Le regole impongono al rivenditore l'obbligo di fornire all'acquirente, insieme alle merci, il manuale d’uso Harman Stove Company P43. La mancanza del manuale d’uso o le informazioni errate fornite al consumatore sono la base di una denuncia in caso di inosservanza del dispositivo con il contratto. Secondo la legge, l’inclusione del manuale d’uso in una forma diversa da quella cartacea è permessa, che viene spesso utilizzato recentemente, includendo una forma grafica o elettronica Harman Stove Company P43 o video didattici per gli utenti. La condizione è il suo carattere leggibile e comprensibile.
Che cosa è il manuale d’uso?
La parola deriva dal latino "instructio", cioè organizzare. Così, il manuale d’uso Harman Stove Company P43 descrive le fasi del procedimento. Lo scopo del manuale d’uso è istruire, facilitare lo avviamento, l'uso di attrezzature o l’esecuzione di determinate azioni. Il manuale è una raccolta di informazioni sull'oggetto/servizio, un suggerimento.
Purtroppo, pochi utenti prendono il tempo di leggere il manuale d’uso, e un buono manuale non solo permette di conoscere una serie di funzionalità aggiuntive del dispositivo acquistato, ma anche evitare la maggioranza dei guasti.
Quindi cosa dovrebbe contenere il manuale perfetto?
Innanzitutto, il manuale d’uso Harman Stove Company P43 dovrebbe contenere:
- informazioni sui dati tecnici del dispositivo Harman Stove Company P43
- nome del fabbricante e anno di fabbricazione Harman Stove Company P43
- istruzioni per l'uso, la regolazione e la manutenzione delle attrezzature Harman Stove Company P43
- segnaletica di sicurezza e certificati che confermano la conformità con le norme pertinenti
Perché non leggiamo i manuali d’uso?
Generalmente questo è dovuto alla mancanza di tempo e certezza per quanto riguarda la funzionalità specifica delle attrezzature acquistate. Purtroppo, la connessione e l’avvio Harman Stove Company P43 non sono sufficienti. Questo manuale contiene una serie di linee guida per funzionalità specifiche, la sicurezza, metodi di manutenzione (anche i mezzi che dovrebbero essere usati), eventuali difetti Harman Stove Company P43 e modi per risolvere i problemi più comuni durante l'uso. Infine, il manuale contiene le coordinate del servizio Harman Stove Company in assenza dell'efficacia delle soluzioni proposte. Attualmente, i manuali d’uso sotto forma di animazioni interessanti e video didattici che sono migliori che la brochure suscitano un interesse considerevole. Questo tipo di manuale permette all'utente di visualizzare tutto il video didattico senza saltare le specifiche e complicate descrizioni tecniche Harman Stove Company P43, come nel caso della versione cartacea.
Perché leggere il manuale d’uso?
Prima di tutto, contiene la risposta sulla struttura, le possibilità del dispositivo Harman Stove Company P43, l'uso di vari accessori ed una serie di informazioni per sfruttare totalmente tutte le caratteristiche e servizi.
Dopo l'acquisto di successo di attrezzature/dispositivo, prendere un momento per familiarizzare con tutte le parti del manuale d'uso Harman Stove Company P43. Attualmente, sono preparati con cura e tradotti per essere comprensibili non solo per gli utenti, ma per svolgere la loro funzione di base di informazioni e di aiuto.
Sommario del manuale d’uso
-
Pagina 1
R1 P43 Pellet Stove Owners Manual SA VE THESE INSTRUCTIONS. Installation & Operating Manual R1 “Ce manuel est disponible en Français sur demande” SAFETY NOTICE PLEASE READ THIS ENTIRE MANUAL BEFORE YOU INST ALL AND USE YOUR NEW ROOM HEA TER. F AILURE TO FOLLOW INSTRUCTIONS MA Y RESUL T IN PROPERTY DAMAGE, BODIL Y INJUR Y , OR EVEN DEA TH. [...]
-
Pagina 2
2 P43 Pellet Stove Harman PP38+/P43 Pellet Stove Label measures: 4-3/8" high X 9-3/4"wide MINIMUM CLEARANCES TO COMBUSTIBLES: SIDEWALL T O STOVE 16" 10" BACKWALL T O STOVE 2" 2" CEILING TO ST OVE TOP 18" 18" STOVE CORNER T O DIAGONAL W ALL 9" 9" PREVENT HOUSE FIRES, OPERA TE WITH VIEWING & ASH D[...]
-
Pagina 3
3 P43 Pellet Stove Safety Information 4 Installation 5 V enting 7 ESP Control 14 Automatic Operation 15 Manual Operation 18 Low Draft V oltage Adjustment 20 Room Sensor 21 Maintenance 22 T rouble Shooting 26 Feeder Parts 27 Specications 28 Options 29 Wiring Diagram 30 Parts List 31 W arranty 32 Ple ase read thi s entir e manual be[...]
