3M QuesTemp 32 manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of 3M QuesTemp 32, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of 3M QuesTemp 32 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of 3M QuesTemp 32. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of 3M QuesTemp 32 should contain:
- informations concerning technical data of 3M QuesTemp 32
- name of the manufacturer and a year of construction of the 3M QuesTemp 32 item
- rules of operation, control and maintenance of the 3M QuesTemp 32 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of 3M QuesTemp 32 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of 3M QuesTemp 32, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the 3M service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of 3M QuesTemp 32.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the 3M QuesTemp 32 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    QUEST emp o 32 User Manual 3M P ersonal Safety Division 3M ™ QUEST emp° ™ Heat Stress Monitors F rom the Robus t C ons tr uc tion F rom the Market Leader ©3 M 2 013. Al l Rig ht s Re ser v ed[...]

  • Page 2

    ii TABLE OF CONTENTS TABLE OF CON TENTS Up and Running ................................................................................................... 1 Che c k W ick an d F i ll N at ur a l We t B ul b ............................................................... 1 Measurements ................................................................[...]

  • Page 3

    iii TABLE OF CONTENTS ACGIH ................................ ........................................................................... 10 United States Navy ........................................................................................ 10 Electrical power research institute (EPRI) ..................................................... 12[...]

  • Page 4

    1 Up and Running Up and Runni ng 1. Make sure the w et bulb’s wick i s clean. Fill the re servoir w ith distilled w ater. 2. Place the QUE STemp in the w ork area in a safe location appr oximately 3.5 feet off the ground. 3. Turn the unit ON . If the batter y voltage display ed during the pow er-on sequence is less than or equa l to 6.4 volt s, r[...]

  • Page 5

    2 Measurem ents Measurement s QUESTemp  32 Th e QU E ST e mp  3 2 po r ta b le a re a h ea t st r e ss mo n it or co mp u te s th e We t B u lb G l ob e Te mp er a tu re ( WBGT ) . T he W BG T i s a n a c cep ted m ea su r e men t f or d e te r mi ni ng the hea t str e s s l ev e l i mp o sed o n a n in d iv i du a l in a g iv en env ir o n m[...]

  • Page 6

    3 Ke y pad Operation Keypad Opera tion The unit operates using a membra ne keypad with 4 keys . The I/O ENTER key responds wh en the key is relea sed while all other keys respond when the key is pressed. I/O Enter The unit turns on w ith a single key press. The uni t turns of f by holding the key down while a countdow n of 3-2-1 occurs in the lower[...]

  • Page 7

    4 Placement for monitoring/testing Placement for monitori ng/testing Th e QU E ST e mp s ho u ld b e p la ce d at a h ei g ht o f 3 .5 f e et ( 1. 1 m) f or st an d ing ind iv i du al s or 2 fe e t ( .6 m ) f o r se a te d in di v id ua l s. T rip o d mo u nt i ng i s re comm e nd ed to g e t th e u ni t aw ay fro m an y th in g th a t m ig ht b lo[...]

  • Page 8

    5 Remote, Sens ors 2 and 3 Relative Humidi ty Sen sor A re la ti v e h umid i ty sen sor i s l o ca t ed i n a c o mpa r t men t in si d e of the sen so r b ar h ou sing . Slo t s in th e ho u si ng a l lo w ai r t o ci r cu la te ar ou nd th e s en so r . Re mot e, Se ns or s 2 a nd 3 Th e to p se n so r b ar ( sen sor 1 ) may be r e mov e d fr o [...]

  • Page 9

    6 Power Options Power Options There are 3 option s for powe ring the QUESTemp: a 9-volt alkaline ba ttery, a NiMH (Nickel Metal Hyd ride) recharge able 6-cell battery pac k, and an AC a dapter. A door on the back of the unit allows the user access to the 9-volt battery. The rechar geable battery pack is located inside o f the unit. If the rechargea[...]

