Hearth and Home Technologies QVI-25FB-S manuel d'utilisation
- Voir en ligne ou télécharger le manuel d’utilisation
- 40 pages
- 2.4 mb
Aller à la page of
Les manuels d’utilisation similaires
-
Indoor Fireplace
Hearth and Home Technologies SL-950TV-D
53 pages 3.49 mb -
Indoor Fireplace
Hearth and Home Technologies GBFL4136I
50 pages 2.44 mb -
Indoor Fireplace
Hearth and Home Technologies A42CH
48 pages 4.27 mb -
Indoor Fireplace
Hearth and Home Technologies SL-550TV-IPI-E
48 pages 3.17 mb -
Indoor Fireplace
Hearth and Home Technologies GDFL4136
88 pages 5.97 mb -
Indoor Fireplace
Hearth and Home Technologies GO30SP-LP
27 pages 9.54 mb -
Indoor Fireplace
Hearth and Home Technologies E39
32 pages 1.27 mb -
Indoor Fireplace
Hearth and Home Technologies Pier-HVB-IPI
40 pages 2.46 mb
Un bon manuel d’utilisation
Les règles imposent au revendeur l'obligation de fournir à l'acheteur, avec des marchandises, le manuel d’utilisation Hearth and Home Technologies QVI-25FB-S. Le manque du manuel d’utilisation ou les informations incorrectes fournies au consommateur sont à la base d'une plainte pour non-conformité du dispositif avec le contrat. Conformément à la loi, l’inclusion du manuel d’utilisation sous une forme autre que le papier est autorisée, ce qui est souvent utilisé récemment, en incluant la forme graphique ou électronique du manuel Hearth and Home Technologies QVI-25FB-S ou les vidéos d'instruction pour les utilisateurs. La condition est son caractère lisible et compréhensible.
Qu'est ce que le manuel d’utilisation?
Le mot vient du latin "Instructio", à savoir organiser. Ainsi, le manuel d’utilisation Hearth and Home Technologies QVI-25FB-S décrit les étapes de la procédure. Le but du manuel d’utilisation est d’instruire, de faciliter le démarrage, l'utilisation de l'équipement ou l'exécution des actions spécifiques. Le manuel d’utilisation est une collection d'informations sur l'objet/service, une indice.
Malheureusement, peu d'utilisateurs prennent le temps de lire le manuel d’utilisation, et un bon manuel permet non seulement d’apprendre à connaître un certain nombre de fonctionnalités supplémentaires du dispositif acheté, mais aussi éviter la majorité des défaillances.
Donc, ce qui devrait contenir le manuel parfait?
Tout d'abord, le manuel d’utilisation Hearth and Home Technologies QVI-25FB-S devrait contenir:
- informations sur les caractéristiques techniques du dispositif Hearth and Home Technologies QVI-25FB-S
- nom du fabricant et année de fabrication Hearth and Home Technologies QVI-25FB-S
- instructions d'utilisation, de réglage et d’entretien de l'équipement Hearth and Home Technologies QVI-25FB-S
- signes de sécurité et attestations confirmant la conformité avec les normes pertinentes
Pourquoi nous ne lisons pas les manuels d’utilisation?
Habituellement, cela est dû au manque de temps et de certitude quant à la fonctionnalité spécifique de l'équipement acheté. Malheureusement, la connexion et le démarrage Hearth and Home Technologies QVI-25FB-S ne suffisent pas. Le manuel d’utilisation contient un certain nombre de lignes directrices concernant les fonctionnalités spécifiques, la sécurité, les méthodes d'entretien (même les moyens qui doivent être utilisés), les défauts possibles Hearth and Home Technologies QVI-25FB-S et les moyens de résoudre des problèmes communs lors de l'utilisation. Enfin, le manuel contient les coordonnées du service Hearth and Home Technologies en l'absence de l'efficacité des solutions proposées. Actuellement, les manuels d’utilisation sous la forme d'animations intéressantes et de vidéos pédagogiques qui sont meilleurs que la brochure, sont très populaires. Ce type de manuel permet à l'utilisateur de voir toute la vidéo d'instruction sans sauter les spécifications et les descriptions techniques compliquées Hearth and Home Technologies QVI-25FB-S, comme c’est le cas pour la version papier.
Pourquoi lire le manuel d’utilisation?
