Empire Comfort Systems GP)-1 manuel d'utilisation
- Voir en ligne ou télécharger le manuel d’utilisation
- 56 pages
- 4.56 mb
Aller à la page of
Les manuels d’utilisation similaires
-
Indoor Fireplace
Empire Comfort Systems DVP48FP9(1,3)(N,P)-1
56 pages 3.59 mb -
Indoor Fireplace
Empire Comfort Systems DVP42FP3(0,1,2,3)(N,P)-1
56 pages 3.59 mb -
Indoor Fireplace
Empire Comfort Systems VFD42FB2CL-1
20 pages 4.96 mb -
Indoor Fireplace
Empire Comfort Systems 21)L(N
28 pages 1.93 mb -
Indoor Fireplace
Empire Comfort Systems PV-28SV50-B2H(N,P)-1
56 pages 3.7 mb -
Indoor Fireplace
Empire Comfort Systems VFP36SP32EP-2
40 pages 7.6 mb -
Indoor Fireplace
Empire Comfort Systems VF24FP3-1
28 pages 3.02 mb -
Indoor Fireplace
Empire Comfort Systems VFHS-20/10T-4
28 pages 2.84 mb
Un bon manuel d’utilisation
Les règles imposent au revendeur l'obligation de fournir à l'acheteur, avec des marchandises, le manuel d’utilisation Empire Comfort Systems GP)-1. Le manque du manuel d’utilisation ou les informations incorrectes fournies au consommateur sont à la base d'une plainte pour non-conformité du dispositif avec le contrat. Conformément à la loi, l’inclusion du manuel d’utilisation sous une forme autre que le papier est autorisée, ce qui est souvent utilisé récemment, en incluant la forme graphique ou électronique du manuel Empire Comfort Systems GP)-1 ou les vidéos d'instruction pour les utilisateurs. La condition est son caractère lisible et compréhensible.
Qu'est ce que le manuel d’utilisation?
Le mot vient du latin "Instructio", à savoir organiser. Ainsi, le manuel d’utilisation Empire Comfort Systems GP)-1 décrit les étapes de la procédure. Le but du manuel d’utilisation est d’instruire, de faciliter le démarrage, l'utilisation de l'équipement ou l'exécution des actions spécifiques. Le manuel d’utilisation est une collection d'informations sur l'objet/service, une indice.
Malheureusement, peu d'utilisateurs prennent le temps de lire le manuel d’utilisation, et un bon manuel permet non seulement d’apprendre à connaître un certain nombre de fonctionnalités supplémentaires du dispositif acheté, mais aussi éviter la majorité des défaillances.
Donc, ce qui devrait contenir le manuel parfait?
Tout d'abord, le manuel d’utilisation Empire Comfort Systems GP)-1 devrait contenir:
- informations sur les caractéristiques techniques du dispositif Empire Comfort Systems GP)-1
- nom du fabricant et année de fabrication Empire Comfort Systems GP)-1
- instructions d'utilisation, de réglage et d’entretien de l'équipement Empire Comfort Systems GP)-1
- signes de sécurité et attestations confirmant la conformité avec les normes pertinentes
Pourquoi nous ne lisons pas les manuels d’utilisation?
Habituellement, cela est dû au manque de temps et de certitude quant à la fonctionnalité spécifique de l'équipement acheté. Malheureusement, la connexion et le démarrage Empire Comfort Systems GP)-1 ne suffisent pas. Le manuel d’utilisation contient un certain nombre de lignes directrices concernant les fonctionnalités spécifiques, la sécurité, les méthodes d'entretien (même les moyens qui doivent être utilisés), les défauts possibles Empire Comfort Systems GP)-1 et les moyens de résoudre des problèmes communs lors de l'utilisation. Enfin, le manuel contient les coordonnées du service Empire Comfort Systems en l'absence de l'efficacité des solutions proposées. Actuellement, les manuels d’utilisation sous la forme d'animations intéressantes et de vidéos pédagogiques qui sont meilleurs que la brochure, sont très populaires. Ce type de manuel permet à l'utilisateur de voir toute la vidéo d'instruction sans sauter les spécifications et les descriptions techniques compliquées Empire Comfort Systems GP)-1, comme c’est le cas pour la version papier.
