A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Raypak B-195, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Raypak B-195 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Raypak B-195. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Raypak B-195 should contain:
- informations concerning technical data of Raypak B-195
- name of the manufacturer and a year of construction of the Raypak B-195 item
- rules of operation, control and maintenance of the Raypak B-195 item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Raypak B-195 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Raypak B-195, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Raypak service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Raypak B-195.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Raypak B-195 item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
CATALOG NO.: 3300.51 I Effective: 01-01-03 Replaces: 01-01-01 Model B-195 FOR YOUR SAFETY WHAT TO DO IF YOU SMELL GAS *Do not try to light any appliance. *Do not touch any electrical switch; do not use any phone in your building. *Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions. *If you c[...]
-
Page 2
CONTENTS PAGE DESCRIPTION 3 1. RECEIVING EQUIPMENT 3 2. GENERAL SPECIFICATIONS AND DIMENSIONS 4 3. INSTALLATION PROCEDURES 4 - Code Requirements 4 - Combustion/Ventilation Air 5 - Venting 8 - Gas Piping 8 - Water Piping 11 - Electrical Wiring 12 4. START-UP AND OPERATION 12 - Component Location 12 - Sequence of Operation 12 - START-UP Procedures. 1[...]
-
Page 3
3 1. RECEIVING EQUIPMENT On receipt of your equipment it is suggested that you visually check for external damage to the carton. If the carton is damaged, it is suggested that a note be made on the Bill of Lading when signing for equipment. Remove the heater from the carton and if it is damaged report the damage to the carrier immediately. Be sure [...]
-
Page 4
3. INSTALLATION PROCEDURES. CODE REQUIREMENTS Installation must be in accordance with local codes, or in the absence of local codes with the latest edition of the National Fuel Gas Code, ANSI Z223.1, the National Electrical Code, ANSI/NFPA 70. For Canada, CAN/ CGA B149.1 and .2, and CSA C22.2 No. 1. LEG INSTALLATION Four (4) legs are supplied loose[...]
-
Page 5
Measures must be taken to prevent the entry of corrosive chemical fumes to the combustion and ventilation air supply. Such chemicals include, but are not limited to, chlorinated and/or fluorinated hydrocarbons such as found in refrigerants, aerosol propellants, dry-cleaning fluids, degreasers, and paint removers. Other harmful elements may come fro[...]
-
Page 6
6 Fig. #8975.3 Applies only to exhaust hood over cooking equipment.[...]
-
Page 7
All horizontal runs of the vent pipe shall have a minimum rise of 1/4" per foot of length and should be supported at maximum intervals of 5 feet (for Canada, 3 feet) and at each point where an elbow is used. For horizontal venting, the total length of 4-inch diameter pipe shall not exceed 30 feet with up to two 90° elbows and 1 termination ve[...]
-
Page 8
GAS PIPING The gas inlet pipe size is 1/2" NPT to the gas valve. Provide an adequate size gas supply line. The line should not be smaller than 1/2" NPT according to the chart below. MAXIMUM EQUIVALENT PIPE LENGTH (FEET) Pipe Size Gas 1/2" 3/4" 1" Natural 5 30 100 Propane 70 180 Gas piping must have a sediment trap ahead of [...]
-
Page 9
9 A drain valve is provided in the tank for draining water during servicing. The temperature and pressure relief valve is easily accessible through the front. A nipple is provided (shipped loose with the heater) for installation in the T & P relief valve. A drain line must be connected to the nipple and run to a safe place of disposal. WARNING:[...]
-
Page 10
ELECTRICAL The electrical power supply requirement for the heater is 120 volts, 60 Hz, 5.0 amps or less . Field wiring connections and electrical grounding must comply with the local codes, or in the absence of local codes, with the latest edition of the National Electrical Code, ANSI/NFPA 70. NOTE: Polarity must be observed for the heater to opera[...]
-
Page 11
11 LADDER DIAGRAM CONNECTION DIAGRAM DANGER: SHOCK HAZARD Turn off electrical power to boost heater before servicing any component in the heater to prevent equipment damage or personal injury. NOTE: If it is necessary to replace any of the original wiring, it must be replaced with 105°C rated wire or its equivalent.[...]
-
Page 12
SEQUENCE OF OPERATION The booster heater is designed to maintain a tempera- ture of 180 deg. F (82.2 Deg. C) of 490 GPH water required for the rinse cycle of a commercial dish- washer. An inlet temperature of 140 Deg. F (60 Deg. C) will produce optimum results. Provided the necessary power, water, gas and vent connections are completed, the unit is[...]
-
Page 13
SECTION 3. LIGHTING THE HEATER Safety lighting and other performance criteria were met for the burner assembly and control assembly when the heater was tested for design certification under the ANSI Z21.10.3 Standard WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or [...]
-
Page 14
SECTION 4. TESTING THE IGNITION SAFETY SHUT-OFF The ignition system safety shut-off must be tested by conducting the following method of tests: a) With the system power off, manually shut off the gas supply. b) Turn power back on, observe the igniter start to heat up and glow bright orange. c) After about four (4) seconds, the gas valve is energize[...]
-
Page 15
5. Limit Control Module a) Shut-off electrical power to the heater. b) Remove control cover screws and open con- trol compartment. c) Disconnect wiring connections to the board. d) Carefully pull out the control board from the nylon pin supports. e) Reverse above procedure to reinstall. 6. Sensor Probe Replacement a) Shut off electrical power to th[...]
-
Page 16
5. SERVICING UNIT TROUBLE SHOOTING GUIDE PROBLEM 1. On-Off switch energized. Unit does not operate. 2. Pump/Blower NOT running. 3. Unit energized, pump and blower running, but burner is NOT on. POSSIBLE CAUSE 1a. No power to heater 1b. Defective transformer 2a. Loose wire(s) 2b. Defective pump 2c. Defective blower. 3a . Limit control (operating lim[...]
-
Page 17
Continuation TROUBLE SHOOTING GUIDE 3d. Excessive negative pressure exerted by the exhaust system on the vent will prevent N.O. combustion air/vent switch from closing. Provide means to relieve pressure and close the N.O. switch. If combustion air/vent switch will not close, replace switch. 3e. Disconnect igniter leads from ignition module. Make su[...]
-
Page 18
18 6. REPLACEMENT PARTS LIST NOTE: To supply the correct part it is important that you state the model number, serial number and type of gas when applicable. Any part returned for replacement under standard company warranties must be properly tagged with RAYPAK return parts tag, completely filled in with the heater Serial Number, Model Number etc.,[...]
-
Page 19
19[...]
-
Page 20
20[...]
-
Page 21
21[...]
-
Page 22
LIMITED PARTS WARRANTY COMMERCIAL BOOSTER HEATER SCOPE: Raypak, Inc. ("Raypak") warrants to the owner that all parts of this booster heater, excluding controls and pump, will be free from failure under normal use and service for the specified warranty periods and subject to the conditions set forth in this Warranty. The Warranty is effect[...]
-
Page 23
Raypak, Inc. , 2151 Eastman Avenue, Westlake Village, CA 93030 (805) 278-5300 FAX (800) 872-9725 Raypak Canada Limited , 2805 Slough St., Mississauga, Ontario, Canada L4T 1G2 (416) 677-7999 FAX (416) 677-8036 Litho in U.S.A. www .raypak.com[...]