Go to page of
Similar user manuals
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Galaxy Metal Gear 5000RS-2W, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Galaxy Metal Gear 5000RS-2W one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Galaxy Metal Gear 5000RS-2W. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Galaxy Metal Gear 5000RS-2W should contain:
- informations concerning technical data of Galaxy Metal Gear 5000RS-2W
- name of the manufacturer and a year of construction of the Galaxy Metal Gear 5000RS-2W item
- rules of operation, control and maintenance of the Galaxy Metal Gear 5000RS-2W item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Galaxy Metal Gear 5000RS-2W alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Galaxy Metal Gear 5000RS-2W, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Galaxy Metal Gear service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Galaxy Metal Gear 5000RS-2W.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Galaxy Metal Gear 5000RS-2W item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
5 5 0 0 0 0 0 0 R R S S -2 2 W W P P L L U U S S S S E E R R I I E E S S VEHICLE SECURITY SYSTEM WITH REMOTE START PRODUCT MANUAL[...]
-
Page 2
L L i i m m i i t t e e d d L L i i f f e e t t i i m m e e W W a a r r r r a a n n t t y y This vehicle security system is warranted to the original purchaser , to be free from defects in material and workmanship. The manufacturer will rep air or replace at its option, and free of charge for the first twelve (12) months, any part that proves defec[...]
-
Page 3
1. About Y our System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Page 1 2. Remote T r ansmitters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .P age 2 Remote T r ansmitter Description . . . . . . . . . . . . . . . . . . . .[...]
-
Page 4
[...]
-
Page 5
The ScyT ek Galaxy 5000RS Plus is a combination vehicle security and remote starting system featuring a built-in "ScyNet Network Port" that allows direct connection of optional accessory modules and a PC interface offering expanded system operation. W i t h p r oper installation this system will provide superior protection and performance[...]
-
Page 6
Standard Remote Transmitter Description The Galaxy 5000RS Plus is compatible with the optional 5-but ton Remote T r ansmitters used to control system operations. Note : Using the optional PC or Pock et PC interface with the network software, it is possible to reconfigure the functionality of the tr ansmitter buttons. The standard (default) setting [...]
-
Page 7
Adding/Replacing Transmitters T o replace lost or stolen transmitters or to add additional tr ansmitters into the system, have all desired transmit ters ready and f ollow the steps below . Note : Up to 4 tr ansmitters can be programmed to operate the system. T o erase any previously stored transmit ter codes, be sure to progr am all 4 transmitter m[...]
-
Page 8
Page 4 - Galaxy 5000RS-2W Plus 2-way LCD Remote Transmitter Description The Galaxy 5000RS-2W Plus is supplied two 2- way LCD remote transmit ters, of fering increased r ange and confirmation of any activated features. Button 1 Arms and Disarms the system and when held for 2 seconds, activates the system’ s Panic feature. Button 1 also locks/unloc[...]
-
Page 9
Galaxy 5000RS-2W Plus - Page 5 LCD Transmitter Battery Replacement Y our Galaxy R emote T ransmit ter uses a 1.5 volt AAA alkaline battery , which will require replacement in time. Depending on the amount of use, the bat tery may last up to six months before it needs replacement. When the battery needs replacing, the system’ s operating range wil[...]
-
Page 10
Page 6 - Galaxy 5000RS-2W Plus 4. When the desired time is displayed, press Button 5 to store. · The remote will play a melody to indicate the alarm clock has been set. T o disable the automatic start / auto activ ate f unction: 1. Press and hold But tons 2 and 3 until the remote beeps four times. · The fan and clock will be shown indicating auto[...]
-
Page 11
Galaxy 5000RS-2W Plus - Page 7 The PSV or passive function allows the passive arming mode to be enabled or with the transmit ter . Note: This feature may not be available on all systems. T o enable or disable the passive arming mode: 1. Press and hold Button 5 until the display shows PSV . · The transmitter will beep four times. 2. Release Button [...]
-
Page 12
Page 8 - Galaxy 5000RS-2W Plus Remote Arming The system monitors 6 independent areas ( zones ) while armed: doors, hood, trunk, shock sensor , optional sensor input, and the network port for future expansion. T o Arm the System: 1. T urn off the ignition. 2. Press Button 1. · The siren will chirp once.* · The doors will lock. · The parking light[...]