Pourquoi lire le manuel d’utilisation?
Tout d'abord, il contient la réponse sur la structure, les possibilités du dispositif Empire Comfort Systems GP)-1, l'utilisation de divers accessoires et une gamme d'informations pour profiter pleinement de toutes les fonctionnalités et commodités.
Après un achat réussi de l’équipement/dispositif, prenez un moment pour vous familiariser avec toutes les parties du manuel d'utilisation Empire Comfort Systems GP)-1. À l'heure actuelle, ils sont soigneusement préparés et traduits pour qu'ils soient non seulement compréhensibles pour les utilisateurs, mais pour qu’ils remplissent leur fonction de base de l'information et d’aide.
Table des matières du manuel d’utilisation
-
Page 1
Page 1 INST ALLA TION INSTRUCTIONS AND OWNER’S MANUAL M a n tis P o w e r H u m i d i f i e r B u r n e r s E x h a u s t F a n B l o w e r H i M e d L o w F r o n t R e a r POWER-VENT HIGH-EFFICIENCY FIREPLACE WITH BA Y WINDOW MODELS PV -28SV50-(BN,BP)-1 PV -28SV55-(CN,CP ,GN,GP)-1 W ARNING: If not installed, operated and main- tained in accorda[...]
-
Page 2
22618-17-0308 Page 2 T ABLE OF CONTENTS Important Safety Information ......................................................................................................................................... 3 Safety Information for Users of LP-Gas ......................................................................................................[...]
-
Page 3
22618-17-0308 Page 3 IMPOR T ANT SAFETY INFORMA TION THIS IS A HEA TING APPLIANCE DO NOT OPERA TE THIS APPLIANCE WITHOUT FRONT P ANEL INST ALLED. • Due to high temperatures the appliance should be lo- cated out of traffic and away from furniture and draper- ies. • Children and adults should be alerted to the hazards of high surface temperature[...]
-
Page 4
22618-17-0308 Page 4 SAFETY INFORMA TION FOR USERS OF LP-GAS Propane (LP-Gas) is a flammable gas which can cause fires and explosions. In its natural state, propane is odorless and colorless. Y ou may not know all the following safety precautions which can protect both you and your family from an accident. Read them carefully now , then review th[...]
-
Page 5
22618-17-0308 Page 5 REQUIREMENTS FOR MASSACHUSETTS For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole or in part for residential purposes, including those owned or operated by the Commonwealth and where the side wall exhaust vent termination is less than seven (7) feet above [...]
-
Page 6
22618-17-0308 Page 6 Consult the current National Fuel Gas Code, ANSI Z223.1 CAN/ CGA-B149 (.1 or .2) installation code. Recommended Gas Pipe Diameter Pipe Length Schedule 40 Pipe Inside Diameter T ubing, T ype L Outside Diameter Nat. L.P . Nat. L.P . 0-10 feet 0-3 meters 1/2” 12.7mm 3/8” 9.5 mm 1/2” 12.7mm 3/8” 9.5 mm 10-40 feet 4-12 meter[...]
-
Page 7
22618-17-0308 Page 7 Qualified Installing Agency Installation and replacement of gas piping, gas utilization equip- ment or accessories and repair and servicing of equipment shall be performed only by a qualified agency . The term “qualified agen- cy” mean any individual, firm, corporation or company which either in person or through a repr[...]
-
Page 8
22618-17-0308 Page 8 Model PV28SV50 Input BTU/HR (KW/H) 19,000 Rear - 9,000 Front Height 25 1/8” W idth 28 3/16” Depth 17 5/8” Gas Inlet (Pipe) 3/8” Flair Electrical - Unit has a 5’ (1.5 m) 3 pronged cordset for con- nection to an approved 1 15 V AC 60 Hz maximum AMPs - 5A wall receptacle. Accessories Part Number Description PV -2H T op C[...]