-
Pagina 4
4 P43 Pellet Stove DO NOT INST ALL A FLUE DAMPER IN THE EXHAUST VENTING SYSTEM OF THIS UNIT . DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SER VING ANOTHER APPLIANCE. MOBILE HOME INST ALLA TION SHOULD BE DONE IN ACCORDANCE WITH THE MANUF ACTURED HOME AND SAFETY ST ANDARD (HUD), CFR 3280, P ART 24. CAUTION THE STRUCTURAL INTEGRITY OF THE MOBILE HOME F[...]
-
Pagina 5
5 P43 Pellet Stove Assembly and Installation Unpacking The P43 is bolted (1/4 x 1" hex head bolts) to the skid to prevent movement during shipping. T o free the stove from the skid you must remove the hold-down bolts in the rear of the pedestal base. Removing rear cover panels The rear cover panels are secured to the stove with three bolts eac[...]
-
Pagina 6
6 P43 Pellet Stove Installing Place the stove on a noncombustible oor protector that extends a minimum of 6 inches to the front, (mea- sured from the glass) 6 inches to the sides and 1 inch to the rear of the hopper . In some places, it is required that oor protection be installed under any horizon[...]
-
Pagina 7
7 P43 Pellet Stove V enting Requirements for T erminating the V enting W ARNING: V enting terminals must not be recessed into a wall or siding. NOTE: Only approved pellet vent pipe, wall pass- throughs, and re stops should be used when venting through combustible materials. NOTE: Always take into consideration the ef f[...]
-
Pagina 8
8 P43 Pellet Stove V enting A co mb us ti on b lo we r is us ed t o ext ra ct t he combustion gases from the rebox. This causes a negative pressure in the rebox and a positive pres - sure in the venting system as shown in Fig. 7. The longer the vent pipe and more elbows used in the system, th[...]
-
Pagina 9
9 P43 Pellet Stove Outside air ex pipe goes here. Inlet Cover part# 1-10-08542 Flex pipe part# 1-00-08543 (25') Outside Air Here a refourbenetsof outside air: 1. Having air introduced from outside the living area boosts thermal efciency . Because the make up air is not being drawn in through leaky windows[...]
-
Pagina 10
10 P43 Pellet Stove #2 Preferred method This method also provides excellent venting for normal operation but requires the stove to be installed farther from the wall. The vertical portion of the vent should be three to ve feet high and at lea st thre e i nch es fro m a co mbu sti ble w all . Thi s vertical sec[...]
-
Pagina 11
1 1 P43 Pellet Stove #4 Installing into an existing chimney This method provides excellent venting for normal operation. This method also provides natural draft in the event of a power failure. If the chimney condition is questionable* you may want to install a liner as in method #7. In some places in the US and Canada it is required that the vent [...]
-
Pagina 12
12 P43 Pellet Stove #6 Installing into an existing replace chimney This method provides excellent venting for normal operation. This method also provides natural draft in the event of a power failure. In some places in the US and Canada it is re- quired that the vent pipe extend all the way to the top of the chimney . The pipe or liner inside th[...]
-
Pagina 13
13 P43 Pellet Stove #8 Installing through the ceiling Through the ceiling vent, follow PLvent manufacturers recommendations when using wall and ceiling pass through. Note: Do not place joints within wall pass-throughs. Fig. 14 PL vent manufacturer's firestop spacer and support (See Page 6 for corner installation clearances) Minimum flue vent c[...]
-
Pagina 14
14 P43 Pellet Stove P43 AUTOMA TIC IGNITION ESP CONTROL Feed adjuster Sets the maximum feed rate T est Runs all motors at full speed for one minut e to check operation. After two minutes the stove will go to minimum burn and the blowers will alternate from high to low every minute to remin d you that you are still in "T est Mode". Igniter[...]
-
Pagina 15
15 P43 Pellet Stove P43 AUTOMA TIC IGNITION/OPERA TION Room T emperature Mode: This setting, see above, will produce a room temperature of 70 degrees with the distribution blower at medium speed. The P43 is a fully automatic stove that features two op era ting mod es ; Stov e T em pera ture Mod e and Roo m T emperature Mode . In Stove T emperature [...]
-
Pagina 16
16 P43 Pellet Stove Stove T emperature Mode In the Stove T emperature Mode and with the igniter toggle switch in the Auto position, the stove will light automa tically and can be adjusted to the desire d setting using the same temperature control dial as is used in the Room T emperature Mode. The heat output and fuel consumption will remain constan[...]
-
Pagina 17
17 P43 Pellet Stove Igniter Switch to"AUTO"(up position) Make sure the unit is plugged into a 120 V AC, 60 HZ electrical source. The power light should be the only light lit. 1. T urn Mode Selector to "OFF". 2. Fill hopper with pellets. 1 3. Clean burn pot with scraper , if necessary . 5 4. If starting after an empty hopper , tu[...]
-
Pagina 18
18 P43 Pellet Stove The P43 Pellet Stove is capable of manual operation. This also allows the operator to manually control operation during an emergency (i.e. igniter failure, when using a 502H battery backup, as opposed to the 512H, or when using certain generators.) The unit can be switched between "AUTO" and "MANUAL" at any t[...]
