Lennox International Inc. XP1906 manuel d'utilisation
- Voir en ligne ou télécharger le manuel d’utilisation
- 72 pages
- 0.67 mb
Aller à la page of
Les manuels d’utilisation similaires
-
Thermostat
Lennox International Inc. 81M28
28 pages 0.47 mb -
Thermostat
Lennox International Inc. Ellite Series
32 pages 0.34 mb -
Thermostat
Lennox International Inc. l7742u
15 pages 0.41 mb -
Thermostat
Lennox International Inc. 2P1109
39 pages 0.32 mb -
Thermostat
Lennox International Inc. EL296V01
72 pages 0.67 mb -
Thermostat
Lennox International Inc. iComfort Wifi Thermostat
72 pages 0.67 mb -
Thermostat
Lennox International Inc. Touch Screen Programmable Communicating Thermostat
39 pages 0.32 mb -
Thermostat
Lennox International Inc. CBX32MV06
72 pages 0.67 mb
Un bon manuel d’utilisation
Les règles imposent au revendeur l'obligation de fournir à l'acheteur, avec des marchandises, le manuel d’utilisation Lennox International Inc. XP1906. Le manque du manuel d’utilisation ou les informations incorrectes fournies au consommateur sont à la base d'une plainte pour non-conformité du dispositif avec le contrat. Conformément à la loi, l’inclusion du manuel d’utilisation sous une forme autre que le papier est autorisée, ce qui est souvent utilisé récemment, en incluant la forme graphique ou électronique du manuel Lennox International Inc. XP1906 ou les vidéos d'instruction pour les utilisateurs. La condition est son caractère lisible et compréhensible.
Qu'est ce que le manuel d’utilisation?
Le mot vient du latin "Instructio", à savoir organiser. Ainsi, le manuel d’utilisation Lennox International Inc. XP1906 décrit les étapes de la procédure. Le but du manuel d’utilisation est d’instruire, de faciliter le démarrage, l'utilisation de l'équipement ou l'exécution des actions spécifiques. Le manuel d’utilisation est une collection d'informations sur l'objet/service, une indice.
Malheureusement, peu d'utilisateurs prennent le temps de lire le manuel d’utilisation, et un bon manuel permet non seulement d’apprendre à connaître un certain nombre de fonctionnalités supplémentaires du dispositif acheté, mais aussi éviter la majorité des défaillances.
Donc, ce qui devrait contenir le manuel parfait?
Tout d'abord, le manuel d’utilisation Lennox International Inc. XP1906 devrait contenir:
- informations sur les caractéristiques techniques du dispositif Lennox International Inc. XP1906
- nom du fabricant et année de fabrication Lennox International Inc. XP1906
- instructions d'utilisation, de réglage et d’entretien de l'équipement Lennox International Inc. XP1906
- signes de sécurité et attestations confirmant la conformité avec les normes pertinentes
Pourquoi nous ne lisons pas les manuels d’utilisation?
Habituellement, cela est dû au manque de temps et de certitude quant à la fonctionnalité spécifique de l'équipement acheté. Malheureusement, la connexion et le démarrage Lennox International Inc. XP1906 ne suffisent pas. Le manuel d’utilisation contient un certain nombre de lignes directrices concernant les fonctionnalités spécifiques, la sécurité, les méthodes d'entretien (même les moyens qui doivent être utilisés), les défauts possibles Lennox International Inc. XP1906 et les moyens de résoudre des problèmes communs lors de l'utilisation. Enfin, le manuel contient les coordonnées du service Lennox International Inc. en l'absence de l'efficacité des solutions proposées. Actuellement, les manuels d’utilisation sous la forme d'animations intéressantes et de vidéos pédagogiques qui sont meilleurs que la brochure, sont très populaires. Ce type de manuel permet à l'utilisateur de voir toute la vidéo d'instruction sans sauter les spécifications et les descriptions techniques compliquées Lennox International Inc. XP1906, comme c’est le cas pour la version papier.
Pourquoi lire le manuel d’utilisation?
