Heat & Glo LifeStyle 8000CMOD-IPI manuale d’uso
- Visualizza on-line o scarica il manuale
- 71 pagine
- 3.97 mb
Vai alla pagina of
Manuali d’uso simili
-
Indoor Fireplace
Heat & Glo LifeStyle 6000TRI-SP
34 pagine 1.38 mb -
Indoor Fireplace
Heat & Glo LifeStyle SL-950TV-IPI-E
47 pagine 4.54 mb -
Indoor Fireplace
Heat & Glo LifeStyle CF550E-B
28 pagine 1.78 mb -
Indoor Fireplace
Heat & Glo LifeStyle 8000TVC
31 pagine 1.39 mb -
Indoor Fireplace
Heat & Glo LifeStyle SL-42 DVT
46 pagine 1.33 mb -
Indoor Fireplace
Heat & Glo LifeStyle BE-41IPIC
69 pagine 4.44 mb -
Indoor Fireplace
Heat & Glo LifeStyle ST-CFL-24LP
21 pagine 1.1 mb -
Indoor Fireplace
Heat & Glo LifeStyle FB-GRAND-S
42 pagine 2.45 mb
Un buon manuale d’uso
Le regole impongono al rivenditore l'obbligo di fornire all'acquirente, insieme alle merci, il manuale d’uso Heat & Glo LifeStyle 8000CMOD-IPI. La mancanza del manuale d’uso o le informazioni errate fornite al consumatore sono la base di una denuncia in caso di inosservanza del dispositivo con il contratto. Secondo la legge, l’inclusione del manuale d’uso in una forma diversa da quella cartacea è permessa, che viene spesso utilizzato recentemente, includendo una forma grafica o elettronica Heat & Glo LifeStyle 8000CMOD-IPI o video didattici per gli utenti. La condizione è il suo carattere leggibile e comprensibile.
Che cosa è il manuale d’uso?
La parola deriva dal latino "instructio", cioè organizzare. Così, il manuale d’uso Heat & Glo LifeStyle 8000CMOD-IPI descrive le fasi del procedimento. Lo scopo del manuale d’uso è istruire, facilitare lo avviamento, l'uso di attrezzature o l’esecuzione di determinate azioni. Il manuale è una raccolta di informazioni sull'oggetto/servizio, un suggerimento.
Purtroppo, pochi utenti prendono il tempo di leggere il manuale d’uso, e un buono manuale non solo permette di conoscere una serie di funzionalità aggiuntive del dispositivo acquistato, ma anche evitare la maggioranza dei guasti.
Quindi cosa dovrebbe contenere il manuale perfetto?
Innanzitutto, il manuale d’uso Heat & Glo LifeStyle 8000CMOD-IPI dovrebbe contenere:
- informazioni sui dati tecnici del dispositivo Heat & Glo LifeStyle 8000CMOD-IPI
- nome del fabbricante e anno di fabbricazione Heat & Glo LifeStyle 8000CMOD-IPI
- istruzioni per l'uso, la regolazione e la manutenzione delle attrezzature Heat & Glo LifeStyle 8000CMOD-IPI
- segnaletica di sicurezza e certificati che confermano la conformità con le norme pertinenti
Perché non leggiamo i manuali d’uso?
Generalmente questo è dovuto alla mancanza di tempo e certezza per quanto riguarda la funzionalità specifica delle attrezzature acquistate. Purtroppo, la connessione e l’avvio Heat & Glo LifeStyle 8000CMOD-IPI non sono sufficienti. Questo manuale contiene una serie di linee guida per funzionalità specifiche, la sicurezza, metodi di manutenzione (anche i mezzi che dovrebbero essere usati), eventuali difetti Heat & Glo LifeStyle 8000CMOD-IPI e modi per risolvere i problemi più comuni durante l'uso. Infine, il manuale contiene le coordinate del servizio Heat & Glo LifeStyle in assenza dell'efficacia delle soluzioni proposte. Attualmente, i manuali d’uso sotto forma di animazioni interessanti e video didattici che sono migliori che la brochure suscitano un interesse considerevole. Questo tipo di manuale permette all'utente di visualizzare tutto il video didattico senza saltare le specifiche e complicate descrizioni tecniche Heat & Glo LifeStyle 8000CMOD-IPI, come nel caso della versione cartacea.
Perché leggere il manuale d’uso?
