Heatcraft Refrigeration Products CC-CUBZTB manuale d’uso
- Visualizza on-line o scarica il manuale
- 24 pagine
- 3.47 mb
Vai alla pagina of
Manuali d’uso simili
-
Humidifier
Heatcraft Refrigeration Products H-IM-UC
8 pagine 0.42 mb -
Refrigerator
Heatcraft Refrigeration Products H-IM-FL1A
24 pagine 0.62 mb -
Refrigerator
Heatcraft Refrigeration Products PTN
12 pagine 2.4 mb -
Fan
Heatcraft Refrigeration Products RLC
20 pagine 2.32 mb -
Refrigerator
Heatcraft Refrigeration Products PST057L6B*
8 pagine 1.05 mb -
Humidifier
Heatcraft Refrigeration Products 25005601
20 pagine 0.68 mb -
Refrigerator
Heatcraft Refrigeration Products SWN0100H2B
12 pagine 1.8 mb -
Humidifier
Heatcraft Refrigeration Products CH-B-01
12 pagine 0.72 mb
Un buon manuale d’uso
Le regole impongono al rivenditore l'obbligo di fornire all'acquirente, insieme alle merci, il manuale d’uso Heatcraft Refrigeration Products CC-CUBZTB. La mancanza del manuale d’uso o le informazioni errate fornite al consumatore sono la base di una denuncia in caso di inosservanza del dispositivo con il contratto. Secondo la legge, l’inclusione del manuale d’uso in una forma diversa da quella cartacea è permessa, che viene spesso utilizzato recentemente, includendo una forma grafica o elettronica Heatcraft Refrigeration Products CC-CUBZTB o video didattici per gli utenti. La condizione è il suo carattere leggibile e comprensibile.
Che cosa è il manuale d’uso?
La parola deriva dal latino "instructio", cioè organizzare. Così, il manuale d’uso Heatcraft Refrigeration Products CC-CUBZTB descrive le fasi del procedimento. Lo scopo del manuale d’uso è istruire, facilitare lo avviamento, l'uso di attrezzature o l’esecuzione di determinate azioni. Il manuale è una raccolta di informazioni sull'oggetto/servizio, un suggerimento.
Purtroppo, pochi utenti prendono il tempo di leggere il manuale d’uso, e un buono manuale non solo permette di conoscere una serie di funzionalità aggiuntive del dispositivo acquistato, ma anche evitare la maggioranza dei guasti.
Quindi cosa dovrebbe contenere il manuale perfetto?
Innanzitutto, il manuale d’uso Heatcraft Refrigeration Products CC-CUBZTB dovrebbe contenere:
- informazioni sui dati tecnici del dispositivo Heatcraft Refrigeration Products CC-CUBZTB
- nome del fabbricante e anno di fabbricazione Heatcraft Refrigeration Products CC-CUBZTB
- istruzioni per l'uso, la regolazione e la manutenzione delle attrezzature Heatcraft Refrigeration Products CC-CUBZTB
- segnaletica di sicurezza e certificati che confermano la conformità con le norme pertinenti
Perché non leggiamo i manuali d’uso?
Generalmente questo è dovuto alla mancanza di tempo e certezza per quanto riguarda la funzionalità specifica delle attrezzature acquistate. Purtroppo, la connessione e l’avvio Heatcraft Refrigeration Products CC-CUBZTB non sono sufficienti. Questo manuale contiene una serie di linee guida per funzionalità specifiche, la sicurezza, metodi di manutenzione (anche i mezzi che dovrebbero essere usati), eventuali difetti Heatcraft Refrigeration Products CC-CUBZTB e modi per risolvere i problemi più comuni durante l'uso. Infine, il manuale contiene le coordinate del servizio Heatcraft Refrigeration Products in assenza dell'efficacia delle soluzioni proposte. Attualmente, i manuali d’uso sotto forma di animazioni interessanti e video didattici che sono migliori che la brochure suscitano un interesse considerevole. Questo tipo di manuale permette all'utente di visualizzare tutto il video didattico senza saltare le specifiche e complicate descrizioni tecniche Heatcraft Refrigeration Products CC-CUBZTB, come nel caso della versione cartacea.
Perché leggere il manuale d’uso?
Prima di tutto, contiene la risposta sulla struttura, le possibilità del dispositivo Heatcraft Refrigeration Products CC-CUBZTB, l'uso di vari accessori ed una serie di informazioni per sfruttare totalmente tutte le caratteristiche e servizi.
Dopo l'acquisto di successo di attrezzature/dispositivo, prendere un momento per familiarizzare con tutte le parti del manuale d'uso Heatcraft Refrigeration Products CC-CUBZTB. Attualmente, sono preparati con cura e tradotti per essere comprensibili non solo per gli utenti, ma per svolgere la loro funzione di base di informazioni e di aiuto.
