Hearth and Home Technologies HST-48D manuel d'utilisation
- Voir en ligne ou télécharger le manuel d’utilisation
- 48 pages
- 3.73 mb
Aller à la page of
Les manuels d’utilisation similaires
-
Indoor Fireplace
Hearth and Home Technologies WTBC42DB
4 pages 0.68 mb -
Indoor Fireplace
Hearth and Home Technologies 8000TV-OAK-IPI
46 pages 2.43 mb -
Indoor Fireplace
Hearth and Home Technologies GDST3831I
62 pages 2.85 mb -
Indoor Fireplace
Hearth and Home Technologies PIER-TRC
40 pages 1.71 mb -
Indoor Fireplace
Hearth and Home Technologies Cinch Pipe & Termination Cap System
12 pages 1.86 mb -
Indoor Fireplace
Hearth and Home Technologies EXCLAIM-50
52 pages 5.27 mb -
Indoor Fireplace
Hearth and Home Technologies PIER-40
52 pages 3.03 mb -
Indoor Fireplace
Hearth and Home Technologies SILH30E-B
24 pages 1.06 mb
Un bon manuel d’utilisation
Les règles imposent au revendeur l'obligation de fournir à l'acheteur, avec des marchandises, le manuel d’utilisation Hearth and Home Technologies HST-48D. Le manque du manuel d’utilisation ou les informations incorrectes fournies au consommateur sont à la base d'une plainte pour non-conformité du dispositif avec le contrat. Conformément à la loi, l’inclusion du manuel d’utilisation sous une forme autre que le papier est autorisée, ce qui est souvent utilisé récemment, en incluant la forme graphique ou électronique du manuel Hearth and Home Technologies HST-48D ou les vidéos d'instruction pour les utilisateurs. La condition est son caractère lisible et compréhensible.
Qu'est ce que le manuel d’utilisation?
Le mot vient du latin "Instructio", à savoir organiser. Ainsi, le manuel d’utilisation Hearth and Home Technologies HST-48D décrit les étapes de la procédure. Le but du manuel d’utilisation est d’instruire, de faciliter le démarrage, l'utilisation de l'équipement ou l'exécution des actions spécifiques. Le manuel d’utilisation est une collection d'informations sur l'objet/service, une indice.
Malheureusement, peu d'utilisateurs prennent le temps de lire le manuel d’utilisation, et un bon manuel permet non seulement d’apprendre à connaître un certain nombre de fonctionnalités supplémentaires du dispositif acheté, mais aussi éviter la majorité des défaillances.
Donc, ce qui devrait contenir le manuel parfait?
Tout d'abord, le manuel d’utilisation Hearth and Home Technologies HST-48D devrait contenir:
- informations sur les caractéristiques techniques du dispositif Hearth and Home Technologies HST-48D
- nom du fabricant et année de fabrication Hearth and Home Technologies HST-48D
- instructions d'utilisation, de réglage et d’entretien de l'équipement Hearth and Home Technologies HST-48D
- signes de sécurité et attestations confirmant la conformité avec les normes pertinentes
Pourquoi nous ne lisons pas les manuels d’utilisation?
Habituellement, cela est dû au manque de temps et de certitude quant à la fonctionnalité spécifique de l'équipement acheté. Malheureusement, la connexion et le démarrage Hearth and Home Technologies HST-48D ne suffisent pas. Le manuel d’utilisation contient un certain nombre de lignes directrices concernant les fonctionnalités spécifiques, la sécurité, les méthodes d'entretien (même les moyens qui doivent être utilisés), les défauts possibles Hearth and Home Technologies HST-48D et les moyens de résoudre des problèmes communs lors de l'utilisation. Enfin, le manuel contient les coordonnées du service Hearth and Home Technologies en l'absence de l'efficacité des solutions proposées. Actuellement, les manuels d’utilisation sous la forme d'animations intéressantes et de vidéos pédagogiques qui sont meilleurs que la brochure, sont très populaires. Ce type de manuel permet à l'utilisateur de voir toute la vidéo d'instruction sans sauter les spécifications et les descriptions techniques compliquées Hearth and Home Technologies HST-48D, comme c’est le cas pour la version papier.
