Energy Tech Laboratories Modular Direct Fired Heaters manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Energy Tech Laboratories Modular Direct Fired Heaters, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Energy Tech Laboratories Modular Direct Fired Heaters one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Energy Tech Laboratories Modular Direct Fired Heaters. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Energy Tech Laboratories Modular Direct Fired Heaters should contain:
- informations concerning technical data of Energy Tech Laboratories Modular Direct Fired Heaters
- name of the manufacturer and a year of construction of the Energy Tech Laboratories Modular Direct Fired Heaters item
- rules of operation, control and maintenance of the Energy Tech Laboratories Modular Direct Fired Heaters item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Energy Tech Laboratories Modular Direct Fired Heaters alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Energy Tech Laboratories Modular Direct Fired Heaters, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Energy Tech Laboratories service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Energy Tech Laboratories Modular Direct Fired Heaters.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Energy Tech Laboratories Modular Direct Fired Heaters item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    April 2006 Rev. 9 FOR YOUR SAFETY The use and storage of gasoline or other flammabl e vapors and liquids in open containers in the vicinity of this appliance is hazardous . Standard and Modular Direct Fired Heaters Installation, Operation, and Maintenance Manual Modular Direct Fired Heater Standard Direct Fired Heater Direct Fired Module Save these[...]

  • Page 2

    TABLE OF CONTENTS WARRANTY ....................................................................................................................... ........................... 3 INSTALLA TION ................................................................................................................... .......................... 4 Mechanical ...[...]

  • Page 3

    3 WARRANTY This equipment is warranted to be free from defe cts in materials and workmanship, unde r normal use and service, for a period of 12 months from date of shipm ent. This warranty shall not apply if: 1. The equipment is not installed by a qualifi ed instal ler per the MANUFA CTURER’S installation instructions shipped with the product, 2.[...]

  • Page 4

    4 INSTALLATION It is imperative that this unit is in stalled and ope rated with the designed airflow, gas, and electrical supply in accordance with this manual. If there are any questions about any items, please call the service department at 1-866-784-6 900 for warranty and technical support issues. Mechanical WARNING: DO NOT RAISE VENTILATOR BY T[...]

  • Page 5

    5 Recom men ded S uppl y Du ctwor k S izes Bl ower Si ze Duct Size St rai ght Duct Lengt h 10 14 x 14 48 i n. 12 16 x 16 54 i n. 15 20 x 20 72 i n. 18 24 x 24 86 i n. 20 26 x 26 108 i n. 25 32 x 32 168 i n. through vertical portion of the ventilator base assembly flange using a minimum of eight (8) lug screws, an chor bolt s, or ot her suita ble fa[...]

  • Page 6

    6 Direct Fired Module Installation Indoor (INLINE) Installation Heat Module Add-On Installation Modular heat units shippe d to add heat onto existin g blower only application s require field mechanical and wiring installation. 1. Remove existing filter intake and lifting lugs from blower section in take side. 2. Attach heat module to blower intake [...]

  • Page 7

    7 Gas Pressure Table Gas Pressure Type Gas Pressure Size 1-3 Inlet Pressure 7 in. w.c. – 14 in. w.c. Size 4-5 Inlet Pressure 7 in. w.c. – 5 psi. Max. Manifold Pressure - Natural Gas 5 in. w.c. maximum Max. Manifold Pressure - Propane 2.5 in. w.c. maximum Gas Connection Sizes Unit Size Gas Pipe Size (NPT) Size 1 ¾” Size 2 1” Size 3 1” Siz[...]

  • Page 8

    8 Copper Wire Ampacity Wire Size AWG Maximum Amps 14 20 12 25 10 30 8 40 6 55 4 70 Electrical Before connecting powe r to the heater, read and understand this entire section of this docume n t. As-built wiring diagrams are furnished with each fan b y the factory, and are atta ched to the door of the unit. Electrical wiring and connections should be[...]

  • Page 9

    9 Remote Control Panel On units shipped with the optional remote control panel , an ele ctrical drop containing th e panel wiring is provided with the heate r. There is a terminal strip in side the remote panel th at matches the terminals in the heater unit. The remote panel shoul d be wired as shown below. BL YW RD BK PK RD WH OR BR GY BK RD YW PK[...]

  • Page 10

    10 Pilot Assembly OPERATION Prior to starting up or operating the heater, che ck al l fasteners for tightness. In particular, che ck the set screw in the wheel hu b, bearings and t he fan sheav es (pulleys). With p ower and gas to the heater OFF or prior to connecting ventilator to po wer, turn the fan whee l by ha nd to be sure it is not st riking[...]

  • Page 11

    11 Maxitrol M511 and M611 Low Fire Bypass Screw Mod Valve Voltage Summary Volts DC Firing Mode 0 to 5 VDC Low Fire 5 to 15 VDC Modulation 15 to 20 VDC High Fire Maxitrol MR212 Lo w Fire Bypass Scre w Average Man ifold Pressure vs. Firing Rate/Ft. of Bu rn er -1.0 0 0.00 1.00 2.00 3.00 4.00 5.00 6.00 0 100000 2000 00 300000 400000 50000 0 600000 Fi [...]

  • Page 12

    12 Adju st pilot fla me. Lock u ni t in to hig h f i re. Ad j us t incomi ng gas pressur e. Doe s h igh fi r e pr oduce at least a 70°F temp rise an d produce the correct m anifold pressu re? A djust h igh fire No Lock unit in to low fire. Yes Does thin flame fill ent i re b urne r le ng t h? Adju s t low fire. Sett in g i n comi n g p ressu re: P[...]

