American Dryer Corp. ADS-464 II manuale d’uso
- Visualizza on-line o scarica il manuale
- 80 pagine
- 1.77 mb
Vai alla pagina of
Manuali d’uso simili
-
Clothes Dryer
American Dryer Corp. ADG-220
24 pagine 0.18 mb -
Clothes Dryer
American Dryer Corp. AD-30V
76 pagine 3.57 mb -
Clothes Dryer
American Dryer Corp. AD-758V
52 pagine 1.95 mb -
Clothes Dryer
American Dryer Corp. AD-410
72 pagine 2.06 mb -
Clothes Dryer
American Dryer Corp. MDG50PNH
48 pagine 4.2 mb -
Clothes Dryer
American Dryer Corp. AD-50
107 pagine 1.33 mb -
Clothes Dryer
American Dryer Corp. Hot Surface Ignition ADG-530HS
34 pagine 1.6 mb -
Clothes Dryer
American Dryer Corp. AD-758
66 pagine 2.76 mb
Un buon manuale d’uso
Le regole impongono al rivenditore l'obbligo di fornire all'acquirente, insieme alle merci, il manuale d’uso American Dryer Corp. ADS-464 II. La mancanza del manuale d’uso o le informazioni errate fornite al consumatore sono la base di una denuncia in caso di inosservanza del dispositivo con il contratto. Secondo la legge, l’inclusione del manuale d’uso in una forma diversa da quella cartacea è permessa, che viene spesso utilizzato recentemente, includendo una forma grafica o elettronica American Dryer Corp. ADS-464 II o video didattici per gli utenti. La condizione è il suo carattere leggibile e comprensibile.
Che cosa è il manuale d’uso?
La parola deriva dal latino "instructio", cioè organizzare. Così, il manuale d’uso American Dryer Corp. ADS-464 II descrive le fasi del procedimento. Lo scopo del manuale d’uso è istruire, facilitare lo avviamento, l'uso di attrezzature o l’esecuzione di determinate azioni. Il manuale è una raccolta di informazioni sull'oggetto/servizio, un suggerimento.
Purtroppo, pochi utenti prendono il tempo di leggere il manuale d’uso, e un buono manuale non solo permette di conoscere una serie di funzionalità aggiuntive del dispositivo acquistato, ma anche evitare la maggioranza dei guasti.
Quindi cosa dovrebbe contenere il manuale perfetto?
Innanzitutto, il manuale d’uso American Dryer Corp. ADS-464 II dovrebbe contenere:
- informazioni sui dati tecnici del dispositivo American Dryer Corp. ADS-464 II
- nome del fabbricante e anno di fabbricazione American Dryer Corp. ADS-464 II
- istruzioni per l'uso, la regolazione e la manutenzione delle attrezzature American Dryer Corp. ADS-464 II
- segnaletica di sicurezza e certificati che confermano la conformità con le norme pertinenti
Perché non leggiamo i manuali d’uso?
Generalmente questo è dovuto alla mancanza di tempo e certezza per quanto riguarda la funzionalità specifica delle attrezzature acquistate. Purtroppo, la connessione e l’avvio American Dryer Corp. ADS-464 II non sono sufficienti. Questo manuale contiene una serie di linee guida per funzionalità specifiche, la sicurezza, metodi di manutenzione (anche i mezzi che dovrebbero essere usati), eventuali difetti American Dryer Corp. ADS-464 II e modi per risolvere i problemi più comuni durante l'uso. Infine, il manuale contiene le coordinate del servizio American Dryer Corp. in assenza dell'efficacia delle soluzioni proposte. Attualmente, i manuali d’uso sotto forma di animazioni interessanti e video didattici che sono migliori che la brochure suscitano un interesse considerevole. Questo tipo di manuale permette all'utente di visualizzare tutto il video didattico senza saltare le specifiche e complicate descrizioni tecniche American Dryer Corp. ADS-464 II, come nel caso della versione cartacea.
Perché leggere il manuale d’uso?
Prima di tutto, contiene la risposta sulla struttura, le possibilità del dispositivo American Dryer Corp. ADS-464 II, l'uso di vari accessori ed una serie di informazioni per sfruttare totalmente tutte le caratteristiche e servizi.
