Go to page of
Similar user manuals
-
Fryer
Henny Penny OFE-341
8 pages 0.99 mb -
Fryer
Henny Penny PFE-500
12 pages 0.57 mb -
Fryer
Henny Penny OE/OG 301/302/303
5 pages 0.31 mb -
Fryer
Henny Penny PRESSURE FRYERS 500
66 pages 3.41 mb -
Fryer
Henny Penny OGA-342
2 pages 0.07 mb -
Fryer
Henny Penny PFG-600 Gas
2 pages 0.23 mb -
Fryer
Henny Penny OE-301/302/303
2 pages 0.12 mb -
Fryer
Henny Penny 303
18 pages 2.32 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Henny Penny OE 301, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Henny Penny OE 301 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Henny Penny OE 301. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Henny Penny OE 301 should contain:
- informations concerning technical data of Henny Penny OE 301
- name of the manufacturer and a year of construction of the Henny Penny OE 301 item
- rules of operation, control and maintenance of the Henny Penny OE 301 item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Henny Penny OE 301 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Henny Penny OE 301, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Henny Penny service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Henny Penny OE 301.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Henny Penny OE 301 item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
enny This section provides the installation instructions for the Henny Penny Fry Station. Installation of the unit should be performed only by a qualified service technician. Do not puncture the unit with any objects such as drills or screws as component damage or electrical shock could result. The Henny Penny Fry Station has been tested, inspected[...]
-
Page 2
The proper location of the Fry Station is very important for operation, speed, and convenience. The location of the fiy station should allow clearances for servicing and proper operation. Choose a location which will provide easy loading and unloading without interfering with the final assembly of food orders. Operators have found that frying from [...]
-
Page 3
When installing the gas fry station do not attach an exten- sion to the gas flue exhaust stack. This may impair proper operation of the burner, causing malfunctions and possible negative back draft. The gas fry station is factory available for either natural or propane gas. Check the data plate inside the front door of the cabinet to determine the [...]
-
Page 4
T INIMU~I PULL of equip- ment away from wall permissible for accessi- bility to Quick Disconnect Device. AVOID SHARP BENDS AND KINKS when pulling equipment away from wall. (Max- imum pull will kink ends, even if installed properly, and reduce Connector life.) ~ QUICK DISCON. NECT DEVICE while extended at MAXIMUM PULL NOT ADVISED WHILE CONNECTED Cou[...]
-
Page 5
A standard one inch, black steel pipe and malleable fittings should be used for gas service connections. Do not use cast iron fittings. Although one inch size pipe is‘reconunended, piping should be of adequate size and installed to provide a supply of gas sufficient to meet the maximum demand without undue loss of pressure between the meter and t[...]
-
Page 6
The following steps provide the pilot PROCEDURE lighting procedure: 1. Open doors and open gas shut-off valve. (see illustrations) 2. The gas cock dial has a dual function: a. Complete control of gas to the pilot and main burner. b. When in the pilot position, it is the reset mechanism for the automatic pilot. 3. Partially depress and turn the cont[...]
-
Page 7
Depress lightly and turn manual lever on gas valve to the OFF position. The gas pressure regulator on the automatic gas valve is factory set as follows: @ Natural: 3.5 inches water column. * Propane 10 0 inches water column. e 120 V, 50/60 Hz., 12 A, 1 PH 0 230 V, 50/60 HZ., 6 A, 1 PH The gas fry station requires a 3 wire grounded service. I W ING [...]
-
Page 8
I The OE-301/302/303 is available from the factory wired 208, or 220/240 volts, 50 or 60 hertz source. Refer to the table below for supply wiring and fusing. Volts Phase KW Amps 208 3 11.25 31 208 3 13.50 38 220/240 3 11.25 30132 2201240 3 13.50 33135 400 3 11.25 16 400 3 13.50 20 This fry station must be adequately and safely grounded. Refer to lo[...]