Prima di tutto, contiene la risposta sulla struttura, le possibilità del dispositivo Heat & Glo LifeStyle 8000CMOD-IPI, l'uso di vari accessori ed una serie di informazioni per sfruttare totalmente tutte le caratteristiche e servizi.
Dopo l'acquisto di successo di attrezzature/dispositivo, prendere un momento per familiarizzare con tutte le parti del manuale d'uso Heat & Glo LifeStyle 8000CMOD-IPI. Attualmente, sono preparati con cura e tradotti per essere comprensibili non solo per gli utenti, ma per svolgere la loro funzione di base di informazioni e di aiuto.
Sommario del manuale d’uso
-
Pagina 1
1 Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev . H • 5/12 • DO NOT store or use gasoline or other fl am- mable vapors and liquids in the vicinity of this or any other appliance. • What to do if you smell gas - DO NOT try to light any appliance. - DO NOT touch any electrical switch. DO NOT use any phone in your building. - I[...]
-
Pagina 2
Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev . H • 5/12 2 Listing Label Information/Location Model Name: ___________________________________________ Date purchased/installed: __________________ Serial Number: __________________________________________ Location on fi replace: _____________________ Dealership purchased from: ____[...]
-
Pagina 3
3 Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev . H • 5/12 Safety Alert Key: • DANGER! Indicates a hazardous situation which, if not avoided will result in death or serious injury . • W ARNING! Indicates a hazardous situation which, if not avoided could result in death or serious injury . • CAUTION! Indicates a hazardous si[...]
-
Pagina 4
Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev . H • 5/12 4 = Contains updated information. 13 Finishing A. Mantel and Wall Projections . . . . . . . . . . . . . . . . . . . . . . . 47 B. Facing Material . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48 C. Finish and Sealing Joints . . . . . . . . . . . . . [...]
-
Pagina 5
5 Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev . H • 5/12 B. Limited Lifetime W arranty 4021-645C 12-29-10 Page 1 of 2 Hearth & Home T echnologies Inc. LIMITED LIFETIME W ARRANTY Hearth & Home T echnologies Inc., on behalf of its hearth brands (”HHT”), extends the following warranty for HHT gas, wood, pellet, coal an[...]
-
Pagina 6
Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev . H • 5/12 6 4021-645C 12-29-10 Page 2 of 2 W ARRANTY CONDITIONS: 7KLVZDUUDQWRQOFRYHUV++7DSSOLDQFHVWKDWDUHSXUFKDVHGW KURXJKDQ++7 DXWKRUL]HGGHDOHURUGLVWULEXWRU $ OLVWRI ++7DXWKRUL]HGGHDOHUVLVDYDLODEOHR[...]
-
Pagina 7
7 Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev . H • 5/12 C. BTU Speci fi cations MODELS: 6000CMOD-IPI, 8000CMOD-IPI LABORATORY: Underwriters Laboratories, Inc. (UL) TYPE: Direct Vent Gas Appliance Heater STANDARD: ANSI Z21.50b-2009 • CSA 2.22b-2009 This product is listed to ANSI standards for “V ented Gas Appliance Heaters[...]
-
Pagina 8
Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev . H • 5/12 8 H. Requirements for the Commonwealth of Massachusetts For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole or in part for residential purposes, including those owned or operated by the Commonwealth and[...]
-
Pagina 9
9 Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev . H • 5/12 Figure 2.1 General Operating Parts B. Y our Fireplace W ARNING! DO NOT operate fi replace before read- ing and understanding operating instructions. Failure to operate fi replace according to operating instructions could cause fi re or injury . DECORA TIVE DOORS (NOT S[...]
-
Pagina 10
Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev . H • 5/12 10 D. Clear Space W ARNING! DO NOT place combustible objects in front of the fi replace or block louvers. High temperatures may start a fi re. See Figure 2.2. Avoid placing candles and other heat-sensitive objects on mantel or hearth. Heat may damage these objects. Figure[...]
-
Pagina 11
11 Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev . H • 5/12 Nine Hour Safety Shutdown Feature This appliance has a safety feature that automatically shuts down the fi replace after 9 hours of continuous operation without receiving a command from the RC300 remote. J. Before Lighting Fireplace Before operating this fi replace for[...]
-
Pagina 12
Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev . H • 5/12 12 K. Lighting Instructions (IPI) 1. This appliance is equipped with an ignition device which automatically lights the burner. DO NOT try to light the burner by hand. 2. Wait fi ve (5) minutes to clear out any gas. Then smell for gas, including near the fl oor. If you sme[...]