Dopo l'acquisto di successo di attrezzature/dispositivo, prendere un momento per familiarizzare con tutte le parti del manuale d'uso American Dryer Corp. ADS-464 II. Attualmente, sono preparati con cura e tradotti per essere comprensibili non solo per gli utenti, ma per svolgere la loro funzione di base di informazioni e di aiuto.
Sommario del manuale d’uso
-
Pagina 1
ADS-464 II Installation/Operator’s Manual 011700DX/pb ADC Part No. 113074 W ARNING: For your safety the information in this manual must be followed to minimize the risk of fire or explosion or to prevent property damage, personal injury or death. Do not store or use gasoline or other flammable vapor and liquids in the vicinity of this or any othe[...]
-
Pagina 2
W e have tried to make this manual as complete as possible and hope you will find it useful. ADC reserves the right to make changes from time to time, without notice or obligation, in prices, specifications, colors, and material, and to change or discontinue models. Important For your convenience, log the following information: Replacement parts ca[...]
-
Pagina 3
IMPOR T ANT YOU MUST DISCONNECT and LOCKOUT THE ELECTRIC SUPPL Y and THE STEAM SUPPL Y BEFORE ANY COVERS or GUARDS ARE REMOVED FROM THE MACHINE TO ALLOW ACCESS FOR CLEANING , ADJUSTING , INST ALLA TION, or TESTING OF ANY EQUIPMENT per OSHA (Occupational Safety and Health Administration) ST ANDARDS. CHILDREN SHOULD NOT BE ALLOWED TO PLA Y ON OR NEAR[...]
-
Pagina 4
W ARNING The dryer must never be operated with any of the back guards, outer tops, or service panels r emoved. PERSONAL INJUR Y or FIRE COULD RESUL T . IMPOR T ANT PLEASE OBSER VE ALL SAFETY PRECAUTIONS displayed on the equipment or specified in the installation/operator's manual included with the dryer . Dryers must not be installed or stored[...]
-
Pagina 5
Table of Contents SECTION I IMPOR T ANT INFORMA TION ........................................................................................................ 3 A. Receiving and Handling ............................................................................................................... 3 B. Safety Precautions ............................[...]
-
Pagina 6
SECTION VII SER VICE/P AR TS INFORMA TION ................................................................................................ 40 A. Service ..................................................................................................................................... 40 B . Parts ..................................................[...]
-
Pagina 7
3 SECTION I IMPOR T ANT INFORMA TION A. RECEIVING and HANDLING The dryer is shipped in a protective stretch wrap cover with protective cardboard corners and top cover (or optional box) as a means of preventing damage in transit. Upon delivery , the dryer and packaging, and wooden skid should be visually inspected for shipping damage. If any damage [...]
-
Pagina 8
4 B. SAFETY PRECAUTIONS W ARNING: For your safety , the information in this manual must be followed to minimize the risk of fire or explosion or to prevent property damage, personal injury , or loss of life. W ARNING: The dryer must never be operated with any of the back guards, outer tops, or service panels removed. PERSONAL INJUR Y or FIRE COULD [...]
-
Pagina 9
5 7. This dryer is not to be used in the presence of dry cleaning solvents or fumes. 8. Remove articles from the dryer as soon as the dryer cycle has been completed. W ARNING: Articles left in the dryer after the drying and cooling cycles have been completed can create a fire hazard. 9. READ and FOLLOW ALL CAUTION and DIRECTION LABELS A T T ACHED T[...]
-
Pagina 10
6 SECTION II SPECIFICA TIONS/DIMENSIONS A. SPECIFICA TIONS NOTE : ADC reserves the right to make changes in specifications at any time, without notice or obligation. M A X I M U M CA P A CI T Y ( D RY W EIGHT ) 460 l bs. 208.66 kg T ot al W ei g h t 10,500 l bs. 4,762. 7 kg T ot al Sh i ppi n g W ei g h t 10,800 l bs. 4,898. 8 kg T i l t H e i g h [...]
-
Pagina 11
7 B. DIMENSIONS NOTE : ADC reserves the right to make changes in specifications at any time, without notice or obligation.[...]
-
Pagina 12
8 SECTION III INST ALLA TION PROCEDURES Installation should be performed by competent technicians in accordance with local and state codes. In the absence of these codes, the installation must conform to applicable NA TIONAL ELECTRICAL CODE ANSI/ NFP A NO. 70-LA TEST EDITION, or in Canada, the CANADIAN ELECTRICAL CODES P AR TS 1 & 2 CSA C22.1-1[...]