-
Page 13
Galaxy 5000RS-2W Plus - Page 9 Tamper Alert If the system was triggered while away , the LED will flash to indicate which zone triggered the system after disarming and turning on the ignition. The LED indication will repeat 8 times. LED Flashes (60 seconds): 1 flash = optional sensor 2 flashes = shock sensor 3 flashes = network based sensor 4 flash[...]
-
Page 14
Page 10 - Galaxy 5000RS-2W Plus Panic Mode In the event of an emergency the transmitter’ s remote Panic feature can be used to instantly trigger the alarm. T o activ ate the Panic Mode: 1. Press and hold Button 1 for 3 seconds. · The alarm will sound. · The parking lights wil l flash. · The doors will unlock* allowing access to the vehicle. 2.[...]
-
Page 15
Galaxy 5000RS-2W Plus - Page 11 T o set the Emergency Override Code: 1. T urn on ignition. 2. Within 5 seconds, press the v alet switch 5 times. · The siren will provide one long chirp, indicating that you have entered Programming. 3. Press the valet switch 4 times. · The siren will chirp each time the valet switch is pressed. 4. Within 5 seconds[...]
-
Page 16
Page 12 - Galaxy 5000RS-2W Plus Remote Starting T o Remote Start the S ystem: 1. Be sure the system is not in V alet Mode. 2. Press and hold Button 4 f or three seconds. · The parking lights wil l flash 4 times and turn on. · The Siren will chirp 4 times. · The engine will start and run f or the duration of its programmed Run Time.* · The heate[...]
-
Page 17
Galaxy 5000RS-2W Plus - Page 13 Automatic Start Mode The Automatic Start Mode allows the vehicle to automatically start the vehicle every one or two hours and run for the preset Run Time. T o turn on Auto Cold Starting: 1. T urn Ignition switch Off and wait for 3 seconds. 2. T urn Ignition switch On and Of f three times ending with Ignition in Of f[...]
-
Page 18
Page 14 - Galaxy 5000RS-2W Plus E E x x t t e e n n d d e e d d F F e e a a t t u u r r e e s s Ignition Door Locking F or added safet y , the Ignition Door Locking feature allows vehicles equipped with power door lock systems to automatically lock the doors when the ignition is turned on. If a door is open when the ignition is turned on, the Ignit[...]
-
Page 19
Galaxy 5000RS-2W Plus - Page 15 1. Thoroughly read and become familiar with the installation instructions bef ore beginning the installation. 2. Review system contents: Main Unit T wo 5-Button Remote T r ansmitters Siren Shock Sensor Harnesses • 6-Pin starter harness • 20-Pin main harness • 4-Pin shock sensor harness • 3-Pin door lock harne[...]
-
Page 20
Page 16 - Galaxy 5000RS-2W Plus Mounting the Control Unit The control unit must only be mounted in the interior of the vehicle. Do not mount the main unit in the engine compartment. Choose a mounting location that will not be easily accessible to a thief , and will not interfere with the operation of any vehicle components such as foot pedals, stee[...]
-
Page 21
Galaxy 5000RS-2W Plus - Page 17 S S y y s s t t e e m m W W i i r r i i n n g g 6-Pin Starter Harness Pin 1 RED WIRE A : Main Power Input A (+). Connect to the battery or constant power wire at the ignition switch with a minimum 30 Amp supply . R emo v e the fuse unti l the instal lation is complete and al l wiring is check ed. Pin 2 RED WIRE B : M[...]
-
Page 22
Page 18 - Galaxy 5000RS-2W Plus when the door is open. This t ype of door circuit is usually found on Ford vehicles. Pin 12 GREEN WIRE : Negative Door Input (-). Connect to the door switch circuit wire that shows ground when the door is open. Pin 13 WHITE/BLACK WIRE : Hood Pin Input (-). Connect the to the hood pin switch. The switch must provide a[...]
-
Page 23
Galaxy 5000RS-2W Plus - Page 19 Jumper Selection Carefully separate the top and bottom halves of the main unit case. Once the cover is removed, the parking light polarity jumper will be visible next to the parking light relay . Set the jumper f or the correct polarity output as described below, then reassembly the main unit case. Parking Light Outp[...]
-
Page 24
Page 20 - Galaxy 5000RS-2W Plus Entering System Programming This system is compatible with both the optional LCD transmitter or the standard AM transmitter , all system programming can be perf ormed using either one. T o enter S ystem Programming: 1. T urn on ignition. 2. Within 5 seconds, press the v alet switch 5 times. · The siren will provide [...]