Sommario del manuale d’uso
-
Pagina 1
C C C UB Z TB Ap ri l 2 009 , v . 00 1 A I R C O OL E D C O N D E N S I NG U N I TS W I TH B IT Z E R C OM P RE S S OR S T echn ic al Guide ww w .coldyoucancounton.c om C L I M A T E C O N T R O L[...]
-
Pagina 2
2 © 2009 Heatcraft Refrigeration Products, LL C Floating T ube ™ Coil 3 Options 4 Head Pressur e Con trol 5 Bitzer C ompressor F eatures and Benets 6-7 Horizontal A ir Discharge C ondensing Units 4 to 13 HP Standard and Optional F eatures 8 Nomenclature 8 Performance Da ta Medium T emperature - R-404A/R-507 9 L ow T emperature - R-404A/R-507 [...]
-
Pagina 3
3 Expanded (Locked) A uxiliary T ubes: These tubes support the coil with ns and refrigerant carr ying tubes. They do not carr y refrigerant and are tightly tted on end supports and center supports. Fr ee Floating C ircuited C oil T ub es: These tubes carry refrigerant and never touch and sheet metal (end supports and center supports). All con[...]
-
Pagina 4
4 Beacon II ™ Refrigera tion Sy stem Beacon II ™ is the next generation of Climate Con trol’ s patented, preassembled, factory installed refrigeration syst em featuring an integrat ed microcomput er-based electronic control boar d. The Beacon II ™ systems c ome completely factory installed, wired and tested sa ving you time and money . Beac[...]
-
Pagina 5
5 Refrigeration condensing units must efficiently per form at var ying ambient conditions. A properly sized unit will adequately per form at even the highest summer ambient temperatur es. How ever , in situations where the system must opera te the majority of the time at less than design tempera tur e, a means of providing adequate head pr essure f[...]
-
Pagina 6
6 Bit ze r is the wo rld’ s lar gest man ufa ctur er of sem i-h erm eti c re frig er at ion comp re ss ors over 3 HP . I n business since 1934, Bitzer has manufacturing plants in Ger many , Brazil, Portugal, China and the United States and operates in over 100 countries ar o un d th e wo r ld . Bi t ze r ’ s G e o rg i a pl a n t ma n u fa c tu[...]
-
Pagina 7
7 Octagon ® 4C Mo dels Bitzer Oc tagon 4C M odels are rated from 3 to 20 HP . This rugged, compact series utilizes wear resistant drive gear with PTFE coated bearings for especially low fric tion, aluminum pistons of optimized geometr y , connec ting rods with ec ce nt ric stra ps and gen er ou sly dime nsi on ed be ari ng surfac es. Bitz er ’ s[...]
-
Pagina 8
8 3 - 22 HP Condensing Units Horizontal Discharge Nomenclatur e C B T 0000 L 6 C Brand Compr essor Application Horsepow er T emp . R ange Refrigerant V oltage C = Climate Control B = Bitzer T = Outdoor N = Indoor S = Beacon II ™ 0401 - 4 0551 - 5 0601 - 6 0611 -6 0751 - 7.5 0901 - 9 1001 - 10 1201 - 12 1301 - 13 M = Med. T emp. L = Low T emp. 6 =[...]
-
Pagina 9
9 Horizontal Discharge Medium T emp era ture R-404A/R-507 *= T for Outdoors , N for Indoors, S for Beacon II ™ Consult factory on all models for applications above 110°F ambient. Unit Model Number Compressor Model Suction T emp. 90°F Amb . 95°F Amb . 100°F Amb . 110°F Amb . °F CB*0551M6 4C0969SH 40 30 25 20 15 5 89700 75460 68740 62260 5619[...]
-
Pagina 10
10 3 - 22 HP Condensing Units Horizontal Discharge Lo w T emperature – R-404A/R-507 Medium T emp era ture – R-404A/507 *= T for Outdoors , N for Indoors, S for Beacon II ™ ^ Consult factory for 50Hz applications. † MCA = Minimum Circuit Ampacity †† MOP = Maximum Overcurrent Pr otection ‡ Condensing unit data plate ra tings will be bas[...]
-
Pagina 11
11 Horizontal Discharge Medium & Low T empera ture – R-404A/R-507 Specications and Dimensional Data Unit Model Number Compressor Model HP Refrigerant Line Connections (OD ) Receiver C apacity @ 90% full (lbs.) Dimensions (inches) Appro x. Net Wt. (lbs.) Liquid Suction STD OPT Length W idth Height CB*0551M6 4C0969SH 5.5 5/8 1 3/8 67 78 36-3[...]