-
Page 9
22618-17-0308 Page 9 1. Pick a location on a wall with a clear space in the room. In selecting a location for installation, it is necessary to provide adequate accessibility clearances for servicing and proper installation. Be sure to locate the unit close enough to a 1 10 V AC wall receptacle to properly power appliance. 2. When facing the front o[...]
-
Page 10
22618-17-0308 Page 10 1. Pick a location on a wall with a clear space in the room. In selecting a location for installation, it is necessary to provide adequate accessibility clearances for servicing and proper installation. Be sure to locate the unit close enough to a 1 15 V AC wall receptacle to properly power appliance. 2. When facing the front [...]
-
Page 11
22618-17-0308 Page 1 1 SPECIFICA TIONS Heater with Pedestal and Single Flue Adaptor 1 Flue Outlet 1 1/2” PVC Pipe 2 Air Inlet 3 Electric Cord 4 3/8” Flare Connection (Inside) 5 Single Flue Adaptor Model #PVVK-SH (required) Figure 3[...]
-
Page 12
22618-17-0308 Page 12 SPECIFICA TIONS - (continued) Figure 4 Heater without pedestal 1 Flue Outlet 1 1/2” PVC Pipe 2 Air Inlet 3 Electric Cord 4 3/8” Flare Connection (Inside) 5 Single Flue Adaptor Model #PVVK-SH (required)[...]
-
Page 13
22618-17-0308 Page 13 SPECIFICA TIONS - (continued) Figure 5 Fireplace Insert with Mantel Surr ound with Slim T op Panel 1 Flue Outlet 1 1/2” PVC Pipe 2 Air Inlet 3 Electric Cord 4 3/8” Flare Connection (Inside) 5 Single Flue Adaptor Model #PVVK-SH (Required) 6 Surround Model #PVE-1 7 T op Cover Kit, Slim Model #PV2H Caution: Do not block louve[...]
-
Page 14
22618-17-0308 Page 14 SPECIFICA TIONS - (continued) Figure 6 Fireplace Insert with Mantel Surr ound with Short T op Panel 1 Flue Outlet 1 1/2” PVC Pipe 2 Air Inlet 3 Electric Cord 4 3/8” Flare Connection (Inside) 5 Single Flue Adaptor Model #PVVK-SH (Required) 6 Surround Model #PVE-1 8 T op Cover Kit, Short Model #PV4H Caution: Do not block lou[...]
-
Page 15
22618-17-0308 Page 15 CLEARANCE TO COMBUSTIBLES Freestanding Models Freestanding Units A Rear W all to Heater 0” (2” Single Flue and 1 1/4” Direct V ent for Serviceability) B Side W all to Heater 0” (4” recommended for serviceability) C Corner Installation 0” D Mantel Clearance See Figure 1 1 Fireplace Insert Note: The Mantis Power-V en[...]
-
Page 16
22618-17-0308 Page 16 ROUGH FRAMING DIMENSIONS INSER T INT O MASONR Y FIREPLACE A - 13 /34” MIN. CO-LINEAR 8 1/2” WHEN USING DIRECT VENTING PVVK-24H/PVVK-48H NOTE: DIMENSIONS FOR USE WITH SHOR T TOP PV4H. THIS IS RECOMMENDED FOR UNIT SER VICEABILITY . B - 25 1/8” C - 28” NOTE: IF TRIM AROUND HEA TER IS NECESSAR Y , THE SURROUND KIT PVE-1 MU[...]
-
Page 17
22618-17-0308 Page 17 W ALL CLEARANCES Figure 14[...]
-
Page 18
22618-17-0308 Page 18 All Logs The positioning of the logs is critical to the safe and clean opera- tion of this heater . Sooting and other problems may result if the logs are not properly and firmly positioned in the appliance. 6. Prior to positioning of top left log and top right log, inspect front burner and rear burner for particles or dust ac[...]
-
Page 19
22618-17-0308 Page 19 VENT EXAMPLES FOR SINGLE FLUE Max V ent Run - 40 ft. Equivalent With Three (3) 90° Elbows Special Note: The vent terminal 90° elbow and first 90° elbow off back of the heater , when within 6” (15.2 cm), do not contrib - ute to the overall vent length measurement. For each 45° elbow installed in the horizontal run, the l[...]
