Go to page of
Similar user manuals
-
Switch
Omega Vehicle Security FSW-420
3 pages 0.34 mb -
Network Card
Omega Vehicle Security zSeries
72 pages 4.71 mb -
Thermometer
Omega Vehicle Security OS642F
16 pages 0.2 mb -
Switch
Omega Vehicle Security LV-1201
8 pages 0.34 mb -
Camcorder
Omega Vehicle Security HHB400
24 pages 1.11 mb -
Battery Charger
Omega Vehicle Security SMCJ-J
2 pages 0.15 mb -
Computer Monitor
Omega Vehicle Security CNiTH-16D-AL
2 pages 0.42 mb -
Electric Heater
Omega Vehicle Security KHLV Series
4 pages 0.23 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Omega Vehicle Security DP63000A-I, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Omega Vehicle Security DP63000A-I one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Omega Vehicle Security DP63000A-I. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Omega Vehicle Security DP63000A-I should contain:
- informations concerning technical data of Omega Vehicle Security DP63000A-I
- name of the manufacturer and a year of construction of the Omega Vehicle Security DP63000A-I item
- rules of operation, control and maintenance of the Omega Vehicle Security DP63000A-I item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Omega Vehicle Security DP63000A-I alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Omega Vehicle Security DP63000A-I, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Omega Vehicle Security service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Omega Vehicle Security DP63000A-I.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Omega Vehicle Security DP63000A-I item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
LP0694A omega.com e-mail: info@omega.com For latest product manuals: omegamanual.info U ser ’ s Guide Shop online at D D P P 6 6 3 3 0 0 0 0 0 0 A A -I I D D P P 6 6 3 3 0 0 0 0 0 0 B B -I I Digita l P P anel M M eter[...]
-
Page 2
OMEGAnet ® Online Ser vice omega.com Inter net e-mail info@omega.com Ser vicing North America: U.S.A.: One Omega Drive, P .O . Bo x 4047 ISO 9001 Certified Stamford, CT 06907-0047 TEL: (203) 359-1660 F AX: (203) 359-7700 e-mail: info@omega.com Canada: 976 Bergar Laval (Quebec) H7L 5A1, Canada TEL: (514) 856-6928 F AX: (514) 856-6886 e-mail: info@o[...]
-
Page 3
3 z FOUR SELECT ABLE D.C. RANGES 200 µ A, 2 mA, 20 mA, 200 mA z MINIMUM AND MAXIMUM DISPLA Y CAPTURE z LCD, REFLECTIVE OR RED/GREEN LED BACKLIGHTING z 0.48" (12.2 mm) HIGH DIGITS z OPTIONAL SETPOINT OUTPUT MODULES z OPTIONAL SERIAL COMMUNICA TIONS MODULES (RS232 or RS485) z OPERA TES FROM 9 TO 28 VDC POWER SOURCE z FRONT P ANEL OR SOFTWARE PR[...]
-
Page 4
1. DISPLA Y : 5 digit LCD 0.48" (12.2 mm) high digits DP63000A-I : Reflective LCD with full viewing angle DP63000B-I : T ransmissive LCD with selectable red or green LED backlight, viewing angle optimized. Display color change capability with output state when using an output module. 2. POWER : Input voltage range is +9 to +28 VDC with short c[...]
-
Page 5
5 ADDING OPTION CARDS The DP63000 meters can be fitted with optional output cards and/or serial communications cards. The details for the plug-in cards can be reviewed in the specification section below . The plug-in cards, that are sold separately , can be installed initially or at a later date. W ARNING: Disconnect all power to the unit before in[...]
-
Page 6
WIRING OVERVIEW Electrical connections are made via screw-clamp terminals located on the back of the meter . All conductors should conform to the meter ’ s voltage and current ratings. All cabling should conform to appropriate standards of good installation, local codes and regulations. It is recommended that the power supplied to the meter (DC o[...]
-
Page 7
7 4.3 INPUT WIRING CAUTION : Power input common is NOT isolated from user input common. In order to preserve the safety of the meter application, the power input common must be suitably isolated from hazardous live earth referenced voltage; or input common must be at protective earth ground potential. If not, hazardous voltage may be present at the[...]
-
Page 8
8 5.0 R EVIEWING THE F RONT B UTTONS AND D ISPLAY PROGRAMMING MODE ENTR Y (SEL BUTT ON) It is recommended all programming changes be made off line, or before installation. The meter normally operates in the Display Mode. No parameters can be programmed in this mode. The Programming Mode is entered by pressing and holding the SEL button. If it is no[...]
-
Page 9
9 6.1 MODULE 1 - S IGNAL I NPUT P ARAMETERS ( 1-INP ) P ARAMETER MENU ª « 0.02A rAN6E INPUT RANGE Select the input range that corresponds to the external signal. This selection should be high enough to avoid input signal overload but low enough for the desired input resolution. This selection and the position of the Input Range Jumper must match.[...]
-
Page 10
Entering Code 66 will overwrite all user settings with the factory settings. The meter will display rESEt and then return to CodE 00 . Press the SEL button to exit the module. 10 6.2 MODULE 2 - S ECONDARY F UNCTION P ARAMETERS ( 2-SEC ) P ARAMETER MENU MIN DISPLA Y ENABLE USER INPUT ASSIGNMENT Select the value(s) to which the User Input Function is[...]
-
Page 11
11 The Security Code determines the programming mode and the accessibility of programming parameters. This code can be used along with the Program Mode Lock-out ( P-Loc ) in the User Input Function parameter (Module 1). T wo programming modes are available. Full Programming mode allows all parameters to be viewed and modified. Quick Programming mod[...]
-
Page 12
Enter the reset action of the output. See figure for details. Auto = Automatic action; This action allows the output to automatically reset off at the trigger points per the Setpoint Action shown in Setpoint Output Figures. The “on” output may be manually reset (of f) immediately by the front panel RST button or user input.The output remains of[...]
-
Page 13
13 6.5 MODULE 5 - S ERIAL S ETUP P ARAMETERS ( 5 -S S E r ) The Serial Setup Parameters are only active when the optional RS232 or RS485 serial communications module is installed in the meter . Refer to the DP6-COM bulletin for complete details on DP63000 serial communications. P ARAMETER MENU button or user input manual reset, serial reset command[...]
-
Page 14
PROGRAMMING QUICK OVERVIEW Press and hold SEL button to enter Programming Mode.[...]
-
Page 15
W ARRANTY/DISCLAIMER OMEGA ENGINEERING , INC. warrants this unit to be free of defects in materials and workmanship for a period of 13 months from date of purchase. OMEGA ’s WARRANTY adds an additional one (1) month grace period to the normal one (1) year product warranty to cover handling and shipping time. This ensures that OMEGA ’s customers[...]
-
Page 16
Where Do I F ind Everything I Need for P rocess Measurement and Control? OMEGA…Of Course! Shop online at omega.com TEMPERA TURE ] Thermocouple, RTD & Thermistor Probes, Connectors, P anels & Assemblies ] W ire: Thermocouple, RTD & Thermistor ] Calibrators & Ice P oint References ] Recorders, Controllers & Process Monitors ] In[...]