Tout d'abord, il contient la réponse sur la structure, les possibilités du dispositif Lennox International Inc. XP1906, l'utilisation de divers accessoires et une gamme d'informations pour profiter pleinement de toutes les fonctionnalités et commodités.
Après un achat réussi de l’équipement/dispositif, prenez un moment pour vous familiariser avec toutes les parties du manuel d'utilisation Lennox International Inc. XP1906. À l'heure actuelle, ils sont soigneusement préparés et traduits pour qu'ils soient non seulement compréhensibles pour les utilisateurs, mais pour qu’ils remplissent leur fonction de base de l'information et d’aide.
Table des matières du manuel d’utilisation
-
Page 1
09/12 506920−01 *2P0912* *P506920-01* 2012 Lennox Industries Inc. Dallas, T exas, USA indoor temperature indoor humidity is 41% fan is OFF fan is AUTO cool−to set temp 75 heat to 72 heat or cool fan is AUTO away mode outdoor temperature 80 system is cooling 9:39 am Aug 15, 2012 Wi−Fi THIS MANUAL MUST BE LEFT WITH THE HOMEOWNER FOR FUTURE [...]
-
Page 2
506920−01 09/12 Page 2 T able of Content s Page T echnical Description/Features 3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Installation and Setup 4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . System Settings screen 4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [...]
-
Page 3
icomfort Wi-Fi 7−Day Programmable Communicating Thermostat Page 3 icomfort Wi-Fi Thermost at − T echnical Description and Features The 24V AC icomfort Wi-Fi thermostat (figure 1) is an electronic communi- cating, color display touchscreen, 7−day programmable thermostat. It stores system parameters and settings in nonvolatile memor[...]
-
Page 4
506920−01 09/12 Page 4 Inst allation and Setup IMPOR T ANT! Make sure the router is capable of, and set to operate in wireless network b" mode. Check router utility program or contact service provider for help. When determining the location for the Wi−Fi ther- mostat, be sure it is in an area near enough to the homeowner’s Wi−Fi rou[...]
-
Page 5
icomfort Wi-Fi 7−Day Programmable Communicating Thermostat Page 5 Circulate Fan ON Time Range is 15 to 50 % Default is 35, inc: 1 cancel save set−to 45% up/down arrows radio buttons Not Installed 1 S tage A/C Unit 2 S tage A/C Unit 1 S tage HP Unit 2 S tage HP Unit Select one Out door Unit T ype cancel save Dealer Name keyboard tool Figure [...]
-
Page 6
506920−01 09/12 Page 6 Circulate fan ON time setting NOTE − If the circulate fan mode is on, a timer is set to measure all the time that the fan is blowing, regardless if it is running to deliver heating or cooling or just for circulation. Circulate" is enabled on the user’s home screen or system settings page. It keeps air circulatin[...]
-
Page 7
icomfort Wi-Fi 7−Day Programmable Communicating Thermostat Page 7 Set time and date Us e the arrows to select Time and Date; press edit (see figure 5 ) to proceed to the Set current time and date" screen (figure 6). system settings T o adjust a setting, highlight it, then press Edit 9:39 am Aug 15, 2012 edit next back current value: 9[...]
-
Page 8
506920−01 09/12 Page 8 Use about" screen & access Add or Remove Non−communicating equipment" screen The about" screen shows details of discovered installed equipment. From the system devices" screen, use arrow buttons to scroll to a device; then press the about button. Use the up/down arrows to scroll through[...]
-
Page 9
icomfort Wi-Fi 7−Day Programmable Communicating Thermostat Page 9 Add or Remove Non−communicating equipment Figure 7 (previous page) shows how to access the Add or Remove Non− communicating equipment" screen. Adding Non−Communicating O ut door unit See figure 8 for details for adding/removing an outdoor unit. Adding Humidifi[...]