Tout d'abord, il contient la réponse sur la structure, les possibilités du dispositif Hearth and Home Technologies QVI-25FB-S, l'utilisation de divers accessoires et une gamme d'informations pour profiter pleinement de toutes les fonctionnalités et commodités.
Après un achat réussi de l’équipement/dispositif, prenez un moment pour vous familiariser avec toutes les parties du manuel d'utilisation Hearth and Home Technologies QVI-25FB-S. À l'heure actuelle, ils sont soigneusement préparés et traduits pour qu'ils soient non seulement compréhensibles pour les utilisateurs, mais pour qu’ils remplissent leur fonction de base de l'information et d’aide.
Table des matières du manuel d’utilisation
-
Page 1
Quadra-Fire • QVI-25FB-S • 2031-910 Rev . E • 9/08 1 Model: QVI-25FB-S • Do not store or use gasoline or other fl am- mable vapors and liquids in the vicinity of this or any other appliance. • What to do if you smell gas - Do not try to light any appliance - Do not touch any electrical switch. Do not use any phone in your building. - Imm[...]
-
Page 2
Quadra-Fire • QVI-25FB-S • 2031-910 Rev . E • 9/08 2 Congratulations Listing Label Information/Location Model Name: ___________________________________________ Date purchased/installed: __________________ Serial Number: __________________________________________ Location on appliance: ____________________ Dealership purchased from: __________[...]
-
Page 3
Quadra-Fire • QVI-25FB-S • 2031-910 Rev . E • 9/08 3 T able of Contents 1 Listing and Code Approvals A. Appliance Certi fi cation . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 B. BTU Speci fi cations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 C. High Altitude Installations . . . . . . . . . . . . . . . . . .[...]
-
Page 4
Quadra-Fire • QVI-25FB-S • 2031-910 Rev . E • 9/08 4 Note : T o assure top performance, safety and ef fi ciency , inserts must be installed with an approved fl ue liner as per CAN/CGA B-149 or National Fuel Gas Code ANSI Z223 and these instructions. Not e: This installation must c onform wi th local c odes. In the absenc e of local c odes y[...]
-
Page 5
Quadra-Fire • QVI-25FB-S • 2031-910 Rev . E • 9/08 5 Quadra-Fire gas inserts are designed for recessed installa- tions into solid fuel masonry or factory built non-combustible fi replaces that have been installed in accordance with the National, Provincial, State and local building codes. Prior to installing the gas insert: • Have the chim[...]
-
Page 6
Quadra-Fire • QVI-25FB-S • 2031-910 Rev . E • 9/08 6 3 3 F ireplace Size Requirements Figure 3.1 Fireplace Opening NOTE: For actual appliance dimensions refer to Section 15. 20-3/8 in. 14-7/16 in. 29-3/4 in. 15 in. 5-9/16 in. 1-1/16 in. 18-15/16 in. GAS INLET (GAS BALL V AL VE NOT SHOWN) EXISTING MINIMUM WOODBURNING FIREPLACE SIZE Location In[...]
-
Page 7
Quadra-Fire • QVI-25FB-S • 2031-910 Rev . E • 9/08 7 B. Clearances Figure 3.2 Clearances to Mantels or other Combustibles above Appliance Fire Risk. • Locate and install appliance to all clearance speci fi cations in manual. Fire Risk. Odor Risk. • Clearance to combustible material under the insert is 1/4 inch (0.6 cm). • Use leveling [...]
-
Page 8
Quadra-Fire • QVI-25FB-S • 2031-910 Rev . E • 9/08 8 Fire Risk. Asphyxiation Risk. • T erminations MUST meet minimum clearances. • Exhaust gases are hot. • Nearby vents may draw fumes into house. A. V ent T ermination Minimum Clearances Figure 4.1 speci fi es minimum vent heights for various pitched roofs. Roof Pitch H (Min.) Ft. Flat [...]
-
Page 9
Quadra-Fire • QVI-25FB-S • 2031-910 Rev . E • 9/08 9 CAUTION ALL vent speci fi cations MUST be followed. • This product is tested and listed to these speci fi cations. • Appliance performance will suffer if speci fi cations are not followed. Figure 5.1 C. Measuring Standards V ertical measurements listed in the vent diagram (Figure 5.1[...]
