Thermo Products AH2-A manuel d'utilisation
- Voir en ligne ou télécharger le manuel d’utilisation
- 22 pages
- 0.59 mb
Aller à la page of
Les manuels d’utilisation similaires
-
Air Conditioner
Thermo Products OPB (24
91 pages 2.12 mb -
Furnace
Thermo Products OL6RA072D48(B/R)
75 pages 2.49 mb -
Furnace
Thermo Products OH2-56
32 pages 1.34 mb -
Burner
Thermo Products MG-1018
11 pages 0.1 mb -
Furnace
Thermo Products OD6RA072D48R
76 pages 3 mb -
Furnace
Thermo Products CHX3-125N
65 pages 3.34 mb -
Furnace
Thermo Products OL20-151
32 pages 1.34 mb -
Burner
Thermo Products PGT11-125
38 pages 1.16 mb
Un bon manuel d’utilisation
Les règles imposent au revendeur l'obligation de fournir à l'acheteur, avec des marchandises, le manuel d’utilisation Thermo Products AH2-A. Le manque du manuel d’utilisation ou les informations incorrectes fournies au consommateur sont à la base d'une plainte pour non-conformité du dispositif avec le contrat. Conformément à la loi, l’inclusion du manuel d’utilisation sous une forme autre que le papier est autorisée, ce qui est souvent utilisé récemment, en incluant la forme graphique ou électronique du manuel Thermo Products AH2-A ou les vidéos d'instruction pour les utilisateurs. La condition est son caractère lisible et compréhensible.
Qu'est ce que le manuel d’utilisation?
Le mot vient du latin "Instructio", à savoir organiser. Ainsi, le manuel d’utilisation Thermo Products AH2-A décrit les étapes de la procédure. Le but du manuel d’utilisation est d’instruire, de faciliter le démarrage, l'utilisation de l'équipement ou l'exécution des actions spécifiques. Le manuel d’utilisation est une collection d'informations sur l'objet/service, une indice.
Malheureusement, peu d'utilisateurs prennent le temps de lire le manuel d’utilisation, et un bon manuel permet non seulement d’apprendre à connaître un certain nombre de fonctionnalités supplémentaires du dispositif acheté, mais aussi éviter la majorité des défaillances.
Donc, ce qui devrait contenir le manuel parfait?
Tout d'abord, le manuel d’utilisation Thermo Products AH2-A devrait contenir:
- informations sur les caractéristiques techniques du dispositif Thermo Products AH2-A
- nom du fabricant et année de fabrication Thermo Products AH2-A
- instructions d'utilisation, de réglage et d’entretien de l'équipement Thermo Products AH2-A
- signes de sécurité et attestations confirmant la conformité avec les normes pertinentes
Pourquoi nous ne lisons pas les manuels d’utilisation?
Habituellement, cela est dû au manque de temps et de certitude quant à la fonctionnalité spécifique de l'équipement acheté. Malheureusement, la connexion et le démarrage Thermo Products AH2-A ne suffisent pas. Le manuel d’utilisation contient un certain nombre de lignes directrices concernant les fonctionnalités spécifiques, la sécurité, les méthodes d'entretien (même les moyens qui doivent être utilisés), les défauts possibles Thermo Products AH2-A et les moyens de résoudre des problèmes communs lors de l'utilisation. Enfin, le manuel contient les coordonnées du service Thermo Products en l'absence de l'efficacité des solutions proposées. Actuellement, les manuels d’utilisation sous la forme d'animations intéressantes et de vidéos pédagogiques qui sont meilleurs que la brochure, sont très populaires. Ce type de manuel permet à l'utilisateur de voir toute la vidéo d'instruction sans sauter les spécifications et les descriptions techniques compliquées Thermo Products AH2-A, comme c’est le cas pour la version papier.
Pourquoi lire le manuel d’utilisation?
Tout d'abord, il contient la réponse sur la structure, les possibilités du dispositif Thermo Products AH2-A, l'utilisation de divers accessoires et une gamme d'informations pour profiter pleinement de toutes les fonctionnalités et commodités.