-
Pagina 13
13 Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev . H • 5/12 Initial Break-in Procedure • The fireplace should be run three to four hours continuously on high. • T urn the fi replace off and allow it to completely cool. • Remove fi xed glass assembly . See Section 14.G. • Clean fi xed glass assembly . See Section 3. •[...]
-
Pagina 14
Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev . H • 5/12 14 Glass Cleaning Frequency: Seasonally By: Homeowner T ools Needed : Protective gloves, glass cleaner , drop cloth and a stable work surface. CAUTION! Handle fi xed glass assembly with care. Glass is breakable. • Avoid striking, scratching or slamming glass • Avoid ab[...]
-
Pagina 15
15 Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev . H • 5/12 • Con fi rm there is no damage to glass or glass frame. Replace as necessary . • V erify that fi xed glass assembly is properly retained and attachment components are intact and not damaged. Replace as necessary . Interior Ceramic Glass Panel Cleaning Frequency: Se[...]
-
Pagina 16
Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev . H • 5/12 16 Figure 3.3 Glass Panel Removal C. Glass Refractory , Base Pan, Burner and V alve Assembly Removal It may become necessary to remove the glass panels, base pan, burner and valve assembly . This task should be performed by a quali fi ed service technician. Figure 3.4 Base[...]
-
Pagina 17
17 Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev . H • 5/12 Figure 3.6 V alve Assembly Removal Appearance of valve components may vary . 8000CMOD-IPI (NG) 8000CMOD-IPI (LP) Figure 3.8 V alve Assembly Removal 6000CMOD-IPI (NG) 6000CMOD-IPI (LP) Figure 3.7 V alve Assembly Removal D. Burner Identi fi cation[...]
-
Pagina 18
Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev . H • 5/12 18 A. T ypical Appliance System NOTICE: Illustrations and photos re fl ect typical installations and are for design purposes only . Illustrations/diagrams are not drawn to scale. Actual product may vary from pictures in manual Figure 4.1 T ypical System CEILING FIRESTOP ON[...]
-
Pagina 19
19 Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev . H • 5/12 B. Design and Installation Considerations Heat & Glo direct vent gas appliances are designed to operate with all combustion air siphoned from outside of the building and all exhaust gases expelled to the outside. No additional outside air source is required. Installa[...]
-
Pagina 20
Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev . H • 5/12 20 5 5 F raming and Clearances A. Selecting Appliance Location When selecting a location for the appliance it is important to consider the required clearances to walls (see Figure 5.1). W ARNING! Risk of Fire or Burns! Provide adequate clearance around air openings and for [...]
-
Pagina 21
21 Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev . H • 5/12 B. Constructing the Appliance Chase A chase is a vertical box-like structure built to enclose the gas appliance and/or its vent system. In cooler climates the vent should be enclosed inside the chase. NOTICE: T reatment of ceiling fi restops and wall shield fi restops [...]
-
Pagina 22
Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev . H • 5/12 22 D. Mantel and W all Projections W ARNING! Risk of Fire! Comply with all minimum clear- ances as speci fi ed. Framing or fi nishing material closer than the minimums listed must be constructed entirely of noncom- bustible materials (i.e., steel studs, concrete board, et[...]
-
Pagina 23
23 Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev . H • 5/12 A. V ent T ermination Minimum Clearances Roof Pitch H (Min.) Ft. Flat to 6/12...........................................................1.0* Over 6/12 to 7/12 .................................................1.25* Over 7/12 to 8/12 .......................................[...]
-
Pagina 24
Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev . H • 5/12 24 Figure 6.3 Minimum Clearances for T ermination O N P R Q X = AIR SUPPL Y INLET A = 12 inches................. clearances above grade, veranda, porch, deck or balcony B = 12 inches................. clearance to window or door that may be opened, or to permanently closed w[...]
-
Pagina 25
25 Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev . H • 5/12 A. Approved Pipe This appliance is approved for use with Hearth & Home T echnologies DVP or SLP venting systems. Refer to Sec- tion 16B for vent component information. DO NOT mix pipe, fi ttings or joining methods from differ- ent manufacturers. The pipe is tested t[...]
