Sunrise Global 13-05020 manuel d'utilisation
- Voir en ligne ou télécharger le manuel d’utilisation
- 24 pages
- 0.72 mb
Aller à la page of
Les manuels d’utilisation similaires
-
Frozen Dessert Maker
Sunrise Global and CM500 IP
127 pages 2.3 mb -
Frozen Dessert Maker
Sunrise Global CM100 IP
127 pages 2.3 mb -
Frozen Dessert Maker
Sunrise Global CM250 IP
127 pages 2.3 mb -
Electric Heater
Sunrise Global 13-05024
24 pages 0.72 mb -
Electric Heater
Sunrise Global 13-05020
24 pages 0.72 mb -
Outdoor Kitchen Island
Sunrise Global CE4000
65 pages 1.59 mb -
Outdoor Kitchen Island
Sunrise Global Cable Explorer TDR Module
65 pages 1.59 mb
Un bon manuel d’utilisation
Les règles imposent au revendeur l'obligation de fournir à l'acheteur, avec des marchandises, le manuel d’utilisation Sunrise Global 13-05020. Le manque du manuel d’utilisation ou les informations incorrectes fournies au consommateur sont à la base d'une plainte pour non-conformité du dispositif avec le contrat. Conformément à la loi, l’inclusion du manuel d’utilisation sous une forme autre que le papier est autorisée, ce qui est souvent utilisé récemment, en incluant la forme graphique ou électronique du manuel Sunrise Global 13-05020 ou les vidéos d'instruction pour les utilisateurs. La condition est son caractère lisible et compréhensible.
Qu'est ce que le manuel d’utilisation?
Le mot vient du latin "Instructio", à savoir organiser. Ainsi, le manuel d’utilisation Sunrise Global 13-05020 décrit les étapes de la procédure. Le but du manuel d’utilisation est d’instruire, de faciliter le démarrage, l'utilisation de l'équipement ou l'exécution des actions spécifiques. Le manuel d’utilisation est une collection d'informations sur l'objet/service, une indice.
Malheureusement, peu d'utilisateurs prennent le temps de lire le manuel d’utilisation, et un bon manuel permet non seulement d’apprendre à connaître un certain nombre de fonctionnalités supplémentaires du dispositif acheté, mais aussi éviter la majorité des défaillances.
Donc, ce qui devrait contenir le manuel parfait?
Tout d'abord, le manuel d’utilisation Sunrise Global 13-05020 devrait contenir:
- informations sur les caractéristiques techniques du dispositif Sunrise Global 13-05020
- nom du fabricant et année de fabrication Sunrise Global 13-05020
- instructions d'utilisation, de réglage et d’entretien de l'équipement Sunrise Global 13-05020
- signes de sécurité et attestations confirmant la conformité avec les normes pertinentes
Pourquoi nous ne lisons pas les manuels d’utilisation?
Habituellement, cela est dû au manque de temps et de certitude quant à la fonctionnalité spécifique de l'équipement acheté. Malheureusement, la connexion et le démarrage Sunrise Global 13-05020 ne suffisent pas. Le manuel d’utilisation contient un certain nombre de lignes directrices concernant les fonctionnalités spécifiques, la sécurité, les méthodes d'entretien (même les moyens qui doivent être utilisés), les défauts possibles Sunrise Global 13-05020 et les moyens de résoudre des problèmes communs lors de l'utilisation. Enfin, le manuel contient les coordonnées du service Sunrise Global en l'absence de l'efficacité des solutions proposées. Actuellement, les manuels d’utilisation sous la forme d'animations intéressantes et de vidéos pédagogiques qui sont meilleurs que la brochure, sont très populaires. Ce type de manuel permet à l'utilisateur de voir toute la vidéo d'instruction sans sauter les spécifications et les descriptions techniques compliquées Sunrise Global 13-05020, comme c’est le cas pour la version papier.
Pourquoi lire le manuel d’utilisation?
Tout d'abord, il contient la réponse sur la structure, les possibilités du dispositif Sunrise Global 13-05020, l'utilisation de divers accessoires et une gamme d'informations pour profiter pleinement de toutes les fonctionnalités et commodités.
Après un achat réussi de l’équipement/dispositif, prenez un moment pour vous familiariser avec toutes les parties du manuel d'utilisation Sunrise Global 13-05020. À l'heure actuelle, ils sont soigneusement préparés et traduits pour qu'ils soient non seulement compréhensibles pour les utilisateurs, mais pour qu’ils remplissent leur fonction de base de l'information et d’aide.
