State Industries SHE 50 76N manuel d'utilisation
- Voir en ligne ou télécharger le manuel d’utilisation
- 40 pages
- 3.72 mb
Aller à la page of
Les manuels d’utilisation similaires
-
Water Heater
State Industries SBD71 120
56 pages 4.27 mb -
Water Heater
State Industries PR6 10 10MS
4 pages 0.09 mb -
Water Heater
State Industries SBN85390NE/A
32 pages 0.51 mb -
Water Heater
State Industries SHE 50 76N
40 pages 3.72 mb -
Water Heater
State Industries Residential Electric Water Heaters
2 pages 1.58 mb -
Water Heater
State Industries TPG-600-2500
16 pages 0.22 mb -
Water Heater
State Industries GS6 40 YBRT Series 200
36 pages 2.26 mb -
Water Heater
State Industries PR6 40/50 XCVIT, CCVIT 200, CCVIT 201, PR6 40/50 XCVIT 2, CCVIT 2
4 pages 0.06 mb
Un bon manuel d’utilisation
Les règles imposent au revendeur l'obligation de fournir à l'acheteur, avec des marchandises, le manuel d’utilisation State Industries SHE 50 76N. Le manque du manuel d’utilisation ou les informations incorrectes fournies au consommateur sont à la base d'une plainte pour non-conformité du dispositif avec le contrat. Conformément à la loi, l’inclusion du manuel d’utilisation sous une forme autre que le papier est autorisée, ce qui est souvent utilisé récemment, en incluant la forme graphique ou électronique du manuel State Industries SHE 50 76N ou les vidéos d'instruction pour les utilisateurs. La condition est son caractère lisible et compréhensible.
Qu'est ce que le manuel d’utilisation?
Le mot vient du latin "Instructio", à savoir organiser. Ainsi, le manuel d’utilisation State Industries SHE 50 76N décrit les étapes de la procédure. Le but du manuel d’utilisation est d’instruire, de faciliter le démarrage, l'utilisation de l'équipement ou l'exécution des actions spécifiques. Le manuel d’utilisation est une collection d'informations sur l'objet/service, une indice.
Malheureusement, peu d'utilisateurs prennent le temps de lire le manuel d’utilisation, et un bon manuel permet non seulement d’apprendre à connaître un certain nombre de fonctionnalités supplémentaires du dispositif acheté, mais aussi éviter la majorité des défaillances.
Donc, ce qui devrait contenir le manuel parfait?
Tout d'abord, le manuel d’utilisation State Industries SHE 50 76N devrait contenir:
- informations sur les caractéristiques techniques du dispositif State Industries SHE 50 76N
- nom du fabricant et année de fabrication State Industries SHE 50 76N
- instructions d'utilisation, de réglage et d’entretien de l'équipement State Industries SHE 50 76N
- signes de sécurité et attestations confirmant la conformité avec les normes pertinentes
Pourquoi nous ne lisons pas les manuels d’utilisation?
Habituellement, cela est dû au manque de temps et de certitude quant à la fonctionnalité spécifique de l'équipement acheté. Malheureusement, la connexion et le démarrage State Industries SHE 50 76N ne suffisent pas. Le manuel d’utilisation contient un certain nombre de lignes directrices concernant les fonctionnalités spécifiques, la sécurité, les méthodes d'entretien (même les moyens qui doivent être utilisés), les défauts possibles State Industries SHE 50 76N et les moyens de résoudre des problèmes communs lors de l'utilisation. Enfin, le manuel contient les coordonnées du service State Industries en l'absence de l'efficacité des solutions proposées. Actuellement, les manuels d’utilisation sous la forme d'animations intéressantes et de vidéos pédagogiques qui sont meilleurs que la brochure, sont très populaires. Ce type de manuel permet à l'utilisateur de voir toute la vidéo d'instruction sans sauter les spécifications et les descriptions techniques compliquées State Industries SHE 50 76N, comme c’est le cas pour la version papier.
Pourquoi lire le manuel d’utilisation?
Tout d'abord, il contient la réponse sur la structure, les possibilités du dispositif State Industries SHE 50 76N, l'utilisation de divers accessoires et une gamme d'informations pour profiter pleinement de toutes les fonctionnalités et commodités.
