Lennox International Inc. 506945-01 manuel d'utilisation
- Voir en ligne ou télécharger le manuel d’utilisation
- 15 pages
- 0.44 mb
Aller à la page of
Les manuels d’utilisation similaires
-
Air Conditioner
Lennox International Inc. CONDENSING UNITS
30 pages 1.35 mb -
Air Conditioner
Lennox International Inc. 10GCS
4 pages 0.65 mb -
Air Conditioner
Lennox International Inc. 11
4 pages 0.37 mb -
Air Conditioner
Lennox International Inc. WING
34 pages 2.76 mb -
Air Conditioner
Lennox International Inc. LENNOX Elite Series XP13 Units HEAT PUMPS
32 pages 0.94 mb -
Air Conditioner
Lennox International Inc. Lennox Healthy Climate
3 pages 0.14 mb -
Air Conditioner
Lennox International Inc. 12GCS
4 pages 0.65 mb -
Air Conditioner
Lennox International Inc. Dave Lennox Signature Collection XC17 Air Conditioner
49 pages 1.7 mb
Un bon manuel d’utilisation
Les règles imposent au revendeur l'obligation de fournir à l'acheteur, avec des marchandises, le manuel d’utilisation Lennox International Inc. 506945-01. Le manque du manuel d’utilisation ou les informations incorrectes fournies au consommateur sont à la base d'une plainte pour non-conformité du dispositif avec le contrat. Conformément à la loi, l’inclusion du manuel d’utilisation sous une forme autre que le papier est autorisée, ce qui est souvent utilisé récemment, en incluant la forme graphique ou électronique du manuel Lennox International Inc. 506945-01 ou les vidéos d'instruction pour les utilisateurs. La condition est son caractère lisible et compréhensible.
Qu'est ce que le manuel d’utilisation?
Le mot vient du latin "Instructio", à savoir organiser. Ainsi, le manuel d’utilisation Lennox International Inc. 506945-01 décrit les étapes de la procédure. Le but du manuel d’utilisation est d’instruire, de faciliter le démarrage, l'utilisation de l'équipement ou l'exécution des actions spécifiques. Le manuel d’utilisation est une collection d'informations sur l'objet/service, une indice.
Malheureusement, peu d'utilisateurs prennent le temps de lire le manuel d’utilisation, et un bon manuel permet non seulement d’apprendre à connaître un certain nombre de fonctionnalités supplémentaires du dispositif acheté, mais aussi éviter la majorité des défaillances.
Donc, ce qui devrait contenir le manuel parfait?
Tout d'abord, le manuel d’utilisation Lennox International Inc. 506945-01 devrait contenir:
- informations sur les caractéristiques techniques du dispositif Lennox International Inc. 506945-01
- nom du fabricant et année de fabrication Lennox International Inc. 506945-01
- instructions d'utilisation, de réglage et d’entretien de l'équipement Lennox International Inc. 506945-01
- signes de sécurité et attestations confirmant la conformité avec les normes pertinentes
Pourquoi nous ne lisons pas les manuels d’utilisation?
Habituellement, cela est dû au manque de temps et de certitude quant à la fonctionnalité spécifique de l'équipement acheté. Malheureusement, la connexion et le démarrage Lennox International Inc. 506945-01 ne suffisent pas. Le manuel d’utilisation contient un certain nombre de lignes directrices concernant les fonctionnalités spécifiques, la sécurité, les méthodes d'entretien (même les moyens qui doivent être utilisés), les défauts possibles Lennox International Inc. 506945-01 et les moyens de résoudre des problèmes communs lors de l'utilisation. Enfin, le manuel contient les coordonnées du service Lennox International Inc. en l'absence de l'efficacité des solutions proposées. Actuellement, les manuels d’utilisation sous la forme d'animations intéressantes et de vidéos pédagogiques qui sont meilleurs que la brochure, sont très populaires. Ce type de manuel permet à l'utilisateur de voir toute la vidéo d'instruction sans sauter les spécifications et les descriptions techniques compliquées Lennox International Inc. 506945-01, comme c’est le cas pour la version papier.