-
Pagina 13
9 2. Reassembly Instructions For Dryers Shipped In Three (3) Pieces When the dryer is shipped in three (3) pieces, the tumbler (basket) and the tumbler (basket) base sections are shipped as two (2) separate pieces. The heat console section is shipped as the third piece. a. Reassemble The T umbler (Basket) Base Section T o The Heat Console Section M[...]
-
Pagina 14
10 c. Reassemble The T umbler (Basket) Section T o The T umbler (Basket) Base Lift the tumbler (basket) section with a cable through the eye bolts on top of the section. Slowly lower the tumbler (basket) section over the tumbler (basket) base. The four (4) large slots located on the bottom of the tumbler (basket) section (one slot at each corner of[...]
-
Pagina 15
11 B. LOCA TION REQUIREMENTS The model ADS-464 dryer requires 36-inches (99 cm) of space on each side of the dryer and 36-inches (99 cm) of space behind the unit for ease of maintenance and tilting. The dryer must be leveled for proper operation. If shimming is required, put 9-1/2 x 9-1/2 (24 cm x 24 cm) metal shims under the base feet. The d[...]
-
Pagina 16
12 C. INTERNAL AIR, ELECTRICAL , and W A TER CONNECTIONS 1. Air a . Front T ilt Piston and Sprinkler Lines This connection is made at the front of the dryer in the area between the lower heat console section and the tumbler (basket) base section. T o connect the sprinkler air line insert the 1/4 aluminum tubing into the 1/4 brass compression [...]
-
Pagina 17
13 c . LOAD Door Piston Air Lines and Cool Down Damper Piston Air Lines The LOAD door cylinder pneumatic connections are made in the lower heat console section, in the area behind the pneumatic panel. T o connect the 1/4 poly-flo lines into the corresponding needle valves, match the number on the line with the number on the needle valve. Insert [...]
-
Pagina 18
14 2. Electric a. T umbler (Basket) Motors The disconnects for the two (2) tumbler (basket) motors are located in the lower heat console. The right drum (tumbler/basket) motor disconnect is located in the lower heat console on the upper shelf towards the left. The left drum (tumbler/basket) motor disconnect is located in the base of the lower heat [...]
-
Pagina 19
15 c . Annunciator , Pendent, Over-Burner , and R TD (Resistive T emperature Device) Cable Remove the four (4) bolts that hold on the character (464) panel. Open the door to the main electrical enclosure, the female end of the R TD (Resistive T emperature Device) cable will be found there. Loosen the 1-inch (2.54 cm) lock nut and remove the modifie[...]
-
Pagina 20
16 d. Pendant On the top of the heat console section of the dryer near the pendant, there is a junction box with four (4) cables coming out of it. T wo (2) of the cables from the junction box have connectors on the end, a 5-pin connector and an 1 1-pin connector . Coming out of the pendant should be two (2) cables, one with a 5- pin connector and t[...]
-
Pagina 21
17 e . T umbler (Basket) Junction Box Disconnect Remove the four (4) bolts that hold on the lower left side panel, then remove the panel. Next, remove the safety panel by removing the six (6) bolts on the bottom of the panel where the tumbler (basket) section and the base meet. Reach into the feed through hole in the base of the tumbler (basket) se[...]
-
Pagina 22
18 D. EXTERNAL SUPPL Y CONNECTIONS 1. Sprinkler W ater Supply A 40 PSI (276 kPa) supply of water must be connected into the 1 N.P .T . sprinkler connection located on the left side of the tumbler (basket) base. 2. Compressed Air Supply A minimum of 20 cfh (cubic feet per hour) - 0.57 cmh - at 80 PSI (552 kPa) of dry , clean, and regulated compre[...]
-
Pagina 23
19 3. Steam Supply and Condensate Return Connections The steam supply into the dryer is made into the 2-1/2 F .T .P . pipe fitting located on top of the heat module console. The maximum operating steam supply pressure is 150 psig (1,034 kPa). The presence of condensate in the steam supply will cause water hammer and subsequent steam coil (batter[...]
