Go to page of
Similar user manuals
-
Clothes Dryer
American Dryer Corp. WDA-530DSi II
33 pages 0.61 mb -
Clothes Dryer
American Dryer Corp. None
76 pages 0.91 mb -
Clothes Dryer
American Dryer Corp. 75 lb
6 pages 2.07 mb -
Clothes Dryer
American Dryer Corp. MDG-75
66 pages 2 mb -
Clothes Dryer
American Dryer Corp. Phase 7 Gas/Steam AD-464
104 pages 5.51 mb -
Clothes Dryer
American Dryer Corp. AD-540
65 pages 2.95 mb -
Clothes Dryer
American Dryer Corp. M31SL
30 pages 1.26 mb -
Clothes Dryer
American Dryer Corp. T30
32 pages 0.93 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of American Dryer Corp. MDG77, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of American Dryer Corp. MDG77 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of American Dryer Corp. MDG77. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of American Dryer Corp. MDG77 should contain:
- informations concerning technical data of American Dryer Corp. MDG77
- name of the manufacturer and a year of construction of the American Dryer Corp. MDG77 item
- rules of operation, control and maintenance of the American Dryer Corp. MDG77 item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of American Dryer Corp. MDG77 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of American Dryer Corp. MDG77, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the American Dryer Corp. service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of American Dryer Corp. MDG77.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the American Dryer Corp. MDG77 item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
MDG31 / MDG51 / MDG77 Installa tion/Oper a tor Manual W ARNING: For your safety the information in this manual must be followed to minimize the risk of fire or explosion and to prevent property damage, personal injury or death. — Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. —[...]
-
Page 2
2 Maytag Co. 1 13430 - 9 “IMPORT ANT NO TE T O PUR CHASER” Information must be obtained from your local gas supplier on the instructions to be followed if the user smells gas. These instructions must be posted in a prominent location near the dryer . FOR Y OUR SAFETY Do not store or use gasoline or other flammable vapors and liquids in the vici[...]
-
Page 3
1 13430 - 9 T elephone: (641) 787-7000 3 T able of Contents ________ List of Acronyms _____________________________ H V A C Heating, V entilating, and Air-Conditioning in wc Inches of Water Column L.C.D. Liquid Crystal Display L.E.D. Light Emitting Diode L .P . Liquid Propane OSHA Occupational Safety and Health Administration U L Underwriters Labor[...]
-
Page 4
4 Maytag Co. 1 13430 - 9 Safety Precautions ____________________ Warning For your safety , the information in this manual must be followed to minimize the risk of fire or explosion and to prevent property damage, personal injury , or loss of life. The dryer must never be operated with any of the back guards, outer tops, or service panels removed. P[...]
-
Page 5
1 13430 - 9 T elephone: (641) 787-7000 5 Warning T o reduce the risk of personal injury , inst all lockable doors to prevent public access to the rear of the dryers. Exhaust duct outlet should be checked periodically for blockages, and if any found, removed. Impor tant A means of restraint must be used to prevent straining of the gas supply when th[...]
-
Page 6
6 Maytag Co. 1 13430 - 9 MA X I MUM C A PA C I T Y (D RY WE I GHT ) 3 0 l b 13. 61 k g T U M BLER DI AM ET ER 3 0 ” 76. 20 cm T U M B L E R D E P T H 27” 68. 58 cm T U M BLE R VOLU ME 11 . 0 4 c u f t 312.62 L T UMB LE R/D RI V E MOT OR 1 / 4 h p 0. 1 8 kW BLO W ER / F AN M O T O R 1 / 2 hp 0. 37 kW D O O R O P E N I N G ( D I A M E T E R ) 19-[...]
-
Page 7
1 13430 - 9 T elephone: (641) 787-7000 7 MDG31 Specifications ________________________________________________________________[...]
-
Page 8
8 Maytag Co. 1 13430 - 9 MA X I MUM C A PA C I TY (D RY WE I GHT ) 5 0 l b 22.68 kg T U M BLER DI AM ET ER 37 ” 93. 98 cm T U M B L E R D E P T H 25- 3/ 4” 65. 41 cm T UMB LE R V OLUME 1 6 . 0 2 c u f t 453. 64 L T UMB LE R/DRI V E MOTOR 1 hp 0. 75 kW BLO WER / F AN M O T O R 1/2 hp 0. 37 kW D OOR OP E NI NG (D I A ME TE R) 2 7 - 3 / 8 ” 69. [...]
-
Page 9
1 13430 - 9 T elephone: (641) 787-7000 9 MDG51 Specifications _________________________________________________________________[...]
-
Page 10
10 Maytag Co. 1 13430 - 9 MA X I MUM C A PA C I TY (D RY WE I GHT ) 7 5 l b 34.02 kg T U M BLER DI AM ET ER 3 7 ” 93. 98 c m T U M B L E R D E P T H 35-1/ 2” 90.17 cm T UM B LE R V OLU ME 2 2 . 0 9 c u f t 625. 52 L TU MB L E R/D RI V E MOT OR 1 h p 0. 75 kW BLO WER / F AN M O T O R 1 /2 hp 0.37 kW D O O R O P E N IN G ( D IA M E TE R ) 2 7 - 3[...]
-
Page 11
1 13430 - 9 T elephone: (641) 787-7000 11 MDG77 Specifications ______________________________________________________________[...]
