Hearth and Home Technologies SL-750TRSFHHIPI manuel d'utilisation
- Voir en ligne ou télécharger le manuel d’utilisation
- 77 pages
- 5.26 mb
Aller à la page of
Les manuels d’utilisation similaires
-
Indoor Fireplace
Hearth and Home Technologies A42R
48 pages 4.25 mb -
Indoor Fireplace
Hearth and Home Technologies CD4236MLR
76 pages 8.38 mb -
Indoor Fireplace
Hearth and Home Technologies CNXT4236ILT
80 pages 8.84 mb -
Indoor Fireplace
Hearth and Home Technologies CB4236MIR
44 pages 3.06 mb -
Indoor Fireplace
Hearth and Home Technologies CD4842R
80 pages 8.29 mb -
Indoor Fireplace
Hearth and Home Technologies GDCR4136I
88 pages 5.97 mb -
Indoor Fireplace
Hearth and Home Technologies CNXT4236
4 pages 0.72 mb -
Indoor Fireplace
Hearth and Home Technologies EDV3633IL
60 pages 4.72 mb
Un bon manuel d’utilisation
Les règles imposent au revendeur l'obligation de fournir à l'acheteur, avec des marchandises, le manuel d’utilisation Hearth and Home Technologies SL-750TRSFHHIPI. Le manque du manuel d’utilisation ou les informations incorrectes fournies au consommateur sont à la base d'une plainte pour non-conformité du dispositif avec le contrat. Conformément à la loi, l’inclusion du manuel d’utilisation sous une forme autre que le papier est autorisée, ce qui est souvent utilisé récemment, en incluant la forme graphique ou électronique du manuel Hearth and Home Technologies SL-750TRSFHHIPI ou les vidéos d'instruction pour les utilisateurs. La condition est son caractère lisible et compréhensible.
Qu'est ce que le manuel d’utilisation?
Le mot vient du latin "Instructio", à savoir organiser. Ainsi, le manuel d’utilisation Hearth and Home Technologies SL-750TRSFHHIPI décrit les étapes de la procédure. Le but du manuel d’utilisation est d’instruire, de faciliter le démarrage, l'utilisation de l'équipement ou l'exécution des actions spécifiques. Le manuel d’utilisation est une collection d'informations sur l'objet/service, une indice.
Malheureusement, peu d'utilisateurs prennent le temps de lire le manuel d’utilisation, et un bon manuel permet non seulement d’apprendre à connaître un certain nombre de fonctionnalités supplémentaires du dispositif acheté, mais aussi éviter la majorité des défaillances.
Donc, ce qui devrait contenir le manuel parfait?
Tout d'abord, le manuel d’utilisation Hearth and Home Technologies SL-750TRSFHHIPI devrait contenir:
- informations sur les caractéristiques techniques du dispositif Hearth and Home Technologies SL-750TRSFHHIPI
- nom du fabricant et année de fabrication Hearth and Home Technologies SL-750TRSFHHIPI
- instructions d'utilisation, de réglage et d’entretien de l'équipement Hearth and Home Technologies SL-750TRSFHHIPI
- signes de sécurité et attestations confirmant la conformité avec les normes pertinentes
Pourquoi nous ne lisons pas les manuels d’utilisation?
Habituellement, cela est dû au manque de temps et de certitude quant à la fonctionnalité spécifique de l'équipement acheté. Malheureusement, la connexion et le démarrage Hearth and Home Technologies SL-750TRSFHHIPI ne suffisent pas. Le manuel d’utilisation contient un certain nombre de lignes directrices concernant les fonctionnalités spécifiques, la sécurité, les méthodes d'entretien (même les moyens qui doivent être utilisés), les défauts possibles Hearth and Home Technologies SL-750TRSFHHIPI et les moyens de résoudre des problèmes communs lors de l'utilisation. Enfin, le manuel contient les coordonnées du service Hearth and Home Technologies en l'absence de l'efficacité des solutions proposées. Actuellement, les manuels d’utilisation sous la forme d'animations intéressantes et de vidéos pédagogiques qui sont meilleurs que la brochure, sont très populaires. Ce type de manuel permet à l'utilisateur de voir toute la vidéo d'instruction sans sauter les spécifications et les descriptions techniques compliquées Hearth and Home Technologies SL-750TRSFHHIPI, comme c’est le cas pour la version papier.
Pourquoi lire le manuel d’utilisation?
Tout d'abord, il contient la réponse sur la structure, les possibilités du dispositif Hearth and Home Technologies SL-750TRSFHHIPI, l'utilisation de divers accessoires et une gamme d'informations pour profiter pleinement de toutes les fonctionnalités et commodités.
Après un achat réussi de l’équipement/dispositif, prenez un moment pour vous familiariser avec toutes les parties du manuel d'utilisation Hearth and Home Technologies SL-750TRSFHHIPI. À l'heure actuelle, ils sont soigneusement préparés et traduits pour qu'ils soient non seulement compréhensibles pour les utilisateurs, mais pour qu’ils remplissent leur fonction de base de l'information et d’aide.