-
Pagina 24
20 4. Exhaust Ducting The dryer s exhaust air must be vented to the outdoors by the shortest route possible with the number of elbows kept to a minimum. The duct should be designed and installed by qualified technicians. Improperly designed duct work may reduce the airflow through the dryer , causing improper and unsafe drying conditions. The s[...]
-
Pagina 25
21 The duct work must be smooth on the inside with no projections from sheet metal screws or other obstructions which would collect lint. Inspection doors must be installed at strategic points in the duct work for periodic lint removal. Use smooth sweeping elbows instead of sharp 90º elbows. The radius of an elbow should be at least 1-1/2 times th[...]
-
Pagina 26
22 E. ELECTRICAL REQUIREMENTS 1. Electrical Requirements It is your responsibility to have ALL electrical connections made by a properly licensed and competent electrician to assure that the electrical installation is adequate and conforms with local and state regulations or codes. In the absence of such codes, ALL electric connections, materials a[...]
-
Pagina 27
23 2. Electrical Service Specifications IMPOR T ANT : The dryer must be connected to the electric supply shown on the data label that is affixed to the right side of the main electrical enclosure. In the case of 208 V AC or 240 V AC, the supply voltage must match the electric service specifications of the data label exactly . W ARNING: 208 V AC and[...]
-
Pagina 28
24 3. Electrical Service The electrical power is connected to the dryer at the high voltage section of the control cabinet. On the ADS-464 dryer , this section is located at the bottom left of the main electrical enclosure. The ADS-464 dryer , with sprinkler option, must be supplied with two (2) independent input power lines. One is 3-phase (3ø) e[...]
-
Pagina 29
25 F . FRESH AIR SUPPL Y REQUIREMENTS When the dryer is operating, it draws in room air , heats this air through the tumbler (basket), and exhausts it out of the building. Therefore, the room air must be continually replenished from the outdoors. If make-up air is inadequate, drying time and efficiency will be adversely affected, and safety will be[...]
-
Pagina 30
26 G . STEAM INFORMA TION It is your responsibility to have ALL plumbing connections made by a qualified professional to assure that the steam plumbing installation is adequate and conforms with local and state regulations or codes. IMPOR T ANT : Failure to comply with the requirements stipulated in this manual can result in component failure which[...]
-
Pagina 31
27 c . Flexible hoses or couplings must be used. The dryer vibrates slightly when it runs and this will cause the steam coil connections to crack if they are hard piped to the supply and return mains. e . A 3/4 vacuum breaker should be installed for each unit in the piping. This will prevent the condensing steam from causing a vacuum inside the [...]
-
Pagina 32
28 SECTION IV PRE ST AR T -UP A. PREP ARA TION FOR OPERA TION 1. The supply voltage must match the dryer voltage as stated on the aluminum dryer data label which is located on the inner right wall of the electrical cabinet. 2. A separate fused power supply must be connected into safety sprinkler circuit power connection. 3. Open ALL steam supply li[...]
-
Pagina 33
29 SECTION V ROUTINE MAINTENANCE A. CLEANING A program or schedule should be established for periodic inspection, cleaning, and removal of lint from various areas of the dryer , as well as throughout the duct work system. The frequency of this cleaning can best be determined from experience at each location. Maximum operating efficiency is dependen[...]
-
Pagina 34
30 MONTHL Y Grease the four (4) tumbler (basket) shaft pillow bearings with DC-44 ( Dow Corning) grease or equivalent. DC-44 is a lithium grease that conforms to NLGI Grade 2 and has a temperature range of 40º F (4.4º C) to 400º F (204.4º C). Empty the compressed air filter bowl. EVER Y 90 DA YS Clean any lint accumulation on main blower wheel.[...]
-
Pagina 35
31 SECTION VI COMPONENT SYSTEM DESCRIPTIONS A. TUMBLER (BASKET) SUPPOR T and DRIVE SYSTEM IMPOR T ANT : Always keep the tumbler (basket) section of the dryer in an upright position when moving it. 1. T umbler (Basket) The tumbler (basket) is made of five (5) 14-gauge stainless steel perforated panels, five (5) stainless steel lifting ribs, and two [...]