-
Pagina 26
Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev . H • 5/12 26 H 1 V 1 Figure 7.3 T op V ent - Horizontal T ermination T op V ent - Horizontal T ermination One Elbow Note: For corner installations: A 6 inch (152 mm) section of straight pipe may need to be attached to the appliance before a 90º elbow , to allow the vent pipe to clea[...]
-
Pagina 27
27 Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev . H • 5/12 INST ALLED HORIZONT ALL Y H 1 H 2 V 1 Figure 7.4 T wo Elbows Note: For corner installations: A 6 inch (152 mm) section of straight pipe may need to be attached to the appliance before a 90º elbow , to allow the vent pipe to clear the top standoffs. 6000CMOD-IPI V 1 Mini[...]
-
Pagina 28
Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev . H • 5/12 28 Figure 7.5 T op V ent - Horizontal T ermination - (continued) Three Elbows H 2 H 1 V 2 V 1 V 1 Min. H 1 Max. V 2 Min. H 2 Max. Elbow only 2 ft. 610 mm 0 in. 0 mm 1 ft. 305 mm 6 in. 152 mm 3 ft 914 mm 6 in. 152 mm 2 ft. 610 mm 1 ft. 305 mm 6 ft. 1.8 m 1 ft. 305 mm 6 ft. 1[...]
-
Pagina 29
29 Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev . H • 5/12 FLUE RESTRICTOR T op V ent - V ertical T ermination No Elbow Figure 7.6 Note: If installing a vertical vent/ termination off the top of the appli- ance, the fl ue restrictor should be used. See Figure 7.9. V 1 V 1 = 40 ft. Max. (12.4 m) V 1 = 3 ft. Min. (914 mm) Figure [...]
-
Pagina 30
Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev . H • 5/12 30 H 1 V 1 V 2 T op V ent - V ertical T ermination (continued) Figure 7.1 1 T wo Elbows Figure 7.10 4. Center the Flue Restrictor on vent and secure in place by using two self-tapping screws (see Figure 7.10). 5. Reinstall the Exhaust Shield. 3. Match the amount of vertical[...]
-
Pagina 31
31 Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev . H • 5/12 Figure 7.12 T op V ent - V ertical T ermination - (continued) Three Elbows INST ALLED HORIZONT ALL Y H 1 H 2 V 1 V 2 V 1 H 1 + H 2 V 2 V 1 + V 2 Minimum H 1 + H 2 Maximum Elbow only 1 ft. 305 mm * * * 1 ft. 305 mm 6 in. 152 mm 2 ft. 610 mm * * * 2 ft. 610 mm 1 ft. 305 mm[...]
-
Pagina 32
Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev . H • 5/12 32 A* B 10 in. 12 in. A. Pipe Clearances to Combustibles W ARNING! Risk of Fire! Maintain air space clearance to vent. DO NOT pack insulation or other combustibles: • Between ceiling fi restops • Between wall shield fi restops • Around vent system Failure to keep in[...]
-
Pagina 33
33 Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev . H • 5/12 C. Install the Ceiling Firestop A ceiling fi restop MUST be used between fl oors and attics. • DVP pipe only - Frame an opening 10 in. by 10 in. (254 mm by 254 mm) whenever the vent penetrates a ceiling/ fl oor (see Figure 8.3). • SLP pipe only - Frame opening 9 i[...]
-
Pagina 34
Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev . H • 5/12 34 D. Install Attic Insulation Shield W ARNING! Fire Risk. DO NOT allow loose materials or insulation to touch vent. Hearth & Home T echnologies Inc. requires the use of an attic shield. The National Fuel Gas Code ANSI Z223.1 and NFPA 54 requires an attic shield constru[...]
-
Pagina 35
35 Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev . H • 5/12 9 9 Appliance Preparation CAUTION! Risk of Cuts, Abrasions or Flying Debris. Wear protective gloves and safety glasses during instal- lation. Sheet metal edges are sharp. A. T op V ent Figure 9.1 Cut the seal cap strap across the rectangles next to the disk. For rear ven[...]
-
Pagina 36
Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev . H • 5/12 36 Figure 9.7 Non-combustible Board B. Installing the Non-combustible Board The factory supplied non-combustible board spans the distance from the top of the fi replace to the center of the framing header . This board must be used. See Figure 9.7. HEADER HEADER C. Securing[...]