Après un achat réussi de l’équipement/dispositif, prenez un moment pour vous familiariser avec toutes les parties du manuel d'utilisation State Industries SHE 50 76N. À l'heure actuelle, ils sont soigneusement préparés et traduits pour qu'ils soient non seulement compréhensibles pour les utilisateurs, mais pour qu’ils remplissent leur fonction de base de l'information et d’aide.
Table des matières du manuel d’utilisation
-
Page 1
1 Instruction Manual PRINTED 0810 197421-003 KEEP THIS MANUAL IN THE POCKET ON HEA TER FOR FUTURE REFERENCE WHENEVER MAINTENANCE ADJUSTMENT OR SERVICE IS REQUIRED. POWER VENTED GAS MODELS W/HOT SURF ACE IGNITION MODEL SHE 50 76N SERIES 1 00 ALL TECHNICAL AND W ARRANTY QUESTIONS: SHOULD BE DIRECTED T O THE LOCAL DEALER FROM WHOM THE W A TER HEA TER [...]
-
Page 2
2 SAFE INST ALLA TION, USE AND SERVICE The proper installation, use and servicing of this water heater is extremely important to your safety and the safety of others. Many safety-related messages and instructions have been provided in this manual and on your own water heater to warn you and others of a potential injury hazard. Read and obey all saf[...]
-
Page 3
3 GENERAL SAFETY INFORMA TION[...]
-
Page 4
4 GENERAL SAFETY INFORMA TION at le as t 1 8" (4 5. 7 cm ) ab ov e the f loo r. This will reduce, but not eliminate, the ri sk[...]
-
Page 5
5 Thank Y ou for purchasing this water heater . Properly installed and maintained, it should give you years of trouble free service. Abbreviations Found In This Instruction Manual: • CSA -CanadianStandards Association • ANSI- AmericanNationalStandardsInstitute • NFP A -NationalFireProtection [...]
-
Page 6
6 INST ALLA TION REQUIREMENTS FOR THE COMMONWEAL TH OF MASSACHUSETTS COMMONWEAL TH OF MASSACHUSETTS For all side wall terminated, horizontally vented power vent, direct vent, and power direct vent gas fueled water heaters installed in every dwelling, building or structure used in whole or in part for residential purposes, including those owned or o[...]
-
Page 7
7 TYPICAL INST ALLA TION * CAUTION HARNESS HAS 120 VAC. IN OPERATION. ** See “PLANNING THE VENT SYSTEM”, “CONDENSA TE” and “BLOWER ASSEMBL Y INST ALLA TION” for more information. *** The side recirculation loop connections may not be used as the primary water inlet and outlet connections. For your convenience, plugs are installed in the[...]
-
Page 8
8 TYPICAL INST ALLA TION CONDENSA TE HOSE AND DRAIN P AN FIGURE 1 (continued).[...]
-
Page 9
9 TYPICAL INST ALLA TION MIXING V AL VES DA NGER Wa ter temperatur e over 125° F (52° C) c an cause severe burns instantl y resulting in severe injury or death. Children, the elderly and the physically or mentally disabled are at highest risk for scald injury . Fe el water be fo re ba t hing or showering . Te mperature limiting devices such as mi[...]
-
Page 10
10 ROUGH-IN-DIMENSIONS Rough-In-Dimensions T op/SideInletandOutlet:3/4”NPT GasInlet:1/2”NPT Capacity and Gas and Electrical Characteristics Allmodels-MaximumSupplyPressure:14inchesW .C.(3.48kPa) MinimumSupplyPressureNaturalGas:5.0inchesW .C.(1.24kPa) MinimumPressure?[...]
-
Page 11
11 F ACTS TO CONSIDER ABOUT THE LOCA TION Carefully choose an indoor location for the new water heater , because the placement is a very important consideration for the safety of the occupants in the building and for the most economical use of the appliance. This water heater is not for use in manufactured (mobile) homes or outdoor installation. Wh[...]
-
Page 12
12 in an alcove or closet, the entire oor must be covered by the panel. Failuretoheedthiswarningmayresultinarehazard. Minimum clearances between water heater and combustible construction are 0 inch at the sides and rear , 5.5” (14.0 cm)?[...]
-
Page 13
13 Such a condition often will result in a yellow , luminous burner flame, causing sooting of the combustion chamber , burners and flue tubes and creates a risk of asphyxiation. Do not install the water heater in a conned space unless an adequate supply of air for combustion and ventilation is brought in to[...]