Table des matières du manuel d’utilisation
-
Page 1
1 Heat & Glo • SL-750TRSFHHIPI • 2156-900 Rev . F • 1 1/08 • DO NOT store or use gasoline or other fl am- mable vapors and liquids in the vicinity of this or any other appliance. • What to do if you smell gas - DO NOT try to light any appliance. - DO NOT touch any electrical switch. DO NOT use any phone in your building. - Immediatel[...]
-
Page 2
2 Heat & Glo • SL-750TRSFHHIPI • 2156-900 Rev . F • 1 1/08 Listing Label Information/Location Model Name: ___________________________________________ Date purchased/installed: __________________ Serial Number: __________________________________________ Location on fi replace: _____________________ Dealership purchased from: _____________[...]
-
Page 3
3 Heat & Glo • SL-750TRSFHHIPI • 2156-900 Rev . F • 1 1/08 Safety Alert Key: • DANGER! Indicates a hazardous situation which, if not avoided will result in death or serious injury . • W ARNING! Indicates a hazardous situation which, if not avoided could result in death or serious injury . • CAUTION! Indicates a hazardous situation w[...]
-
Page 4
4 Heat & Glo • SL-750TRSFHHIPI • 2156-900 Rev . F • 1 1/08 = Contains updated information. 13 Finishing A. Splatter Guard . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53 B. Mantel and Wall Projections . . . . . . . . . . . . . . . . . . . . . . . 55 C. Facing Material . . . . . . . . . . . . . . . . . . . . . . . [...]
-
Page 5
5 Heat & Glo • SL-750TRSFHHIPI • 2156-900 Rev . F • 1 1/08 B. Limited Lifetime W arranty Hearth & Home T echnologies LIMITED W ARRANTY Hearth & Home T echnologies (“HHT”) and its respective brands extends the following warranty for HHT gas, wood, pellet and electric appliances purchased from an authorized HHT dealer and instal[...]
-
Page 6
6 Heat & Glo • SL-750TRSFHHIPI • 2156-900 Rev . F • 1 1/08 B. Limited Lifetime W arranty (continued) • This limited warranty does not extend to or include surface fi nish on the appliance or terminations, door gasketing, glass gasketing, glass discoloration, fi rebrick, pellet logs, kaowool or other ceramic insulating materials. Rust [...]
-
Page 7
7 Heat & Glo • SL-750TRSFHHIPI • 2156-900 Rev . F • 1 1/08 B. T empered Glass Speci fi cations Hearth & Home T echnologies appliances manufactured with tempered glass may be installed in hazardous loca- tions such as bathtub enclosures as de fi ned by the Con- sumer Product Safety Commission (CPSC). The tempered glass has been teste[...]
-
Page 8
8 Heat & Glo • SL-750TRSFHHIPI • 2156-900 Rev . F • 1 1/08 H. Requirements for the Commonwealth of Massachusetts For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole or in part for residential purposes, including those owned or operated by the Commonwealth and where th[...]
-
Page 9
9 Heat & Glo • SL-750TRSFHHIPI • 2156-900 Rev . F • 1 1/08 User Guide Figure 2.1 General Operating Parts B. Y our Fireplace W ARNING! DO NOT operate fi replace before read- ing and understanding operating instructions. Failure to operate fi replace according to operating instructions could cause fi re or injury . DECORA TIVE DOORS (NOT[...]
-
Page 10
10 Heat & Glo • SL-750TRSFHHIPI • 2156-900 Rev . F • 1 1/08 D. Clear Space W ARNING! DO NOT place combustible objects in front of the fi replace or block louvers. High temperatures may start a fi re. See Figure 2.2. Avoid placing candles and other heat-sensitive objects on mantel or hearth. Heat may damage these objects. Figure 2.2 Clea[...]
-
Page 11
11 Heat & Glo • SL-750TRSFHHIPI • 2156-900 Rev . F • 1 1/08 I. Lighting Instructions (IPI) The IPI system may be operated with two D-cell batteries. When using batteries, unplug the transformer . T o prolong battery life, remove them when using the transformer . 1. Turn off all electric power to the appliance. 2. This appliance is equippe[...]
-
Page 12
12 Heat & Glo • SL-750TRSFHHIPI • 2156-900 Rev . F • 1 1/08 J. After Fireplace is Lit Initial Break-in Procedure • The fireplace should be run three to four hours continuously on high. • T urn the fi replace off and allow it to completely cool. • Remove fi xed glass assembly . See Section 14.H. • Clean fi xed glass assembly . S[...]