-
Pagina 12
12 Single V ertical Air Discharge Condensing Unit Standard and Optional F eatures • The Floa ting T ube™ coil design. Refrigerant-carr ying copper tubes do not contact any metal support sheets; instead, the coil is constructed with expanded anchor tubes that support the coil construction and do not car ry refrigerant. The coil design eliminat e[...]
-
Pagina 13
13 Single V ertical Air Discharge Condensing Unit Medium T emperature – R-404A/R-507 P er formanc e Data Unit Model Number Compressor Model Suction T emp . °F 90°F Amb . 95°F Amb . 100°F Amb . 110°F Amb . CDV*150BM6 4C2067PH 40 30 25 20 15 5 197120 165780 150650 136230 122680 98790 188290 157400 143110 129380 116550 93540 178750 150410 13264[...]
-
Pagina 14
14 Single V ertical Air Discharge Condensing Unit Low T emperature – R-404A/R-507 Unit Model Number Compressor Model Suction T emp . °F 90°F Amb . 95°F Amb . 100°F Amb . 110°F Amb . CDV*130BL6 4B2707PL 0 105960 100880 95790 85810 -10 81650 77300 72980 64920 -15 70890 66880 62900 55370 -20 61310 57620 53960 46770 -30 46800 43630 40420 33650 -[...]
-
Pagina 15
15 Single V ertical Air Discharge Condensing Unit Medium & Low T emp eratur e – R-404A/R-507 CDV* = CDVS is Beacon II ™ † MCA = Minimum Circuit Ampacity † † MOP = Maximum Overcurrent Pr otection ‡ Condensing unit data plate ra tings will be based on actual system match. Beacon II ™ and Air Defrost Units do not carry any of the eva[...]
-
Pagina 16
16 Single V ertical Air Discharge Condensing Unit End View Side View Medium & Low T emp eratur e – R-404A/R-507 Dimensions (Inches) Specications and Dimensional Data CDV*= CDVS is Beacon II ™ Unit Model Number Compr essor Model HP Refrigerant Line Connections ( OD) CDV & Beacon II Receiv er Capacity @ 90% full (lbs.s) Dimensions (inc[...]
-
Pagina 17
17 Dual V ertic al Air Discharge C ondensing Unit V er tic al Air Discharge C ondensing Units 26 to 100 HP Dual C ompressor Additional S tandard F eatures for P arallel Piped Units 1. Replaceable core liquid line lter drier 2. Replaceable core suction lter 3. Suction accumulator 4. Oil management system 5. Contact F ac tory for Beacon II TM A[...]
-
Pagina 18
18 Dual V ertic al Air Discharge C ondensing Unit P er formanc e Data Unit Model Number Compressor Model (2 Each) Suction T emp . °F 90°F Amb . 95°F Amb . 100°F Amb . 110°F Amb . CDD*300BM6 4C2067PH 40 394250 376590 357490 324040 30 331570 314800 300810 269290 25 301290 286220 265290 243760 20 272450 258760 246010 219040 15 245360 233090 22089[...]
-
Pagina 19
19 Dual V ertic al Air Discharge C ondensing Unit Unit Model Number Compressor Model (2 Each) Suction T emp . °F 90°F Amb . 95°F Amb . 100°F Amb . 110°F Amb . CDD*260BL6 4B2707PL 0 211930 201760 191580 171630 -10 163290 154600 145970 129850 -15 141770 133760 125810 110740 -20 122620 115230 107910 93530 -30 93600 87260 80840 67290 -40 79760 745[...]
-
Pagina 20
20 Dual V ertic al Air Discharge C ondensing Unit CDD* = CDDS is Beacon II ™ , CDD*PP is Par allel Piped † MCA = Minimum Circuit Ampacity †† MOP = Maximum Overcurrent Pr otection ‡ Condensing unit data plate ra tings will be based on actual system match. Elec trical Data Medium & Low T empera ture – R-404A/507 Unit Model Number Comp[...]
-
Pagina 21
21 Dual V ertic al Air Discharge C ondensing Unit CDD* = CDDS is Beacon II ™ , CDD*PP is Par allel Piped Specications and Dimensional Data U n i t M o d e l N u m b e r C o m p r es so r M od el ( 2 E a c h ) H P C o n n e c t i o n s (i n. c) S t a n d a r d R e c e iv e r C a pa ci ty @ 9 0 % f u l l ( l b s . ) ( 2 e a c h ) P a r al le l P[...]
-
Pagina 22
22 Notes[...]
-
Pagina 23
23[...]
-
Pagina 24
A Brand of Heatcraft Refrigeration P roducts, LL C 2175 West P ark Place Blvd. • Stone Mountain, GA • 30087 (800) 321-1881 ww w .coldyoucancounton.c om Cold Y ou Can Count On Since produ ct imp rovement is a continuin g eor t, we rese r ve the right to make cha nges in sp ecicatio ns without n otice. F or more inf ormation on Climate C on[...]