-
Pagina 36
32 3. T umbler and Basket Drive System There are two (2) 5 HP (3.73 kw) tumbler (basket) drive motors. Each motor drives one of the 2-inch (5.08 cm) diameter tumbler (basket) drive shafts, and the motors spin simultaneously so that ALL four (4) sets drive wheels work together to spin the tumbler (basket). Each motor is connected to the drive shaft [...]
-
Pagina 37
33 1) Front Panel Electrical Connections: a ) Front Position Switch Disconnect Plug; The front door position switch disconnect plug is located on the left side of the front doors. Disconnect this plug and feed the cable through the right hand side of the tumbler (basket) section. b) Intake T emperature Probe Disconnect Plug; The intake temperature [...]
-
Pagina 38
34 B. MAIN AIR BLOWER and HEA T RECLAIMER SYSTEM The fan which moves the exhaust air through the AD-464 dryer is a 22-inch (56 cm) diameter , squirrel cage wheel that is driven at 1,100 rpm by a 25 HP (18.64 kw) motor . This fan moves a maximum of 13,000 cfm (368 cmm) air through the dryer .[...]
-
Pagina 39
35 The dryer is equipped with a pneumatically operated heat reclaimer damper , which when opened, will recirculate approximately fifteen percent (15%) of the dryer s exhaust air . The heat reclaimer damper is closed until ignition of flame has been established. Then, the damper piston is actuated, opening the dampers recirculating fifteen perce[...]
-
Pagina 40
36 C. COMPRESSED AIR SYSTEM The compressed air system of the ADS-464 dryer consists of a number of pneumatic pistons located throughout the dryer , a Filter Regulator assembly , and pneumatic control panel. 1. Air Pistons The pistons are actuated by solenoid and flow control valves that are under computer control. The pneumatic pistons are used to:[...]
-
Pagina 41
37 The tilting piston valves are 3-position valves. This means that, if no voltage is applied to both positions S5 and S8 ALL five (5) valve ports are blocked. If the dryer is tilting or leveling and power to the dryer is shut off, the pistons will lock in position, holding the dryer in a partially tilted position. The dryer can be made[...]
-
Pagina 42
38 A valve can easily be checked for internal or external piloting by removing the two (2) screws which hold the solenoid operator onto the valve. For an internal pilot air to be supplied to the valve spool. For an external pilot, the solid sealing disc must be positioned on top of the internal port. 5. Loading Doors and Heat Reclaimer , Cool Down [...]
-
Pagina 43
39 S AFETY D EVICES L OC A T ION F UNCTI O N C O MPUTER D IS PLAY M ESSA GE R ESULT O F T RIPPING L OAD D OOR S WITCH L EFT S IDE O F L OAD D OOR I NSURES DRYER LOAD DOOR ARE CLOSED "DOOR OPEN" D RYER WILL NOT R UN U NLOAD DOO R SWI TC H (T WO DOOR UNI T ONLY ) R IGHT S IDE OF UNLOAD DOOR I NSU RES DRYE R UNLOAD DOORS ARE CLO SED "DO[...]
-
Pagina 44
40 SECTION VII SER VICE/P AR TS INFORMA TION A. SER VICE 1. Service must be performed by a qualified trained technician, service agency or gas supplier . If service is required, contact the distributor from whom the ADC equipment was purchased. If the distributor cannot be contacted or is unknown, contact the ADC Service Department for a distributo[...]
-
Pagina 45
41 SECTION VIII W ARRANTY INFORMA TION A. RETURNING W ARRANTY CARDS 1. Before any dryer leaves the ADC factory test area, a warranty card is placed on the back side of the main door glass. These warranty cards are intended to serve the customer where we record the individual installation date and warranty information to better serve you, if you fil[...]
-
Pagina 46
42 d. Date of part failure. e . Specify whether the parts being returned is for a replacement, a credit, or a refund. NOTE: If a part is marked for a credit or a refund, the invoice number covering the purchase of the replacement part must be provided. NOTE: W arranty tags (ADC Part No. 450064) are available at no charge from ADC upon request[...]
-
Pagina 47
43 SECTION IX TROUBLESHOOTING IMPOR T ANT : YOU MUST DISCONNECT and LOCKOUT THE ELECTRICAL SUPPL Y and THE STEAM SUPPL Y BEFORE ANY COVERS or GUARDS ARE REMOVED FROM THE MACHINE T O ALLOW ACCESS FOR CLEANING , ADJUSTING , INST ALLA TION or TESTING O F ANY EQUIPMENT per OSHA (Occupational Safety and Health Administration) ST ANDARDS. The information[...]