-
Pagina 37
37 Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev . H • 5/12 1 0 10 Inst alling V ent Pipe (D VP and SLP P ip e ) A. Assemble V ent Sections (DVP Pipe Only) Attach V ent to the Firebox Assembly Note: The end of the pipe sec tions wi t h the lanced tabs w ill face toward the appliance. Attach the fi rst pipe section to the startin[...]
-
Pagina 38
Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev . H • 5/12 38 B. Assemble V ent Sections (SLP Pipe Only) T o attach the fi rst vent component to the starting collars of the appliance: • Attach a DVP-2SL or DVP-SLP24 adapter to the starting collar of the appliance. • Lock the vent components into place by sliding the pipe secti[...]
-
Pagina 39
39 Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev . H • 5/12 120º Figure 10.8 Securing V ertical Pipe Sections 120º Figure 10.9 Securing Horizontal Pipe Sections E. Disassemble V ent Sections • Rotate either section (see Figure 10.10) so the seams on both pipe sections are aligned as shown in Figure 10.1 1. • Pull carefully [...]
-
Pagina 40
Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev . H • 5/12 40 F . Install Decorative Ceiling Components (SLP only) A decorative ceiling thimble can be installed on a fl at ceil- ing through which the vent passes. The decorative ceiling thimble is used to cover the fi restop. • Seal the gap between the vent pipe and fi restop u[...]
-
Pagina 41
41 Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev . H • 5/12 G. Install Metal Roof Flashing • See minimum vent heights for various pitched roofs (Figure 10.14) to determine the length of pipe to extend through the roof. • Slide the roof fl ashing over the pipe sections extending through the roof as shown in Figure 10.15. Roof[...]
-
Pagina 42
Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev . H • 5/12 42 SCREWS CAULK STORM COLLAR (1 of 3) Figure 10.23 Figure 10.23 TERMINA TION CAP I. Install V ertical T ermination Cap • Attach the vertical termination cap by sliding the inner collar of the cap into the inner fl ue of the pipe section while placing the outer collar of [...]
-
Pagina 43
43 Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev . H • 5/12 Figure 10.25 Venting through the wall INTERIOR HEA T SHIELD OR EXTENDED HEA T SHIELD W ALL SHIELD FIRESTOP HEA T SHIELD 1-1/2 IN. (38 MM) MIN. OVERLAP SHEA THING VENT DEPTH FROM BACK OF APPLIANCE T O OUTSIDE SURF ACE OF EXTERIOR WALL (SEE CHART BELOW) SLIP SECTION CAN BE[...]
-
Pagina 44
Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev . H • 5/12 44 A. Fuel Conversion • Make sure the appliance is compatible with available gas types. • Conversions must be made by a qualified service technician using Hearth & Home T echnologies speci fi ed and approved parts. B. Gas Pressure • Optimum appliance performance [...]
-
Pagina 45
45 Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev . H • 5/12 A. Wiring Requirements NOTICE: This appliance must be electrically wired and grounded in accordance with local codes or , in the absence of local codes, with National Electric Code ANSI/NFP A 70-latest edition or the Canadian Electric Code CSA C22.1. • Wire the applian[...]
-
Pagina 46
Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev . H • 5/12 46 F . W all Switch Installation for Fan (Optional) If the box is being wired to a wall mounted switch for use with a fan (See Figure 12.3): • The power supply for the appliance must be brought into a switch box. • The power can then be supplied from the switch box to t[...]
-
Pagina 47
47 Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev . H • 5/12 1 3 13 Fi nishing A. Mantel and W all Projections W ARNING! Risk of Fire! Comply with all minimum clear- ances as speci fi ed. Framing closer than the minimums list- ed must be constructed entirely of noncombustible materials (i.e., steel studs, concrete board, etc.) Fi[...]
-
Pagina 48
Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev . H • 5/12 48 B. Facing Material • Metal front faces may be covered with non-combustible materials only . • Facing and/or fi nishing materials must not interfere with air fl ow through louvers, operation of louvers or doors, or access for service. • Facing and/or fi nishing m[...]
-
Pagina 49
49 Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev . H • 5/12 D. Door Selection Only doors certi fi ed for use with this appliance model may be used. Contact your dealer for a list of doors that may be used. The CMOD door can not be used if the appliance is installed directly on the fl oor . See Figure 13.6 and 13.7. WA L L WA L [...]