Pourquoi lire le manuel d’utilisation?
Tout d'abord, il contient la réponse sur la structure, les possibilités du dispositif Lennox International Inc. 506945-01, l'utilisation de divers accessoires et une gamme d'informations pour profiter pleinement de toutes les fonctionnalités et commodités.
Après un achat réussi de l’équipement/dispositif, prenez un moment pour vous familiariser avec toutes les parties du manuel d'utilisation Lennox International Inc. 506945-01. À l'heure actuelle, ils sont soigneusement préparés et traduits pour qu'ils soient non seulement compréhensibles pour les utilisateurs, mais pour qu’ils remplissent leur fonction de base de l'information et d’aide.
Table des matières du manuel d’utilisation
-
Page 1
7/2012 506945-01 *2P72012* *P506945-01* Page 1 E 2013 Lennox Industries Inc. Dallas, T exas, USA THIS MANUAL MUST BE LEFT WITH THE HOMEOWNER FOR FUTURE REFERENCE W ARNING The State of California has determined that this product may contain or produce a chemical or chemicals, in very low doses, which may cause serious illness or death. It may also c[...]
-
Page 2
Page 2 A B SIDE VIEW UNIT DIMENSIONS - INCHES (MM) FIGURE 2 T ABLE 1 UNIT DIMENSIONS Model Numbers A B 13ACX-018-230 24-1/4 (616) 25-1/4 (641) 13ACX-024-230 24-1/4 (616) 25-1/4 (641) 13ACX-030-230 24-1/4 (616) 29-1/4 (743) 13ACX-036-230 24-1/4 (616) 29-1/4 (743) 13ACX-042-230 28-1/4 (718) 29-1/4 (743) 13ACX-048-230 28-1/4 (718) 33-1/4 (845) 13ACX-0[...]
-
Page 3
Page 3 13ACX SERIES ANCHORED HEA VY NYLON WIRE TIE OR AUT OMOTIVE MUFFLER‐TYPE HANGER STRAP LIQUID LINE TO V APOR LINE W ALL STUD LIQUID LINE NON-CORROSIVE MET AL SLEEVE V APOR LINE - WRAPPED IN ARMAFLEX AUT OMOTIVE MUFFLER‐TYPE HANGER REFRIGERANT LINE SET — TRANSITION FROM VERTICAL TO HORIZONT AL Line Set Isolation — The following illustra[...]
-
Page 4
Page 4 STEP 2 -- REFRIGERANT PIPING -- Flushing Existing Line Set and Indoor Coil Flush the existing line set per the following instructions. For more information, refer to the Installation and Service Procedures manual available on DaveNet. CAUTION - DO NOT attempt to flush and re-use existing line sets or indoor coil when the system contains cont[...]
-
Page 5
Page 5 13ACX SERIES STEP 2 -- REFRIGERANT PIPING -- Removing Existing Indoor Metering Device SENSING LINE TEFLON ® RING FIXED ORIFICE BRASS NUT LIQUID LINE ASSEMBL Y (INCLUDES STRAINER) LIQUID LINE ORIFICE HOUSING DISTRIBUT OR TUBES DISTRIBUT OR ASSEMBL Y REMOVE AND DISCARD WHITE TEFLON ® SEAL (IF PRESENT) A On fully cased coils, remove the coil [...]
-
Page 6
Page 6 STEP 2 -- REFRIGERANT PIPING -- Brazing Procedures A TT ACH THE MANIFOLD GAUGE SET FOR BRAZING LIQUID AND SUCTION / V APOR LINE SERVICE V AL VES OUTDOOR UNIT LIQUID LINE V APOR LINE LIQUID LINE SERVICE VA LV E SUCTION / V APOR LINE SER VICE VA LV E A TT ACH GAUGES INDOOR UNIT SUCTION / V APOR SERVICE PORT MUST BE OPEN TO ALLOW EXIT POINT FOR[...]