-
Pagina 48
44 A. POWER MALFUNCTIONS 1. Main Disconnect W ill Not T urn On a. PROBABLE CAUSES; 1) Sprinkler isolated power source OFF or disabled. 2) OL12 tripped or sprinkler circuit defective. 3) Sprinkler activated. 4) Sprinkler will not reset. b. POSSIBLE SOLUTIONS; 1) V erify red Sprinkler Power on main panel to be illuminated. If ?[...]
-
Pagina 49
45 If R TD (Resistive T emperature Device) probe is defective, replace the probe. NOTE: If ALL systems check out fine, call the ADC Service Department at (508) 678-9000. 2. No Control Power (Blue Light Off) a. PROBABLE CAUSES; 1) Line voltage from main fuse disconnected. 2) Main disconnect on the dryer is turned off. 3) OL1 1 (overload #1[...]
-
Pagina 50
46 3. Machine Main Power Shuts Down (Blue Indicator Off) a. PROBABLE CAUSES; 1) Sprinkler activated. 2) OL12 (overload #12) tripped. 3) UNDER VOL T AGE FEA TURE of main disconnect has tripped. 4) Sprinkler circuit defective. b. POSSIBLE SOLUTIONS; 1) Check if the sprinkler is activated, is SPRINKLER RESET button lit? Is the sprink[...]
-
Pagina 51
47 The following information will first describe the sprinkler circuit components and then provide a circuit description. Please refer to the ADS-464 ladder diagram (which is supplied with the machine) as the following is described. SPRINKLER CIRCUIT COMPONENTS OL12 (overload #12) is a 1.6-amp magnetic and thermal overload device set 1-amp. Its[...]
-
Pagina 52
48 L4 (light #4) is an amber light associated with PB #10 (push button #10), the SPRINKLER RESET button. These items are located on the electrical enclosure s front panel. L4 s function is to give a visual indication that the sprinkler function is asserted and that the pneumatically activated water valve is open. The air a[...]
-
Pagina 53
49 SUMMAR Y : W ith UV (under voltage control of the main disconnect) ener gized, the ADS-464 main switch may be turned on. ST A TE 2 - The tumbler (basket) temperature has risen ABOVE SHLC (Sprinkler High Limit Controller) preset trip value. W ith power applied to the SHLC: SHLC set point will open SHLC alarm will close #2CR [...]
-
Pagina 54
50 4. Front Panel BLUE Light and RED Light ON ADS-464 ON button does respond ... a. PROBABLE CAUSES; 1) EMERGENCY STOP (E-Stop) BUTTONS 1, 2, and 3. b. POSSIBLE SOLUTIONS; 1) V erify that ALL EMERGENCY STO P (E-Stop) buttons are pushed in. EMERGENCY STOP 1 - main enclosed door EMERGENCY STOP 2 - p[...]
-
Pagina 55
51 3) Malfunctioning operator interface terminal or communications cable. 4) Malfunctioning 24 volt DC power supply . 5) Malfunctioning hi-limit temperature controller . b. POSSIBLE SOLUTIONS; 1) V erify that fuses 7, 8, 9, and 10 are good. Check that ALL fuse holder L.E.D. (light emitting diode) indicators are not lit. If ALL fuses are good, g[...]
-
Pagina 56
52 General Description: The six (6) channels accept independent R TD (Resistive T emperature Device) inputs (spare channels have a 100 ohm [100 W ] 5% tolerance resistors installed) and there is an individual set point for each channel. In operation, the scan rate between channels is four (4) to six (6) seconds, and the display will have the temper[...]
-
Pagina 57
53 If anyone of the HI-LIMIT temperature SENSORS sense an over temperature condition. It will open its control relay . (Refer to the ADS-464 ladder diagram for the ef fect of this relay .) If a HI-TEMP F AUL T message is displayed, open the main electrical enclosure, and notice which channel has cycled. This will lead one in the direc[...]
