Vai alla pagina of
Manuali d’uso simili
-
Automobile Alarm
Directed Electronics Matrix1X
51 pagine 1.16 mb -
Automobile Alarm
Directed Electronics 5701
56 pagine 3.54 mb -
Automobile Alarm
Directed Electronics 730T
28 pagine 0.3 mb -
Automobile Alarm
Directed Electronics 460MAX
40 pagine 1.34 mb -
Automobile Alarm
Directed Electronics 881XP
57 pagine 0.92 mb -
Automobile Alarm
Directed Electronics RS2.1
45 pagine 0.78 mb -
Automobile Alarm
Directed Electronics 320.3X
41 pagine 0.42 mb -
Automobile Alarm
Directed Electronics 600 ESP
36 pagine 0.47 mb
Un buon manuale d’uso
Le regole impongono al rivenditore l'obbligo di fornire all'acquirente, insieme alle merci, il manuale d’uso Directed Electronics 417. La mancanza del manuale d’uso o le informazioni errate fornite al consumatore sono la base di una denuncia in caso di inosservanza del dispositivo con il contratto. Secondo la legge, l’inclusione del manuale d’uso in una forma diversa da quella cartacea è permessa, che viene spesso utilizzato recentemente, includendo una forma grafica o elettronica Directed Electronics 417 o video didattici per gli utenti. La condizione è il suo carattere leggibile e comprensibile.
Che cosa è il manuale d’uso?
La parola deriva dal latino "instructio", cioè organizzare. Così, il manuale d’uso Directed Electronics 417 descrive le fasi del procedimento. Lo scopo del manuale d’uso è istruire, facilitare lo avviamento, l'uso di attrezzature o l’esecuzione di determinate azioni. Il manuale è una raccolta di informazioni sull'oggetto/servizio, un suggerimento.
Purtroppo, pochi utenti prendono il tempo di leggere il manuale d’uso, e un buono manuale non solo permette di conoscere una serie di funzionalità aggiuntive del dispositivo acquistato, ma anche evitare la maggioranza dei guasti.
Quindi cosa dovrebbe contenere il manuale perfetto?
Innanzitutto, il manuale d’uso Directed Electronics 417 dovrebbe contenere:
- informazioni sui dati tecnici del dispositivo Directed Electronics 417
- nome del fabbricante e anno di fabbricazione Directed Electronics 417
- istruzioni per l'uso, la regolazione e la manutenzione delle attrezzature Directed Electronics 417
- segnaletica di sicurezza e certificati che confermano la conformità con le norme pertinenti
Perché non leggiamo i manuali d’uso?
Generalmente questo è dovuto alla mancanza di tempo e certezza per quanto riguarda la funzionalità specifica delle attrezzature acquistate. Purtroppo, la connessione e l’avvio Directed Electronics 417 non sono sufficienti. Questo manuale contiene una serie di linee guida per funzionalità specifiche, la sicurezza, metodi di manutenzione (anche i mezzi che dovrebbero essere usati), eventuali difetti Directed Electronics 417 e modi per risolvere i problemi più comuni durante l'uso. Infine, il manuale contiene le coordinate del servizio Directed Electronics in assenza dell'efficacia delle soluzioni proposte. Attualmente, i manuali d’uso sotto forma di animazioni interessanti e video didattici che sono migliori che la brochure suscitano un interesse considerevole. Questo tipo di manuale permette all'utente di visualizzare tutto il video didattico senza saltare le specifiche e complicate descrizioni tecniche Directed Electronics 417, come nel caso della versione cartacea.
Perché leggere il manuale d’uso?
Prima di tutto, contiene la risposta sulla struttura, le possibilità del dispositivo Directed Electronics 417, l'uso di vari accessori ed una serie di informazioni per sfruttare totalmente tutte le caratteristiche e servizi.
Dopo l'acquisto di successo di attrezzature/dispositivo, prendere un momento per familiarizzare con tutte le parti del manuale d'uso Directed Electronics 417. Attualmente, sono preparati con cura e tradotti per essere comprensibili non solo per gli utenti, ma per svolgere la loro funzione di base di informazioni e di aiuto.
Sommario del manuale d’uso
-
Pagina 1
© 2000 Directed Electr onics , Inc . Vista, CA N417A 9-00 ® Model 417 Installation Guide ® : http://www. guardianalarms . net[...]
-
Pagina 2
2 © 2000 Directed Electr onics , Inc . Vista, CA What Is Included . . . . . . . . . . . . . . . . . . . . . 3 Product Description . . . . . . . . . . . . . . . . . . . 4 Installation P oints to Remember . . . . . . . . . . 4 T ools Required . . . . . . . . . . . . . . . . . . . . . . . 5 Deciding on Component Locations . . . . . . . . . 5 Siren . [...]