-
Page 13
13 Heat & Glo • SL-750TRSFHHIPI • 2156-900 Rev . F • 1 1/08 Glass Cleaning Frequency: Seasonally By: Homeowner T ools Needed : Protective gloves, glass cleaner , drop cloth and a stable work surface. CAUTION! Handle fi xed glass assembly with care. Glass is breakable. • Avoid striking, scratching or slamming glass • Avoid abrasive cl[...]
-
Page 14
14 Heat & Glo • SL-750TRSFHHIPI • 2156-900 Rev . F • 1 1/08 V enting Frequency: Seasonally By: Homeowner T ools needed: Protective gloves and safety glasses. • Inspect venting and termination cap for blockage or obstruction such plants, bird nests, leaves, snow , debris, etc. • V erify termination cap clearance to subsequent construc-[...]
-
Page 15
15 Heat & Glo • SL-750TRSFHHIPI • 2156-900 Rev . F • 1 1/08 (Either cobrahead or SIT) PRODUCT SPECIFIC Figure 3.1 IPI Pilot Flame Patterns[...]
-
Page 16
16 Heat & Glo • SL-750TRSFHHIPI • 2156-900 Rev . F • 1 1/08 A. T ypical Appliance System NOTICE: Illustrations and photos re fl ect typical installations and are for design purposes only . Illustrations/diagrams are not drawn to scale. Actual product may vary from pictures in manual Figure 4.1 T ypical System 4 4 Get ting Star ted Instal[...]
-
Page 17
17 Heat & Glo • SL-750TRSFHHIPI • 2156-900 Rev . F • 1 1/08 B. Design and Installation Considerations Heat & Glo direct vent gas appliances are designed to operate with all combustion air siphoned from outside of the building and all exhaust gases expelled to the outside. No additional outside air source is required. Installation MUST[...]
-
Page 18
18 Heat & Glo • SL-750TRSFHHIPI • 2156-900 Rev . F • 1 1/08 5 5 F raming and Clearances A. Selecting Appliance Location When selecting a location for the appliance it is important to consider the required clearances to walls (see Figure 5.1). W ARNING! Risk of Fire or Burns! Provide adequate clearance around air openings and for service a[...]
-
Page 19
19 Heat & Glo • SL-750TRSFHHIPI • 2156-900 Rev . F • 1 1/08 B. Constructing the Appliance Chase A chase is a vertical box-like structure built to enclose the gas appliance and/or its vent system. In cooler climates the vent should be enclosed inside the chase. NOTICE: T reatment of ceiling fi restops and wall shield fi restops and const[...]
-
Page 20
20 Heat & Glo • SL-750TRSFHHIPI • 2156-900 Rev . F • 1 1/08 D. Mantel and W all Projections W ARNING! Risk of Fire! Comply with all minimum clear- ances as speci fi ed. Framing or fi nishing material closer than the minimums listed must be constructed entirely of noncom- bustible materials (i.e., steel studs, concrete board, etc). 3 FT [...]
-
Page 21
21 Heat & Glo • SL-750TRSFHHIPI • 2156-900 Rev . F • 1 1/08 Figure 6.3 Leveled T ermination Caps A. V ent T ermination Minimum Clearances Roof Pitch H (Min.) Ft. Flat to 6/12...........................................................1.0* Over 6/12 to 7/12 .................................................1.25* Over 7/12 to 8/12 ...........[...]
-
Page 22
22 Heat & Glo • SL-750TRSFHHIPI • 2156-900 Rev . F • 1 1/08 O N P R Q V = VENT TERMINAL X = AIR SUPPL Y INLET = AREA WHERE TERMINAL IS NOT PERMITTED Figure 6.4 Minimum Clearances for T ermination A = 12 inches................. clearances above grade, ver anda, porch, deck or balcony B = 12 inches................. clearances to window or d[...]
-
Page 23
23 Heat & Glo • SL-750TRSFHHIPI • 2156-900 Rev . F • 1 1/08 A. Approved Pipe This appliance is approved for use with Hearth & Home T echnologies DVP or SLP venting systems. Refer to Sec- tion 16B for vent component information. DO NOT mix pipe, fi ttings or joining methods from differ- ent manufacturers. The pipe is tested to be run [...]
-
Page 24
24 Heat & Glo • SL-750TRSFHHIPI • 2156-900 Rev . F • 1 1/08 E. Use of Flex V ent The fl ex vent must be supported with the spacing between support intervals not exceeding 4 feet, with no more than 1/2 inch sag between supports. A support is required at each change in venting direction, and in any location where it is necessary to maintai[...]
-
Page 25
25 Heat & Glo • SL-750TRSFHHIPI • 2156-900 Rev . F • 1 1/08 Figure 7.4 F . V ent Diagrams T op V ent - Horizontal T ermination V enting Note : Use SLP Series components only . Note : There MUST be a 25% reduction in total H when using fl ex vent except when using the simple up and out installation (see Figure 5.3). One Elbow Fire Risk. ?[...]
