling plate spacers. 4. Multi-story type B-1 or (B-W) gas vents require a baseplate, one pair of cei[...]
-
Page 6
12427-2-0903 Page 6[...]
-
Page 7
12427-2-0903 Page 7 8. Align clearance holes on 6" x 10" (152mm x 254mm) duct with screw holes on inner casing back and mark duct to be 2 1/4" (57mm) shorter than 8" x 12" (203mm x 305mm) boot. Remove duct and cut to proper length. 9 . Attach 6" x 10" (152mm x 254mm) duct to inner casing back with (4) # 8 x 3/8&qu[...]
-
Page 8
12427-2-0903 Page 8 Attention! If one of the above procedures results in pressures in excess of 1/2 psig (14" w.c.) (3.5 kPa) on the appliance gas valve, it will result in a hazardous condition. Checking Manifold Pressure Both Propane and Natural gas valves have a built-in pressure regulator in the gas valve. Natural gas models will have a man[...]
-
Page 9
12427-2-0903 Page 9 Oiling the Motor The fan motor should be cleaned and oiled once each heating season. Oil holes are located on the top at each end of the motor. Use a few drops of #10 motor oil. To clean the motor, blow air through its ventilation openings with a vacuum cleaner or low pressure air source. Wiring The appliance, when installed, mu[...]
-
Page 10
12427-2-0903 Page 10 SERVICE AND MAINTENANCE SUGGESTIONS CALL SERVICEMAN GENERAL: All furnaces have been fire-tested to check for proper operation. This includes, main burner flame, pilot flame, fan operation, fan control, limit control and automatic valve operation. If the furnace fails to function on initial installation, it is advisable to re-ch[...]
-
Page 11
12427-2-0903 Page 11 FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly. B. BEFORE LIGHTING smell[...]
-
Page 12
12427-2-0903 Page 12 FOR YOUR SAFETY READ BEFORE OPERA TING WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This appliance is equipped with an ignition device which automatically lights the pilot. Do not try to light the pilot by hand. B. BEFORE OP[...]
-
Page 13
12427-2-0903 Page 13 ST AR T System Check END SEQUENCE OF OPERA TION T rial for Ignition Main Burner Operation Apply 24 V AC to Appliance Thermostat Calls for Heat Flame Signal Detected Internal Check OK • Pilot V alve Opens • Ignitor Powered Pilot Light and Flame is Sensed During T rial For Ignition (1) • Ignitor OFF • Main V alve Opens Fl[...]
-
Page 14
12427-2-0903 Page 14 SmartV alve ™ System T roubleshooting Sequence Note: Before T roubleshooting, Become Familiar with the Sequence of Operation IP SYSTEM TROUBLESHOOTING SEQUENCE NO NO NO YES YES NO • T urn OFF Gas Supply • Disconnect System Control Harness • Set Thermostat to Call for Heat Plug Harness into SmartV alve Control W ait for [...]
-
Page 15
12427-2-0903 Page 15 INDEX PART NO. NUMBER DESCRIPTION INDEX PART NO. NUMBER DESCRIPTION PLEASE NOTE: When ordering parts, it is very important that part number and description of part coincide. 1 WFA-115 GASKET - HEADER 2 DV-1247 TOP PLATE (USA) 2 15668 TOP PLATE (CANADA) 3 R-3165 DOOR CLIP (2 REQUIRED) 4 DV-1204 CASING SIDE - RIGHT 5 DV-1203 CASI[...]
-
Page 16
12427-2-0903 Page 16[...]
-
Page 17
12427-2-0903 Page 17 Service Notes[...]
-
Page 18
12427-2-0903 Page 18 Empire Comfort Systems, Inc. Nine Eighteen F reeburg A ve . Belle ville, Illinois 62220-2623 PH: 1-618-233-7420 PH: 1-800-851-3153 F AX: 1-618-233-7097 F AX: 1-800-443-8648 E-MAIL: inf o@empirecomfor t.com WEB SITE: www .empirecomf or t.com[...]
-
Page 19
12427(F)-2-0903 Page 1 INSTRUCTIONS POUR L ’INST ALLA TION ET MANUEL DU PROPRIÉT AIRE RADIA TEUR MURAL À CIRCULA TION FORCÉE ET A VEC ÉV ACUA TION MODÈLE F A W -40-1SPP F A W -40-1IP DA TE D’ENTRÉE EN VIGUEUR SEPTEMBRE 2003 AVERTISSEMENT: Si les informations dans ce manuel ne sont pas exactement suivies, un feu ou une explosion peut en r?[...]
-
Page 20
12427(F)-2-0903 Page 2 Introduction Toujours consulter le département de construction de votre région en ce qui regarde les règlements, les codes ou les ordonnances qui s’appliquent à l’installation d’un radiateur mural avec évacuation. Instructions pour l'Installateur 1. Après l’installation, l’installateur doit laisser le man[...]
-
Page 21
12427(F)-2-0903 Page 3 INFORMATION DE SÉCURITÉ POUR LES UTILISATEURS DE PROPANE Le propane est un gaz inflammable qui peut causer des feux et des explosions. Dans son état naturel, le propane est inodore et sans couleur. Peut-être que vous ne connaissez pas toutes les précautions décrites ci-dessous? Elles peuvent vous protéger ainsi que vot[...]
-
Page 22
12427(F)-2-0903 Page 4 ATTENTION: L’air de combustion ne doit pas provenir d’un espace chauffé lequel inclus des ventilateurs soufflants, foyers ou d’autres appareils qui peuvent produire une pression négative dans l’espace. furnace opening confined space Figure 1 Air Extérieur L’entrée et la sortie d’air peuvent être apportées da[...]