-
Pagina 3
© 2000 Directed Electr onics , Inc . Vista, CA 3 what is included ■ The control module (see diagr am) ■ A Rev enger ® Soft Chirp ® siren ■ The plug-in V alet ® /progr am switch ■ The plug-in status LED ■ 12-Pin primary harness ■ Starter kill relay pack age ■ A Stinger ® Doubleguard ® shock sensor on-boar d the control module 12-[...]
-
Pagina 4
4 © 2000 Directed Electr onics , Inc . Vista, CA pr oduct description This unit is used to enhance a vehi cle’s original equipm ent from m anufactur er (OEM) factory k eyless entry system by converting it in to a full-featured alarm system. It has been d esigned to work with th e factory tran smitters and to in terface with minimal wirin g to th[...]
-
Pagina 5
© 2000 Directed Electr onics , Inc . Vista, CA 5 AFTER THE INST ALLA TION ■ T est all functi ons. Th e “Using Y our System” secti on of the Own er’s Guide is very h elp ful when testin g. ■ When testin g, don’t for get that this system is equipped with Nuisan ce Preventi on Circuitry (NPC). This cir- cuitry can bypass both instan t tri[...]
-
Pagina 6
6 © 2000 Directed Electr onics , Inc . Vista, CA ■ P oint the sir en down so water does n ot collect in it. ■ Never put th e control m odule in the en gine compartmen t! ■ The first step in h ot-wiring a vehicle is r emoving th e driver's sid e under d ash panel to access th e starter and igniti on wires. If th e control m odule is plac[...]
-
Pagina 7
© 2000 Directed Electr onics , Inc . Vista, CA 7 This system has Remote V alet, so the user can en ter and exit V alet Mod e without having to r each th e V alet/program switch. DEI in trodu ced this feature so that switch location was less criti cal in day-to-day use . A s long as th e Valet/pr ogram switch can be reach ed to disarm without a tra[...]
-
Pagina 8
8 © 2000 Directed Electr onics , Inc . Vista, CA If the Failsafe ® Starter Kill Relay or its conn ections ar e immediately visible upon r emoval of th e under d ash panel, they can easily be bypassed by a thi ef. Always make th e relay and its conn ections diffi cult to discern from the factory wirin g! Exposed yellow butt connectors do n ot look[...]
-
Pagina 9
© 2000 Directed Electr onics , Inc . Vista, CA 9 How to find (+)12V ignition with y our multimeter: 1. Set to DCV or DC voltage (12V or 20V is fine). 2. Attach the (-) pr obe o f the m eter to chassis ground . 3. Probe the wir e you suspect o f being th e ignition wir e . The steerin g column harness (i gnition switch harness) is an e xcellent pla[...]
-
Pagina 10
10 © 2000 Directed Electr onics , Inc . Vista, CA making y our connections When conn ecting the security system’s wir es to the vehicle wir es it is important that the conn ections ar e ti ght and n o bare wire is e xposed. In this section, two types o f connection s are described that m ay be used to conn ect the wir es from the security system[...]
-
Pagina 11
© 2000 Directed Electr onics , Inc . Vista, CA 11 1. Using your wir e strippers an d razor knife , strip appro xim ately 1 / 2 -inch o f insulation o ff the wire to be con- nected to, with out cutting the wir e. 2. Twist th e security m odule’s wir e around th e bar e section o f the vehicle’s wir e. 3. Solder the bar e conn ection th oroughly[...]
-
Pagina 12
12 © 2000 Directed Electr onics , Inc . Vista, CA primary harness (H1) wir e connection guide This section o f the installati on guide d escribes in detail the conn ection of each o f th e primary harn ess wires. Also inclu ded are possible appli cations o f each wire . This system was design ed with th e ultimate in fle xibility and security in m[...]
-
Pagina 13
© 2000 Directed Electr onics , Inc . Vista, CA 13 IMPORT ANT! Never interrupt any wire other than the starter wire. NOTE: If connecting the H1/1 wire to control another module, such as a window controller ( P/N 529T or 530T ), a 1 amp diode (type 1N4004) will be required. Insert the diode as shown in the following diagram. H1/2 WHITE (-/+) SELECT [...]
-
Pagina 14
14 © 2000 Directed Electr onics , Inc . Vista, CA H1/3 WHITE/BLUE (+) TRUNK RELEASE, SENSOR SHUNT INPUT This input is used to bypass sensor inputs wh en the trunk is opened usin g the factory tr ansmitter . Connect this wire to th e (+) trunk release output of th e factory keyless en try system or trunk release relay . When th e system receives a [...]