Pourquoi lire le manuel d’utilisation?
Tout d'abord, il contient la réponse sur la structure, les possibilités du dispositif Hearth and Home Technologies HST-48D, l'utilisation de divers accessoires et une gamme d'informations pour profiter pleinement de toutes les fonctionnalités et commodités.
Après un achat réussi de l’équipement/dispositif, prenez un moment pour vous familiariser avec toutes les parties du manuel d'utilisation Hearth and Home Technologies HST-48D. À l'heure actuelle, ils sont soigneusement préparés et traduits pour qu'ils soient non seulement compréhensibles pour les utilisateurs, mais pour qu’ils remplissent leur fonction de base de l'information et d’aide.
Table des matières du manuel d’utilisation
-
Page 1
1 Owner ’ s Manual Installation and Operation Models: HST -48D Wood Burning Fireplace DO NOT DISCARD THIS MANUAL NOTICE • Important operating and maintenance instructions included. • Leave this manual with party responsible for use and operation. • Read, understand and follow these instructions for safe installation and operation. DO NOT DI[...]
-
Page 2
2 Read this manual before installing or operating this fi replace. Please retain this owner ’ s manual for future reference. Homeowner Reference Information Model Name: Date purchased/installed: Serial Number: Location on fi replace: Dealership purchased from: Dealer phone: Notes: We recommend that you record the following pertinent information[...]
-
Page 3
3 Safety Alert Key: • DANGER! Indicates a hazardous situation which, if not avoided will result in death or serious injury . • W ARNING! Indicates a hazardous situation which, if not avoided could result in death or serious injury . • CAUTION! Indicates a hazardous situation which, if not avoided, could result in minor or moderate injury . ?[...]
-
Page 4
4 W arranty Hearth & Home T echnologies LIMITED W ARRANTY Hearth & Home T echnologies (“HHT”) and its respective brands extends the following warranty for HHT gas, wood, pellet and electric appliances purchased from an authorized HHT dealer and installed in the United States of America or Canada. W arranty starts with date of purchase b[...]
-
Page 5
5 This limited warranty does not extend to or include surface ? nish on the appliance or terminations, door gasketing, glass gasketing, glass discoloration, ? rebrick, pellet logs, kaowool or other ceramic insulating materials. Rust and/or corrosion on any of the metal surfaces, cast iron components, baf? es, ? repots, doors, or ? rebox area are no[...]
-
Page 6
6 1 1 Listing and Code Appro v als NOTICE: This fireplace is tested and approved as a decorative fi replace. It should not be factored as a primary heat source in residential heating calculations. W ARNING! Risk of Fire! Hearth & Home T echnologies disclaims any responsibility for , and the warranty and agency listing will be voided by the fol[...]
-
Page 7
7 2 2 Operat ing Instr uct ions W ARNING! DO NOT operate fi replace before reading and understanding operating instructions. Failure to operate fi replace according to operating instructions could cause fi re or injury . User Guide W ARNING Hot glass will cause burns. • DO NOT touch glass until it is cooled • NEVER allow children to touch gl[...]
-
Page 8
8 • The fi rst three or four fi res should be of moderate size to allow the oils and binders to be burned from the fi replace and the refractory and paint to cure. Y ou may notice an industrial odor the fi rst few fi res. This is considered normal. • Use well-seasoned wood. • Open the fl ue damper to a fully open position. • Place cru[...]
-
Page 9
9 P ARTL Y OPEN INCORRECT FULL Y OPEN CORRECT P ARTL Y CLOSED INCORRECT FULL Y CLOSED CORRECT Figure 2.2 Operating Positions of Bi-fold Doors W ARNING! Risk of Fire and Smoke! Fireplaces equipped with doors should be operated only with doors fully open or doors fully closed. If doors are left partly open, gas and fl ame may be drawn out of the fi[...]