-
Pagina 58
54 Check that ALL EMERGENCY STOP (E-S top) buttons are disengaged (out). Check fuse 10 s blown fuse indicator . Check wiring; refer to ADS-464 Main Panel W iring Diagram. Retest. 7 DRUM F AUL T Message PLC (PROGRAMMABLE LOGIC CONTROLLER) MESSAGE DRUM F AUL T a. PROBABLE CAUSE; 1) Stop motion detector module or s[...]
-
Pagina 59
55 Circuit wiring; refer to ADS-464 main panel wiring diagram ADS-464 tumbler (basket) junction box wiring diagram. B. TUMBLER (BASKET) SECTION ELECTRICAL MALFUNCTIONS INTRODUCTION There are a number of electrical components associated with the ADS-464 tumbler (basket) section. These components are ALL interfaced to the tumbler (basket) junctio[...]
-
Pagina 60
56 c . Drum Rotation Sensor - PRS1 The drum rotation sensor is an inductive pick up device located on the left wrapper of the tumbler (basket) section. Its function is to sense a metal target attached to the basket as it rotates. The mechanical adjustment of this device, (distance from the target) is crucial (3/16 from target). CAUTI[...]
-
Pagina 61
57 2.0. Rear Panel Control Problems EMERGENCY STOP (E-Stop) Function a. PROBABLE CAUSES: 1) Rear panel disconnect plug 2) Defective switch 3) W iring back to the main electrical enclosure b. POSSIBLE SOLUTIONS; 1) If the EMERGENCY STOP (E-Stop) - rear - does not respond: V erify that ALL other EMERGENCY STOP (E-S top) buttons [...]
-
Pagina 62
58 3b ) W iring from the EMERGENCY STOP (E-Stop) button to the main electrical enclosure is faulty or incorrect. Check REAR P ANEL CONTROLS WIRING DIAGRAM Check TUMBLER JUNCTION BOX WIRING DIAGRAM Refer to section #3 on page 57 and retest Drum Forward and Reverse Function c. PROBABLE CAUSES; 1) Rear panel disconnect plug 2) Defect[...]
-
Pagina 63
59 3a) The L.E.D. s illuminating on the PLC (Programmable Logic Controller) indicate that the wiring to the PLC is correct. Check that the respective outputs of the PLC are also illuminating when the FOR W ARD and REVERSE buttons are being pressed. PLC OUT PIN 1 = DRUM REVERSE PLC OUT PIN 2 = DRUM FOR W ARD If output indicators are funct[...]
-
Pagina 64
60 Shut power off at the main breaker and remove the rear panel and check switches using an OHM meter; replace if defective 3) W iring back to the main electrical enclosure With the control voltage ON Front Panel green Button Select 1 on the O UNLOAD switch located on the rear control panel. Does PLC (Programmabl[...]
-
Pagina 65
61 3. 0 DOOR Open Problem A DOOR OPEN message is generated by either the heater , the LOAD doors, or UNLOAD doors. The following information will address the LOAD doors and the UNLOAD doors signals, since they are associated with the tumbler (basket) junction box. a. PROBABLE CAUSES; 1) WIRING BACK THE PLC (Programmable Logic Controller[...]
-
Pagina 66
62 Retest; verify that the signal is operational 4. 0 DRUM F AUL T MESSAGE Malfunction a. PROBABLE CAUSES; 1) Stop Motion Detector module or sensor 2) W iring back to main electrical enclosure b. PROBABLE SOLUTIONS; 1) Open the Main Electrical Enclosure locate input #0, 10 on the PLC (Programmable Logic Controller). W ith control voltage [...]
-
Pagina 67
63 T umbler (basket) target...this tar get is attached to the outside of the basket Stop motion detector module in the tumbler (basket) section on the left front side Circuit W iring; refer to ADS-464 Main Panel W iring Diagram ADS-464 T umbler (Basket) Junction Box W iring Diagram C. BASE SECTION ELECTRICAL MALFUNCTIONS INTRODUCTIO[...]
-
Pagina 68
64 c . Lint Drawer Proximity Switches The Lint Drawer Proximity Switches are located on the left side of the ADS-464 base, and is comprised of six (6) parts: Junction Box, two (2) proximity switches, and three (3) cord grip switches. The switches sense a magnet installed on the lint drawer that verify that ALL safeties are met to the Burner C[...]
