Vai alla pagina of
Manuali d’uso simili
-
Blood Pressure Monitor
Omron Healthcare HEM-7211-E
27 pagine 1.09 mb -
Blood Pressure Monitor
Omron Healthcare HEM-7211-E8
27 pagine 1.09 mb -
Blood Pressure Monitor
Omron Healthcare HEM-739
26 pagine 0.41 mb -
Blood Pressure Monitor
Omron Healthcare HEM-741CREL
56 pagine 1.34 mb -
Blood Pressure Monitor
Omron Healthcare HEM-757
20 pagine 0.19 mb -
Blood Pressure Monitor
Omron Healthcare HEM-773AC
20 pagine 0.65 mb -
Blood Pressure Monitor
Omron Healthcare HEM-775
104 pagine 1.67 mb -
Blood Pressure Monitor
Omron Healthcare HEM-780
104 pagine 1.72 mb
Un buon manuale d’uso
Le regole impongono al rivenditore l'obbligo di fornire all'acquirente, insieme alle merci, il manuale d’uso Welch 2511. La mancanza del manuale d’uso o le informazioni errate fornite al consumatore sono la base di una denuncia in caso di inosservanza del dispositivo con il contratto. Secondo la legge, l’inclusione del manuale d’uso in una forma diversa da quella cartacea è permessa, che viene spesso utilizzato recentemente, includendo una forma grafica o elettronica Welch 2511 o video didattici per gli utenti. La condizione è il suo carattere leggibile e comprensibile.
Che cosa è il manuale d’uso?
La parola deriva dal latino "instructio", cioè organizzare. Così, il manuale d’uso Welch 2511 descrive le fasi del procedimento. Lo scopo del manuale d’uso è istruire, facilitare lo avviamento, l'uso di attrezzature o l’esecuzione di determinate azioni. Il manuale è una raccolta di informazioni sull'oggetto/servizio, un suggerimento.
Purtroppo, pochi utenti prendono il tempo di leggere il manuale d’uso, e un buono manuale non solo permette di conoscere una serie di funzionalità aggiuntive del dispositivo acquistato, ma anche evitare la maggioranza dei guasti.
Quindi cosa dovrebbe contenere il manuale perfetto?
Innanzitutto, il manuale d’uso Welch 2511 dovrebbe contenere:
- informazioni sui dati tecnici del dispositivo Welch 2511
- nome del fabbricante e anno di fabbricazione Welch 2511
- istruzioni per l'uso, la regolazione e la manutenzione delle attrezzature Welch 2511
- segnaletica di sicurezza e certificati che confermano la conformità con le norme pertinenti
Perché non leggiamo i manuali d’uso?
Generalmente questo è dovuto alla mancanza di tempo e certezza per quanto riguarda la funzionalità specifica delle attrezzature acquistate. Purtroppo, la connessione e l’avvio Welch 2511 non sono sufficienti. Questo manuale contiene una serie di linee guida per funzionalità specifiche, la sicurezza, metodi di manutenzione (anche i mezzi che dovrebbero essere usati), eventuali difetti Welch 2511 e modi per risolvere i problemi più comuni durante l'uso. Infine, il manuale contiene le coordinate del servizio Welch in assenza dell'efficacia delle soluzioni proposte. Attualmente, i manuali d’uso sotto forma di animazioni interessanti e video didattici che sono migliori che la brochure suscitano un interesse considerevole. Questo tipo di manuale permette all'utente di visualizzare tutto il video didattico senza saltare le specifiche e complicate descrizioni tecniche Welch 2511, come nel caso della versione cartacea.
Perché leggere il manuale d’uso?
Prima di tutto, contiene la risposta sulla struttura, le possibilità del dispositivo Welch 2511, l'uso di vari accessori ed una serie di informazioni per sfruttare totalmente tutte le caratteristiche e servizi.
Dopo l'acquisto di successo di attrezzature/dispositivo, prendere un momento per familiarizzare con tutte le parti del manuale d'uso Welch 2511. Attualmente, sono preparati con cura e tradotti per essere comprensibili non solo per gli utenti, ma per svolgere la loro funzione di base di informazioni e di aiuto.