-
Page 14
14 Figure 7. The water heater shall have clearances of at least 1 inch (25 mm) from the sides and back and 6 inches (150 mm) from the front of the appliance. The opening shall directly communicate with the outdoors or shall communicate through a vertical or horizontal duct to the outdoors or spaces that fre[...]
-
Page 15
15 Thi s water heat er shou ld not b e con nec ted to any he ating sys tems or co mpo nent(s )u sedwi thano n- pot abl ewaterhe atinga ppli anc e. Al l pipin g co mpo nents c onn ec ted to thi s unit fo r spac e heat ing app lic atio ns sho uld be s uita ble fo r use w ith po tabl e water . T oxic c hemi ca ls, suc h as th ose [...]
-
Page 16
16 THERMAL EXP ANSION As water is heated,it expands (thermal expansion). In a closed system the volume of water will grow when it is heated. As the volume of water grows there will be a corresponding increase in water pressure due to thermal expansion. Thermal expansion can cause premature tank failure (leakag[...]
-
Page 17
17 discharge opening must not be blocked or reduced in size under any circumstances. Excessive length, over 30 feet (9.14 m), or use of more than four elbows can cause restriction and reduce the discharge capacity of the valve. No valve or other obstruction is to be placed between the T emperature-Pressure Relief V al[...]
-
Page 18
18 A gas line of sufcient size must be run tothe water heater . Consult thecurrentedition ofNationalFuel GasCode(ANSI Z223.1/NFP A 54) or the Natural Gas and Propane Installation Code (CAN/CSA B149.1)andyourgassupplierconcer[...]
-
Page 19
19 Never use t his wate r heater u nles s it is c omp letely f ull of wate r . T o prevent d amage to t he t ank, t he t ank m ust be ll ed w ith wate r . Wate r must ow fr om the hot water fau cet b efore t urn ing “O N ” gas to t he water heater. T oll?[...]
-
Page 20
20 TERMINA TION CLEARANCES SIDEW ALL POWER VENT V X VEN T TERMINAL AIR SUPPL Y INLE TA RE A WHERE TERMINAL IS NO T PERMITTED v v A G V FIXED CLOSED FIXED CLOSED OPERABLE OPERABLE V C B B B B F B V V A J V H M X X V V K B E D L POWER VENT (using room air for combustion) EXTERIOR CLEARANCES FOR SIDE WA LL VENT TERMINA TION FIGURE 15. V ent terminal c[...]
-
Page 21
21 PLANNING THE VENT SYSTEM Plan the route of the vent system from the discharge of the blower to the planned location of the vent terminal. Refer to V AA instruction on page 26 while planning the vent system. 1. Layout total vent system to use a min im um of vent pipe and elbows. 2. Thiswater heateris capableofventing ?[...]
-
Page 22
22 The condensate trap may be primed by lling the CONDENSA TE U-ASSEMBL Y with tap water while the water heater is not operating. The system is fully primed when the water level reaches the adaptor connected into the T ee. In most installations the water heater will self-prime thecondensate trap during?[...]
-
Page 23
23 CAUTION LABEL ALL WIRES PRIOR TO DISCONNECTION WHEN SERVICING CONTROLS. WIRING ERRORS CAN CAUSE IMPROPER AND DANGEROUS OPERA TION. VERIFY PROPER OPERA TION AFTER SERVICING. POWER VENT WIRING SCHEMA TIC - FIGURE 19. may be easier to mark both the inside and outside wall. Align holes by drilling a hole through center of the template from the insid[...]
-
Page 24
24 INST ALLA TION OF VENT SYSTEM, SIDEW ALL With the route of the venting system and selection of materials completed, as discussed in the section of this manual titled PLANNING THE VENT SYSTEM, the through the wallvent terminal in place and the rst section of piping, up to rst elbow ,[...]
-
Page 25
25 VENT A TTENUA TI ON ASSEMBL Y I N ST ALL A T I O N I NSTRUC T I ON S The V ent Attenuation Assembly (V AA) is designed to provide a reduction in fan noise created in the blower wheel. This installation of this V AA is optional. Review directions thoroughly prior to installing the new V AA. Please contact the manufac[...]
-
Page 26
26 bar b, use a wir e tie o r hose c lam p ( not sup plie d with k it) and secure. 6. T ake th e other e nd of th e fl exible t ubing a nd sli de it thr ough the h ose c lamp o n the jac ket top c over and inst all i t into one of the f our bar b f it ting s in vent pip e asse mbly # 2. 7. Once installed?[...]