-
Page 10
506920−01 09/12 Page 10 Add Non−Communicating Outdoor unit System Devices Add or Remove Non−communicating equipment? yes next back 1 non−communicating device list Not Installed current value: back edit Not Installed 1 S tage A/C Unit 2 S tage A/C Unit 1 S tage HP Unit 2 S tage HP Unit Select one Out door Unit T ype cancel save T o add (or r[...]
-
Page 11
icomfort Wi-Fi 7−Day Programmable Communicating Thermostat Page 1 1 Add (or Remove) Humidifier (skip if no humidifier is being used) NOTE − Adding humidity regulating non−communicating devices may be a 2−step procedure : 1st , the device must be installed (this page; af ter the humidifier is installed, the operation mode defaults to [...]
-
Page 12
506920−01 09/12 Page 12 Add (or Remove) Humiditrol ® or Auxiliary Dehumidifier (skip if no dehumidifying device is being used) Before adding a dehumidifier, be sure that: the dehumidifier is wired to the furnace or air handler control as shown on the Option- al Accessories wiring diagram (see Page 61), the entire system is wired, powered[...]
-
Page 13
icomfort Wi-Fi 7−Day Programmable Communicating Thermostat Page 13 Adjust a setting screen (communicating devices) Use arrows to select a device from the system devices" list; then use the about button to view information (shown on Page 8) about communicating devices (information about other devices is not available). Use resetAll but[...]
-
Page 14
506920−01 09/12 Page 14 Use the up/down arrows to scroll through the device’s settings. The current setting will be displayed on the right−hand side of the screen (figure 12). For example, current value: disabled . Press edit if you want to modify that setting, or press back to return to the previous screen. A vailable settings for the device[...]
-
Page 15
icomfort Wi-Fi 7−Day Programmable Communicating Thermostat Page 15 Adjust a setting... Configure Humidifier (skip if no humidifier is being used or if humidifier is being used and default Basic" humidification mode is desired) System Devices edit about T o adjust a setting, highlight it, then press Edit System resetAll next back 1a 1b[...]
-
Page 16
506920−01 09/12 Page 16 Adjust a setting... Configure Humiditrol ® or Auxiliary Dehumidifier edit about T o adjust a setting, highlight it, then press Edit System reinst all edit reset Dehumidification Control Mode current value: back Midpoint Overcooling Pre−adjustment REQUIREMENTS: 1st , the device has been installed (see Page 12). 2nd , fro[...]
-
Page 17
icomfort Wi-Fi 7−Day Programmable Communicating Thermostat Page 17 Adjust a setting... Configure Dehumidification (no dehumidifying device installed) (skip if default Basic" dehumidification mode is desired) edit about T o adjust a setting, highlight it, then press Edit reinst all next back edit reset Dehumidification Control Mode cur[...]
-
Page 18
506920−01 09/12 Page 18 Humidification and Dehumidification Modeshow they work HUMIDIFICA TION modes BASIC & PRECISION These modes allow user control of RH between 15 and 45%. These conditions must be met for either mode to operate: humidification mode has been enabled, and the unit is in HEA T mode, and humidification deman[...]
-
Page 19
icomfort Wi-Fi 7−Day Programmable Communicating Thermostat Page 19 Use the T ests / Diagnostics features NOTE − T est mode lasts for 30 minutes (with the temperature updating every 30 seconds) except for the defrost test, which lasts 30 seconds. T ests fea- ture provides the technician time to manually verify the equipment operation. The te[...]
-
Page 20
506920−01 09/12 Page 20 After pressing next after the final test, the T esting finished" screen will ap- pear (figure 20). At this point, use the EXIT button (if you have completed the required setup), or use diagnostics button (to analyze the system), or use equipment button (if you wish to make any changes to device details). 9:39 am Au[...]
-
Page 21
icomfort Wi-Fi 7−Day Programmable Communicating Thermostat Page 21 9:39 am Aug 15, 2012 system devices equipment test s setup edit back resetAll current value: 400 Low Heating Airflow Equipment Name Heating Airflow Control Type Low Heating Airflow High Heating Airflow High Cooling Airflow Airflow Profile − Cooling High HP Airflow Continuous[...]