Table des matières du manuel d’utilisation
-
Page 1
OWNER’S MANUAL CANADIAN ST ANDARDS MINI-SPLIT HEA T PUMP (SEER 16) 12,000 BTU 12,000 BTU COOLING 13,000 BTU HEA TING Before using this air conditioner , please read the following instructions carefully and keep this manual along with your proof of purchase in a safe place for future reference. MODELS: 13-05020 / 13-05024 00228-16/01/07 © Copyrig[...]
-
Page 2
Safety precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2 Air conditioner diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 Remote control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 Remote control operation . . . . . . . . . . . [...]
-
Page 3
2 SAFETY PRECAUTIONS Legend of symbols used in this manual : Not to do. Be sure to follow instructions. Grounding is necessary . Feature of the appliance (not a defect). Pay attention. W arning: Incorrect handling may cause serious hazards and/or injuries. Only to the attention of electricians or technicians : T o eliminate risks of short circuits [...]
-
Page 4
3 AIR CONDITIONER DIAGRAM INDOOR UNIT Air in Display Surface panel Front case Air out Louvers Remote control Drain hose Air in Heating Cooling Auto Power/Run Air out Actual model may differ from the diagram Suction and liquid refrige- rant piping and wiring OUTDOOR UNIT[...]
-
Page 5
4 REMOTE CONTROL NOTE : • Don’t mix new with used batteries or batteries of different types. • If you are not using the remote control for a long period of time, remove the batteries to eliminate potential battery leakage. • The remote control should be kept at least 1 m or more away from the TV set or any other electric or electronic appli[...]
-
Page 6
T wo buttons to set the temperature When unit is running under AUTO, COOL, F AN, HEA T , press this button to select the fan speed. AUTO mode, LOW fan, MED fan, HIGH fan. In DEHUMIDIFYING mode the fan speed is set to LOW and cannot be changed. Press this button to select the operation mode desired. AUTO,COOLING,DEHUMI- DIFYING, F AN, HEA T Press cl[...]
-
Page 7
6 REMOTE CONTROL OPERA TION LIQUID CRYST AL DISPLA Y Show all set functions. ON/OFF Press this key to turn the unit on or off. Press on SWING to start the automatic oscillation of the louvers. Press again to cancel or stop oscillation. Press T -OFF to stop the air conditioner at a desired time. Once pressed, OFF and clock icon will flash. With the [...]
-
Page 8
7 SAFETY NOTES Always set the most adequate temperature. It is recommend to set the temperature about 5°C cooler than the outside temperature to reduce energy costs. Keep doors and windows closed when the air conditioner is running, otherwise it could affect the air conditioner cooling ef ficiency . Do not splash water or other liquid on the air c[...]
-
Page 9
8 MAINTENANCE CAUTION T urn power off and then cut the circuit-breaker of f before cleaning the air conditioner . Never spray water on the indoor and outdoor units when cleaning the air conditioner . Always use a dry soft cloth and warm water , without or with a mild detergent. 1. T o remove, pull the front panel in the direction of the arrows. Gen[...]
-
Page 10
MAINTENANCE 1. Remove the air filters, as described in step #1 of “Cleaning the air filters” section. 2. T ake the active-carbon air filters out of the bag and place them into the filter frames. • Be cautious not cut yourself on the fins. 3. Reinstall the air filters, as described in step #3 of “Cleaning the air filers” section. • If yo[...]
-
Page 11
10 TROUBLESHOOTING The air conditioner does not run immediately after the power key is pressed on. There is an unusual odour coming out of the air outlet grills when the air conditioner is running. A clicking noise can be heard when the unit is turned on or shut off. Air cooling is not efficient. The remote control does not work. The air conditione[...]
-
Page 12
11 TROUBLESHOOTING Unusual noise can be heard during operation. Power fuse or switch often breaks. Carelessly splash water or something into air conditioner . Electrical lines and power plug are very hot. Wind blowing from the outlet smells bad during operation. W ater is leaking on the inside wall. Tradex Corp. Tradex Corp. www.sunrisetradex.com 1[...]
