Field Controls SWGII manual

1
2
3
4
5
6
7
8
9
10
11
12

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Field Controls SWGII, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Field Controls SWGII one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Field Controls SWGII. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Field Controls SWGII should contain:
- informations concerning technical data of Field Controls SWGII
- name of the manufacturer and a year of construction of the Field Controls SWGII item
- rules of operation, control and maintenance of the Field Controls SWGII item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Field Controls SWGII alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Field Controls SWGII, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Field Controls service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Field Controls SWGII.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Field Controls SWGII item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    SIDE WALL POWER VENTER KIT Model : SWG, SWGII & SWG Stainless Series * Patented TYPICAL VENTING SYST EM COMPONENTS 1 - SWG Series Power Venter 1 - CK Series Control Kit (sold separately) OPTIONAL SYSTEM COMP ONENTS SWG S ERIES T HROUGH - W ALL E XTENSION K IT F or installation in wall thickness over 8 inches. Models PEK - 4 through PEK - 8 are [...]

  • Page 2

    Page 2 CONTROL KITS CK - 20F/HWK: For operation with 30 or 750 millivolt gas - fired water heaters, gas - fired space heaters and gas - fired pool or spa heaters with an internally mount ed thermostat. Includes a fixed post purge. CK - 21: For operation with gas - fired instantaneous water heaters with a pressure tap port in the burner manifold. CK[...]

  • Page 3

    Page 3 INSTALLATION OF SWG POWER VENTER ( See Table 1) Table 1 UNIT SIZING CHART OIL GAS MAXIMUM EQUIVALENT FEET OF VENT PIPE MAX* OIL GPH INPUT MAX** BTU/HR. IMPUT AT MAX BTU/HR INPUT AT 60% OF MAX BTU /HR INPUT VENTING WITH VENT PIPE SIZE MODEL 21 80 3” 50 100 4” N/A 70,000 --- --- --- SWG - 3 --- 23 3” 35 100 4” 1.10 170,000 65 100 5” [...]

  • Page 4

    Page 4 P ROCEDURE F OR C ALCULATING T OTAL E QUIVALENT P IPE L ENGTH I N F EET 1. Calculate the total equivalent feet for each type of fitting used in the venting system from the chart below. 2. Calculate the total amount of feet for the st raight lengths of vent pipe. 3. Add the equivalent feet for the fitting with the total amount of feet of stra[...]

  • Page 5

    Page 5 Figure 2 Figure 3 Figure 4 3. After determining the location of the venting system termination point (see Diagram A), cut a square hole through the wall 1 " larger than the outer pipe diameter of the power venter. Mount the power venter through the wall, keeping the outer pipe centered in the hole. (See Figure 3) Fasten the power venter[...]

  • Page 6

    Page 6 Figure 5 C ONNECTING P OWER V ENTER T O A PPLIANCE Venting system should be installed and supported in accordance with the National Flue Gas Code A.N.S.I.Z223.1, or in accordance with any local codes. A vent pipe connector shall be supported for the design and weight of the material employed, to maintain clearances, prevent physical damage a[...]

  • Page 7

    Page 7 Figure 6 Figure 7 Figure 8 CLASS B AND CLASS L DOUBLE WALL VENT PIP E INSTALLATION (Follow vent pipe manufacturer's listed or recommended cleara nces from combustible material) 1. Using a hand crimper or a like device, crimp the inner pipe of the S WG power venter approximately 1" long. (See Figure 7) 2. Attach the vent pipe over t[...]

  • Page 8

    Page 8 GENERAL INSTALLATION INSPECTION Recommended procedures for safety inspection of an appliance in accordance with the National Fuel Gas Code A.N.S.I.Z223.1. The following procedure will help evaluate the venting system. It is intended as a guide to aid in determining that the venting system is properly installed and is in a safe condition for [...]

  • Page 9

    Page 9 Figure 9 Figure 10 REPLACEMENT PARTS Should the motor or blower wheel need replacing, the following replacement items are available. The Repair Motor Assembly contains the Motor and Blower Wheel factory assemble to a mounting bracket. PART NUMBERS MODEL REPAIR MOTOR ASSEMBL Y BLOWER WHEEL SWG - 3 46196601 46131800 SWG/SWGII - 4HD SWG - 4s 46[...]

  • Page 10

    Page 10 Figure 11 Figure 12 Figure 13 Figure 14 I NSTALLATION 1. Insert the blower wheel through the hole in the front plate of the power venter housing. (See Figure 11) 2. Using two nails or awls, align the two center holes of the motor mount bracket and cover plate. Locate the motor assembly into position by sliding the assembly over the mounting[...]

  • Page 11

    Page 11 INITIAL BURNER AND V ENTING SYSTEM OP ERATIONAL INFORMATIO N List the following for each operating appliance on the sidewall venting system, as a guide for tune - up or service information annually. DATE: FOR GAS FIRED EQUIPMENT Heating Appliance BTU/HR Input Gas Valve Operation Pressure Vent System Draft Above Draft Hood or Before Barometr[...]