-
Page 22
506920−01 09/12 Page 22 Press done when finished with the information. Select another device to diagnose or use EXIT (to close and go to user Home screen) if finished. 9:39 am Aug 15, 2012 select a device: current selection: Furnace st art EXIT equipment diagnostics test s alerts setup Heat Pump Furnace DIAGNOSTICS Furnace 9:39 am Aug 15, 2012 He[...]
-
Page 23
icomfort Wi-Fi 7−Day Programmable Communicating Thermostat Page 23 System Devices equipment diagnostics test s alerts setup System Furnace Thermostat system and device alerts 9:39 am Aug 15, 2012 EXIT view active deselect all select all view cleared alert description equipment test s setup active alerts 9:39 am Aug 15, 2012 back ALERT 1 of 5 [...]
-
Page 24
506920−01 09/12 Page 24 Enable the thermostat’s Wi-Fi feature from the Home screen press any line to edit it connect password security is WP A2 network name (SSID) type the network security key or passphrase for (locked Wi−Fi Access Point [AP]) network security key or passphrase press here to enter network name press here to enter Wi−Fi AP [...]
-
Page 25
icomfort Wi-Fi 7−Day Programmable Communicating Thermostat Page 25 Registering the icomfort Wi-Fi thermostat From NETWORK SETTINGS screen, you can change to the desired net- work as s ho w n i n f i gure 28. Enter security key or passphrase. X" back to the WI−FI SETTINGS screen. choose a wireless network add new network NETWKB N[...]
-
Page 26
506920−01 09/12 Page 26 Personal Computer account registration for icomfort Wi-Fi server NOTE − This following information is customer setup in- structions and is shown here to allow the inst aller to help walk the customer through the setup process. After reg ist er ing through your icomfort Wi-Fi thermostat i n- terface, go to the hom[...]
-
Page 27
icomfort Wi-Fi 7−Day Programmable Communicating Thermostat Page 27 Personal Computer W elcome p age; Interactive Demo; Online icomfort information; Using Gelaskins Figure 31. PC Welcome Screen Welcome home. Access all the great Wi−Fi enabled features on your icomfort ® thermostat from our secure web portal. After signing in, you´ll be abl[...]
-
Page 28
506920−01 09/12 Page 28 Access inst aller program from Home screen T o access the installer program after the unit has been placed in operation an d the user home screen is displayed, press the Lennox" logo and hold for 5 seconds (see figure 32). The system will access the installer screens. indoor temperature indoor humidity is 41% fan i[...]
-
Page 29
icomfort Wi-Fi 7−Day Programmable Communicating Thermostat Page 29 Reconfigure a system If any component of the HV AC system has been changed, e.g. replacing an outdoor sensor , reconfiguring the system will be required. T o begin reconfi- guring a system (after you have accessed the program from the Lennox logo [previous page]), press the se[...]
-
Page 30
506920−01 09/12 Page 30 S t age Delay & Differential Settings (Installer settings) 1st S t age Differential1 Stage 1 dif ferential is used in all thermostats. T he default is 1.0°F but can be programmed between 0.5° and 3.0°F in 0.5°F in- crements. From the equipment button, use the arrows to select 1st Stage Dif ferential. Press edit [...]
-
Page 31
icomfort Wi-Fi 7−Day Programmable Communicating Thermostat Page 31 Smooth Setback Recovery (SSR) SSR is an algorithm designed to smoothly" reach a occupied program schedule setpoint. The algorithm looks 2 hours ahead for the occupied pro- gram schedule period’s setpoint. If the occupied setpoint requires the sys- tem to turn on (pre[...]
-
Page 32
506920−01 09/12 Page 32 Heat Pump, Dual Fuel and Balance Point s IMPOR T ANT − The Balance Points feature requires that a sensed out- door temperature is provided to the thermostat. This can be either a connection to Wi−Fi (for local temperature information) or a connection to an outdoor sensor (included in all communicating icomfort t −en-[...]