-
Pagina 50
Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev . H • 5/12 50 Figure 13.8 Finishing Material 1 Inch Thick or Less DOOR 1 in. MAX. FINISHING MA TERIAL (TOP EDGE) Finishing materials 1 inch maximum thick. Stop fi nishing material fl ush with opening. NON-COMBUSTIBLE FINISHING MA TERIAL Finishing Material: 1 Inch Thick or Less - Ove[...]
-
Pagina 51
51 Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev . H • 5/12 DOOR FINISHING MA TERIAL FINISHING MA TERIAL C (Includes 1/8 in. opening each side of door) A (Outside door width) Finishing Material Thickness Greater than 1 Inch B = T op of door to bottom of fi replace. D = Bottom of Finishing Material to Bottom of Fireplace A (Outsi[...]
-
Pagina 52
Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev . H • 5/12 52 A. Remove Fixed Glass Assembly See Section 14.G. B. Remove the Shipping Materials Remove shipping materials from inside or underneath the fi rebox. C. Clean the Appliance Clean/vacuum any sawdust that may have accumulated inside the fi rebox or underneath in the contro[...]
-
Pagina 53
53 Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev . H • 5/12 F . Media Placement W ARNING! Risk of Explosion! Follow media placement instructions. Improperly placed media interfere with proper burner operation. Fireplace will not function properly . Delayed ignition may occur . W ARNING! Choking Hazard! Keep media out of reach of [...]
-
Pagina 54
Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev . H • 5/12 54 Figure 14.7 Placement of Media NO MEDIA ON PILOT OPENING (WHITE AREA) BURNER NO MEDIA ON PILOT OPENING (WHITE AREA) BURNER Figure 14.8 Placement of Media Figure 14.9 Proper Placement of Media[...]
-
Pagina 55
55 Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev . H • 5/12 Figure 14.8 Air Shutter Figure 14.7 Fixed Glass Assembly G. Fixed Glass Assembly W ARNING! Risk of Asphyxiation! Handle fi xed glass assembly with care. Inspect the gasket to ensure it is undamaged and inspect the glass for cracks, chips or scratches. • DO NOT strike,[...]
-
Pagina 56
Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev . H • 5/12 56 1 5 15 T roubleshooting With proper installation, operation, and maintenance your gas appliance will provide years of trouble-free service. If you do experience a problem, this troubleshooting guide will assist a quali fi ed service technician in the diagnosis of a prob[...]
-
Pagina 57
57 Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev . H • 5/12 T roubleshooting (continued) Symptom Possible Cause Corrective Action 4. Pilot lights but contin- ues to spark, and main burner will not ignite. (If the pilot continues to spark after the pilot fl ame has been lit, fl ame recti fi cation has not occurred.) A. A shorte[...]
-
Pagina 58
Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev . H • 5/12 58 1 6 16 Reference Materials A. Appliance Dimension Diagram Dimensions are actual appliance dimensions. Use for reference only . For framing dimensions and clearances refer to Section 5. Figure 16.1 Appliance Dimensions-6000 Models A B C D E FRONT VIEW TOP VIEW LEFT SIDE R[...]
-
Pagina 59
59 Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev . H • 5/12 Figure 16.2 Appliance Dimensions-8000 Models Location Inches Millimeters J 21 533 K 1 1-1 1/16 297 L 35-1/2 901 M 17-3/4 451 N 8-1/2 216 O 2-7/8 73 P 8-1/2 216 Q1 2 5 R 42-7/8 1089 Location Inches Millimeters A 48 1219 B 43-1/8 1096 C 35-1/2 902 D 36-5/8 930 E 2-3/8 60 F[...]
-
Pagina 60
Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev . H • 5/12 60 B. V ent Components Diagrams Figure 16.2 DVP vent components Pipe Effective Length Inches Millimeters DVP4 4 102 DVP6 6 152 DVP12 12 305 DVP24 24 610 DVP36 36 914 DVP48 48 1219 DVP6A 3 to 6 76 to 152 DVP12A 3 to 12 76 to 305 DVP12MI 3 to 12 76 to 305 DVP24MI 3 to 24 76 t[...]
-
Pagina 61
61 Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev . H • 5/12 DVP-HPC1 DVP-HPC2 DVP-TRAP1 DVP-TRAP2 DVP-TRAPK2 DVP-TRAPK1 DVP-TRAP Horizontal T ermination Cap 15-1/8 in. (384 mm) 12 in. (305 mm) 8 in. (203 mm) Max Effective Length Note: Heat shields MUST overlap by a minimum of 1-1/2 in. (38 mm). The heat shield is designed to be u[...]