-
Page 20
22618-17-0308 Page 20 VENT EXAMPLES FOR SINGLE FLUE (cont.) Figure 19 Single Flue - V ertical V ent Run H = 36’ V = 1’ (1) - 90° = 3’ T otal = 40’ SINGLE FLUE ADAPTOR MODEL #PVVK-SH Figure 21 Single Flue - V enting with Shroud Installed Shroud Kit Model# PVSH Figure 20 V enting for Existing Fir eplace Installation V = 40’ T otal = 40’[...]
-
Page 21
22618-17-0308 Page 21 Figure 23 Single Flue - V ertical V ent Run with 45 degree elbows VENT EXAMPLES FOR SINGLE FLUE (cont.) Figure 22 Minimum Exterior Grade Dimension - Single Flue, Horizontal V enting Below Floor W ARNING: Major U.S. building codes specify minimum chimney and/or vent height above the rooftop. These minimum heights are necessary [...]
-
Page 22
22618-17-0308 Page 22 A vailable from Empir e Comfort Systems, Inc. PVVK-CF A FLEX VENT KIT The flex vent kit is a flexible vent hose that is 42” in length. The flex vent kit will be used when installing a Mantis into an existing fireplace. The flex vent kit can be cut down, but can only be cut from one end. Cement PVC Joints Cut End Cement [...]
-
Page 23
22618-17-0308 Page 23 A vailable from Empir e Comfort Systems, Inc. INST ALL FOAM GASKET FLUE ADAPTOR PLASTIC GASKET THREADED CONNECTOR Attach flue adaptor to back of heater with four (4) screws. Note: No PVC cement is needed to install flue adaptor kit. Install plastic gasket and screw threaded connector to the flue adaptor . When these connect[...]
-
Page 24
22618-17-0308 Page 24 HORIZONT AL EXAMPLES FOR COLINEAR DIRECT VENT Figure 27 Enhanced top view of Figure 26 Figure 26 Max V ent Run - 40 ft. Equivalent With Three (3) 90° Elbows Special Note: The vent terminal 90° elbow and first 90° elbow off back of the heater , when within 6” (15.2 cm), do not con - tribute to the overall vent length meas[...]
-
Page 25
22618-17-0308 Page 25 VER TICAL EXAMPLES FOR COLINEAR DIRECT VENT Figure 28 Calculation example of vent run maximum 40’ Determining Minimum V ent Height Above the Roof W ARNING: Major U.S. building codes specify minimum chimney and/or vent height above the rooftop. These minimum heights are necessary in the interest of safety . Special Note: The [...]
-
Page 26
22618-17-0308 Page 26 VER TICAL EXAMPLES FOR COLINEAR DIRECT VENT SINGLE FLUE MODEL PVVK-SH CO-LINEAR DIRECT VENT ADAPTER MODEL PVCA 12 X HEIGHT FLASHING REQUIRED HEIGHT AIR INT AKE PTRAP, 2 90° ELBOWS (SUPPLIED BY INST ALLER) OR TERMINA TION CAP MODEL PVVTC. PTRAP TO FACE AW A Y FROM ROOF . EXHAUST TERMINA TION CAP MODEL PVVTC, PTRAP OR 2 90° EL[...]
-
Page 27
22618-17-0308 Page 27 PVCA HORIZONT AL COLINEAR DIRECT VENT ADAPTOR COLINEAR ADAPTER 1. Attach colinear adaptor to back of heater with two (2) screws. 2. When adapter is connected, continue with your vent run. Cementing PVC joint is recommended, but not required on colinear fresh air intake adaptor . Colinear adaptor Colinear adaptor to be used in [...]
-
Page 28
22618-17-0308 Page 28 PVVTC TERMINA TION CAP VENT KIT A vailable from Empir e Comfort Systems, Inc. T ermination Cap V ertical exhaust cap used with 1 1/2” PVC pipe installation. T ermination cap also used with colinear transition plate model PVCT . Refer to instruction manual for venting examples. PVC CEMENT[...]