-
Page 33
icomfort Wi-Fi 7−Day Programmable Communicating Thermostat Page 33 Abbreviations: FURN = auxiliary heat provided by gas furnace HP = compressor heat LBP = Low Balance Point HBP = High Balance Point T’stat = thermostat Shut down FURN S tg1...S tg 2 Operate HP S tg 1...S tg 2 at or below LBP FURN heat lockout HP stage(s) operate first; then F[...]
-
Page 34
506920−01 09/12 Page 34 Gas Heat Control Mode NO NO YES YES YES NO NO YES YES NO NO YES YES NO YES NO Continue at starting firing rate T’stat demand satisfied ? Starting firing rate as determined by variable capacity algorithm (35 to 100%) Differential less than 2nd stage differential ? T’stat demand satisfied ? T’stat demand satisfied ? Fi[...]
-
Page 35
icomfort Wi-Fi 7−Day Programmable Communicating Thermostat Page 35 V ariable Cap acity Control of Gas Heat Mode (G71MPP and SLP98V) The thermostat includes a feature that provides variable capacity control of the gas heat mode. The purpose of variable capacity control is to keep the room temperature at, or near , the desired setpoint with min[...]
-
Page 36
506920−01 09/12 Page 36 Load−tracking V ariable Cap acity F AQs (SLP98V only) What is Load−tracking V ariable Cap acity? When an SLP98 Furnace is connected t o an icomfort Wi−Fi thermostat , the thermostat takes complete charge of the variable capacity staging of the furnace. Load − tracking V ari- able Capacity is only available with[...]
-
Page 37
icomfort Wi-Fi 7−Day Programmable Communicating Thermostat Page 37 T able 3. Adjust able Parameters T able (Inst aller) Parameter Name: Default Parameter V alue Setting Increment Inst aller entry System (Go to equipment button and scroll to System) NOTE − All of the following changes are made on the stat. Equipment Name (keyboard input [...]
-
Page 38
506920−01 09/12 Page 38 T able 3 . Adjust able Parameters T able (Inst aller) Parameter Name: Installer entry Increment Parameter V alue Setting Default Lock in 2nd stage HP by Outdoor T emp Off Of f, 40ºF (4ºC), 45ºF (7ºC), 50ºF (10ºC), 55ºF (13ºC) Balance Point Control Disabled Enabled, Disabled Humiditrol Comfort Adjust Maximum[...]
-
Page 39
icomfort Wi-Fi 7−Day Programmable Communicating Thermostat Page 39 T able 3 . Adjust able Parameters T able (Inst aller) Parameter Name: Installer entry Increment Parameter V alue Setting Default AIR HANDLER Equipment Name Air Handler (keyboard input screen) Electric Heating Airflow nnnn CFM (See Note 3 at end of table) NOTE: CFM Default [...]
-
Page 40
506920−01 09/12 Page 40 T able 3 . Adjust able Parameters T able (Inst aller) Parameter Name Default Min. Max. Incr . Dependency Note Inst aller entry FURNACE Heating indoor blower OFF delay DIP SW 60 180 10 None DIP switch setting in Non−comm. Heating indoor blower ON delay 45 sec 15 45 5 None 45 sec fixed in Non− Comm. IFC Cooling indoor bl[...]
-
Page 41
icomfort Wi-Fi 7−Day Programmable Communicating Thermostat Page 41 T able 3 . Adjust able Parameters T able (Inst aller) Parameter Name Installer entry Note Dependency Incr . Max. Min. Default Cooling Airflow Settings High Cooling Airflow (CFM @ 100% cool) OU tons 400CFM Min CFM Max CFM 25 Outdoor Unit present 1/2 HP blower Min CFM Max CFM 25[...]
-
Page 42
506920−01 09/12 Page 42 T able 3 . Adjust able Parameters T able (Inst aller) Parameter Name Installer entry Note Dependency Incr . Max. Min. Default Other Parameters Equipment Name Furnace N/A N/A N/A None Up to 35 characters Continuous Indoor Blower Airflow DIP SW (See Note 3 at end of table) Min CFM Max CFM 25 None 1/2 HP blower Min CFM Max CF[...]