Sommario del manuale d’uso
-
Pagina 1
OWNER’S MANU AL FOR ASPIRA TION / FIL TRA TION V ACUUM SYSTEM MODELS: 2511 & 2515 W elch Rietschle Thomas 7301 North Central Avenue Skokie, IL 60077 Phone: (847) 676-8800 F ax: (847) 677-8606 (T echnical Support) F ax: (920) 451-4397 (Ordering) E-Mail: welchvacuum@thomasind.com P art No. 67-1772R1.1 W eb-P age: www .welchvacuum.com Printed in[...]
-
Pagina 2
INSTRUCTION W ARNING AND CAUTION PLEASE READ BEFORE OPERA TION While reading your manual, please pay close attention to areas labeled: W ARNING AND CAUTION. The description of each is found below . W ARNING W arnings are given wher e failure to observe instruction could r esult in injury or death to people. CAUTION Cautions are found wher e failure[...]
-
Pagina 3
T ABLE OF CONTENTS Section 01 - SAFETY INFORMA TION 1.10 Caution T o Prevent Injury 1.20 Caution T o Reduce Risk Of Electrical Shock 1.30 W arning T o Reduce Risk Of Electrocution 1.40 Danger T o Reduce Risk Of Explosion Or Fire Section 02 - INST ALLA TION 2.10 Introduction 2.20 Unpacking 2.30 Pump Mounting 2.40 Pump Location 2.50 Intake And Discha[...]
-
Pagina 4
SECTION 1: SAFETY INFORMA TION 1.10 Caution: T o Prevent Injury ... 1.1 1 Never operate this product if it has a damaged cord or plug. If it is not working properly , has been dropped, damaged or has fallen into water , please return the product to a W elch service center for examination and repair . 1.12 Keep the cord away from heated surfaces. Al[...]
-
Pagina 5
SECTION 2: INST ALLA TION 2.10 Introduction 2.1 1 This manual has been compiled not only for the care and maintenance of the W elch Aspiration/Filtration V acuum System now in your possession, but as a helpful reference and guide to prevent many problems which may occur if used improperly . 2.20 Unpacking 2.21 Carefully remove the Aspiration/Filtra[...]
-
Pagina 6
2.50 Intake And Discharge Provision 2.51 The vacuum regulator and vacuum dial gauge is attached to the collection jar . The vacuum regulator allows the vacuum level to be set between roughly atmospheric pressure and the maximum vacuum allowed for the pump model. The collection jar and hydrophobic fi lter keeps water from accidentally being drawn i[...]
-
Pagina 7
2.60 Electrical Power 2.61 Power Source Review Review the power source and the motor rating to be sure they agree in voltage, phase, and frequency . Serious damage may occur to the motor if it is connected to an improper voltage. All W elch pumps must be grounded. Grounding reduces the risk of electric shock in the event of an electrical short circ[...]
-
Pagina 8
SECTION 3: OPERA TION 3.10 Starting Procedur es 3.1 1 Starting aW elch Aspiration/Filtration V acuum System Before attaching the pump to a system, familiarize yourself with the function and action of the Aspiration/Filtration V acuum System that you have acquired. Review the power requirements as described in Section 2.60. W elch recommends running[...]
-
Pagina 9
3.30 Operating Pressur e Range 3.31 Aspiration/Filtration V acuum Systems are designed to be run from slightly below atmospheric to their maximum vacuum level on the intake side. The pumps also may be run from atmospheric to their maximum rated pressure rating (Model 251 1 only). Consult the Specification T able for the ratings of your specific m[...]
-
Pagina 10
SECTION 5: TROUBLESHOOTING 5.10 V ACUUM PROBLEMS 5.1 1 Leakage, contamination, and unusual outgassing are the general causes of problems associated with poor vacuum. T o operate at maximum efficiency , a system must be thoroughly clean. If the system is completely clean and free from leaks and unwarranted vacuum problems still exist, the pump shou[...]