-
Page 26
26 Heat & Glo • SL-750TRSFHHIPI • 2156-900 Rev . F • 1 1/08 Figure 7.5 T wo Elbows V Minimum H Maximum SL-750TRSFHHIPI 90º Elbow NOT ALLOWED 1/2 ft.* 152 mm 1 ft. 305 mm 1-1/2 ft.* 457 mm 2 ft. 610 mm 2-1/2 ft.* 762 mm 4 ft. 1.2 m 3-1/2 ft. 1.1 m 6 ft 1.8 m 4-1/2 ft. 1.4 m 14 ft. 4.3 m H 1 + H 2 Maximum= 14 ft. (4.3 m) V 1 + H 1 + H 2 Ma[...]
-
Page 27
27 Heat & Glo • SL-750TRSFHHIPI • 2156-900 Rev . F • 1 1/08 Figure 7.6 Top Vent - Horizontal Termination - (continued) Three Elbows V 1 Minimum H 1 Maximum H 1 + H 2 Maximum V 2 V 1 + V 2 Minimum Elbow only 1 ft. 305 mm 2 ft. 610 mm * * 1/2 ft.** 152 mm 2 ft. 610 mm 4 ft. 1.2 m * * 1-1/2 ft.** 457 mm 3 ft. 914 mm 6 ft. 1.8 m * * Note : Us[...]
-
Page 28
28 Heat & Glo • SL-750TRSFHHIPI • 2156-900 Rev . F • 1 1/08 Figure 7.7 Figure 7.8 T op V ent - V ertical T ermination No Elbow V 1 = 60 ft. Max. (18.3 m) Note : Use SLP Series components only . INNER HEA T SHIELD T op V ent Application Rear V ent Application Note : Be sure to re- install the inner heat shield after exhaust restrictor inst[...]
-
Page 29
29 Heat & Glo • SL-750TRSFHHIPI • 2156-900 Rev . F • 1 1/08 Figure 7.9 T wo 90º Elbows V 1 Minimum H 1 Maximum V 2 V 1 + V 2 Minimum 90º Elbow 1 ft. 305 mm * * 1/2 ft. 152 mm 2 ft. 610 mm * * 1 ft. 305 mm 2-1/2 ft. 762 mm * * 2 ft. 610 mm 4 ft. 1.2 m * * 3 ft. 914 m 6 ft. 1.8 m * * 4 ft. 1.2 m 8 ft. 2.4 m * * 5 ft. 1.5 m 15 ft 4.6 m * *[...]
-
Page 30
30 Heat & Glo • SL-750TRSFHHIPI • 2156-900 Rev . F • 1 1/08 Figure 7.10 T op V ent - V ertical T ermination - (continued) Three 90º Elbows V 1 H 1 + H 2 Maximum V 2 V 1 + V 2 Minimum 90º Elbow 0 0 1-1/2 ft. 457 mm 1-1/2 ft. 457 mm 1/2 ft.. 152 mm 1 ft. 305 mm * * * * 1-1/2 ft. 457 mm 2 ft. 610 mm * * * * 2-1/2 ft. 762 mm 4 ft. 1.2 m * *[...]
-
Page 31
31 Heat & Glo • SL-750TRSFHHIPI • 2156-900 Rev . F • 1 1/08 V 1 H 1 V 2 V 3 H 2 Figure 7.1 1 T op V ent - V ertical T ermination - (continued) Four 90º Elbows V 1 Min. H 1 Max. V 2 Min. H 2 Max. V 3 Min. 1-1/2 ft. 457 mm 4 ft. 1.2 m 4 ft. 1.2 m 4 ft. 1.2 m 3-1/2 ft. 1.0 m V 1 + V 2 + V 3 + H 1 + H 2 Maximum= 40 ft. (12.2 m) Note : Use SL[...]
-
Page 32
32 Heat & Glo • SL-750TRSFHHIPI • 2156-900 Rev . F • 1 1/08 H 1 H 2 V 1 Figure 7.12 Figure 7.13 T wo 90º Elbows Rear V ent - Horizontal T ermination No Elbow H 1 = 24 in. (610 mm) Maximum H 1 Maximum V 1 Minimum H 2 H 1 + H 2 Maximum 1-1/2 ft. 457 mm Back to Back Elbows 1 ft. 305 mm 2-1/2 ft. 762 mm 3-1/2 ft. 1.1 m 1 ft. 305 mm 3 ft. 914[...]
-
Page 33
33 Heat & Glo • SL-750TRSFHHIPI • 2156-900 Rev . F • 1 1/08 Figure 7.14 Rear V ent - Horizontal T ermination - (continued) Three Elbows H 1 Maximum V 1 Minimum H 2 + H 3 H 1 + H 2 + H 3 Maximum 1-1/2 ft. 457 mm Back to Back Elbows 1 ft. 305 mm 2-1/2 ft. 762 mm 3-1/2 ft. 1.1 m 1 ft. 305 mm 2 ft. 610 mm 5-1/2 ft. 1.7 m 5-1/2 ft. 1.7 m 2 ft.[...]