  • Page 10

    7 Power Options NiMH Battery Pack  WARN ING: Recharge batterie s only in a non-hazardo us environment. The NiMH rechar geable battery pa ck is charged in the instrument u sing Quest’s AC adapter #015- 91 0. A discharg ed battery pac k requires an “overnight” charg e of 16 hours. Lea ving the AC adap ter plugged in for extend ed lengths o f[...]

  • Page 11

    8 Specifications Specifications Measurements Globe, dry bulb, w et bulb, WBGTin, WBGTout, WBGT weigh ted average (if 3 sen s or sets), relative hu midity, Heat I ndex , Hu midex . Temperatures g iven in Celsiu s or Fahrenh eit. Languages English, French, Spanish, Italian, German. Housing Designed w ater resistant to a light rain or mist. If rain is[...]

  • Page 12

    9 Product Markings and Special Conditions Battery Life 9V alkaline: 140 ho urs Rechargeab le Nickel Metal Hy dride: 300 hours (Adding additional sensor bars reduces battery l ife.) Charge Time (NiM H Battery Pack) 16 hours (charge in the unit) Safety Approvals ETL, cETL: Cla ss I,II,III Groups A,B,C,D,E,F, G, Temperature code T3 KEMA 04ATEX 1072 X [...]

  • Page 13

    10 APPENDIX A: Heat Expos ures Tables APPENDIX A: He at Exposures Tables ACGIH Screening C riteria for Heat Stress Exposure. WBGT v alues in  C.  NOTE: a ccordi ng to th e ACGIH’s gu idelines, t he tempera ture values represent a work and rest process which is expl ained in t he standards. Please refer t o the ACGIH TL V’s and BEIs for sp[...]

  • Page 14

    11 APPENDIX A: Heat Expos ures Tables PHEL Curves (Total Exposure Time in Hours: Minutes) WBG T( F ) I II III IV V VI 80. 0 >8 :0 0 >8 :0 0 >8 :0 0 8: 00 6: 35 4: 30 81 .0 >8:00 >8:00 >8 :0 0 8: 00 6: 35 4: 30 82 .0 >8:00 >8:00 8: 00 7: 05 5: 25 3: 40 83 .0 >8:00 8: 00 7: 45 6: 25 4: 55 3: 20 84 .0 >8:00 8: 00 7: 05 5:[...]

  • Page 15

    12 APPENDIX A: Heat Exposures Tables Electrical po wer research ins titute (EPRI ) The recommended working hours are shown based on a max imum of four hours. A time of 4:01 indicates greater than 4 hours . WB GT °C L ig h t M od er a te H ea vy 28 4: 01 4: 01 3: 00 29 4: 01 4: 00 2: 00 30 4: 01 3: 00 1: 30 31 4: 01 2: 00 1: 15 32 4: 00 1: 30 1: 00[...]

  • Page 16

    13 APPENDIX B: Accessories APPENDIX B: Accessories Sen sor ar ra y w i th 2 in ch g lo b e 56 - 795 Sen sor ar ra y w i th 6 in ch g lo b e 56 - 780 6 F o ot sh ie ld e d re m ot e se n so r ca b le 53 - 924 25 F oo t sh i e ld ed r e mo te s e n sor c a b le 53 - 925 10 0 Fo o t sh ie l de d re m o te s en so r c a ble 53 - 926 20 0 Fo o t sh ie l[...]

  • Page 17

    14 Customer Service Cus to me r S er vic e Contacting 3M Detec tion Should your 3M equipment need t o be returned for repair or for re calibration, please conta ct the service de partment a t the follow ing number or acces s the online form via the website. For technical i ssues, plea s e contact Tec hnical Support. Should your 3M equip ment need t[...]

  • Page 18

    Personal Safety Division 3M Detection Solutions 1060 Corporate Center Drive Oconomowoc, WI 53066 ISO 9001 Registered Company ISO 17025 Accredited Calibration Lab Customer Service: 262-567-9157 T oll Free: 800-245-0779 www .3m.com/detection 3M is t rad emar k of 3 M Co mpany used u nder lic ense in C an ada Plea se r ecycle. P rin ted in U S A . © [...]