-
Page 29
22618-17-0308 Page 29 PVCT COLINEAR TRANSITION VENT KIT A vailable from Empir e Comfort Systems, Inc. Flat Roof or Chimney Application 1. Attach plate to chimney chase or flat roof with four (4) screws. Use outdoor sealant to seal transition plate to the roof or chimney chase. 2. Check local codes to determine air intake height from roof. The mini[...]
-
Page 30
22618-17-0308 Page 30 DIRECT VENT INST ALLA TION INSTRUCTIONS FLUE CENTER EXTERIOR GRADE MANTEL GAS SUPPLY 12” (30.5cm) MIN. SURROUND DO NOT GLUE THIS POINT DIRECT VENT KIT MODEL #PVVK-24H OR PVVK-48H Figure 32 Horizontal V enting 45° ELBOW 47.5” (1.2m) Figure 33 Horizontal V enting Maximum 47.5” (1.2 m) with a 3”, 45° elbow 3”, 45° el[...]
-
Page 31
22618-17-0308 Page 31 DIRECT VENT INST ALLA TION INSTRUCTIONS (cont.) EXTERIOR GRADE FLUE CENTER 1 1/4” (3.2cm) MIN. 12” (30.5cm) MIN. FLOOR PROTECTION FLOOR PROTECTION NO HEARTH REQUIRED EXTERIOR GRADE FLUE CENTER 1 1/4” (3.2cm) MIN. 12” (30.5cm) MIN. Figure 36 Minimum Exterior Grade Dimension - Unit Without Pedestal Figure 37 Minimum Exte[...]
-
Page 32
22618-17-0308 Page 32 A vailable from Empir e Comfort Systems, Inc. Step 1. Install foam gasket on back side of co-axial direct vent adaptor . Step 2. Attach co-axial direct vent adaptor and gasket (4 screws) to the rear of fireplace. Step 3. Attach co-axial air-inlet duct to rear of fireplace (6 screws). Step 4. Install silicone around connectio[...]
-
Page 33
22618-17-0308 Page 33 45° ELBOW 47.5” (1.2m) Horizontal V enting Maximum 47.5” (1.2 m) with 45° elbow . 45° elbow can be purchased fr om a local hardware store. 47.5” (1.2m) Maximum Horizontal V enting - 47 1/2” (1.2 m) Minimum Horizontal V enting - 4” (10.2 cm) EXHAUST OPENING MUST BE POINTED DOWNW ARD. Direct V ent System Building Ex[...]
-
Page 34
22618-17-0308 Page 34 GAS CONNECTION INST ALLA TION INSTRUCTIONS GAS CONNECTION (Line Supply) A 3/8” Flair gas line connection is supplied in the heater GAS SUPPL Y LINE T O HEA TER a. Remove top panel from heater by lifting top panel. b. Remove front and rear panel. c. Remove rubber grommet from back panel of heater and insert gas supply line th[...]
-
Page 35
22618-17-0308 Page 35 OPERA TING INSTRUCTIONS CHECKLIST BEFORE OPERA TING THIS APPLIANCE, CAREFULL Y PROCEED THROUGH THE FOLLOWING CHECKLIST 1. Read and understand these instructions before installing or operating this appliance. 2. This appliance is should be installed and repaired by a fully qualified service person who must be familiar with the[...]
-
Page 36
22618-17-0308 Page 36 LIGHTING INSTRUCTIONS 1. Main Electrical power supply must always be switched on to the unit with the two burner switches in the off position (up) before lighting the heater . 2. T urn on main gas supply . 3. V erify that main electrical supply is switched on by checking the 1 15V AC power status display (Figures 40 and 41) in[...]
-
Page 37
22618-17-0308 Page 37 LIGHTING INSTRUCTIONS FOR YOUR SAFETY READ BEFORE LIGHTING W ARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTL Y , A FIRE OR EX- PLOSION MA Y RESUL T CAUSING PROPER TY DAMAGE, PERSONAL INJUR Y , OR LOSS OF LIFE. A. BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because som[...]