-
Page 12
12 Maytag Co. 1 13430 - 9 ! Installation Procedures _______________ Installation should be performed by competent professional in accordance with local, state, and country codes. In the absence of these codes, the installation must conform to applicable American National S tandards: ANSI Z223.1-LA TEST EDITION (National Fuel Gas Code) or ANSI/NFP A[...]
-
Page 13
1 13430 - 9 T elephone: (641) 787-7000 13 Domestic Type I (MDG31, MDG51 Only) ! ! ! ! A = 6-inches (15.24 cm) B = 24-inches (60.96 cm) EXAMPLE: For MDG51, 2 unrestricted openings measuring 6-inches by 24-inches (15.24 cm by 60.96 cm) are acceptable. If a closet door is installed: unobstructed air openings are required. The air openings shall be loc[...]
-
Page 14
14 Maytag Co. 1 13430 - 9 ! NOTE 1 Opening from combustible materials must be 2-inches (5.08 cm) larger than the duct (all the way around). The duct must be centered within this opening. NOTE 2 Distance should be 2 times the diameter of the duct to the nearest obstruction. Multiple Dr yer (Common) V enting Impor tant For extended ductwork runs, the[...]
-
Page 15
1 13430 - 9 T elephone: (641) 787-7000 15 NUMB E R OF D RY E RS 4 3 2 1 MI NI MUM C ROSS - SECT I ON AL AR EA SQ I N 120 120 80 54 SQ C M 774.2 774.2 516.1 348 .4 MI NI MUM ROUND DU CT DI AM ET ER I N 12 12 10 8 CM 30. 48 30. 48 25. 4 20. 32 Impor tant No more than 4 dryers should be connected to 1 main common duct. The illustration below shows the[...]
-
Page 16
16 Maytag Co. 1 13430 - 9 Grounding A ground (earth) connection must be provided and installed in accordance with local, state, and national regulations or codes of the country of origin. In the absence of these codes, grounding must conform to applicable requirements of the National Electrical Code ANSI/NFP A NO. 70-LA TEST EDITION, or in Canada, [...]
-
Page 17
1 13430 - 9 T elephone: (641) 787-7000 17 200-240V Application without Neutral ! Caution The dryer must be grounded. A ground lug has been provided for this purpose. Input connection wiring must be sized properly to handle the dryer ’s current draw . This information is printed on the dryer’s data label. Impor tant A strain relief must be used [...]
-
Page 18
18 Maytag Co. 1 13430 - 9 G as Speci fi cat i ons for C E A pproved Dry ers ** Model Gas Ty p e Nom i nal Heati n g V alue Supply Pressure Gro s s Heat Input Fuel Consumpt ion Orifice S iz e Orif ic e (I nj ect or) Qu a n tity Bur ner Pressure Bt u/ ft 3 mb Btu/ hr kW DMS mm mb Natura l ( I 2H /I 2E )1 , 0 0 0 15-30 55, 000 16. 12 1.557 M 3 /H 22 3[...]
-
Page 19
1 13430 - 9 T elephone: (641) 787-7000 19 Piping/Connections CE dryer connections will be B.S.P .T ., all others will be N.P .T . There should be a minimum 6-inch (15.24 cm) clearance between the back guard and the first bend in the gas piping for ease of servicing. It is recommended that a gas shutoff valve be provided to the gas supply line of ea[...]
-
Page 20
20 Maytag Co. 1 13430 - 9 ! ! ! Unre gulated Gas V alve Regulate (govern) gas externally (refer to “Supply Pressure” in chart on page 18) to the correct gas pressure for the gas being used. Operate dryer through 1 complete cycle to ensure proper operation. R e gulated Gas V alve Refer to “Gas Pressure Adjustment” on the following page to ad[...]
-
Page 21
1 13430 - 9 T elephone: (641) 787-7000 21 ! ! Warning (CE Dr yers) This appliance must only be operated with the gas type indicated on the dryer’s data plate. If the appliance is converted (gas type changed), a data plate amendment must be obtained from Maytag. Conversions done improperly can result in a fire or explosion! Gas Pressur e T esting [...]
-
Page 22
22 Maytag Co. 1 13430 - 9 ! ! ! ! ! Installation Water Supply The fire suppression system must be supplied with a minimum water pipe size of 1/2-inch (12.7 mm) and be provided with 40 psi +/- 20 psi (2.75 bar +/- 1.37 bar) of pressure. If the rear area of the dryer or the water supply is located in an area where it will be exposed to cold/freezing [...]
-
Page 23
1 13430 - 9 T elephone: (641) 787-7000 23 ! Note Water column pressure requirements (measured at the pressure tap of the gas valve body) must be verified. Impor tant In most cases there is no regulator provided in an L.P . dryer. The water column pressure must be regulated at the source (L.P . tank), or an external regulator must be added to each d[...]
-
Page 24
24 Maytag Co. 1 13430 - 9 ! ! ! ! ! ! ! ! ! ! ! ! Note When ordering replacement parts from the Maytag distributor or the Maytag Co. be sure to give them the correct model number and serial number so that your parts order can be processed in an expeditious manner. Wa r ranty Infor mation _________________ R etur ning War r anty Cards Before any dry[...]
-
Page 25
1 13430 - 9 T elephone: (641) 787-7000 25 Data Label Infor mation _____________________________________________________________ Standard Label When contacting Maytag, the information on the data label is required to ensure proper service/parts assistance. The data labe l is located at the upper left rear of the dryer behind the back guard. 1. Model[...]
-
Page 26
Part No. 1 13430 9 - 02/ 15/ 0 8 - 0[...]