Après un achat réussi de l’équipement/dispositif, prenez un moment pour vous familiariser avec toutes les parties du manuel d'utilisation Thermo Products AH2-A. À l'heure actuelle, ils sont soigneusement préparés et traduits pour qu'ils soient non seulement compréhensibles pour les utilisateurs, mais pour qu’ils remplissent leur fonction de base de l'information et d’aide.
Table des matières du manuel d’utilisation
-
Page 1
MAC-165 ECN 4392-MA 10 & 12 SEER AIR HANDLER INSTALLATION & SERVICE MANUAL MODELS: AH1-A, AH2-A PLEASE READ THE SE INSTRUCT IONS PRIOR TO INSTALLAT ION AND BEFORE PERFORMING ANY SERVICE OR MAINTENANCE. THES E INSTRUCTIONS MUST BE LEFT WITH T HE USER AND SHOUL D BE RETAINE D FOR FUTURE REFERENCE BY QUALIFIED SERVICE PERSONNEL. : Improper ins[...]
-
Page 2
TABLE OF C ONTENTS SECTION B E G I N N I N G P A G E S A F E T Y S E C T I O N 1 KNOCKDOWN OF AIR HANDLER 3 REASSEMBLY OF AIR HANDL ER 3 I NSTALLATI ON OF A-COI L I N A VERTICAL APPLI CATION 3 I NSTALLATI ON OF A-COI L I N A HORIZ ONTAL APPLI CATION 4 I NSTALL ATION OF HOT WATER COIL 6 BLOWER AIR ADJ USTMENT 7 D U C T S Y S T E M 9 CFM CAPACITY CHA[...]
-
Page 3
All installatio ns and services must be performed by qualified personnel. 1 SAFETY SECTION This page contains various warning s and cautions found throughout this Service and Installation Manual. Please read and comp ly with t he statements on the cover and the statem ents below. : Improper installation, adjustment, alteration, service, or maintena[...]
-
Page 4
All installatio ns and services must be performed by qualified personnel. 2 I nstallation and service personnel are required by some states to be licensed. Persons not qualified shall not insta ll this equipment nor interpre t these instructions. All local codes and regulations take precedence over the instructions in this manual and should be foll[...]
-
Page 5
All installatio ns and services must be performed by qualified personnel. 3 FOLLOW THESE STEP S FOR K NOCKDOWN OF AIR HAND LER: 1. Start with unit setting in a vertical position. (Fig ure A) 2. Remove screws from bottom door, middle door, top door, and top front panel. Remove doors and top panel of air handler. 3. Disconnect blower leads from blowe[...]
-
Page 6
All installatio ns and services must be performed by qualified personnel. 4 INSTALLATIONS OF A-COIL IN HORIZONTAL AP PLICATION For the AH1-A, in all A-coil applications (1024E, 1030E, 1036E, and 1224-30G1) except the 1236G1, the A-coil spacer must be used. For the AH2-A, in all A-coi l applications t he A-coil spacer must be used. 1. Remove bottom [...]
-
Page 7
All installatio ns and services must be performed by qualified personnel. 5 13. Position grommets in coil access panel to allow installation of trim plate, secure trim plate in place with screws, and seal connections with duct sealer or equivalent. NOTE: The air handler is factory assembled for left to right(horizontal) and vertical applications. I[...]
-
Page 8
All installatio ns and services must be performed by qualified personnel. 6 Figure B3 INSTALLATION OF THE HOT WATER COIL: 1. Remove top door of air handler. 2. Slide hot water c oil's side hang er brackets into coil c hannel(retaining channel) in the a ir handler. See Figure B4 inset. Figure B4 3. Push coil into unit until the coil is stopped [...]
-
Page 9
All installatio ns and services must be performed by qualified personnel. 7 5. Make appropriate hy dronic connections to inlet(blower side) and outlet(duct side) of coil and braze into place. 6. Seal connections through panel with duct sealer or equivalent. : If drilling or scre wing into panel or plate is ne cessary , make ce rtain drill does not [...]
-
Page 10
All installatio ns and services must be performed by qualified personnel. 8 1. Determine the appropriate blower spe ed settings listed in table s below. 2. Set the blower motor speed to match air conditioning requirement, connect the red wire(cooling tap) to the appropriate fan speed on the ter minal strip located on the blower( see Figure D). 3. S[...]