-
Page 10
10 M. Wood Fuel Hardwood vs Softwood Y our fi replace performance depends on the quality of the fi rewood you use. • Seasoned wood contains about 8,000 BTUs per pound . • Hard woods are more dense than soft woods. • Hard woods contain 60% more BTUs than soft woods. • Hard woods require more time to season, burn slower and are harder to ig[...]
-
Page 11
11 3 3 Maintainance and Ser vice Figure 3.1 Chimney & T ermination Cap Cleaning A. Disposal of Ashes Frequency: When they reach bottom of grate By: Homeowner W ARNING! Risk of Fire! Ashes could contain hot em- bers. • Place ashes in a metal container with a tight- fi tting lid. • The closed container should be placed on a noncombustible ?[...]
-
Page 12
12 C. Check Firebox Refractory Frequency: After each ash removal By: Homeowner D. Inspect Grate Frequency: After each ash removal By: Homeowner Inspect grate for: • W arping or sagging 1-1/2 in. (38 mm) or more • Broken welds • Burn-through of grate bars For safe operation, replace only with an approved grate from Hearth & Homes T echnolo[...]
-
Page 13
13 4 4 T roubleshooting Guide Start Fire Problems Possible Cause Solution Can’t get fi re started Excessive smoke or spillage Burns too slowly Smolders, sizzles Not enough kindling/paper or no kindling/paper Use dry kindling, more paper . Arrange kindling & wood for air movement. Damper closed/not fully open Open damper . Not enough air for [...]
-
Page 14
14 5 5 Get ting Star ted A. T ypical Fireplace System Installer Guide Heat & Glo • HST -48D US-CAN • 4012-040 • Rev F • 1 1/08 ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) ) Non-combustible roof flashing maintains minimum clearance around chimney Additional later[...]
-
Page 15
15 Negative pressure results from the imbalance of air avail- able for the fi replace to operate properly . It can be stron- gest in lower levels of the house. Causes include: • Exhaust fans (kitchen, bath, etc.) • Range hoods • Combustion air requirements for furnaces, water heaters and other combustion appliances • Clothes dryers • Loc[...]
-
Page 16
16 Marginal Location: • Below peak Location NOT recommended: • Not the highest point of the roof • Wind loading possible Multi-level Roofs Windward Leeward Recommended Location: • Above peak Recommended: • Insulated exterior chase in cooler climates Recommended Location: • Above peak • Inside heated space Location NOT recommended: •[...]
-
Page 17
17 Before beginning the installation be sure the following tools and building supplies are available: Reciprocating saw Framing material Pliers Non-combustible sealant Hammer Gloves Phillips screwdriver Framing square Flat blade screwdriver Electric drill and bits Plumb line Safety glasses Level T ape measure 1/2-3/4 in. length, #6 or #8 self-drill[...]
-
Page 18
18 6 6 F raming & Clearances 66 in. (1676 mm) 42 in. (1067 mm) 20 in. (508 mm) (hearth extension) 64 in. (1626 mm) 12 in. (305 mm) min. to perpendicular wall. Figure 6.1 Fireplace Locations (Framing dimensions shown) A. Select Fireplace Location Note: 1/2 in. ( 1 3 mm ) dist ance from firepla ce to com bu sti bl e m at eri al s. Note: In additi[...]
-
Page 19
19 B. Clearances W ARNING! Risk of Fire! Y ou must comply with all minimum air space clearances to combustibles as speci fi ed in Fig- ure 6.2. DO NOT pack required air spaces with insulation or other materials. Heat & Glo • HST -48D US-CAN • 4012-040 • Rev F • 1 1/08 (roof) (insulation) 0 in. to level of standoffs Attic Insulation Shi[...]