-
Page 38
22618-17-0308 Page 38 F AN OPERA TION The 3-speed main convection fan will automatically start approximately 3 to 5 minutes after the heater has warmed up. Note: The 3-speed main convection fan is automatically controlled and will operate on three preset speeds. Depending on your burner setting and the surrounding ambient temperature, the L.E.D lig[...]
-
Page 39
22618-17-0308 Page 39 GAS CONVERSION INSTRUCTIONS W arning: Conversion must be done by a qualified service technician. Main burner orifices, front burner bushing, and gas conversion label are pr ovided in conversion kit attached to manifold pipe. CONVERSION INSTRUCTIONS FROM (LP) PROP ANE GAS T O NA TURAL GAS 1. T urn OFF gas supply and electrica[...]
-
Page 40
22618-17-0308 Page 40 GAS CONVERSION INSTRUCTIONS W arning: Conversion must be done by a qualified service technician. Main burner orifice(s) and new gas conversion label are pr ovided in conversion kit attached to manifold pipe. CONVERSION INSTRUCTIONS FROM NA TURAL GAS T O (LP) PROP ANE GAS 1. T urn OFF gas supply and electrical power to firep[...]
-
Page 41
22618-17-0308 Page 41 AUT OMA TIC HUMIDIFIER OPERA TION Most gas heaters dry out the air in the room. The Mantis has in- geniously solved this problem with an Automatic Humidifier . Gas contains moisture which is normally expelled out the flue or chimney after combustion. But the Mantis is so efficient by taking 92% of the heat out of the burnt [...]
-
Page 42
22618-17-0308 Page 42 OPTIONAL CONTROLLERS See your Mantis dealer for correct controller type. MODELS FRBTP Battery Operated Remote w/ Programmable Thermostat FRBTC Battery Operated Remote w/ Thermostat TR W Battery Operated W ireless Remote W all Thermostat TMV2 Thermostat, 2 Stage INSTRUCTIONS MUST BE LEFT WITH THE OWNER FOR FUTURE REFERENCE AFTE[...]
-
Page 43
22618-17-0308 Page 43 OPTIONAL CONTROLLERS R: 24 V olt Hot W 1 : Heat Relay Stage 1 (Front burner) W 2 : Heat Relay Stage 2 (Rear burner) C: 24 V olt Common Figure 51 Replace front louver panel and plug unit into outlet. Turn both burner switches to ON position. Burner switches must remain in the ON position for thermostat to function. Set thermost[...]
-
Page 44
22618-17-0308 Page 44 WIRING (1) (2) BLACK BLACK (3) (4) RED YELL OW (5) (6) RED BL UE (7) (8) BROWN GREY (9) (10) RED RED (11) (12) BLACK BLACK (13) (14) RED RED (15) (16) FRONT H.S.I. FRONT H.S.I. (17) (18) REAR H.S.I. REAR H.S.I. (19) (20) BROWN WHITE (3-5-7) (1) BL UE BLACK (8) (2) BLACK (15) ORANGE (13) RED (11) BLACK (9) BROWN (7) PURPLE (5) [...]
-
Page 45
22618-17-0308 Page 45 GENERAL INFORMA TION Over T emperature Cut Out The Mantis Power -V ent High-Efficiency Fireplace is protected against overheating with a high temperature 80°C (176°F) cut off switch to protect the heat exchanger , plastic sump and flue fan. The high temperature cut off switch will automatically switch of f the gas supply t[...]
-
Page 46
22618-17-0308 Page 46 MAINTENANCE Figure 55 Front door removal drawing LOG SUPPORT PLA TE BURNER PLA TE REAR BURNER FRONT BURNER IGNITOR ASSEMBL Y FLAME SENSOR Figure 56 Main Burner Drawing Cleaning Main Burner Remove main burner and apply air pressure inside the throat and ports of the main burner . Removing HSI Flame Sensor , Blower and Orifice [...]