-
Page 25
Galaxy 5000RS-2W Plus - Page 21 5. Ignition Door Unlocking. Selects whether or not the system automatically unlocks the doors when the ignition is turned off . The Ignition Door Locking feature may be programmed to unlock all doors or the driver’ s door only . If driver’ s door only is selected, the optional Passenger Unlock wire must be connec[...]
-
Page 26
Page 22 - Galaxy 5000RS-2W Plus for this feature. 10. Ignore Open Door Report. Bypasses the open zone warning chirps for vehicles equipped with a residual dome light circuit that remains on f or a period of time after closing the door . 11. Aux 2 Auto Activate with Arm. When selected, the Auxiliary 2 output wil l activate when the system is armed. [...]
-
Page 27
Galaxy 5000RS-2W Plus - Page 23 22. Ignition 2 Relay Program. Selects one of three operating modes for the Ignition 2 rela y output: Ignition 2, Accessory 2, or Starter 2. 23. Horn Output. When set for Horn Output the horn wire will pulse when the alarm is triggered. When Ignition 3 Output is selected, the output will activate during remote start t[...]
-
Page 28
Page 24 - Galaxy 5000RS-2W Plus W W i i r r i i n n g g D D i i a a g g r r a a m m s s TO POSITIVE DOME LIGHT +12V Black/White (-) DOME LIGHT OUTPUT TO NEGATIVE DOME LIGHT +12V Black/White (-) DOME LIGHT OUTPUT P ositive Dome Light Negative Dome Light TO POSITIVE HORN WIRE +12V Brown/White (-) HORN OUTPUT TO NEGATIVE HORN WIRE +12V Brown/White (-)[...]
-
Page 29
Galaxy 5000RS-2W Plus - Page 25 Negative T rigger P ositive T rigger Re verse Polarit y V acuum Adding Actuators F ollow the diagrams below for connecting basic door lock systems. For T wo Stage door lock systems (separately unlocks driv er and passenger doors) see f ollowing pages. D D o o o o r r L L o o c c k k D D i i a a g g r r a a m m s s Gr[...]
-
Page 30
Page 26 - Galaxy 5000RS-2W Plus T T w w o o S S t t a a g g e e D D o o o o r r L L o o c c k k D D i i a a g g r r a a m m s s T wo Stage Negativ e T rigger T wo Stage P ositive T rigger The Galaxy 5000RS Plus is equipped with a dedicated Passenger Unlock output allowing T wo Stage Door Lock oper ation. When connected as shown below , disarming th[...]
-
Page 31
Galaxy 5000RS-2W Plus - Page 27 T T w w o o S S t t a a g g e e D D o o o o r r L L o o c c k k D D i i a a g g r r a a m m s s c c o o n n t t ’ ’ d d T wo Stage R everse Polarit y T wo Stage Adding Actuators[...]
-
Page 32
Page 28 - Galaxy 5000RS-2W Plus FCC ID: OARRXAM2000 This device complies with P art 15 of FCC Rules. Operation is subject to the following two conditions: 1) This device may not cause harmful interference. 2) This device must accept any interference received, including interference that may cause undesired operation T T e e c c h h n n i i c c a a [...]
-
Page 33
Galaxy 5000RS-2W Plus - Page 29 S S t t a a r r t t e e r r D D i i a a g g n n o o s s t t i i c c s s Starter doesn’ t start and Side Lights flash: 3 Times - Engine RPM not detected Hood T rigger is active 4 Times - Br ake T rigger is active 5 Times - Unit is in V alet (service) mode, and start is disabled.[...]
-
Page 34
Page 30 - Galaxy 5000RS-2W Plus[...]
-
Page 35
Galaxy 5000RS-2W Plus - Page 31 N N o o t t e e s s[...]
-
Page 36
ScyTek Electronics 11627 Cantara Street Unit B North Hollywood, CA 91605 © ScyT ek Electronics 2004 Galaxy 5000RS-2W r3 8/04 W W i i r r i i n n g g D D i i a a g g r r a a m m ScyNet Blue Star t (-) Green Emergency brake(-) Antenna Shock Sensor LED V alet Switch Gr ee n L oc k o ut pu t (- ) 5 00mA R ed +12V relay power output 100mA Bl u e Unlock[...]