-
Page 20
20 47 in. [1 194 mm] width of fireplace 42 in. [1067 mm] fireplace opening 9 3/4 in. [248 mm] 12 in. [305 mm] 12 in. [305 mm] 1 1 3/8 in. [289 mm] FLUSH FRONT 4 in. [102 mm] BRICK FRONT 50° angle 39° angle Gridlines at 1 in. scale D. Frame the Fireplace Figure 6.4 shows typical framing using combustible materials (2x4 lumber shown). • Observe a[...]
-
Page 21
21 7 7 Installation of Fireplace CAUTION! Risk of Cuts/Abrasions. Wear protective gloves and safety glasses during installation. Sheet metal edges are sharp. A. Things to Consider • Location of chimney air kit inlet (see Figure 5.1 and 7.4) • Location(s) of outside air kit • Electrical connections and/or wall switch • Gas line piping B. Pos[...]
-
Page 22
22 Outlet placed higher than 3 ft below the termination cap Attic space Garage or combustible liquids storage Outlet blocked by snow , leaves, etc. Clear area outside house or in ventilated crawl space YES NO NO NO NO Use only duct materials specified by manufacturer (preferably with short run or mainly straight duct, except small dip for cold air [...]
-
Page 23
23 Outside Air Hood Outside Air Plate Assembly 2 Wire T ies Flexible Duct (not supplied) Figure 7.5 Outside Air Installation E. Install Outside Air Kit • Keep duct runs short and straight to minimize restriction. A small dip is acceptable for a cold air trap. • The outside air kit must be installed using the outside air cover (see Dimensions, S[...]
-
Page 24
24 Chimney must extend beyond combustible roof structure Maintain minimum height of chimney above roof Additional support for tall chimneys Install roof flashing according to minimum requirements Maintain minimum clearances to combustibles as specified Offsets/returns may not exceed 30° from vertical Lock chimney sections together firmly to resist[...]
-
Page 25
25 A. Chimney Requirements Measure vertical distances from the base of the fi replace as shown in Figure 8.2. d & g Ceiling Firestop h i 58-7/8 in. (1495 mm) Effective Height a,b,c,f 1 1-10 in. (279-254 mm) adapter required in Canada. Figure 8.2 Chimney Requirements (refer to list in Sect. 5.A.) T able 8.1 ft meters a. Minimum overall straight[...]
-
Page 26
26 T able 8.2 B. Using Offsets/Returns • Use an of fset/return to bypass overhead obstructions. • An of fset and return can be used as a single entity or separated by chimney section(s). W ARNING! Risk of Fire! DO NOT use offset/returns greater than 30°. Chimney draft will be restricted and could cause overheating and fi re. • Measure the s[...]
-
Page 27
27 Figure 8.4 Assembling Chimney Sections • Support the pipe during construction and check to be sure inadvertent loading has not dislodged the chimney section from the fi replace or at any chimney joint. • Attach a straight chimney section or an offset to the top of the fi replace. • Place inner fl ue to the inside of the chimney section [...]
-
Page 28
28 ROOM ABOVE (non-insulated ceiling) A TTIC ABOVE (insulated ceiling) B A Ceilng firestop from bottom Ceiling firestop from top Note: Use same dimensional lumber for framing ceiling firestop and joists. Figure 8.5 Installing the Ceiling Firestop • Install a ceiling fi restop whenever chimney penetrates ceiling/ fl oor . • Mark and cut an ope[...]
-
Page 29
29 3 in. (76 mm) overlap Insert three screws Bend inward 90° Bend remaining tabs to rest against pipe to prevent insulation from falling in. Figure 8.6 Prepare Attic Insulation Shield Installation of a ceiling fi restop is required • Refer to Figures 8.6 - 8.8. • Roll the shield (around the chimney if already installed) until you have a 3 in.[...]
-
Page 30
30 Figure 8.9 Ceiling/Attic Construction H. Complete Installation W ARNING! Risk of Fire! Y ou MUST maintain 2 in. (51 mm) air space to insulation and other combustible materials around the chimney system. Failure to do so could cause overheating and fi re. • Keep chimney sections from separating or twisting. • Y ou may secure straight chimney[...]