  • Page 13

    13 Maximum RPM and HP Chart Blower Size Maximum RPM Maximum HP 10” 1800 2 12” 1500 3 15” 1400 5 18” 1200 5 20” 1000 10 25” 900 20 Pulley Adjustment Illustration Setscrew Torque Thread Size Torque (IN/Lb) No. 10 33 1/4” 80 5/16” 156 3/8” 275 7/17” 384 1/2” 600 Final Start Up Procedure 1. With the air and burner systems in full [...]

  • Page 14

    14 Pulley Combination Chart Motor RPM 1725 1/3 to 1-1/2 H P MOTOR PULL EY Dd1 Dd2 Pd1 Pd2 AX BELTS 1VL34 1.9 2.9 2 3 Open Closed BLOWER PULLEY DATUM DIAMETER PITCH DI A METER 5 4 1/2 4 3 1/2 3 2 1/2 2 1 1/2 1 1/2 0 AK114 11 11.2 308 323 339 354 370 385 400 416 431 447 462 1/3 to 2 HP MOTOR PULL EY Dd1 Dd2 Pd1 Pd2 AX BELTS 1VL40 2.4 3.4 2.6 3.6 Open[...]

  • Page 15

    15 Flame Safety Controller Air Flow Switch DC Flame Signal DC Voltage Flame Status 0 to 5 VDC No Flame 6 to 11 VDC Weak Flame 12 to 18 VDC Strong Flame Sequence of Operation The direct-fired heater is most easily understood wh en broken down into smaller individual system s. There are two main systems, a make -up air fan and a heater. T he make-up [...]

  • Page 16

    16 Maxitrol 14 Amplifier High Temperature Limit airflow switch to close. The high airflo w switch prot ects against profile plate fail ures that cause excessive airflow through the burne r. In the ev ent that the pressure drop across th e burner is not in the range of the airflow switch, gas flow to the burne r is stopped by the Flame Safety Contro[...]

  • Page 17

    17 9 Begins Pilot Trial For Ignition and turns on PTFI LED 9 The pilot g as solenoid valve is opene d, the sp ark igniter begins spar king, and the flamerod sensor watches for flame initiation 9 When flame is establishe d, the FLAME LED is illuminated and m a in valve opens and the FSC powers the Maxitrol system and gas flow begin s modulating 9 Th[...]

  • Page 18

    18 Components The following image and list outlines the typical di rect fired heater components and their fun ctions. 1. Gas Inlet – Main gas supply conn ection 2. Motor Starter – Contactor with overload protec tion to start and prot ect motor. 3. Freeze-Stat Thermosta t (Optional) – De-energizes blo wer motor if the discharge air temperature[...]

  • Page 19

    19 Remote Panel Option The Remote Panel is a device used to control the ope r ation of the heater from a remote location. This unit is available in both a “2 Position” or “3 Position ” configuration and with or with out a cooling output. It also will accommodate both the Maxitrol discharge te mperature dial and the Maxitrol space sensing Se[...]

  • Page 20

    20 Troubleshooting The following tables list cause s and corrective actions for possibl e problems wit h direct fired heater units. Review these lists prior to consulting manufacture r. Airflow Troubleshooting Chart Problem Potential Cause Corrective Action Blown fuse or open circuit breaker Replace fuse or reset circuit breaker and check amps Disc[...]

  • Page 21

    21 Burner Troubleshooting Chart Problem Potential Cause Corrective Action Main gas if off Open main gas valve Air in gas line Purge gas line Dirt in pilot orifice Clean orifice with compressed air Gas pressure out of range Adjust to proper gas pressur e Pilot valve is off Turn pilot valve on Pilot orifice fitting leak Tighten pilot orifice Excessiv[...]

  • Page 22

    22 Remote Panel Troubleshooting Chart Light Indication Condition Possible Cause Bad voltage to unit Main disconnect i n “OFF” Position Circuit breaker tripped No Lights Power not available to Remote Panel Bad main transformer Proper unit Off Operation No problem Manual/Off/Auto Switch in “Off” Position (3 Position Remo te Panels Only) Impro[...]

  • Page 23

    23 Is Freeze-Stat open? Adjust or Replace Is end switch on Moto ri ze d Damp er closed? Adjust or Replace actuator YES YES NO Nothing Happe ns Is Overload tripped on starter? Reset & m easure FLA of m otor. Is it higher than rating? Adjust or change Pull ey NO NO YES Blower runs but there is no heat Is the air fl ow LED on Flame Saftey ill umin[...]

  • Page 24

    24 Flame Safety Service Guide (Airflow LED may or may not be illuminated)[...]

  • Page 25

    25 Flame Safety Service Guide (continued) (Airflow LED may or may not be illuminated)[...]

  • Page 26

    26 MAINTENANCE To guarantee trouble fre e operation of this heater, th e man ufacturer sugge sts following these guid elines. Most problems associated with f an failures are directly related to poor servi ce and maintenance. Please record any mainte nance or service performe d on this fan in the docum ent ation section located at the end of this ma[...]

  • Page 27

    27 Burner Orifice Drill Size Orifice Drill Size Gas Port 31 Air Port 43 2 weeks after startup 1. Belt tension should be checked after the first 2 weeks of fan ope ration. Belts tend to stretch and settle into pulleys after an in itial start-up sequence. Do not tension bel ts by changing the setting of the motor pulley , this will change the fan spe[...]

  • Page 28

    28 April 2006 Rev. 9 Start-Up and Maintenance Documentation START-UP AND MEASUREMENTS SHOULD BE PERFORMED AFTER THE SYSTEM HAS BEEN AIR BALANCED AND WITH TH E HEAT ON (Warranty will be void without completion of this form) Job Information Job Name Service Company Address Address City City State State Zip Zip Phone Number Phone Number Fax Number Fax[...]