-
Pagina 11
5.40 TROUBLE SHOOTING GUIDE FOR 251 1 / 2515 1 1 Symptoms Possible Cause Remedies Reduced/low 1. Clogged hydrophobic 1. Replace the filter vacuum filter. following directions in this manual. (Section 4.12) 2. Regulator improperly 2. Set regulator vacuum set. level following operating instructions. 3. Air leak. 3. Check the tubing and connectors for[...]
-
Pagina 12
SECTION 6: SPECIFICA TION 6.10 SPECIFICA TION T ABLE Cat. No. 2511B-75 2511C-75 2511C-76 2515B-75 2515C-75 2515C-76 Free Air Displacement CFM (L/min) 0.39(11) 0.32(9.2) 0.39(11) 1.2(34) 1.0(28) 1.2(34) Maximum Vacuum in. Hg Ultimate Vacuum Torr (mbar) Dimensions L x W x H in. (cm) Shipping Weight, lbs Electrical Requirements 115V, 60 Hz 230V, 50Hz [...]
-
Pagina 13
SECTION 7: W ARRANTY W arranty Infor mation Model No. Serial No. Date Purchased Name Company Address Zip City State Code Phone No. Purchased From Application For any additional information/literature needed, please check below: ❑ Laborator y Catalog ❑ Industrial Catalog Belt Drive Belt Drive Direct Drive Direct Drive Dry Pumps Dry Pumps Accesso[...]
-
Pagina 14
SECTION 8: EXPLODED VIEW & P AR TS LIST 8.10 Model 251 1B-75 / 251 1C-75 / 251 1C-76 PUMP ON/OFF SWITCH REGULA TOR KNOB V ACUUM GAUGE SHOR T TUBING LONG TUBING APPLICA TION TUBING HYDROPHOBIC FIL TER PRESSURE POR T COLLECTION JAR 14[...]
-
Pagina 15
8.1 1 Model 2515B-75 / 2515C-75 / 2515C-76 COLLECTION JAR LONG TUBING APPLICA TION TUBING HYDROPHOBIC FIL TER PUMP ON/OFF SWITCH REGULA TOR KNOB V ACUUM GAUGE SHOR T TUBING 15[...]
-
Pagina 16
8.12 Model 1475K-20 COLLECTION JAR LONG TUBING APPLICA TION TUBING HYDROPHOBIC FIL TER SHOR T TUBING 16[...]
-
Pagina 17
SECTION 9: KITS AND ACCESSORIES 9.10 REP AIR KITS 9.1 1 Repair Kit for Model 2515 Service Seal Gasket Description Kit Kit 2515K-01 2515K-02 Connecting Rod Assembly #1 1 - Handle Screw #2 2 - Head Screw #3 4 - Head O-Ring #4 1 1 Valve Plate Assembly #5 1 - Cylinder O-Ring #6 1 1 17[...]
-
Pagina 18
9.20 V ACUUM ACCESSORIES 9.21 T able for V acuum Accessories Description Welch Kit Adapter S.S. 40mm 1475K-01 8-Channel Adapter S.S. 40mm 1475K-02 1-Channel Adapter for dispoable tips, w/o ejector 1475K-03 Rubber Adapter for Pasteur pipettes 1475K-04 8-Channel Adapter for dispoable tips, w/ejector 1475K-05 Adapter S.S. 150mm 1475K-06 4-Channel Adap[...]
-
Pagina 19
9.30 ELECTRICAL ACCESSORIES 9.31 T able for Electrical Accessories 9.40 REPLACEMENT ACCESSORIES 9.41 T able for Replacement Accessories Description Welch Kit 115V 60Hz - Maintained on/off footswitch 1430A 115V 60Hz - Variable on/off footswitch 1430B 90-230V 50/60Hz - Variable on/off footswitch with IEC connections 1430C 19 Description Welch Kit Asp[...]
-
Pagina 20
W elch Rietschle Thomas V acuum Pump Repair Facility 7301 North Central Avenue Skokie, IL 60077 Phone: (847) 676-8800 F ax: (847) 677-8606 (T echnical Support) F ax: (920) 451-4397 (Ordering) Copyright© 1997-2004 Welch Rietschle Thomas Welch is registered trademarks of W elch Rietschle Thomas[...]