-
Page 31
31 Slanted Roofs Flat Roofs Chimney must extend 3 ft (.9 m) above the roof Chimney must extend 2 ft (.6 m) above any portion of the roof or adjacent structures within 10 ft (3 m) of the chimney Chimney must extend 3 ft (.9 m) above the roof Chimney must extend 2 ft (.6 m) above any portion of the roof or adjacent structures within 10 ft (3 m) of th[...]
-
Page 32
32 9 9 Chase Installations Ceiling Firestop Metal Chase T op Round T ermination Cap False Ceiling Insulation in the outside walls of the chase Attic Insulation Shield Chimney Ceiling Firestop T abs False Ceiling False Ceiling Insulation Insulation Figure 9.1 Chase Assembly 1 2 1. Chimney of fset through exterior wall and enclosed in chase. 2. Chase[...]
-
Page 33
33 Slope Downward (1/4 in. per foot minimum) T urn-down Drip Edge Chase 2 in. (51 mm) Collar on Chase T op .018 (26 ga) min. Galvanized Chase T op Figure 9.3 Chase T op Construction B. Install Fireplace & Chimney Install as per Sections 7 and 8. Heat & Glo • HST -48D US-CAN • 4012-040 • Rev F • 1 1/08 C. Install Chase T op • Y ou [...]
-
Page 34
34 D. Install T ermination Cap Install the chimney sections up through the chase enclo- sure. • Refer to termination cap instructions. W ARNING! Risk of Fire! The minimum overlap of cap to pipe (as shown in the following illustrations) MUST be met or chimney may separate from cap. Separation allows sparks, heat and embers to escape. NOTICE: Paint[...]
-
Page 35
35 Heat & Glo • HST -48D US-CAN • 4012-040 • Rev F • 1 1/08 Chimney Pipe Chase T op T ermination Cap Chase Collar 2 in. (51 mm) Minimum Height T ermination cap pipe and chimney section must overlap 1-1/2 in. (38 mm) Place waterproof sealer under each flange of the termina- tion cap and on top of each screw to help prevent leaks. The las[...]
-
Page 36
36 3 in. (76 mm) tall legs Ø 17 1/2 in. (444.5 mm) Round Hole to fit over cap Length x Width to fit inside shroud Figure 10.1 Radiation Shield 1 0 10 Shrouds • Chase top shrouds may be fi eld constructed where permitted by regional building codes. W ARNING! Risk of Fire! Shrouds must be constructed as speci fi ed. Improper construction may ove[...]
-
Page 37
37 3 in. (76 mm) Min. Opening Height Min. Base Dim Min. Height above radiation shield Min. Base Dim 3 in. (76 mm) Min. Radiation Shield Height from top of Chase Min. Opening Width Figure 10.3 Mailbox Style Shroud Dimensions Minimum Opening Height Minimum Base Dimension Min. Opening Width Min . Base Dimension Minimum Height above Radiation Shield Ch[...]
-
Page 38
38 1 1 11 Fi n i s hi n g A. Non-Combustible Materials • Materials which will not ignite and burn, composed of any combination of the following: - Steel - Iron - Brick - T ile - Concrete - Slate - Glass - Plasters • Materials reported as passing ASTM E 136, Standard T est Method for Behavior of Metals, in a V ertical T ube Furnace at 750° C B.[...]
-
Page 39
39 D. Finishing Material Refer to Sections 1 1.A. and Sections 1 1.B. for combus- tible/noncombustible materials. Refer to Figure 1 1.2 for noncombustible zone. W ARNING! Risk of Fire! Y ou must maintain clearances. • Use only non-combustible framing material below standoffs. • Sheetrock, wood or other combustibles must NOT be used as sheathing[...]
