Go to page of
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of GE Monogram ZTX, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of GE Monogram ZTX one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of GE Monogram ZTX. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of GE Monogram ZTX should contain:
- informations concerning technical data of GE Monogram ZTX
- name of the manufacturer and a year of construction of the GE Monogram ZTX item
- rules of operation, control and maintenance of the GE Monogram ZTX item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of GE Monogram ZTX alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of GE Monogram ZTX, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the GE Monogram service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of GE Monogram ZTX.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the GE Monogram ZTX item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
g 62 R - 2 000 C 7/02 ZTX SERIES 40-400 Amps GE Zenith Controls Operation and Maintenance Manual[...]
-
Page 2
P age Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 ii How to Remove the Cover . . . . . . . . . . . . . . . . . . . 1 1 Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 2 Equipment Inspection and Storage . . . . . . . . 1 2 Final Equipment Inspection . . . . . . . . . . . . . . 1 2 Mounting [...]
-
Page 3
■ ■ GE Zenith Controls 1 ■ ■ ZTX Operation and Maintenance Manual (62 R - 2 000) Ho w to Remo ve the Co ver D ANGER HAZARDOUS V OL T AGE Will shock, burn or cause death. Do not remove cover until ALL power is disconnected. Re-installation of cover is required after maintenance or service. Loosen but do not remove four cover screws. Lift cov[...]
-
Page 4
■ ■ 2 GE Zenith Contr ols ■ ■ ZTX Operation and Maintenance Manual (62 R - 2 000) Each GE Zenith transfer switch is factory wired and tested. A complete information package is furnished with each switch which includes: a. Sequence of operation. b. Description and operation of all accessories supplied. c. Power panel connection diagram and s[...]
-
Page 5
■ ■ GE Zenith Controls 3 ■ ■ ZTX Operation and Maintenance Manual (62 R - 2 000) GENERA TOR TERMINALS N BR UTILITY TERMINALS LOA D TERMINALS T1 T2 T3 N1 N3 E1 E3 E2 N2 T = Load N = Utility E = Generat or CONTROLLER ENGINE ST ART OPTIONAL A4 CONT ACT OPERA TES WHEN IN UTILITY POSITION OPTIONAL A3 CONT ACT ?[...]
-
Page 6
■ ■ 4 GE Zenith Contr ols ■ ■ ZTX Operation and Maintenance Manual (62 R - 2 000) Installation (cont’ d) Control Connections Connecting Engine Start may cause Generator to start. Before connecting, turn Generator OFF . With the Generator breaker open and the Generator control switch off, install the Generator start connections. Engine Sta[...]
-
Page 7
■ ■ GE Zenith Controls 5 ■ ■ ZTX Operation and Maintenance Manual (62 R - 2 000) Installation (cont’ d) D ANGER HAZARDOUS V OL T A GE (Can Cause Se vere Injur y or Death) T urn OFF all pow er before installation, adjustment, or remov al of transfer switc h or any of its components. A TTENTION! This applies only to the switc hes with the R[...]
-
Page 8
■ ■ 6 GE Zenith Contr ols ■ ■ ZTX Operation and Maintenance Manual (62 R - 2 000) Utility Pic kup V oltage 90% Nominal Line V oltage Utility Dropout V oltage 80% Nominal Line V oltage Utility Pic kup Frequency 90% Nominal Line Frequency (T) Timer/Delay to Utility 5 minutes* (U) Timer/Engine Cool Down 5 minutes* Factor y Set tings Functional[...]
-
Page 9
■ ■ GE Zenith Controls 7 ■ ■ ZTX Operation and Maintenance Manual (62 R - 2 000) RM 4 Contr ol Interface ( Optional ) Optional Pushbut tons F . Generator Start/Stop push button. Pressing and holding this button for approximately 5 seconds will cause the generator to start. Pressing this button a second time will stop the generator . G. Exer[...]
-
Page 10
■ ■ 8 GE Zenith Contr ols ■ ■ ZTX Operation and Maintenance Manual (62 R - 2 000) Automatic T ransfer Generator T esting (One T ime T est) V erify that the transfer switch UTILITY available and position LED s are illuminated. Press and hold the GENERA T OR ST ART / ST OP button and the TRANSFER button for 5 seconds. This will cause the gene[...]
-
Page 11
■ ■ GE Zenith Controls 9 ■ ■ ZTX Operation and Maintenance Manual (62 R - 2 000) 208 V 1 2 A B 220 V 1 2 A B 240 V 1 2 A B JP ( CDT SELECT ) RM 4 Contr ol Interface ( Optional ) (cont’ d) 7 Da y 4 5 6 BA 14 Da y 4 5 6 BA 21 Da y 4 5 6 BA 28 Da y 4 5 6 BA * Pressing and releasing the generator Start/Stop button will cance[...]
-
Page 12
■ ■ 10 GE Zenith Contr ols ■ ■ ZTX Operation and Maintenance Manual (62 R - 2 000) Oil Pressure S ensor Input (Oil pressure contact to be normally open, held closed by adeq uate oil pressure) Approximately five seconds after emngine starter signal is sent, if terminal X3 is open to ground or returns to open state thereafter the generator St[...]
-
Page 13
■ ■ GE Zenith Controls 11 ■ ■ ZTX Operation and Maintenance Manual (62 R - 2 000) Example S ystems Circuit Breaker Main Breaker Panel All Loads Utility Source Transfer Switch Circuit Breaker Generator Source Loads Utility Panel Utility Source Transfer Switch Loads Circuit Breaker Distribution Panel Generator Sourc[...]
-
Page 14
■ ■ 12 GE Zenith Contr ols ■ ■ ZTX Operation and Maintenance Manual (62 R - 2 000) T ypical Diagrams E 3 N 2 CCN SN SCOM SE E2 N1 N2 CCE E1 OPTIONAL 3 E 2 N3 2 4 1 5 6 10 1 3 P o w er Circuit Sc hematic P o w er P anel Lay out Interconnect Plug[...]
-
Page 15
■ ■ GE Zenith Controls 13 ■ ■ ZTX Operation and Maintenance Manual (62 R - 2 000) T r oubleshooting Symptom P ossible Cause Corrective A ction Generator will not start P timer has not lapsed See factory set tings on Page 6 Generator control switc h not in Auto Refer to generator instruction manual Engine Start contact not wired to generator[...]
-
Page 16
■ ■ 14 GE Zenith Contr ols ■ ■ ZTX Operation and Maintenance Manual (62 R - 2 000) T r oubleshooting (cont’ d) Generator Failed to Star t ( GFS Timeout) 2 Flashes + 2 Missing Generator Under -Speed Fault 3 Flashes + 2 Missing Generator Over -Speed Fault 4 Flashes + 2 Missing Generator Over -T emperature Fault 5 Flashes + 2 Missing Generat[...]
-
Page 17
■ ■ GE Zenith Controls 15 ■ ■ ZTX Operation and Maintenance Manual (62 R - 2 000)[...]
-
Page 18
GE Industrial Systems – Power Equipment Business 830 W . 40 th Street, Chicago, IL 60609 USA 773 299-6600, Fax: 630 850-6899 www .zenithcontrols.com g GE Zenith Controls[...]