-
Page 13
12 TECHNICAL SPECIFICA TIONS MODEL FUNCTIONS ACCESSORY COOLING CAP ACITY (W) HEA TING CAP ACITY (W) POWER SUPPL Y FREQUENCY COOLING / HEA TING RA TED CURRENT MAXIMUM INPUT CURRENT COOLING / HEA TING RA TED POWER COOLING / HEA TING RA TED INPUT RECYCLING AIR VOLUME (m 3 /h) REFRIGERANT AND WEIGHT W A TER PROOF LEVEL NOISE (INDOOR / OUTDOOR) dB (A) C[...]
-
Page 14
13 INST ALLA TION SETUP DIAGRAM Space to the ceiling Space to the wall Space to the wall Insulation tape Air outlet side Space to the cover Air intake side Space to the wall Space to the wall 30cm or more 200cm or more 50cm or more 30cm or more 50cm or more 15cm or more 300cm or more 15cm or more 15cm or more 200cm or more IMPORT ANT NOTES • The [...]
-
Page 15
14 INST ALLA TION LOCA TION INDOOR UNIT 1. The inlet and outlet should not be covered so that the outflow air can reach all parts of the room. 2. Install in a location where is permitting easy connection with the outdoor unit. 3. A location from which the condensation water can be drained out conveniently . 4. Avoid a location where there is heat s[...]
-
Page 16
15 INST ALLA TION INSTRUCTIONS INST ALL THE REAR P ANEL 1. Always mount the rear panel horizontally . 2. Fix the rear panel on the selected location with screws supplied with the unit. 3. Be sure that the rear panel has been fixed firmly enough to withstand the weight of an adult of 60 kg (132.3 lbs.), furthermore, the weight should be evenly share[...]
-
Page 17
16 INST ALLA TION INSTRUCTIONS ELECTRICAL WIRING - INDOOR UNIT *Only an electrician must do the connection of this unit. Note: The power of indoor unit is supplied by the outdoor unit.The outside disconnect switch must be installed between electrical panel and condensing unit. Operation procedures: 1. Open the surface panel. 2. Open the cover and c[...]
-
Page 18
17 INST ALLA TION INSTRUCTIONS IMPORT ANT NOTICE 1. Wiring should be properly installed. 2. T ighten the screws on the terminal board. 3. Pull on each wire and make sure they are solidly in place. 4. Wrong wiring will cause unit to work abnormally and/or damage the unit. 5. Wrong wire grounding may cause short circuit. Wiring cover T erminal Wire c[...]
-
Page 19
18 INST ALLA TION INSTRUCTIONS ELECTRICAL WIRING - OUTDOOR UNIT IMPORT ANT NOTICE 1. Wiring should be properly installed. 2. T ighten the screws on the terminal board. 3. Pull on each wire and make sure they are solidly in place. 4. Wrong wiring will cause unit to work abnormally and/or damage the unit. 5. Wrong wire grounding may cause short circu[...]
-
Page 20
1. When routing the piping and wiring from the left or right side of the indoor unit, cut off the tai - lings from the chassis in neces- sary (shown in Fig.4, (a), (b) (c)). (1) Cut off the tailings 1 when routing the wiring only . (2) Cut off the tailings 1 and tai- lings 2 (or tailings 1, tailings 2 and tailings 3) when routing both the wiring an[...]
-
Page 21
20 AIR PURGING AND LEAKAGE TEST 1. T ake out the nut cover of the inlet for refrigerant. 2. Connect the tube of the vacuum watch with the vacuum pump, having the low- pressure end linking to the inlet for refri- gerant. 3. Starting the vacuum pump, when the indicator turns to -1 bar , closing the low pressure handle and stopping vacuu- mize. Keep f[...]
-
Page 22
21 TEST OPERA TION 1. Before test operation (1) Do not switch on power before installation is finished completely . (2) Electric wiring must be connected cor- rectly and securely . (3) Cut-off valves of the connection pipes should be opened. (4) All the impurities such as scraps and thrums must be clear from the unit. (5) Open the surface panel and[...]
-
Page 23
22 IMPORT ANT NOTICE • Always consult a qualified electrician to install the unit. • Please contact the after sales service for any problems. • If you have to carry your air conditioner in down position, it is suggested to wait 12 hours before you restart the machine. • During winter , it is recommanded to isolate the compressor of the outd[...]
-
Page 24
LIMITED W ARRANTY This air conditioner is covered by a warranty against defects in materials and workmanship including the compressor , if used for the applications specified in this owner ’s manual, if installed by a Sunrise T radex Corp. certified installer , for a period of ONE (1) year from the date of original purchase in Canada. NOTE: the c[...]