3M 900AST manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of 3M 900AST, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of 3M 900AST one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of 3M 900AST. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of 3M 900AST should contain:
- informations concerning technical data of 3M 900AST
- name of the manufacturer and a year of construction of the 3M 900AST item
- rules of operation, control and maintenance of the 3M 900AST item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of 3M 900AST alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of 3M 900AST, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the 3M service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of 3M 900AST.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the 3M 900AST item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    Adv anced Systems T ester 900AST Series Coaxial W ire T esting T echnical T ip December 2005 78-8135-6156-6-A[...]

  • Page 2

    3M ™ Advanced Systems T ester 900AST Ser ies 2 Setup f or Use Battery Requirement The battery holder holds six “ AA” standard alkaline batteries and should be installed prior to using the unit. Please see the 900AST tester manual or D VD for battery installation instructions. Always initiate a self-calibration after installing ne w batteries.[...]

  • Page 3

    3M ™ Advanced Systems T ester 900AST Ser ies 3 Ke ypad The 900AST tester ke ypad has twelve yello w and red “Control K eys” and nine blue “Function K eys”. Additional blue ke ys on the keypad are reserv ed for future expansion and ha ve no designation or current function. Control Keys Use the red and yello w keys to control and setup the [...]

  • Page 4

    3M ™ Advanced Systems T ester 900AST Ser ies 4 Contrast and Backlighting Note: Use of backlight decreases available battery capacity . Pre ss the k e y t o d ispl ay the co ntr ast scr een . Use the and ke ys to adj ust the con tra st. Press the ke y aga in to turn the back lig ht on or of f. Use the ke y to return to previous screen. Function Ke[...]

  • Page 5

    3M ™ Advanced Systems T ester 900AST Ser ies 5 Use the [RFL] ke y to find the distance to a resistance fault between two conductors or a conductor and ground. This ke y is used for editing only . Use the [TDR] ke y to activ ate the T ime Domain Reflectometer . Use the [Auto] ke y to activ ate automatic TDR trace analysis.  CAUTION The 900AST[...]

  • Page 6

    3M ™ Advanced Systems T ester 900AST Ser ies 6 TDR Setup The TDR features a setup function that allo ws you to select the type of Coaxial wire to be tested. From the TDR Menu, press the Setup ke y to enter the TDR Setup. Press the select key and the and arrow ke ys to highlight coaxial cable for wire type. Use the select key to mov e to the wire [...]

  • Page 7

    3M ™ Advanced Systems T ester 900AST Ser ies 7 TDR T est Modes Press the or keys to mov e to the desired mode. Press the key to accept the highlighted mode and start the measurement. Single T race Use the TDR Single Trace mode to test a single coaxial wire or circuit.[...]

  • Page 8

    3M ™ Advanced Systems T ester 900AST Ser ies 8 Dual T race Dua l T race is us ed to com pare tw o co axia l c irc uit s a t the sa me tim e (u sua lly a fa ult ed a nd a g ood ci rcui t). Connect the TDR test leads to the (Red and Black jacks) and connect the second TDR test lead set (Blue and Y ellow jacks) to the reference circuit. This mode is[...]

  • Page 9

    3M ™ Advanced Systems T ester 900AST Ser ies 9 Use the and ke ys to highlight the desired stored result. Press the key to display the stored trace on the bottom of the TDR screen and the “li ve” trace on the top. Y ou may move the cursor by using the and ke ys. The control settings for the stored trace can be vie wed by pressing the or keys b[...]

  • Page 10

    3M ™ Advanced Systems T ester 900AST Ser ies 10 Length allo ws you to set the distance (or span) from the left side of the screen to the right side. The left side of the screen is at the end of the BNC test lead and the right side is the farthest distance that can be displayed with the selected length Use the or ke ys to move forward or backward [...]

  • Page 11

    3M ™ Advanced Systems T ester 900AST Ser ies 11 Press the key . The 900AST tester will display the Sav e Results screen as follo ws: Use the blue keys to enter an alphanumeric ID. The ID may hav e up to twelve digits. Whether a number or letter is entered depends on how many times the ke y is pressed. As an example, if the Ohms ke y is pressed on[...]

  • Page 12

    3M ™ Advanced Systems T ester 900AST Ser ies 12 generally cause small upward peaks due to a change in impedance. T o determine if an upward e vent is an impedance change or a main e vent fault you may go to the other end of the coaxial cable and disconnect it. Next, tak e a jumper and short the inner conductor to the outer shield. If you see a la[...]

  • Page 13

    3M ™ Advanced Systems T ester 900AST Ser ies 13 Short Circuit A short circuit (or zero-Ohm resistance fault) will sho w up as the lowest dip on the screen. Y ou cannot see e vents past a short circuit Branch Circuit The beginning of the branch circuit will look lik e a small dip and the end of the branch will look like an open (upward peak). Use [...]

  • Page 14

    3M ™ Advanced Systems T ester 900AST Ser ies 14 Connect the 900AST test leads to the coaxial conductor under test. Press the ke y to access the Soak test from the Resistance screen. Use the ke y to save the activ e resistance to the “Snap Shot” area. Ris ing resis tan ce in th e acti v e box typ ica lly indic ate s moisture while falling resi[...]

  • Page 15

    3M ™ Advanced Systems T ester 900AST Ser ies 15 T o change the coaxial configuration go to the TDR function and press the Setup key . Use the and ke ys and the Blue numeric ke ys to enter the length of cable to analyze. Enter a length longer than the cable being tested but as close as possible to the total length of the cable. When the correct in[...]

  • Page 16

    3M ™ Advanced Systems T ester 900AST Ser ies 16 In this case the low impedance anomaly at 24 inches is detected but not classified. The Auto TDR displays ‘????’ below the trace. Restoring the Aircraft After T esting/ T roubleshooting Disconnect the 900AST TDR test cable from the aircraft wiring. Also, remov e any adapters (if used). Ensure t[...]

  • Page 17

    3M ™ Advanced Systems T ester 900AST Ser ies 17 Aer ospace and Aircra ft Maintenan ce Division T rans portatio n Business 3M Center , Buildin g 220-9W -14 St. Paul, MN 55144-10 00 1-800-3 64-3577 or 651-737 -6501 www .3M.co m/aerospa ce © 3M 2005 78-8135 -6156-6- A 3M is a trademark of 3M Company . Important Notice All statements, technical info[...]