-
Page 43
icomfort Wi-Fi 7−Day Programmable Communicating Thermostat Page 43 T able 4. Adjust able Parameters T able (User) Parameter Name: Default Parameter V alue Setting Increment Inst aller entry Time and Date * (Time/date elements screen) Daylight Saving Time * Enabled Enabled, Disabled Fan auto auto, on, circulate System Name [...]
-
Page 44
506920−01 09/12 Page 44 T able 4 . Adjust able Parameters T able (User) Parameter Name: Installer entry Increment Parameter V alue Setting Default Filter 1 T imer Disabled Disabled, 3 Months, 6 Months, 12 Months, 24 Months, Custom Time Filter 1 Timer Disabled Disabled, 3 Months, 6 Months, 12 Months, 24 Months, Custom Time Humidifier Pad T[...]
-
Page 45
icomfort Wi-Fi 7−Day Programmable Communicating Thermostat Page 45 T able 5. Alert Codes and T roubleshooting Critical alerts are displayed on Home (user) screen, in the Homeowner alert button, and in the Installer alert button. Minor and Moderate alerts are found only in the Installer alert button. Alert Code Priority Alert T ext Step s to c[...]
-
Page 46
506920−01 09/12 Page 46 Critical alerts are displayed on Home (user) screen, in the Homeowner alert button, and in the Installer alert button. Minor and Moderate alerts are found only in the Installer alert button. T able 5 . A lert Codes and T roubleshooting Alert Code Step s to clear Alert T ext Priority 34 Critical (Stat) The thermostat does n[...]
-
Page 47
icomfort Wi-Fi 7−Day Programmable Communicating Thermostat Page 47 Critical alerts are displayed on Home (user) screen, in the Homeowner alert button, and in the Installer alert button. Minor and Moderate alerts are found only in the Installer alert button. T able 5 . A lert Codes and T roubleshooting Alert Code Step s to clear Alert T ext Pr[...]
-
Page 48
506920−01 09/12 Page 48 Critical alerts are displayed on Home (user) screen, in the Homeowner alert button, and in the Installer alert button. Minor and Moderate alerts are found only in the Installer alert button. T able 5 . A lert Codes and T roubleshooting Alert Code Step s to clear Alert T ext Priority 180 Critical (Furnace / Air Handler / Ou[...]
-
Page 49
icomfort Wi-Fi 7−Day Programmable Communicating Thermostat Page 49 Critical alerts are displayed on Home (user) screen, in the Homeowner alert button, and in the Installer alert button. Minor and Moderate alerts are found only in the Installer alert button. T able 5 . A lert Codes and T roubleshooting Alert Code Step s to clear Alert T ext Pr[...]
-
Page 50
506920−01 09/12 Page 50 Critical alerts are displayed on Home (user) screen, in the Homeowner alert button, and in the Installer alert button. Minor and Moderate alerts are found only in the Installer alert button. T able 5 . A lert Codes and T roubleshooting Alert Code Step s to clear Alert T ext Priority 275 Critical (Furnace) The furnace flame[...]
-
Page 51
icomfort Wi-Fi 7−Day Programmable Communicating Thermostat Page 51 Critical alerts are displayed on Home (user) screen, in the Homeowner alert button, and in the Installer alert button. Minor and Moderate alerts are found only in the Installer alert button. T able 5 . A lert Codes and T roubleshooting Alert Code Step s to clear Alert T ext Pr[...]
-
Page 52
506920−01 09/12 Page 52 Critical alerts are displayed on Home (user) screen, in the Homeowner alert button, and in the Installer alert button. Minor and Moderate alerts are found only in the Installer alert button. T able 5 . A lert Codes and T roubleshooting Alert Code Step s to clear Alert T ext Priority 354 Critical (Air Handler) There is a pr[...]