-
Pagina 19
19 P43 Pellet Stove P43 MANUAL ST ART UP Igniter Switch to"MANUAL" (down position) Make sure the unit is plugged into a 120 V AC, 60 HZ electrical source. The power light should be the only light lit. 1. T urn FEED ADJUSTER to desired feed rate . No. 4 is good for most pellets. 4 2. T urn the MODE SELECTOR to “OFF” and then to the des[...]
-
Pagina 20
20 P43 Pellet Stove These units are pre-tested at the factory with exactly 120 V olts A.C., 60 Hz. They are checked and adjusted for rebox tightness, gasket leakage, motor operation and igniter operation. The P43 is then factory set at a mid -poi nt adju stme nt and in most case s will not need any adj ustm ent s. NOTE : The[...]
-
Pagina 21
21 P43 Pellet Stove The room sensor is a small temperature sensor on the end of a 60" wire. This sensor is installed much like a standard wall thermostat. Because it is so small, it can be hidden along the trim of a door- way or even up the leg of a coffee table. There is a remote room sensor port on the rear of the unit for easy external conn[...]
-
Pagina 22
22 P43 Pellet Stove Removing Ashes: When approximately 1 ton of pellets has been burned, it will be necessary to empty the ash pan. Ash es sh oul d be pla ced in a meta l cont ain er with a tight tting lid. The closed container of ashes should be placed on a noncombustible oor or on the ground, well away from all com - bustible materials, pen[...]
-
Pagina 23
23 P43 Pellet Stove Exposed blower wheel and ue opening, NOTE: ESP probe is visible. Blower cover removed. ESP probe 8. Clean the combustion blower wheel with a brush and a vacuum cleaner . Note: Do not use a household vacuum to clean the stove. W e recommend that you usea shopvacuumthat isequipped witha nedust?[...]
-
Pagina 24
24 P43 Pellet Stove Burn Pot Cleaning and Maintenance 1. Scrape the top holed surface and sides of the burn pot. (Fig 33) It is not neces sary to comple tely remove all material from the burn pot. The excess will be pushed out during the next use. 2. Loosen the (2) wing thumb screws on the lower front angle of the burn pot. (Fig. 34) 3. Li ft of f [...]
-
Pagina 25
25 P43 Pellet Stove P43 Maintenance - Cleaning the Feeder Body Pellet nes will accumulate in the feeder body over a period of time; therefore, a yearly inspection and cleaning of this area must be performed. T ocleanoutnes: 1. Remove the rear cover panels. 2. Remove wing nut and feeder cover on the side of [...]
-
Pagina 26
26 P43 Pellet Stove FEEDER DOES NOT FEED 1. No pellets in hopper . 2. Firebox draft may be too low for low draft pressure switch in feeder circuit to operate. Check for closed doors , loose or missing gasket on doors or hopper lid, or a faulty pressure switch. 3. Fe ed mot or wil l not ru n unt il th e ESP co ntr ol se nses 165 deg. F . Maybe you d[...]
-
Pagina 27
27 P43 Pellet Stove P43 Feeder[...]
-
Pagina 28
28 P43 Pellet Stove Weight 212 lbs. Blower 135 cfm Feed Rate approximate .75lb. to 5.5 lbs per hr Hopper Capacity 50 lbs Fuel Wood Pellets Flue Size 3 inch Outside Air Size 2 3/8" I.D. inch Fuse Rating 6 amp P43 Specications 12.375" 5.25" 32" 9" 22" 28.5"[...]
-
Pagina 29
29 P43 Pellet Stove OPTIONS Side Heat Shields Side heat shields are available to reduce the clearance to combustible materials. Part #1-00-00000 Hopper Extension The hoppe r ext ensi on allows you to put more pellet fuel in the hopper and extends burn time on one load of pellets. The hopper extension adds 60 pounds to the existing 60 pound hopper c[...]
-
Pagina 30
30 P43 Pellet Stove P43 Wiring Diagram[...]
-
Pagina 31
31 P43 Pellet Stove Description Part Number Hopper Gasket(5 ft.) 0-88-00248 Ash Pan Assembly 1-10-7738108 Burn Pot Weldment 1-10-00675 Right Rear Shield 2-00-773828-1P Left Rear Shield 2-00-773828-2P Arrow Scraper 2-00-773850 Flame Guide 3-00-03000 Wiring Harness Assembly 3-20-08727 Thermister Probe 3-20-00844(red wire) Room Sensor 3-20-00906 Circu[...]
-
Pagina 32
HARMAN GOLD W ARRANTY 6 YEAR TRANSFERABLE LIMITED W ARRANTY (Residential) 1 YEAR LIMITED W ARRANTY (Commercial) Harman warrants its products to be free from defects in material or workmanship, in normal use and service, for a period of 6 years from the date of sales invoice and for mechanical and electrical failures, in normal use and service, for [...]