-
Page 34
34 Heat & Glo • SL-750TRSFHHIPI • 2156-900 Rev . F • 1 1/08 Figure 7.16 Figure 7.17 T wo Elbows H 1 Maximum V 1 Minimum H 2 H 1 + H 2 Maximum 1-1/2 ft. 457 mm Back to Back Elbows 1 ft. 305 mm 2-1/2 ft. 762 mm 3-1/2 ft. 1.1 m 1 ft. 305 mm 3 ft. 914 mm 6-1/2 ft. 2.0 m 5-1/2 ft. 1.2 m 2 ft. 610 mm 5 ft. 1.5 m 10-1/2 ft. 3.2 m 7-1/2 ft. 2.3 m[...]
-
Page 35
35 Heat & Glo • SL-750TRSFHHIPI • 2156-900 Rev . F • 1 1/08 A. Pipe Clearances to Combustibles W ARNING! Risk of Fire! Maintain air space clearance to vent. DO NOT pack insulation or other combustibles: • Between ceiling fi restops • Between wall shield fi restops • Around vent system Failure to keep insulation or other material a[...]
-
Page 36
36 Heat & Glo • SL-750TRSFHHIPI • 2156-900 Rev . F • 1 1/08 C. Install the Ceiling Firestop A ceiling fi restop MUST be used between fl oors and attics. • DVP pipe only - Frame an opening 10 in. by 10 in. (254 mm by 254 mm) whenever the vent penetrates a ceiling/ fl oor (see Figure 8.3). • SLP pipe only - Frame opening 9 in. x 9 in[...]
-
Page 37
37 Heat & Glo • SL-750TRSFHHIPI • 2156-900 Rev . F • 1 1/08 D. Install Attic Insulation Shield W ARNING! Fire Risk. DO NOT allow loose materials or insulation to touch vent. Hearth & Home T echnologies Inc. requires the use of an attic shield. The National Fuel Gas Code ANSI Z223.1 and NFPA 54 requires an attic shield constructed of 2[...]
-
Page 38
38 Heat & Glo • SL-750TRSFHHIPI • 2156-900 Rev . F • 1 1/08 CAUTION! Risk of Cuts, Abrasions or Flying Debris. Wear protective gloves and safety glasses during instal- lation. Sheet metal edges are sharp. NOTICE: Once appliance is set up for top or rear venting, it CANNOT be changed at a later time. A. T op V ent 9 9 Appliance Preparation[...]
-
Page 39
39 Heat & Glo • SL-750TRSFHHIPI • 2156-900 Rev . F • 1 1/08 B. Rear V ent NOTICE: Once appliance is set up for top or rear venting, it CANNOT be changed at a later time. NOTICE: Once the seal cap has been removed it CANNOT be reattached. Figure 9.8 Fold the tabs toward the center of the fi re plug (90°) and remove the insulation gasket.[...]
-
Page 40
40 Heat & Glo • SL-750TRSFHHIPI • 2156-900 Rev . F • 1 1/08 C. Securing and Leveling the Appliance W ARNING! Risk of Fire! Prevent contact with: • Sagging or loose insulation • Insulation backing or plastic • Framing and other combustible materials Block openings into the chase to prevent entry of blown- in insulation. Make sure ins[...]
-
Page 41
41 Heat & Glo • SL-750TRSFHHIPI • 2156-900 Rev . F • 1 1/08 1 0 10 Installing V ent Pipe ( D VP and SLP P ipe ) A. Assemble V ent Sections (DVP Pipe Only) Attach V ent to the Firebox Assembly Note: The end of t he pipe secti ons with the lanc ed tabs wi ll face toward the applianc e. Attach the fi rst pipe section to the starting collar:[...]
-
Page 42
42 Heat & Glo • SL-750TRSFHHIPI • 2156-900 Rev . F • 1 1/08 B. Assemble V ent Sections (SLP Pipe Only) T o attach the fi rst vent component to the starting collars of the appliance: • Lock the vent components into place by sliding the pipe section onto the collar . • Align the seam of the pipe and seam of collar to allow engagement. [...]
-
Page 43
43 Heat & Glo • SL-750TRSFHHIPI • 2156-900 Rev . F • 1 1/08 120º Figure 10.8 Securing V ertical Pipe Sections 120º Figure 10.9 Securing Horizontal Pipe Sections E. Disassemble V ent Sections • Rotate either section (see Figure 10.10) so the seams on both pipe sections are aligned as shown in Figure 10.1 1. • Pull carefully to separa[...]
-
Page 44
44 Heat & Glo • SL-750TRSFHHIPI • 2156-900 Rev . F • 1 1/08 F . Install Decorative Ceiling Components (SLP only) A decorative ceiling thimble can be installed on a fl at ceil- ing through which the vent passes. The decorative ceiling thimble is used to cover the fi restop. • Seal the gap between the vent pipe and fi restop using high[...]