-
Page 10
Quadra-Fire • QVI-25FB-S • 2031-910 Rev . E • 9/08 10 6 6 Installation Preparation Fire Risk. A hearth or hearth extension (if present) must comply with either of the following: • The solid fuel burning fi replace manufacturer’s speci fi cation. • Local building codes required by authority having jurisdiction. • NFPA 211 Prepare the[...]
-
Page 11
Quadra-Fire • QVI-25FB-S • 2031-910 Rev . E • 9/08 1 1 A. V enting Components 7 7 Installing V ent P ipe and Appliance The vertical vent termination system installed on this model includes: • One 3-foot section stainless steel fl exible pipe (included with insert). • One length of 3-inch fl exible vent pipe for combustion air (included [...]
-
Page 12
Quadra-Fire • QVI-25FB-S • 2031-910 Rev . E • 9/08 12 Figure 7.1 ST AINLESS STEEL ADAPTER FOR EXHAUST (MUST BE INST ALLED) INLET AIR VENT PIPE 3 INCH COLLAR OPTIONAL LINK-ZC-ADPB (For Flashing Class-A Pipe) TERMINA TION CAP (SQUARE FLASHING REMOVED) EXHAUST VENT PIPE SUPPLIED WITH TERMINA TION KIT INLET AIR VENT COLLAR (LINK-DV30 SHOWN) AL TE[...]
-
Page 13
Quadra-Fire • QVI-25FB-S • 2031-910 Rev . E • 9/08 13 Figure 7.2 CUT AND BEND FLASHING AS NEEDED TO FIT CHIMNEY SEALANT ADHESIVE • T rim chimney top plate to minimize excess overhang or bend over fl ue tile (see Figure 7.2). • Place 3/8 inch bead of 300º F silicone on fl ue tile top. C. Placing, Securing and Leveling the Appliance • [...]
-
Page 14
Quadra-Fire • QVI-25FB-S • 2031-910 Rev . E • 9/08 14 D. Installing Adaptor and T ermination Cap For installation of termination cap see minimum vent heights for various pitched roofs (see Figure 7.2) . T o install adaptor see Figure 7.3. Roof Pitch H (Min.) Ft. Flat to 6/12.................... 1.0* Over 6/12 to 7/12 ........1.25* Over 7/12 t[...]
-
Page 15
Quadra-Fire • QVI-25FB-S • 2031-910 Rev . E • 9/08 15 • Ensure that gas line does not come in contact with outer wrap of appliance. Follow local codes. • Incoming gas line should be piped into the valve compartment and connected to the 1/2 inch connection on the manual shutoff valve. • Check all fi ttings and connections of appliance w[...]
-
Page 16
Quadra-Fire • QVI-25FB-S • 2031-910 Rev . E • 9/08 16 Fire hazard. Do NOT change the valve settings. • This valve has been preset at the factory . • Changing valve settings may result in fi re hazard or bodily injury . HIGH AL TITUDE INST ALLA TIONS U.L. Listed gas appliances are tested and approved without requiring changes for elevatio[...]
-
Page 17
Quadra-Fire • QVI-25FB-S • 2031-910 Rev . E • 9/08 17 A. Wiring the Appliance 9 9 Elect rical Infor mation Note : This appliance must be electrically wired and grounded in accordance with local codes or , in the absence of local codes, with National Electric Code ANSI/NFP A 70-latest edition or the Canadian Electric Code, CSA C221.1. ON/OFF S[...]
-
Page 18
Quadra-Fire • QVI-25FB-S • 2031-910 Rev . E • 9/08 18 B. Junction Box Installation Figure 9.2 Junction box installation FEED PLUG THROUGH HOLE INSERT RELIEF AROUND CORD IN THIS END FROM OUTSIDE OF UNIT JUNCTION BOX SIDE WALL Optional Accessories Connecting the electrical junction box is required if using a blower or remote. • Plug the cord [...]
-
Page 19
Quadra-Fire • QVI-25FB-S • 2031-910 Rev . E • 9/08 19 Figure 9.4 Fan Wiring Diagram JUNCTION BOX VARIABLE SPEED CONTROL TEMPERATURE SENSOR SWITCH WHT GRN BLK BLK 110-120 VAC BLOWER BLOWER RECEPTACLE BLK BLK BLK BLK WHT GROUND WHT BLK BLK BLK REMOTE RECEPTACLE INSERT STUD THROUGH HOLE AND SECURE WITH WING NUT WING NUT TEMP SWITCH BRACKET FAN T[...]