-
Page 40
40 E. Combustible Mantel • See Figure 1 1.4. • A combustible mantel may be positioned no lower than 12 in. (305 mm) above the top of the fi replace opening. • A combustible mantel may have a maximum depth of 12 in. (305 mm). • Combustible trim and materials cannot be placed within 6 in. (152 mm) of the fi replace opening (top or sides). ?[...]
-
Page 41
41 Firebox Repack Insulation Knockout Combustible Materials Maintain air clearance to combustibles. Gas Line Combustible materials may be located at zero clearance to gas line beyond 4 in. (102 mm) from fireplace side. Gas Line 1 1/2 in. (38 mm) air space around pipe Refractory Seal with fireplace mortar or non-combust- ible sealant 4 in. (102 mm) [...]
-
Page 42
42 1 3 13 Refer ence Materials A. Fireplace Dimensions 58-7/8 in. (1496 mm) (effective height) 42 in. (1067 mm) 23 in. (585 mm) 7-1/2 in. (192 mm) 13 in. [330 mm] dia. 39-1/8 in. (995 mm) 47 in. (1 194 mm) 28 in. (71 1 mm) 23-1/2 in. (597 mm) 14 in. (356 mm) Gas Knockout 8-3/8 in. (213 mm) 14 in. (356 mm) 39-1/8 in. (994 mm) 39-1/8 in. (994 mm) 38-[...]
-
Page 43
43 B. Optional Components 20 in. (508 mm) 66 in. (1676 mm) 1/2 in. (13 mm) HX4 Hearth Extension Bi-fold Glass Doors Heat & Glo • HST -48D US-CAN • 4012-040 • Rev F • 1 1/08 See your Heat & Glo dealer for a complete listing of optional components.[...]
-
Page 44
44 B. Chimney Components The following pictures show only those chimney components which may be safely used with this fi replace. ID4 Insulated Duct UD4 Uninsulated Duct 42 in. (1067 mm) 4 in. (102 mm) i 42 in. (1067 ) 4 in. (102 mm) i Heat & Glo • HST -48D US-CAN • 4012-040 • Rev F • 1 1/08 Catalog # Description US CAN CAK5A CAK5A Chi[...]
-
Page 45
45 TR-TVK TR T op V ent Kit Heat & Glo • HST -48D US-CAN • 4012-040 • Rev F • 1 1/08 AS10 Straight Attic Insulation Shield Assembled Diameter: 17 in./432 mm Height: 24 in./610 mm CB576 Chimney Joint Band 13 in. (330 mm) JB577 Chimney Joint Band 2 in. (51 mm) 13 in. (330 mm) A B 17 in. (432 mm) Catalog # A B FS538 0-deg. 17 in. 432 mm FS[...]
-
Page 46
46 A B C D LDS33/LDS46 Decorative Shroud Catalog # ABCD in. mm in. mm in. mm in. mm LDS33 36 914 36 914 8-1/2 216 1 1 279 LDS46 48 1219 72 1829 8-1/2 216 1 1 279 E D A C B Catalog # A B C D E LDS-BV in. 26 12-1/2 15-1/2 22 23 mm 660 318 394 533 584 LDS-BV Decorative Shroud Heat & Glo • HST -48D US-CAN • 4012-040 • Rev F • 1 1/08 CT56 Ch[...]
-
Page 47
47 C. Service Parts 5/08 Service Parts Service Parts Diagram 42 in. See-through Woodburning Fireplace Part number list on following page. HST -48D 2 1 8 6 91 0 1 1 7 5 12 4 3 Duct sold separately 13 14 15 Side of Fireplace Beginning Manufacturing Date: Aug 2001 Ending Manufacturing Date: Active 5/08 Service Parts Service Parts List 42 in. See-throu[...]
-
Page 48
48 – NOTES – D. Contact Information DO NOT DISCARD THIS MANUAL CAUTION • Important operating and maintenance instructions included. • Leave this manual with party responsible for use and operation. • Read, understand and follow these instructions for safe installation and operation. DO NOT DISCARD This product may be covered by one or mor[...]