-
Page 45
45 Heat & Glo • SL-750TRSFHHIPI • 2156-900 Rev . F • 1 1/08 G. Install Metal Roof Flashing Note : Skip this section if using the RF4-8. • See minimum vent heights for various pitched roofs (Figure 10.14) to determine the length of pipe to extend through the roof. • Slide the roof fl ashing over the pipe sections extending through the[...]
-
Page 46
46 Heat & Glo • SL-750TRSFHHIPI • 2156-900 Rev . F • 1 1/08 I. Install RF4-8 The RF4-8 may be used in place of the roof fl ashing and storm collar (Sections 10.G. and 10.H.) Pipe must be supported within 12 inches of the roofline using plumbers strapping or an SLP-FS when using the RF4-8 Flashing. Refer to Section 10.D. Secure Vent Secti[...]
-
Page 47
47 Heat & Glo • SL-750TRSFHHIPI • 2156-900 Rev . F • 1 1/08 SCREWS CAULK STORM COLLAR (1 of 3) Figure 10.23 Figure 10.23 TERMINA TION CAP J. Install V ertical T ermination Cap • Attach the vertical termination cap by sliding the inner collar of the cap into the inner fl ue of the pipe section while placing the outer collar of the cap o[...]
-
Page 48
48 Heat & Glo • SL-750TRSFHHIPI • 2156-900 Rev . F • 1 1/08 Figure 10.25 Venting through the wall INTERIOR HEA T SHIELD OR EXTENDED HEA T SHIELD W ALL SHIELD FIRESTOP HEA T SHIELD 1-1/2 IN. (38 MM) MIN. OVERLAP SHEA THING VENT DEPTH FROM BACK OF APPLIANCE T O OUTSIDE SURF ACE OF EXTERIOR WA LL (SEE CHART BELOW) SLIP SECTION CAN BE EXTENDE[...]
-
Page 49
49 Heat & Glo • SL-750TRSFHHIPI • 2156-900 Rev . F • 1 1/08 A. Fuel Conversion • Make sure the appliance is compatible with available gas types. • Conversions must be made by a qualified service technician using Hearth & Home T echnologies speci fi ed and approved parts. B. Gas Pressure • Optimum appliance performance requires [...]
-
Page 50
50 Heat & Glo • SL-750TRSFHHIPI • 2156-900 Rev . F • 1 1/08 A. Wiring Requirements NOTICE: This appliance must be electrically wired and grounded in accordance with local codes or , in the absence of local codes, with National Electric Code ANSI/NFP A 70-latest edition or the Canadian Electric Code CSA C22.1. • Wire the appliance juncti[...]
-
Page 51
51 Heat & Glo • SL-750TRSFHHIPI • 2156-900 Rev . F • 1 1/08 TRANSFORMER 3 V AC PLUG IN BLACK RED BA TTERY P ACK THERMOST AT WIRE ASSEMBL Y WIRES (TO BROWN) ORANGE GREEN VA LV E WHITE ORANGE IGNITION MODULE 3 V AC INTERMITTENT PILOT IGNITOR HOT NEUTRAL I S GROUND TO FIREPLACE CHASSIS Figure 12.1 Intelli fi re Ignition Wiring Diagram with [...]
-
Page 52
52 Heat & Glo • SL-750TRSFHHIPI • 2156-900 Rev . F • 1 1/08 F . W all Switch Installation for Fan (Optional) If the box is being wired to a wall mounted switch for use with a fan (See Figure 12.4): • The power supply for the appliance must be brought into a switch box. • The power can then be supplied from the switch box to the applia[...]
-
Page 53
53 Heat & Glo • SL-750TRSFHHIPI • 2156-900 Rev . F • 1 1/08 A. Splatter Guard The splatter guard is a piece of corrugated material used to protect the appliance during the installation process before fi nishing work on the whole hearth is complete. Splatter guards may be factory installed or accompany the door of the unit, depending on t[...]
-
Page 54
54 Heat & Glo • SL-750TRSFHHIPI • 2156-900 Rev . F • 1 1/08 Step 5. Fold bottom fl ap along score line as indicated in Figure 13.6 and tuck into valve access area of appliance. Splatter guard should fi t securely on front of unit. Figure 13.6 Once plumbing and wiring are complete on the fi replace, the lower access panel may be closed [...]
-
Page 55
55 Heat & Glo • SL-750TRSFHHIPI • 2156-900 Rev . F • 1 1/08 B. Mantel and W all Projections W ARNING! Risk of Fire! Comply with all minimum clear- ances as speci fi ed. Framing closer than the minimums list- ed must be constructed entirely of noncombustible materi- als (i.e., steel studs, concrete board, etc.) Failure to comply could cau[...]