-
Pagina 62
Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev . H • 5/12 62 13-1/4 in. (337 mm) 24-5/8 in. (625 mm) 27-1/2 in. (699 mm) RF6M Roof Flashing Multi-pak 31 in. (787 mm) 24-5/8 in. (625 mm) 13-1/4 in. (337 mm) RF12M Roof Flashing Multi-pak BEK Trap Ca p Brick Extension 13-3/4 in. (349 mm) 5 in. (127 mm) 13-3/4 in. (349 mm) Cap Shield [...]
-
Pagina 63
63 Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev . H • 5/12 DVP-TB1 BasementVent Cap 12 in. (305 mm) 1-1/2 in. (38 mm) 7-3/8 in. (187 mm) 14 in. (356 mm) 17-3/4 in. (451 mm) 7-1/4 in. 12 in. 305 mm (184 mm) 5-1/4 in. (133 mm) 12-1/2 in. (318 mm) DVP-TVHW VerticalTermination Cap (Highwind) PVK-80 (Not compatible with Intellifire P[...]
-
Pagina 64
Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev . H • 5/12 64 B. V ent Components Diagrams (continued) DVP-HRC-SS DVP-HRC-ZC-SS HORIZONT AL TERMINA TION CAP 13 in. (330 mm) 15 in. (381 mm) 8-1/8 in. (206 mm) 10-7/8 in. 276 mm 10-1/2 in. 267 mm 3° 87° Effective Length 5-3/4 to 8-3/8 in. 146 to 213 mm 5-1/2 in. 140 mm 8-3/8 in. 213[...]
-
Pagina 65
65 Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev . H • 5/12 B. V ent Components Diagrams (continued) Figure 16.7 SLP Series V ent Components 8-3/4 in. 222 mm 6-1/2 in. 165 mm 6-5/8 in. 168 mm 6 in. 152 mm 6-1/2 in. 165 mm 6-5/8 in. 168 mm 9-7/8 in. 251 mm 6-1/2 in. 165 mm 9-1/4 in. 235 mm SLP45 45° Elbow SLP90 90° Elbow Effecti[...]
-
Pagina 66
Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev . H • 5/12 66 B. V ent Components Diagrams (continued) Figure 16.8 SLP Series V ent Components SLK-SNKD Snorkel T ermination Cap SLP-TVHW V ertical T ermination Cap SLP-CCS-BK Cathedral Ceiling Support Box-Black SLP-DCF-BK Ceiling Firestop Black SLP-WT -BK W all Thimble-Black DVP-2SL [...]
-
Pagina 67
67 Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev . H • 5/12 C. Service Parts Beginning Manufacturing Date: Aug 2010 Ending Manufacturing Date:______ 6000CMOD-IPI 36” Modern Direct V ent Fireplace IMPORT ANT : THIS IS DA TED INFORMA TION. When requesting service or replacement parts for your appliance please provide model number[...]
-
Pagina 68
Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev . H • 5/12 68 C. Service Parts Beginning Manufacturing Date: Aug 2010 Ending Manufacturing Date:______ 8000CMOD-IPI 42” Modern Direct V ent Fireplace IMPORT ANT : THIS IS DA TED INFORMA TION. When requesting service or replacement parts for your appliance please provide model number[...]
-
Pagina 69
69 Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev . H • 5/12 C. Service Parts Beginning Manufacturing Date: Aug 2009 Ending Manufacturing Date: ______ 6000CMOD-IPI, 8000CMOD-IPI IMPORT ANT : THIS IS DA TED INFORMA TION. When requesting service or replacement parts for your appliance please provide model number and serial number . [...]
-
Pagina 70
Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev . H • 5/12 70 Service Parts List 6000CMOD-IPI, 8000CMOD-IPI IMPORT ANT : THIS IS DA TED INFORMA TION. When requesting service or replacement parts for your appliance please provide model number and serial number . All parts listed in this manual may be ordered from an authorized deale[...]
-
Pagina 71
71 Heat & Glo • 6000CMOD-IPI, 8000CMOD-IPI • 2241-900 Rev . H • 5/12 D. Contact Information Please contact your Heat & Glo dealer with any questions or concerns. For the location of your nearest Heat & Glo dealer , please visit www .heatnglo.com. - NOTES - ___________________________________________________________________________[...]