Go to page of
Similar user manuals
-
Water Pump
Ingersoll-Rand 66615X-X-C
8 pages 0.6 mb -
Water Pump
Ingersoll-Rand 650518
2 pages 0.1 mb -
Water Pump
Ingersoll-Rand 650542-X
4 pages 0.51 mb -
Water Pump
Ingersoll-Rand NP623XXXXR8-XX
4 pages 0.74 mb -
Water Pump
Ingersoll-Rand ARO 662605
4 pages 1.43 mb -
Water Pump
Ingersoll-Rand 613123-XXX-C
2 pages 0.18 mb -
Water Pump
Ingersoll-Rand NM2328A-X
2 pages 0.1 mb -
Water Pump
Ingersoll-Rand 662420-B
4 pages 0.24 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Ingersoll-Rand PE05X-XXX-XXX-B, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Ingersoll-Rand PE05X-XXX-XXX-B one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Ingersoll-Rand PE05X-XXX-XXX-B. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Ingersoll-Rand PE05X-XXX-XXX-B should contain:
- informations concerning technical data of Ingersoll-Rand PE05X-XXX-XXX-B
- name of the manufacturer and a year of construction of the Ingersoll-Rand PE05X-XXX-XXX-B item
- rules of operation, control and maintenance of the Ingersoll-Rand PE05X-XXX-XXX-B item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Ingersoll-Rand PE05X-XXX-XXX-B alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Ingersoll-Rand PE05X-XXX-XXX-B, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Ingersoll-Rand service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Ingersoll-Rand PE05X-XXX-XXX-B.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Ingersoll-Rand PE05X-XXX-XXX-B item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
CCN 15250384 OPERA T OR’S MANU AL PD05X -X XX - XX X-B PE05X -X XX -X XX -B INCL UDING: OPERA TION, INST ALLA TION & MAINTENANCE RELEASED: 8-27-08 REVISED: 5-28-10 (REV . 0 7 ) 1/2" DIAPHRA GM PUMP 1:1 RA TIO (MET ALLIC) READ THIS MANUAL CAREFULL Y BEFORE INST ALLING, OPERA TING OR SERVICING THIS EQUIPMENT . It is the responsibility of t[...]
-
Page 2
Page 2 of 12 PD05X- XXX -XXX -B (en) W ARNING EX CESSIVE AIR PRESSURE. Can cause personal injury , pump damage or property damage. Do not ex ceed the maximum inlet air pressure as sta ted on the pump model plate. Be sure material hoses and other componen ts are able to withstand uid pressures de veloped by this pump . Check all hoses for damage[...]
-
Page 3
PD05X- XXX -XXX -B (en) Page 3 of 12 y Hytrel® and V iton® are register ed trademarks of the DuPont Company y K ynar® is a registered trademark of Arkema Inc. y ARO® is a reg istered trademark of Ingersoll-Rand Company y y Santoprene® is a regist ered trademark of Monsanto Company , licensed to Advanced Elastomer S ystems, L.P . y Loctite® an[...]
-
Page 4
Page 4 of 12 PD05X- XXX -XXX -B (en) P ARTS LIST / P X05X- XXX -XXX -B FLUID SECTION n 637427-X X Fluid section service k it includes: Balls (see Ball Option, ref er to -X X in char t below), Diaphrag ms (see Diaphragm Option, refer t o -XX in chart below) and item 19 (listed below) plus it ems 144, 174 and 94276 Lubriplate FML -2 grease (pages 6 a[...]
-
Page 5
PD05X- XXX -XXX -B (en) Page 5 of 12 ) ASSEMBL Y TORQUE REQUIREMENTS ( NO TE: DO NOT OVERTIGHTEN F ASTENERS. (14) bolt, 95 - 105 in. lbs (10.7 - 11.9 Nm). (26) bolt and (29) nut, 50 - 60 in. lbs (5.6 - 6.8 Nm), alternately and ev enly , then re-torque after initial run-in. L UBRICA TION / SEAL ANT S c Apply Lubriplate FML -2 grease to all “ O” [...]
-
Page 6
Page 6 of 12 PD05X- XXX -XXX -B (en) n Indicates parts included in uid section ser vice kit, see page 4. MA TERIAL CODE [A] = Aluminum [D] = Acetal [B] = Nitrile [SS] = Stainless Steel [C] = Carbon Steel [U] = P olyurethane [Ck] = Ceramic [Z] = Zinc AIR MO T OR SEC TION SERVICE Service is divided into two parts - 1. Pilot V alve, 2. Major V alv[...]
-
Page 7
PD05X- XXX -XXX -B (en) Page 7 of 12 P ARTS LIST / P X05A-X XX -XX X-B AIR MO T OR SEC TION ) ASSEMBL Y TORQUE REQUIREMENTS ( NO TE: DO NOT OVERTIGHTEN F ASTENERS. (123) screw , 10 - 12 in. lbs (1.13 - 1.36 Nm). (134) bolt, torque to 15 - 20 in. lbs (1.7 - 2.3 Nm), wait 10 minutes , then re-torque to 15 - 20 in. lbs (1.7 - 2.3 Nm). L UBRICA TION / [...]
-
Page 8
Page 8 of 12 PD05X- XXX -XXX -B (en) n Indicates par ts included in uid section ser vice kit, see page 4. MA TERIAL CODE [B] = Nitrile [PPG] = Glass lled Polypr opylene [C] = Carbon Steel [SS] = Stainless Steel [Ck] = Ceramic [Sy] = Syn-Seal [D] = Acetal [U] = P olyurethane AIR MO T OR SEC TION SERVICE Service is divided into two parts - 1.[...]
-
Page 9
PD05X- XXX -XXX -B (en) Page 9 of 12 P ARTS LIST / P X05R-XX X- XX X-B AIR MO TOR SECTION Figur e 4 ) ASSEMBL Y TORQUE REQUIREMENTS ( NO TE: DO NOT OVERTIGHTEN F ASTENERS. (123) screw , 4 - 6 in. lbs (0.45 - 0.68 Nm). (134) bolt, torque to 15 - 20 in. lbs (1.7 - 2.3 Nm), wait 10 minutes , then re-torque to 15 - 20 in. lbs (1.7 - 2.3 Nm). L UBRICA T[...]
-
Page 10
Page 10 of 12 PD05X- XXX -XXX -B (en) TYPICAL CROSS SECTION Figur e 5 Models PE05R-XXS-XXX-B Models PE05A- XXS-XX X-B[...]
-
Page 11
PD05X- XXX -XXX -B (en) Page 11 of 12 TROUBLE SHOO TING Product discharged from e xhaust outlet. Check for diaphragm ruptur e. Check tightness of (14) bolt. Air bubbles in product discharge. Check connections of suction plumbing. Check “O” rings bet w een intake manifold and uid caps. Check tightness of (14) bolt. Motor blows air out main e[...]
-
Page 12
Page 12 of 12 PD05X- XXX -XXX -B (en) PN 97999-1167 DIMENSIONAL DA T A / P X05R-XXS- XXX -B DIMENSIONS A - 7-11/16” (195.2 mm) B - 11-1/16” (280.4 mm) C - 6-1/8” (155.6 mm) D - 2” (50.8 mm) E - 6-23/32” (170.6 mm) F - 6” (152.4 mm) G - 11-21/32” (296.0 mm) H - 4-7/8” (123.8 mm) J - 5-1/2” (139.7 mm) K - 5/16” (7.9 mm) L - 1-1/4?[...]