-
Page 23
12427(F)-2-0903 Page 5 B. BRAC KET BASEPLATE 4 " B- 1 OVAL C. BASEPL A TE SPACER 4" B-1 OVAL 4" 45 DEG. O V AL ELBOW S C. SPACER BASEPL A TE 4" B-1 OVAL A. VENT ENC LOSURE AD APTER BASEPL A TE SI DE FRONT 4" ROUN D WALL Figure 4 B. Ovale de 4" (102mm) (toutes les pièces peuvent être achetées localement) 1 . Tuyau ov[...]
-
Page 24
12427(F)-2-0903 Page 6 Pour installer le SOK-1, s’il vous plaît utilisé les étapes 1 jusqu’à 5 dans les instructions du SOR-1 pour les radiateurs FAW-40. Maintenant, utiliser les étapes suivantes pour compléter l’installation du SOK-1. 1. En utilisant les trémies intérieurs et extérieurs comme guide pour les trous, marquer et percer [...]
-
Page 25
12427(F)-2-0903 Page 7 arrière pour former un carré. Percer un trou pilote à l’intérieur du carré que vous avez tracé sur la paroi extérieure arrière. Enlever la feuille de métal à l’intérieur du carré que vous avez tracé, avec des ciseaux à métal ou un outil comparable. 3. Enlever les (4) vis # 8 x 3/8" (9mm) qui attachent [...]
-
Page 26
12427(F)-2-0903 Page 8 Figure 8 Méthode pour installer un collecteur de sédiment avec un adapteur en T L’emploi des connexions de gaz suivantes est recommandé. — ANS Z21.24 Connexions d’appareil de tuyaux et de raccords en métal ondulé. — ANS Z21.45 Connexions flexibles d’appareil autre qu’en métal. Les connexions ci-dessus peuven[...]
-
Page 27
12427(F)-2-0903 Page 9 sources de chaleur (cuisinière, chauffe-eau, etc.) incluant les murs ou encadrements de porte ayant une source de chaleur dans la pièce avoisinante. Ne pas installer le thermostat sur un mur extérieur. L’Enceinte de l’Évent Isolée Les radiateurs muraux avec un évent, installés dans des bâtiments ayant un toit plat[...]
-
Page 28
12427(F)-2-0903 Page 10 Figure 13 BU RNER BOX GAS VAL VE J UNC TION BOX- TRANS FORMER LIMIT SWITCH FAN SWITCH VENT LIMIT SW ITCH FLUE CONNECTOR FAN PI EZO I GNITOR DRAFT DIVERTER Figure 14 SUGGESTIONS POUR LE SERVICE ET L’ENTRETIEN. Appeler un technicien d’entretien. Général : Tous les radiateurs ont reçu un test d’allumage pour vérifier [...]
-
Page 29
12427(F)-2-0903 Page 11 Veilleuse modèle IP Ce radiateur utilise un système “Smart Valve” Honeywell pour l’allumage intermittent de la veilleuse. Lors d’un appel de chaleur par le thermostat, cette commande fera fonctionner la mini surface chaude d’allumage laquelle allumera la veilleuse qui elle à son tour allumera le brûleur princip[...]
-
Page 30
12427(F)-2-0903 Page 12 1. Arrêter! Lire les informations de sécurité ci-dessus. 2. Mettre le thermostat à son plus bas réglage. 3. Éteindre tout pouvoir électrique à l’appareil. 4. Enlever le panneau d’accès au contrôle (panneau du bas avant). 5. Tourner le bouton de contrôle de gaz dans le sens des aiguilles d’une montre à la po[...]
-
Page 31
12427(F)-2-0903 Page 13 1. Arrêter! Lire les informations de sécurité ci-dessus. 2. Mettre le thermostat à son plus bas réglage. 3. Éteindre tout pouvoir électrique à l’appareil. 4. Cet appareil est muni d’un dispositif d’allumage lequel allume automatiquement la veilleuse. Ne pas essayer d’allumer la veilleuse manuellement. ON OF F[...]
-
Page 32
12427(F)-2-0903 Page 14 D é part V é rification du Syst è me FIN S é quence de Fonctionnement Essai d'Allumage Fonctionnement du Br û leur Principal Appliquer 24 V AC à l'appareil Thermostat Effectue un Appel de Chaleur Signal de la Flamme est D é tect é V é rification Interne OK • Soupage de la V eilleuse s'ouvre • Allu[...]
-
Page 33
12427(F)-2-0903 Page 15 Guide de d é tection des d é fectuosit é s pour le syst è me "Smart V alve" Note: A vant que les d é fectuosit é s apparaissent, familiarisez-vous avec les s é quences de defonctionnement. Guide de D é tection des D é fectosit é s pour le Syst è me IP NON NON NON OUI OUI NON • Fermer l'Alimentatio[...]
-
Page 34
12427(F)-2-0903 Page 16 Index Part No. Number Description Index Part No. Number Description PLEASE NOTE: When ordering parts, it is very important that part number and description of part coincide. 1 WFA-115 Joint d ’é tanch é it é 2 DV-1247 Plaque du dessus (USA) 2 15668 Plaque du dessus (CANADA) 3 R-3165 Agrafe pour la porte (exige 2) 4 DV-1[...]
-
Page 35
12427(F)-2-0903 Page 17[...]
-
Page 36
12427(F)-2-0903 Page 18 Empire Comfort Systems, Inc. Nine Eighteen F reeburg A ve . Belle ville, Illinois 62220-2623 PH: 1-618-233-7420 PH: 1-800-851-3153 F AX: 1-618-233-7097 F AX: 1-800-443-8648 E-MAIL: inf o@empirecomfor t.com WEB SITE: www .empirecomf or t.com[...]