-
Page 20
Quadra-Fire • QVI-25FB-S • 2031-910 Rev . E • 9/08 20 A. Mantel Projections Figure 10.1 shows the minimum vertical and corresponding maximum horizontal dimensions of appliance mantels or other combustible projections above the top front edge of the appliance, not the surround. 1 0 10 Fin ishing Figure 10 .1 Clearances to Mantels or other Comb[...]
-
Page 21
Quadra-Fire • QVI-25FB-S • 2031-910 Rev . E • 9/08 21 Figure 1 1.1 Placement of Embers BURNER P AN EMBER PLACEMENT 1 1 11 Appliance Setup A. Remove Shipping Materials Remove shipping materials from inside or underneath the fi rebox. B. Clean the Appliance Clean/vacuum any sawdust that may have accumulated inside the fi rebox or underneath i[...]
-
Page 22
Quadra-Fire • QVI-25FB-S • 2031-910 Rev . E • 9/08 22 E. Positioning the Logs Log Set Assembly: LOGS-2031 2031-700 4 5 6 1 3 2 FIREBOX LEDGE LOG PLACEMENT INSTRUCTIONS Log Placement CAUTION: Logs are fragile! Carefully remove the logs from the packaging. LOG #1 FIREBOX LEDGE FIREBOX FIREBOX LEDGE LOG #1 (SRV2032-701): Place log #1 on the fi [...]
-
Page 23
Quadra-Fire • QVI-25FB-S • 2031-910 Rev . E • 9/08 23 LOG #3 (SRV2032-703): Position log #3 by locating its slot over the tab on right front of the burner such that left end of log contacts log tab near the center of the burner . LOG #2 (SRV2032-702): Position log #2 by locating its slot over the tabs on left front of the burner . 2 2 3 3 LOG[...]
-
Page 24
Quadra-Fire • QVI-25FB-S • 2031-910 Rev . E • 9/08 24 Figure 1 1.2 Glass Assembly F . Glass Assembly Removing Glass Assembly There are two glass latches on the left side of glass as- sembly and two glass latches on the right side. • T o release glass assembly , pull latch forward and allow to retract away from glass assembly . • Remove gl[...]
-
Page 25
Quadra-Fire • QVI-25FB-S • 2031-910 Rev . E • 9/08 25 Fire Risk. Explosion Risk. Gas may build up while lighting pilot. • Remove glass assembly before lighting pilot. • Replace glass assembly after lighting pilot. A. Before Lighting Appliance This appliance has a Standing Pilot Ignition. Before operating this appliance have a qualified te[...]
-
Page 26
Quadra-Fire • QVI-25FB-S • 2031-910 Rev . E • 9/08 26 B. Lighting Appliance Standing Pilot Ignition 1. T urn off all electric power to the appliance if service is to be performed. 2. Open control access panel. 3. Move switch to “OFF” position. 4. Push in gas control knob slightly and turn clock- wise to OFF”. Do not force. 5. Close cont[...]
-
Page 27
Quadra-Fire • QVI-25FB-S • 2031-910 Rev . E • 9/08 27 C. Check Pilot Flame Appearance Pilot fl ame must contact the thermocouple and thermopile for reliable appliance operation. • Pilot fl ame should be as shown in Figure 12.1. D. After Appliance is Lit Initial Break-in Procedure When you light the appliance, you may notice that it pro- d[...]
-
Page 28
Quadra-Fire • QVI-25FB-S • 2031-910 Rev . E • 9/08 28 E. Frequently Asked Questions Fire Risk. High T emperatures. Keep combustible household items away from appliance. Do NOT obstruct combustion and ventilation air . • Do NOT place combustible items on top of or in front of appliance. • Keep furniture, draperies away from appliance. Smok[...]
-
Page 29
Quadra-Fire • QVI-25FB-S • 2031-910 Rev . E • 9/08 29 A. Standing Pilot Ignition System 1 3 13 T roubleshooting With proper installation, operation, and maintenance your gas appliance will provide years of trouble-free service. If you do experience a problem, this troubleshooting guide will assist a quali fi ed service person in the diagnosi[...]
-
Page 30
Quadra-Fire • QVI-25FB-S • 2031-910 Rev . E • 9/08 30 T roubleshooting (continued) Symptom Possible Cause Corrective Action 3. Continued c. Defective valve. T urn the valve knob to the ON position. Place the ON/OFF switch in the ON position. Check the millivolt meter a the thermopile terminals. The millivolt meter should read greater than 125[...]