-
Pagina 15
© 2000 Directed Electr onics , Inc . Vista, CA 15 H1/6 BLUE (-) INST ANT TRIGGER, ZONE 1 This input will respon d to a negative input with an instan t trigger . It is i deal for h ood and trunk pins or vehi- cles without f actory Content Th eft Deterrent (CTD). V ehicles with out CTD may requir e trunk pin s or need to be hard-wir ed to the alarm.[...]
-
Pagina 16
16 © 2000 Directed Electr onics , Inc . Vista, CA H1/10 BROWN (+) SIREN OUTPUT Connect this wir e to the red wir e of the sir en. Connect the black wir e of the sir en to (-) chassis gr ound , prefer- ably at the sam e point that you connect th e control m odule’s black groun d wire . H1/11 RED (+) 12V CONST ANT POWER INPUT Befor e connecting th[...]
-
Pagina 17
© 2000 Directed Electr onics , Inc . Vista, CA 17 plug-in harnesses The LED oper ates at 2V DC. Make sur e the LED wires ar e not shorted to gr ound because the LED will be d am aged . The LED fits in to a 9 / 32 -in ch moun ting hole . Be sure to ch eck for clearan ce pri or to drillin g the moun ting hole . The V alet/progr am switch should be a[...]
-
Pagina 18
18 © 2000 Directed Electr onics , Inc . Vista, CA oper ation mode settings ARMING AND DISARMING WITH THE OEM TRANSMITTER When conn ected to the vehicle’s d atabus, the in terface mod ule can be armed and disarm ed with th e OEM keyless en try tran smitter by pressing th e lock and unlock buttons , respectively . SENSOR SHUNT AND TRUNK TRIGGER BY[...]
-
Pagina 19
© 2000 Directed Electr onics , Inc . Vista, CA 19 NOTE: Factory content theft deterrent (CTD) systems in Bonnevilles, A uroras and LeSabres do not monitor the trunk key cylinder wire; theref ore, the trunk k ey cylinder sensor bypass feature is not available on these vehicles. The alarm will trigger if the f actory trunk release feature on the OEM[...]
-
Pagina 20
20 © 2000 Directed Electr onics , Inc . Vista, CA internal pr ogr amming jumper s T o access the jumper , open the con trol mod ule. This jumper is used to d etermine the li ght flash output. In the def ault negative (-) position, th e on-board relay is disabled an d the unit will output (-) 200 mA, suitable for drivin g factory parking li ght rel[...]
-
Pagina 21
© 2000 Directed Electr onics , Inc . Vista, CA 21 LEVEL II SECURITY MODE When this jumper is m oved to the Level II position, th e databus interf ace module will n ot disarm from the d river’s door or passen ger door k ey cylinder . The trunk tri gger zone will sh unt if opened usin g the tran smitter but will trigg er when the k ey is used or i[...]
-
Pagina 22
22 © 2000 Directed Electr onics , Inc . Vista, CA s y stem featur es learn r outine The System Featur es Learn Routine dictates h ow the unit operates . It is possible to access and chan ge any o f th e feature settin gs using the V alet/progr am switch. T o enter the System F eatures Learn Routine: 1. Open a door . 2. Key . T urn the igniti on on[...]
-
Pagina 23
© 2000 Directed Electr onics , Inc . Vista, CA 23 5. Release the V alet/progr am switch. ONCE THE FEA TURE IS PROGRAMMED ■ Other featur es can be programm ed. ■ The Learn Routin e can be exited if progr amming is complete . TO A CCESS ANOTHER FEA TURE After you have progr ammed a feature in Step 4 o f the learn routin e, pr ess and release th [...]
-
Pagina 24
24 © 2000 Directed Electr onics , Inc . Vista, CA 4 DOOR TRIGGER INST ANT/DELA YED: In the in stant (def ault) setting, if a door is open ed while the security system is armed th e system will trigger imm ediately . In the delayed settin g there is a 15-secon d delay befor e the doors will tri gger the system. This allows th e user 15 seconds to d[...]
-
Pagina 25
© 2000 Directed Electr onics , Inc . Vista, CA 25 table o f zones When usin g the diagn ostic functi ons, use th e T able of Zon es to d etermine whi ch input has trigger ed the system. It is also h elpful in deci ding which input to use wh en connecting opti onal sensors an d switch es. tr oubleshooting ■ Starter kill does not work: Is th e cor[...]
-
Pagina 26
26 © 2000 Directed Electr onics , Inc . Vista, CA ■ Closing the door triggers the s ystem, but opening the door does not: Have you corr ectly iden tified the type o f door switch system? This often happen s when the wr on g door input has been used. (See th e Finding the Wires You Need, Door Pin Switch Circuit secti on of this guid e.) ■ Syste[...]
-
Pagina 27