-
Page 56
56 Heat & Glo • SL-750TRSFHHIPI • 2156-900 Rev . F • 1 1/08 C. Facing Material • Metal front faces may be covered with non-combustible materials only . • Facing and/or fi nishing materials must not interfere with air fl ow through louvers, operation of louvers or doors, or access for service. • Facing and/or fi nishing materials [...]
-
Page 57
57 Heat & Glo • SL-750TRSFHHIPI • 2156-900 Rev . F • 1 1/08 D. Doors Only doors certi fi ed for use with this appliance model may be used. Contact your dealer for a list of doors that may be used. Once you have determined what kind of door and fi nishing material is going to be used on the fi replace, you may use the table below which [...]
-
Page 58
58 Heat & Glo • SL-750TRSFHHIPI • 2156-900 Rev . F • 1 1/08 E. Elevated Hearth Systems Use the table below to identify the hearth system that will be used. The table will also help identify ef fects on the various dimensions. Some hearth systems will elevate the appliance off the fl oor at a given dimension. For example, if appliance wil[...]
-
Page 59
59 Heat & Glo • SL-750TRSFHHIPI • 2156-900 Rev . F • 1 1/08 A. Remove Fixed Glass Assembly See Section 14.H. B. Remove the Shipping Materials Remove shipping materials from inside or underneath the fi rebox. C. Clean the Appliance Clean/vacuum any sawdust that may have accumulated inside the fi rebox or underneath in the control cavity [...]
-
Page 60
60 Heat & Glo • SL-750TRSFHHIPI • 2156-900 Rev . F • 1 1/08 F . Install Refractory Figure 14.5 Figure 14.4 Figure 14.6 Step 2. Place the right refractory against the fi rebox right wall such that it is against the back refractory (see Figure 14.5). Step 3. Bend left and right refractory retainer tabs to keep side pieces from tipping (see[...]
-
Page 61
61 Heat & Glo • SL-750TRSFHHIPI • 2156-900 Rev . F • 1 1/08 G. Install the Log Assembly STEP 1. CAUTION: Logs are fragile! Carefully remove the logs from the packaging. LOG NOTCHES STEP 2. LOG #1 (SRV2065-701) Place log #1 on left fl at side of the burner assembly . Pull the log forward and slide it to the right until the notches under t[...]
-
Page 62
62 Heat & Glo • SL-750TRSFHHIPI • 2156-900 Rev . F • 1 1/08 STEP 4. LOG #3 (SRV2066-703) Place log #3 on right side of grate. The notch on the log should fi t over the bar on the far right side of the grate. Push the right side of log #3 against the grate tab and pull the left side forward until it comes into contact with the burner deta[...]
-
Page 63
63 Heat & Glo • SL-750TRSFHHIPI • 2156-900 Rev . F • 1 1/08 Figure 14.9 Fixed Glass Assembly H. Fixed Glass Assembly W ARNING! Risk of Asphyxiation! Handle fi xed glass assembly with care. Inspect the gasket to ensure it is undamaged and inspect the glass for cracks, chips or scratches. • DO NOT strike, slam or scratch glass. • DO NO[...]
-
Page 64
64 Heat & Glo • SL-750TRSFHHIPI • 2156-900 Rev . F • 1 1/08 1 5 15 T roubleshooting With proper installation, operation, and maintenance your gas appliance will provide years of trouble-free service. If you do experience a problem, this troubleshooting guide will assist a quali fi ed service technician in the diagnosis of a problem and t[...]
-
Page 65
65 Heat & Glo • SL-750TRSFHHIPI • 2156-900 Rev . F • 1 1/08 Intelli fi re Ignition System - (continued) Symptom Possible Cause Corrective Action 4. Pilot lights but contin- ues to spark, and main burner will not ignite. (If the pilot continues to spark after the pilot fl ame has been lit, fl ame recti fi cation has not occurred.) A. A[...]
-
Page 66
66 Heat & Glo • SL-750TRSFHHIPI • 2156-900 Rev . F • 1 1/08 1 6 16 R eference Mater ials A. Appliance Dimension Diagram Dimensions are actual appliance dimensions. Use for reference only . For framing dimensions and clearances refer to Section 5. Figure 16.1 Appliance Dimensions Location Inches Millimeters A 41 1041 B 36-1/8 917 C 32-1/16[...]
-
Page 67
67 Heat & Glo • SL-750TRSFHHIPI • 2156-900 Rev . F • 1 1/08 B. V ent Components Diagrams Figure 16.2 DVP vent components Pipe Effective Length Inches Millimeters DVP4 4 102 DVP6 6 152 DVP12 12 305 DVP24 24 610 DVP36 36 914 DVP48 48 1219 DVP6A 3 to 6 76 to 152 DVP12A 3 to 12 76 to 305 DVP12MI 3 to 12 76 to 305 DVP24MI 3 to 24 76 to 610 10-[...]