-
Page 53
icomfort Wi-Fi 7−Day Programmable Communicating Thermostat Page 53 Critical alerts are displayed on Home (user) screen, in the Homeowner alert button, and in the Installer alert button. Minor and Moderate alerts are found only in the Installer alert button. T able 5 . A lert Codes and T roubleshooting Alert Code Step s to clear Alert T ext Pr[...]
-
Page 54
506920−01 09/12 Page 54 Critical alerts are displayed on Home (user) screen, in the Homeowner alert button, and in the Installer alert button. Minor and Moderate alerts are found only in the Installer alert button. T able 5 . A lert Codes and T roubleshooting Alert Code Step s to clear Alert T ext Priority 418 Moderate (Outdoor Unit) There is a f[...]
-
Page 55
icomfort Wi-Fi 7−Day Programmable Communicating Thermostat Page 55 T able 6. T roubleshooting Tip s Bold text indicates a button, or text display on the thermostat. No. Issue / Problem Possible Cause Corrective Action / Comments 1 − No electric heat operation. − The thermostat system setting does not offer a emerg. heat choice on an HP sy[...]
-
Page 56
506920−01 09/12 Page 56 Bold text indicates a button, or text display on the thermostat. T able 6. T roubleshooting T ips No. Corrective Action / Comments Possible Cause Issue / Problem 6 High Balance Point and Low Bal- ance Point are not listed as a menu item to adjust the setpoint on the ther- mostat of the heat pump system. Balance Point Contr[...]
-
Page 57
icomfort Wi-Fi 7−Day Programmable Communicating Thermostat Page 57 Bold text indicates a button, or text display on the thermostat. T able 6. T roubleshooting T ips No. Corrective Action / Comments Possible Cause Issue / Problem 12 Determine the actual Software ver- sion of the thermostat or one of the icomfort unit controls. icomfort softwar[...]
-
Page 58
506920−01 09/12 Page 58 Bold text indicates a button, or text display on the thermostat. T able 6. T roubleshooting T ips No. Corrective Action / Comments Possible Cause Issue / Problem 18 During the cooling mode the dis- played air volume on the indoor con- trol is substantially lower than ex- pected. The system may be following the cooling r[...]
-
Page 59
icomfort Wi-Fi 7−Day Programmable Communicating Thermostat Page 59 Wiring Diagrams icomfort Communicating System Wiring icomfort by Lennox FURNACE (IFC) OR AIR HANDLER (AHC) icomfort Wi-Fi THERMOST A T icomfort by Lennox OUTDOOR AIR CON- DITIONING OR HEA T PUMP UNIT OPTIONAL OUT- DOOR AIR SENSOR (SEE OAS NOTE) OPTIONAL DIS- CH[...]
-
Page 60
506920−01 09/12 Page 60 Wiring Diagrams icomfort Communicating Indoor/non−Communicating Outdoor System Wiring icomfort Wi-Fi Thermostat icomfort by Lennox Air Handler S tandard Outdoor Heat Pump ST ANDARD OUTDOOR HEA T PUMP UNIT − 1 OR 2 ST AGE icomfort by Lennox AIR HANDLER (AHC) icomfort Wi-Fi THERMOST A T icomfort by Le[...]
-
Page 61
icomfort Wi-Fi 7−Day Programmable Communicating Thermostat Page 61 Optional Accessories Wiring for use with any icomfort by Lennox system icomfort by Lennox SLP98 & G71MPP FURNACE (IFC) OR AIR HANDLER (AHC) icomfort Wi-Fi THERMOST A T DISCHARGE AIR SEN- SOR (REQUIRED FOR EVEN HEA T) (SEE DAS NOTE Page 59) NOTE: icomfort Wi-Fi [...]
-
Page 62
506920−01 09/12 Page 62 Optional Accessories Wiring for use with any icomfort by Lennox system icomfort Wi-Fi Thermostat RSBus L VCS V entilation Control System icomfort by Lennox Furnace or Air Handler HEP A Bypass Filter X2680 HEP A Interlock Kit Pass indoor blower motor common wire through cur- rent loop. See HEP A In- terlock Kit [...]
