Empire Comfort Systems FAW-55SPP manuale d’uso
- Visualizza on-line o scarica il manuale
- 12 pagine
- 0.82 mb
Vai alla pagina of
Manuali d’uso simili
-
Furnace
Empire Comfort Systems DV-55SPP
20 pagine 0.69 mb -
Furnace
Empire Comfort Systems FAW-40-1SPP
36 pagine 0.94 mb -
Furnace
Empire Comfort Systems DV-55E-5
20 pagine 1.01 mb -
Furnace
Empire Comfort Systems FAW-40-1SPP
18 pagine 0.74 mb -
Furnace
Empire Comfort Systems DV-55T-1
20 pagine 0.92 mb -
Furnace
Empire Comfort Systems 7088-3
12 pagine 0.17 mb -
Furnace
Empire Comfort Systems 3588-3
12 pagine 0.17 mb -
Furnace
Empire Comfort Systems GWT-50-2
20 pagine 1.11 mb
Un buon manuale d’uso
Le regole impongono al rivenditore l'obbligo di fornire all'acquirente, insieme alle merci, il manuale d’uso Empire Comfort Systems FAW-55SPP. La mancanza del manuale d’uso o le informazioni errate fornite al consumatore sono la base di una denuncia in caso di inosservanza del dispositivo con il contratto. Secondo la legge, l’inclusione del manuale d’uso in una forma diversa da quella cartacea è permessa, che viene spesso utilizzato recentemente, includendo una forma grafica o elettronica Empire Comfort Systems FAW-55SPP o video didattici per gli utenti. La condizione è il suo carattere leggibile e comprensibile.
Che cosa è il manuale d’uso?
La parola deriva dal latino "instructio", cioè organizzare. Così, il manuale d’uso Empire Comfort Systems FAW-55SPP descrive le fasi del procedimento. Lo scopo del manuale d’uso è istruire, facilitare lo avviamento, l'uso di attrezzature o l’esecuzione di determinate azioni. Il manuale è una raccolta di informazioni sull'oggetto/servizio, un suggerimento.
Purtroppo, pochi utenti prendono il tempo di leggere il manuale d’uso, e un buono manuale non solo permette di conoscere una serie di funzionalità aggiuntive del dispositivo acquistato, ma anche evitare la maggioranza dei guasti.
Quindi cosa dovrebbe contenere il manuale perfetto?
Innanzitutto, il manuale d’uso Empire Comfort Systems FAW-55SPP dovrebbe contenere:
- informazioni sui dati tecnici del dispositivo Empire Comfort Systems FAW-55SPP
- nome del fabbricante e anno di fabbricazione Empire Comfort Systems FAW-55SPP
- istruzioni per l'uso, la regolazione e la manutenzione delle attrezzature Empire Comfort Systems FAW-55SPP
- segnaletica di sicurezza e certificati che confermano la conformità con le norme pertinenti
Perché non leggiamo i manuali d’uso?
Generalmente questo è dovuto alla mancanza di tempo e certezza per quanto riguarda la funzionalità specifica delle attrezzature acquistate. Purtroppo, la connessione e l’avvio Empire Comfort Systems FAW-55SPP non sono sufficienti. Questo manuale contiene una serie di linee guida per funzionalità specifiche, la sicurezza, metodi di manutenzione (anche i mezzi che dovrebbero essere usati), eventuali difetti Empire Comfort Systems FAW-55SPP e modi per risolvere i problemi più comuni durante l'uso. Infine, il manuale contiene le coordinate del servizio Empire Comfort Systems in assenza dell'efficacia delle soluzioni proposte. Attualmente, i manuali d’uso sotto forma di animazioni interessanti e video didattici che sono migliori che la brochure suscitano un interesse considerevole. Questo tipo di manuale permette all'utente di visualizzare tutto il video didattico senza saltare le specifiche e complicate descrizioni tecniche Empire Comfort Systems FAW-55SPP, come nel caso della versione cartacea.
Perché leggere il manuale d’uso?
Prima di tutto, contiene la risposta sulla struttura, le possibilità del dispositivo Empire Comfort Systems FAW-55SPP, l'uso di vari accessori ed una serie di informazioni per sfruttare totalmente tutte le caratteristiche e servizi.