-
Pagina 69
65 Check switch and actuator placement and tilt actuation. NOTE: If actuator is at a 90º or greater angle with the base, actuator will be damaged if machine is lowered. If NO, check associated: Switch and W iring Check wiring back to the base electrical junction box Check PLC (Programmable Logic Controller) Refer to t[...]
-
Pagina 70
66 a. PROBABLE CAUSES 1) The lint screen must be cleaned every five (5) drying cycles 2) W iring back to the PLC (Programmable Logic Controller), 0, 8 3) Clogged lint screen or lint bag 4) Air pressure setting 5) Air pressure switch - PS3 or wiring back to the PLC (Programmable Logic Controller) b. PROBABLE SOLUTIONS; 1) Perform preventive maintena[...]
-
Pagina 71
67 D. PENDANT CONTROL MALFUNCTIONS INTRODUCTION There are four (4) electrical switches associated with the ADS-464 Pendant Assembly . These components are interfaced to TB1 of Main Electrical Enclosure through two (2) disconnects and two (2) junction boxes. The Pendant Assembly is remote control for Loading or Unloading the ADS-464. The functions p[...]
-
Pagina 72
68 TUMBLER FOR W ARD PENDANT --- PB1 This push button comprises of one (1) normally open switch, and is mechanically interlock with T umbler Reverse Push Button. EMERGENCY STOP (E-Stop) PENDANT --- PB6 This push button switch is normally an open device and its function is to shut down the control voltage to the dryer in th[...]
-
Pagina 73
69 Release the REVERSE Push-button Does PLC (Programmable Logic Controller) input L.E.D. #18 go OFF? If the answers to these questions are YES, wiring to the PLC is correct. If any answer to these questions is NO, refer to Probable Causes below T umbler Forward Switch --- PB1 For quick check of the wiring of PB[...]
-
Pagina 74
70 EMERGENCY STOP (E-Stop) SWITCH --- PB6 If the EMERGENCY STOP (E-Stop) switch (pendant) does not respond: c. PROBABLE CAUSES; 1) ANOTHER EMERGENCY STOP (E-Stop) BUTTON 2 ) A DISCONNECT PLUG 3 ) F AUL TY SWITCH 4 ) WIRING BACK TO TB1 d. POSSIBLE SOLUTIONS; 1) V erify that ALL other EMERGENCY STOP (E-Stop) buttons are no[...]
-
Pagina 75
71 1. TEMPERA TURE SENSING COMPONENT DESCRIPTIONS Exhaust R TD (Resistive T emperature Device) - Sens1 The R TD (Resistive T emperature Device), used throughout the ADS-464 are identical. The main function is to measure temperatures and to transfer this information to a measuring device for further processing. The R TD used on the ADS-464 are r[...]
-
Pagina 76
72 3) Defective Analog Input Module For Channel 4) R TD (Resistive T emperature Device) W iring T o The EXHAUST 4 to 20 milliamphere (4 to 20 mA) T ransmitter 5) Circuit W iring T o the Analog Input Module b. POSSIBLE SOLUTIONS; 1) W ith the control voltage OFF The exhaust R TD (Resistive T emperature Device) probe can be quickly checke[...]
-
Pagina 77
73 4. R TD (Resistive T emperature Device) WIRING T O THE EXHAUST 4 to 20 MILLIAMPERE (4 to 20 mA) TRANSMITTER Check ALL wiring and ADS-464 connection from the exhaust R TD (Resistive T emperature Device) probe to the exhaust 4 to 20 milliampere (4 to 20 mA) transmitter . Refer to the ADS-464 EXHAUST T emperature Assembly and W iring Diagram,[...]
-
Pagina 78
74 2) PLC (Programmable Logic Controller) Output Signal Defective 3) Motor Circuit W iring b. PROBABLE SOLUTIONS; 1) V erify that ALL motor protection devices (manual starters) have their ST AR T buttons pushed in. If any device has tripped, reset it and restart the dryer . If the same devices continue to trip: V erify current setting [...]
-
Pagina 79
75 G . PLC (Programmable Logic Controller) ERROR MESSAGES The ADS-464 diagnostics messages have been provides to aid troubleshooters in diagnosing and repairing dryer problems. The messages are intended to direct one to a particular fault area for further testing; not to diagnose the machine for you. NOTE: Not ALL ADS-464 dryer symptoms have faults[...]
-