-
Page 63
icomfort Wi-Fi 7−Day Programmable Communicating Thermostat Page 63 Thermost at wire te rmination in communicating system Indoor Unit Controller Outdoor Unit icomfort Wi-Fi thermostat Single wire to terminal C Single wire to terminal C Unused wires Unused wires Communicating systems using the icomfort Wi-Fi thermostat requ ire four the[...]
-
Page 64
506920−01 09/12 Page 64 Configuring heat strip s on Air Handler Control (AHC) IMPORT ANT : Af ter electric heat strips are installed, the Air Handler Control (AHC) must be manually configured to detect the number of electric heat sections. (SEE ALSO 506181−01 for complete configuration guide.) T o configure the heat strips so that they will be [...]
-
Page 65
icomfort Wi-Fi 7−Day Programmable Communicating Thermostat Page 65 Setting up typical systemsFURNACE & AIR CONDITIONING UNIT icomfort −enabled furnace & icomfort −enabled air conditioner An icomfort−enabled gas furnace (G71MPP , EL296V , SLP98, SL280) with an icomfort−enabled AC (XC17 or XC21 only) unit. 1. Wiring ?[...]
-
Page 66
506920−01 09/12 Page 66 icomfort −enabled furnace & non−communicating air conditioner An icomfort−enabled gas furnace (G71MPP , EL296V , SLP98, SL280) with a conventional non−communicating air conditioner . 1. Wiring See Communicating Indoor/Non−Communicating Out- door System Wiring diagram on Page 59 and Optional Accessories[...]
-
Page 67
icomfort Wi-Fi 7−Day Programmable Communicating Thermostat Page 67 Setting up typical system sFURNACE & HEA T PUMP (DUAL FUEL) icomfort −enabled Furnace & icomfort −enabled HP unit (Dual fuel) Dual fuel system using an icomfort−enabled gas furnace (G71MPP , EL296V , SLP98, SL280) with an icomfort−enabled heat pump ([...]
-
Page 68
506920−01 09/12 Page 68 Setting up typical systemsAIR HANDLER & AIR CONDITIONER icomfort −enabled Air Handler & icomfort −enabled Air Conditioner An icomfort−enabled air handler (CBX32MV or CBX40UHV) with an icom- fort−enabled air conditioner (XC17 or XC21 only). NOTE − IMPORT ANT! Be sure to configure the air handler[...]
-
Page 69
icomfort Wi-Fi 7−Day Programmable Communicating Thermostat Page 69 icomfort enabled Air Handler & conventional non−communicating Air Conditioner An icomfort air handler (CBX32MV or CBX40UHV) with a conventional non− communicating AC unit. NOTE − IMPOR TANT! Be sure to set up the air handler control for heat strips (if used) prio[...]
-
Page 70
506920−01 09/12 Page 70 Setting up typical systemsAIR HANDLER & HEA T PUMP UNITS icomfort −enabled Air Handler & icomfort −enabled Heat Pump unit An icomfort air handler (CBX32MV or CBX40UHV) with an icomfort−enabled heat pump (XP17 or XP21 only) unit. NOTE − IMPOR TANT! Be sure to set up the air handler control for hea[...]
-
Page 71
icomfort Wi-Fi 7−Day Programmable Communicating Thermostat Page 71 icomfort −enabled Air Handler & conventional non−communicating Heat Pump unit An icomfort air handler (CBX32MV or CBX40UHV) with a conventional non− communicating heat pump unit. NOTE − IMPOR TANT! Be sure to set up the air handler control for heat strips (if u[...]
-
Page 72
506920−01 09/12 Page 72 T able 7. Replacement Controls The following kits have been set up for replacement of the icomfort −enabled controls. Please note that control kits are unit− and revision−specific. icomfort −Enabled Unit Replacement Kit Cat alog No. Control Part No. G71MPP (rev . 03 or later) 65W69 605341−01 SLP98 (rev . [...]