-
Page 7
Page 7 13ACX SERIES WHEN BRAZING LINE SET TO SER VICE V AL VES, POINT FLAME A WA Y FROM SER VICE V AL V E. LIQUID LINE SERVICE V AL VE LIQUID LINE BRAZE LINE SET Wra p both service valves with water -saturated cloths as illustrated here and as mentioned in step 4, before brazing to line set. Cloths must remain water-saturated throughout the brazing[...]
-
Page 8
Page 8 STEP 2 -- REFRIGERANT PIPING -- Installing Indoor Expansion V alve This outdoor unit is designed for use in systems that use either an fixed orifice (RFC) (included with outdoor unit), or expansion valve metering device (purchased separately) at the indoor coil. Se e t he 13ACX Product Specifications bulletin (EHB) for approved expansion val[...]
-
Page 9
Page 9 13ACX SERIES STEP 3 -- LEAK TEST AND EV ACUA TION A With both manifold valves closed, connect the cylinder of HFC-410A refrigerant to the center port of the manifold gauge set. Open the valve on the HFC-410A cylinder (vapor only). B Open the high pressure side of the manifold to allow HFC-410A into the line set and indoor unit. W eigh in a t[...]
-
Page 10
Page 10 STEP 3 -- LEAK TEST AND EV ACUA TION (CONTINUED) A Open both manifold valves and start the vacuum pum p. B Evacuate the line set and indoor unit to an absolute pressure of 23,000 microns (29.01 inches of mercury). NOTE — During the early stages of evacuation, it is desirable to close the manifold gauge valve at least once. A rapid rise in[...]
-
Page 11
Page 1 1 13ACX SERIES STEP 4 -- ELECTRICAL -- Circuit Sizing and Wire Routing In t he U .S .A., w iring must conform with current local codes a nd the current National Electric Code (NEC). In Canada, wiring must conform with cur rent local codes and the current Canadian Elec trical Code (CEC ). Refer to the furnace or air handler installation instr[...]
-
Page 12
Page 12 STEP 4 -- ELECTRICAL (CONTINUED) -- High V oltage and Field Control Wiring The following illustration provide an example of control wiring connections when using standard thermostat. Any excess high voltage field wiring should be trimmed and secured away from any low voltage field wiring. T o facilitate a conduit, a cutout is located in the[...]
-
Page 13
Page 13 13ACX SERIES T ABL E 3 . T O RQUE REQUIREM ENTS Parts Recommended Torque Service valve cap 8 ft.- lb. 1 1 NM Sheet metal screws 16 in.- lb. 2 NM Machine screws #10 28 in.- lb. 3 NM Compressor bolts 90 in.- lb. 10 NM Gauge port seal cap 8 ft.- lb. 1 1 NM Using Manifold Gauge Set When checking the system charge, only use a manifold gauge set [...]
-
Page 14
Page 14 CHECKING AND ADDING SYSTEM REFRIGERANT The 13ACX unit is factory-charged with enough HFC-410A refrigerant to accommodate a 15-foot length of refrigerant piping. Charge should be checked and adjusted using the tables provided on the charging procedure sticker located o n th e unit access panel. Detailed information is provided in th e 13ACX [...]
-
Page 15
Page 15 13ACX SERIES 13ACX Start-Up and Performance Checklist Customer Address Indoor Unit Model Serial Outdoor Unit Model Serial Notes: ST ART UP CHECKS Refrigerant T ype: Rated Load Amps: Actual Amps Rated V olts Actual V olts Condenser Fan Full Load Amps Actual Amps: COOLING MODE Suction Pressure: Liquid Pressure: Supply Air T emperature: Ambien[...]