-
Page 31
Quadra-Fire • QVI-25FB-S • 2031-910 Rev . E • 9/08 31 1 4 14 Maintaining and Ser vicing Appliance Although the frequency of appliance servicing and maintenance will depend on use and the type of installation, a quali fi ed service technician should perform an appliance checkup at the beginning of each heating season. Annual inspection by qua[...]
-
Page 32
Quadra-Fire • QVI-25FB-S • 2031-910 Rev . E • 9/08 32 Inspect Maintenance T asks Doors, Surrounds and Fronts 1. Assess condition of screen and replace as necessary . Recommend addition of screen if one is not present. 2. Inspect for scratches, dents or other damage and repair as necessary . 3. V erify no obstructions to air fl ow through the[...]
-
Page 33
Quadra-Fire • QVI-25FB-S • 2031-910 Rev . E • 9/08 33 Figure 15.1 Appliance Dimensions A 14-7/16 in. 377 mm C E 5-9/16 in. 1-1/16 in. G GAS INLET (GAS BALL V AL VE NOT SHOWN) H F D 3-5/8 in. REF 92 mm 3-7/16 in. 87 mm 1-1/16 in. 27 mm T wo 2-13/16 in. 71 mm B 4-3/8 in. 111 mm 1-9/16 in. 40 mm 1 5 15 Reference Materials A. Appliance Dimension [...]
-
Page 34
Quadra-Fire • QVI-25FB-S • 2031-910 Rev . E • 9/08 34 B. V ent Kits Components Direct V ent Flex Liner Kits (see Figure 15.2) LINK-DV -30B or (LINK-DV -30): Masonry 3 inch fl ex liner kit. Expands to 30 feet. Includes: two liners, termination cap, fl ashing, and link adapter . LINK-DV4-30B or (LINK-DV4-30): Masonry 3 inch fl ex liner kit. [...]
-
Page 35
Quadra-Fire • QVI-25FB-S • 2031-910 Rev . E • 9/08 35 Service Parts Diagram QVI-25FB-S R Beginning Manufacturing Date: Oct. 2007 Ending Manufacturing Date: ______ C. Service Parts List Part number list on following page. Log Set Assembly 4 2 1 3 5 6 7 8 9 10 11 12 13 14 15 16[...]
-
Page 36
Quadra-Fire • QVI-25FB-S • 2031-910 Rev . E • 9/08 36 QVI-25FB-S Service Parts IMPORT ANT : THIS IS DA TED INFORMA TION. When requesting service or replacement parts for your appliance please provide model number and serial number . All parts listed in this manual may be ordered from an authorized dealer . Stocked at Depot ITEM DESCRIPTION CO[...]
-
Page 37
Quadra-Fire • QVI-25FB-S • 2031-910 Rev . E • 9/08 37 IMPORT ANT : THIS IS DA TED INFORMA TION. When requesting service or replacement parts for your appliance please provide model number and serial number . All parts listed in this manual may be ordered from an authorized dealer . Stocked at Depot ITEM DESCRIPTION COMMENTS P ART NUMBER 1 Pil[...]
-
Page 38
Quadra-Fire • QVI-25FB-S • 2031-910 Rev . E • 9/08 38 D. Limited Lifetime W arranty Hearth & Home T echnologies LIMITED W ARRANTY Hearth & Home T echnologies (“HHT”) and its respective brands extends the following warranty for HHT gas, wood, pellet and electric appliances purchased from an authorized HHT dealer and installed in th[...]
-
Page 39
Quadra-Fire • QVI-25FB-S • 2031-910 Rev . E • 9/08 39 B. Limited Lifetime W arranty (continued) • This limited warranty does not extend to or include surface fi nish on the appliance or terminations, door gasketing, glass gasketing, glass discoloration, fi rebrick, pellet logs, kaowool or other ceramic insulating materials. Rust and/or co[...]
-
Page 40
Quadra-Fire • QVI-25FB-S • 2031-910 Rev . E • 9/08 40 Quadra-Fire, a brand of Hearth & Home T echnologies Inc. 20802 Kensington Boulevard, Lakeville, MN 55044 www .quadra fi re.com E. Contact Information Please contact your Quadra-Fire dealer with any questions or concerns. For the location of your nearest Quadra-Fire dealer , please vis[...]