-
Page 27
27 VENT PIPE PREP ARA TION 1. INITIAL PREP ARA TION A. Make sure the solvent cement you are planning to use is designedforthespecicapplicationyouareattempting. B. Know the physical and chemical characteristics and limitations of the PVC and CPVC piping materials that you are about to use. C. Know the reputation of your manuf[...]
-
Page 28
28 B. Deburring Usea knife, plasticpipe deburring tool,or le toremove burrs fromthe end of small diameter pipe. Be sure to remove all burrs from around the inside as well as the outside of the pipe. A slight chamfer (bevel) of about 10°-15° shou[...]
-
Page 29
29 FOR YOUR SAFETY READ BEFORE OPERA TING W ARNING: If you do not follow these instructions exactly , a re or explosion may result causing property damage, personal injury or loss of life. A. This appliance does not have a pilot. It is equipped with an ignition device which automatically lights the burner . Do NOT try to light the burner by hand[...]
-
Page 30
30 It is recommended that lower water temperatures be used to avoid the risk of scalding. It is further recommended, in all cases, that the water temperaturebe set for thelowest temperature whichsatises your hot water needs. This will also provide the most energy efcient operat[...]
-
Page 31
31 FOR YOUR INFORMA TION ST ART UP CONDITIONS SMOKE/ODOR It is not uncommon to experience a small amount of smoke and odor during the initial start-up. This is due to burning of f of oil from metal parts, and will disappear in a short while. STRANGE SOUNDS Possible noises due to expansion and contraction of some metal parts during periods of heat-u[...]
-
Page 32
32 VENTING SYSTEM INSPECTION At least once a year a visual inspection should be made of the venting system. Y ou should look for: 1. Obstructions which could cause improper venting. The combustion andventilationairowmustnotbeobstructed. 2. Damage or deterioration which could cause improper venting or leakage of combustion pr[...]
-
Page 33
33 The anode rod is used to protect the tank from corrosion. Most hot water tanksareequipped withan anoderod. Thesubmergedrodsacrices itself to protect the tank. Instead of corroding tank, water ions attack and eat away the anode rod. This does not affect water ’s taste or[...]
-
Page 34
34 LEAKAGE CHECKPOINTS Neveruse thiswaterheater unlessit iscompletelylled withwater . T o prevent damage to the tank, the tank must be lled with water . W atermustowfromthe hotwaterfaucetbeforeturning“ON” gas to the wa[...]
-
Page 35
35 TROUBLESHOOTING GUIDELINES TROUBLE SHOOTING Pleasecheckguidelinesbelow .Foryoursafety ,waterheaterserviceshouldbeperformedonlybyaqualiedservicetechnician. ReadtheGENERAL SAFETYINFORMA TIONsectionrst. INTELLI-VENT TROUBLESHOOTING CHART - USER CONTROL PROBLEM SO[...]
-
Page 36
36 TROUBLESHOOTING GUIDELINES TROUBLE SHOOTING Pleasecheckguidelinesbelow .Foryoursafety ,waterheaterserviceshouldbeperformedonlybyaqualiedservicetechnician. ReadtheGENERAL SAFETYINFORMA TIONsectionrst. INTELLI-VENT TROUBLESHOOTING CHART - USER CONTROL PROBLE MS [...]
-
Page 37
37 TROUBLESHOOTING GUIDELINES TROUBLE SHOOTING Pleasecheckguidelinesbelow .Foryoursafety ,waterheaterserviceshouldbeperformedonlybyaqualiedservicetechnician. ReadtheGENERAL SAFETYINFORMA TIONsectionrst. INTELLI-VENT TROUBLESHOOTING CHART - USER CONTROL PROBLE MS [...]
-
Page 38
38 Theseguidelinesshouldbeutilizedbyaqualiedserviceagent. TROUBLESHOOTING GUIDELINES TROUBLESHOOTING GUIDELINES[...]
-
Page 39
39 Limited W arranty State Industries, Inc., the warrantor , extends the following LIMITED WARRANTY to the owner of this water heater . 1. THE T ANK If the glass-lined tank in this water heater shall prove upon examination by the warrantor to have leaked due to natural corrosion from potable water therein, during the rst THREE years?[...]
-
Page 40
www .statewaterheaters.com 500 T ennessee W altz Parkway Ashland City , TN 37015 T echnical Support 800-365-0024 Parts 800-821-2017[...]