Dopo l'acquisto di successo di attrezzature/dispositivo, prendere un momento per familiarizzare con tutte le parti del manuale d'uso Empire Comfort Systems FAW-55SPP. Attualmente, sono preparati con cura e tradotti per essere comprensibili non solo per gli utenti, ma per svolgere la loro funzione di base di informazioni e di aiuto.
Sommario del manuale d’uso
-
Pagina 1
12428-3-0706 Page 1 INST ALLA TION INSTRUCTIONS AND OWNER’S MANUAL Installer: Leave these instructions with the consumer . Consumer: Retain these instructions for futur e use. W ARNING: If not installed, operated and main- tained in accordance with the manufacturer’ s instructions, this product could expose you to substances in fuel or from fue[...]
-
Pagina 2
12428-3-0706 Page 2 Introduction Always consult your local Building Department regarding regu- lations or ordinances which apply to the installation of a vented wall furnace. Instructions to Installer 1. Installer must leave instruction manual with owner after instal - lation. 2. Installer must have owner fill out and mail warranty card supplied w[...]
-
Pagina 3
12428-3-0706 Page 3 SAFETY INFORMA TION FOR USERS OF LP-GAS Propane (LP-Gas) is a flammable gas which can cause fir es and explosions. In its natural state, propane is odorless and colorless. Y ou may not know all the following safety precau - tions which can protect both you and your family from an accident. Read them carefully now , then r evie[...]
-
Pagina 4
12428-3-0706 Page 4 V entilation and Combustion Air W all furnaces shall be installed in a location in which the facilities for ventilation permit satisfactory combustion of gas and proper venting under normal conditions. In buildings of conventional frame, brick, or stone construction without tight storm windows and doors, infiltration is normall[...]
-
Pagina 5
12428-3-0706 Page 5 8” x 12” (203mm x 305mm) boot. Remove duct and cut to proper length. 8. Attach 6” x 10” (152mm x 254mm) duct to inner casing with (6) #10 x 1/2” (13mm) screws provided. 9. Insert rear register into 8” x 12” (203mm x 305mm) boot. Attach rear register to wall with (2) #10 x 1” (25mm) screws provided. Locating Furna[...]
-
Pagina 6
12428-3-0706 Page 6 4. Connect nylon cap on 3’ (914mm) plug assembly to nylon plug on the wiring harness. 5. Place 7/8” (22mm) strain relief bushing around the cord of the 3’ (914mm) plug assembly . Insert 7/8” (22mm) strain relief bushing into the 7/8” (22mm) hole in the side panel. Attention! The 7/8” (22mm) strain relief bushing is l[...]
-
Pagina 7
12428-3-0706 Page 7 T o light the pilot, it is important that the electrode be 1/8” (3mm) from the thermocouple. The spark must occur at the point the burner flame hits the thermocouple. The end of the electrode will be red hot with the pilot on. On a new installation with air in the gas line, it is suggested that a match be used. The match will[...]
-
Pagina 8
12428-3-0706 Page 8 V ent Safety Shutoff System This appliance must be properly connected to a venting system. This appliance is equipped with a vent safety shutoff system. This furnace is equipped with a manual reset vent safety switch. The manual reset vent safety switch will cause gas flow to the main burners to “shut off” due to improper v[...]
-
Pagina 9
12428-3-0706 Page 9 FOR YOUR SAFETY READ BEFORE LIGHTING W ARNING: If you do not follow these instructions exactly , a fire or explosion may r esult causing property damage, personal injury or loss of life. A. This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly . B. BEFORE LIGHTING s[...]
-
Pagina 10
12428-3-0706 Page 10 Please Note: When ordering parts, it is very important that part number and description of part coincide. Index No. Part Number Description Index No. Part Number Description 1 WF A-115 BASEPLA TE GASKET 28 DV -687 MANIFOLD AND PLA TE ASSEMBL Y 2 1 1763 OUTER CASING T OP 29 712045 MANIFOLD GASKET 3 632024 MOTOR MOUNT (FOUR REQUI[...]
-
Pagina 11
12428-3-0706 Page 1 1[...]
-
Pagina 12
12428-3-0706 Page 12 Model No. F A W -55 may be vented as shown. The vent cap must be at least 12 feet (3.7m) above the floor . Clearance to combus - tible construction is held by the fixed spacers at 1 inch (25mm) with B-1 vent pipe. Installation must conform to local codes. 4” (102mm) Round (all parts purchase locally except in item 2) 1. T y[...]