-
Page 68
68 Heat & Glo • SL-750TRSFHHIPI • 2156-900 Rev . F • 1 1/08 B. V ent Components Diagrams (continued) Figure 16.3 DVP vent components DVP-HPC1 DVP-HPC2 DVP-TRAP1 DVP-TRAP2 DVP-TRAPK2 DVP-TRAPK1 DVP-TRAP Horizontal T ermination Cap 15-1/8 in. (384 mm) 12 in. (305 mm) 8 in. (203 mm) Max Effective Length Note: Heat shields MUST overlap by a m[...]
-
Page 69
69 Heat & Glo • SL-750TRSFHHIPI • 2156-900 Rev . F • 1 1/08 B. V ent Components Diagrams (continued) Figure 16.4 DVP vent components 13-1/4 in. (367 mm) 24-5/8 in. (625 mm) 27-1/2 in. (127 mm) RF6M Roof Flashing Multi-pak 31 in. (787 mm) 24-5/8 in. (625 mm) 13-1/4 in. (367 mm) RF12M Roof Flashing Multi-pak BEK Trap Ca p Brick Extension 13[...]
-
Page 70
70 Heat & Glo • SL-750TRSFHHIPI • 2156-900 Rev . F • 1 1/08 B. V ent Components Diagrams (continued) Figure 16.5 DVP vent components DVP-TB1 BasementVent Cap 12 in. (305 mm) 1-1/2 in. (38 mm) 7-3/8 in. (187 mm) 14 in. (356 mm) 17-3/4 in. (451 mm) 10-1/2 in. (267 mm) 3-7/8 in. (98 mm) DVP-TV VerticalTermination Cap 7-1/4 in. 12 in. 305 mm [...]
-
Page 71
71 Heat & Glo • SL-750TRSFHHIPI • 2156-900 Rev . F • 1 1/08 B. V ent Components Diagrams (continued) Figure 16.7 SLP Series V ent Components Figure 16.6 DVP vent components Fire Risk. • When using SLP-HRC-SS and SLP-HRC-ZC- SS termination caps on top vented fi replaces, a one foot minimum vertical vent section is required before instal[...]
-
Page 72
72 Heat & Glo • SL-750TRSFHHIPI • 2156-900 Rev . F • 1 1/08 B. V ent Components Diagrams (continued) Figure 16.8 SLP Series V ent Components 8-3/4 in. 222 mm 6-1/2 in. 165 mm 6-5/8 in. 168 mm SLP45 45° Elbow Effective Height/ Length SLP-PIPE SLP-FLEX-PIPE SLP-HVS Horizontal Pipe Support RF4-8 Roof Flashing SLP-FS Ceiling Firestop SLP-WS [...]
-
Page 73
73 Heat & Glo • SL-750TRSFHHIPI • 2156-900 Rev . F • 1 1/08 B. V ent Components Diagrams (continued) Figure 16.9 SLP Series V ent Components SLK-SNKD Snorkel T ermination Cap SLP-TVHW V ertical T ermination Cap SLP-FLEX-TRAP Horizontal T ermination Kit SLP-CCS-BK Cathedral Ceiling Support Box-Black SLP-DCF-BK Ceiling Firestop Black SLP-WT[...]
-
Page 74
74 Heat & Glo • SL-750TRSFHHIPI • 2156-900 Rev . F • 1 1/08 C. Service Parts Service Parts Diagram Log Set Assembly Part number list on following page. SL-750TRSFHHIPI Beginning Manufacturing Date: Oct. 2007 Ending Manufacturing Date: ______ 9 7 8 10 11 12 13 14 15 16 6 17 1 2 3 4 5[...]
-
Page 75
75 Heat & Glo • SL-750TRSFHHIPI • 2156-900 Rev . F • 1 1/08 SL-750TRSFHHIPI Service Parts List IMPORT ANT : THIS IS DA TED INFORMA TION. When requesting service or replacement parts for your appliance please provide model number and serial number . All parts listed in this manual may be ordered from an authorized dealer . Stocked at Depot[...]
-
Page 76
76 Heat & Glo • SL-750TRSFHHIPI • 2156-900 Rev . F • 1 1/08 V alve Assembly Parts List Service Parts IPI V alve Assembly SL-750TRSFHHIPI Beginning Manufacturing Date: Oct. 2007 Ending Manufacturing Date: ______ IMPORT ANT : THIS IS DA TED INFORMA TION. When requesting service or replacement parts for your appliance please provide model nu[...]
-
Page 77
77 Heat & Glo • SL-750TRSFHHIPI • 2156-900 Rev . F • 1 1/08 Heat & Glo, a brand of Hearth & Home T echnologies Inc. 7571 215th St, Lakeville, MN 55044 www .heatnglo.com D. Contact Information Please contact your Heat & Glo dealer with any questions or concerns. For the location of your nearest Heat & Glo dealer , please vi[...]