-
Page 47
22618-17-0308 Page 47 UNIT OPERA TING F AUL TS SER VICE AND INST ALLA TION OF THE APPLIANCE SHOULD BE CARRIED OUT BY AUTHORIZED PER- SONNEL ONL Y . THE MAJOR CAUSE OF OPERA TING PROBLEMS WITH GAS FIREPLACE HEA TERS IS IMPROPER GAS PRES - SURE, INCORRECT LOG PLACEMENT , IMPROPER IN- ST ALLA TION, INCORRECT FLUE INST ALLA TION, IN- CORRECT SWITCHING [...]
-
Page 48
22618-17-0308 Page 48 MAIN CONVECTION F AN The main convection fan in the heater should be checked, ser- viced and cleaned annually by a qualified service person to ensure that your appliance is operating efficiently . Note: If the main convection fan becomes clogged with lint and dust an over-temperature situation will occur through the heater e[...]
-
Page 49
22618-17-0308 Page 49 PEDEST AL INST ALLA TION INSTRUCTIONS Optional Pedestal Assembly Installation 1. Remove pedestal assembly from carton. Handle pedestal with care to avoid paint damage. 2. Place pedestal assembly into position where heater is to be located. 3. Lift and place main body of heater on top of pedestal assem- bly and align main body [...]
-
Page 50
22618-17-0308 Page 50 PLEASE NOTE: When ordering parts, it is very important that part number and description of part coincide. 1 22868 REAR P ANEL ASSEMBL Y 2 21654 BRACKET , PIPE ASSEMBL Y 3 22670 REAR HEA T SHIELD ASSEMBL Y 4 21664 T OP COVER ASSEMBL Y (INCLUDES #5) 5 R8854 BALL STUD 6 22693 T OP HEA T SHIELD ASSEMBL Y 7 22859 FIREBOX ASSEMBL Y [...]
-
Page 51
22618-17-0308 Page 51 50 22628 GAS LINE - FRONT 51 M174 GASKET 52 1 1269 GAS LINE BRACKET 53 R8886 COMPRESSION FITTING 54 R8812 V AL VE, NA T 54 R8869 V AL VE, LPG 55 R8898 PIPE NIPPLE 56 R8825 SOLENOID 57 R3312 CONNECT OR, MALE 3/8 X 3/8 58 R8827 FLEX LINE (2 USED) 59 R8846 SHUT -OFF V AL VE 60 22866 FIREBOX BASE ASSEMBL Y 61 24045 CONTROL BOX ASS[...]
-
Page 52
22618-17-0308 Page 52 P AR TS VIEW 1 4 5 6 9 7 30 28 33 5 21 15 27 24 28 19 1 1 12 9 10 9 34 29 31 16 20 14 29 26 25 22 17 8 3 2 13 36 18 35 23 32[...]
-
Page 53
22618-17-0308 Page 53 P AR TS VIEW 69 67 72 84 61 50 47 48 53 54 53 51 60 56 55 48 47 80 52 65 39 40 41 42 38 45 46 89 85 86 87 88 81 78 77 73 66 83 76 90 44 43 49 37 82 70 71 64 79 63 62 57 59 58 74 58 75 68 91 92[...]
-
Page 54
22618-17-0308 Page 54 W ARRANTY TERMS Purchase Date: Dealer Name/Phone: Limited T en-Y ear Heat Exchanger W arranty Empire promises to the owner that if the heat exchanger (see parts list) fails because of defective workmanship or material within ten years from the date of purchase, Empire will repair , or at Empire’ s option, replace the defecti[...]
-
Page 55
22618-17-0308 Page 55 SER VICE NOTES Parts can be ordered only through your service person or dealer . For best results, the service person or dealer should order parts through the distributor . Parts can be shipped directly to the service person/dealer . All parts listed in the Parts List have a Part Number . When ordering parts, first obtain the[...]
-
Page 56
22618-17-0308 Page 56 SER VICE NOTES EMPIRE EMPIRE Comfo rt Systems Empire Comfort Systems Inc. 918 Freeburg A ve. Belleville, IL 62220 If you have a general question about our products, please e-mail us at info@empirecomfort.com. If you have a service or repair question, please contact your dealer . www .empirecomfort.com[...]