-
Page 11
All installatio ns and services must be performed by qualified personnel. 9 DUCT SYSTE M The duct sy stem and load sizing calculation should follow the design standards of Air Conditioning Contractors of America (ACCA) - manuals D & J - or the American Society of Heating, Refrige ration and Air Conditioning Engineers, I nc. (ASHRAE) Latest Edit[...]
-
Page 12
All installatio ns and services must be performed by qualified personnel. 10 CFM CAPACITY CHARTS AH 1- A .2 D u ct Sta tic Pr e ssu r e wit h heat ing c oi l A nd appli c abl e E v apor at or C oil M odel CFM (HI ) CFM (M. HI ) CFM (M. LOW ) CFM (LOW ) 1024E and 1030E 1299 1123 992 821 1224-3 0G1 1756 1202 1073 880 1036E 1435 1231 1055 861 1236G1 1[...]
-
Page 13
All installatio ns and services must be performed by qualified personnel. 11 DUCT SIZES FOR HOMES Velocity Approximately 800 F eet Per Minute THE INDOOR EVAPORATOR COIL 1. EVAPORATOR COIL is a finned coil through which air in the home is circulated. Heat from the air is transfer red to the liquid refrig erant inside the e vaporator coil. The c oils[...]
-
Page 14
All installatio ns and services must be performed by qualified personnel. 12 TUBING LIN E SETS 1. SUCTION L INE is an insulated large copper tube connecting the outlet of the A/C evaporator to the suction inlet of the A/C CONDENSER. 2. LIQUID LINE is a single small tube connecting the outlet of the A/C condenser to the expansion valve inlet on the [...]
-
Page 15
All installatio ns and services must be performed by qualified personnel. 13 75’-100’ TOTAL LI NE LENGTH MODEL SUCTION LINE LIQUID LINE 1224 & 1230 1” 1/2” 1236 & 1242 1-1/8” 5/8” NOTES: For line lengths over 25’ adjust charge accordingly per foot of variation from chart. .65 oz. per foot for 3/8” and 3/4” line set .674 oz[...]
-
Page 16
All installatio ns and services must be performed by qualified personnel. 14 Fig ur e F 2. A trap is necessary in the suction line at the indoor evaporator coil if the indoor evaporator coil is more than 4 feet below the outdoor condensing unit. NOTE: Multiple suc tion line traps are re commended for long er or multiple horizontal line s. (See Fig.[...]
-
Page 17
All installatio ns and services must be performed by qualified personnel. 15 A gradual loop in the tubing can be constructed to take up the ex cess tubing if y ou find that too much tubing has been brought onto a job. Such a loop MUST be kept in a horizontal (flat) plane to avoid trapping the oil. Refrigerant lines should be inserted into a suitabl[...]
-
Page 18
All installatio ns and services must be performed by qualified personnel. 16 Read th e temperat ure at header assemb ly t o calculate th e superheat. Then read the suction pressure and then add the line loss of 2 lbs. for 25’ of tubing. Then convert pressure into temperature. Next, subtract the converted suction temperature from the measured coil[...]
-
Page 19
All installatio ns and services must be performed by qualified personnel. 17 The following points must be checked by the inst aller and/or electri cian before the air conditioning sy stem is started: 1. Check every electrical connection of "PUSH-ON" or "S CREW -ON" terminal s to ensure it i s on tightly on its proper post. 2. Re[...]
-
Page 20
All installatio ns and services must be performed by qualified personnel. 18 A return air opening can be cut in any of the four sides or the bottom of the UA cabinet. The AH AI R HANDLER is then placed on the UA adapter cabinet , inlet side down. The AH rests on t he support angles of the UA adapter cabinet. The UA cabinet is equipped with a perman[...]
-
Page 21
All installatio ns and services must be performed by qualified personnel. 19 REPLACEMENT PARTS[...]
-
Page 22
All installatio ns and services must be performed by qualified personnel. 20 AH2 - A Ai r Han d l e r wi t h HC2 - A Hy d r on i c Co i l O ut l et Ai r Tem er at ur e vs. H eat i n g C apaci t y ( GPM , PSI , Coi l Dr o p) 90 95 100 105 110 115 120 125 130 135 140 145 40 60 80 100 120 Heat i ng Capa c i t y ( M bt uh) Air Temp. (deg. F) 7 G PM ( .[...]