Go to page of
Similar user manuals
-
Carbon Monoxide Alarm
Sierra Monitor Corporation 4001
2 pages 0.07 mb -
Server
Sierra Monitor Corporation Sentry Webserver
2 pages 0.15 mb -
Carbon Monoxide Alarm
Sierra Monitor Corporation 2001
2 pages 0.11 mb -
Carbon Monoxide Alarm
Sierra Monitor Corporation TR-005
2 pages 0.1 mb -
Carbon Monoxide Alarm
Sierra Monitor Corporation Sentry Controller Gas Detector
19 pages 0.07 mb -
Carbon Monoxide Alarm
Sierra Monitor Corporation 4100 Series
2 pages 0.25 mb -
Carbon Monoxide Alarm
Sierra Monitor Corporation 55
20 pages 0.16 mb -
Carbon Monoxide Alarm
Sierra Monitor Corporation Sentry 5100 Series
2 pages 0.1 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Sierra Monitor Corporation HRG010-W, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Sierra Monitor Corporation HRG010-W one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Sierra Monitor Corporation HRG010-W. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Sierra Monitor Corporation HRG010-W should contain:
- informations concerning technical data of Sierra Monitor Corporation HRG010-W
- name of the manufacturer and a year of construction of the Sierra Monitor Corporation HRG010-W item
- rules of operation, control and maintenance of the Sierra Monitor Corporation HRG010-W item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Sierra Monitor Corporation HRG010-W alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Sierra Monitor Corporation HRG010-W, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Sierra Monitor Corporation service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Sierra Monitor Corporation HRG010-W.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Sierra Monitor Corporation HRG010-W item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
HRX-OM-J049-A 1st edition: Aug. 2006 Rev . A: May . 2007 Operation Manual W ater-refrigerated T hermo cooler HRG010-W HRG015-W SMC Cor poration Save This Manual Carefully for Use at Any T i me © 2006 SMC CORPORA T ION All Rights Reserved[...]
-
Page 2
T o the Custom ers Thank you for purch asing o ur T HERMO COOLER HRG Ser ies (her einafter c alled “T his unit”) . For saf ety and eff icienc y, be sure to r ead and underst and this m anual thoroughl y befor e perform ing operatio n of this unit. z All warn ings an d preca utions def ined in t his m anual s hall be obs erved. z This manual pr [...]
-
Page 3
HRX-OM-J049-A T able of Content s HRG010-W HRG015-W 1st edition : Aug. 2006 Rev. A: May. 2007 TOC- 1 T able of Content s Chapter 1 Safety Instru ctio ns ........................................................... 1-1 1.1 Befo re Using this Unit ............................................................................................. 1-1 1.2 Dan[...]
-
Page 4
HRX-OM -J049-A T able of Content s HRG010-W HRG015-W 1st edition : Aug. 2006 Rev. A: May. 2007 TOC- 2 3.2.7 Suppl y of circulatin g fluid ................................................................................................... 3 -1 5 3.2.8 Reinstallati on of unit ...........................................................................[...]
-
Page 5
HRX-OM-J049-A T able of Content s HRG010-W HRG015-W 1st edition : Aug. 2006 Rev. A: May. 2007 TOC- 3 7.4.2 HRG010-W -BC, HRG015- W-BC ......................................................................................... 7-6 7.5 Flo w Char t..........................................................................................................[...]
-
Page 6
HRX-OM -J049-A T able of Content s HRG010-W HRG015-W 1st edition : Aug. 2006 Rev. A: May. 2007 TOC- 4[...]
-
Page 7
HRX-OM-J049-A Chapter 1 Saf et y Instructions HRG010-W HRG015-W 1.1 Before Using t his Unit 1st edition : Aug. 2006 Rev. A: May. 2007 1-1 Chapter 1 Safety Instructions 1.1 Before Using this Unit z T his chapter des cribes the safety-related items that users should be aw are of upon handling this unit. z T his uni t is a n isothe rmal flui d c ircul[...]
-
Page 8
HRX-OM -J049-A Chapter 1 Saf et y Instructions 1.2 Danger, Warning and Caution HRG010-W HRG015-W 1st edition : Aug. 2006 Rev. A: May. 2007 1-2 1.2 Danger, Wa rning and Cautio n 1.2.1 Level of risk This unit is design ed with the safety of workers and the preven tion o f system damage. This manual classifies the risks i nto the following three categ[...]
-
Page 9
HRX-OM-J049-A Chapter 1 Saf et y Instructions HRG010-W HRG015-W 1.2 Danger, Warning and Caution 1st edition : Aug. 2006 Rev. A: May. 2007 1-3 1.2.3 S y mbols This manual provides the follo wing symbols in addition to “Danger”, “W arning”, and “Caution” to pres ent the warning details in easy-to-understan d manner . Symbol of electri[...]
-
Page 10
HRX-OM -J049-A Chapter 1 Saf et y Instructions 1.3 Hazard Warning Label HRG010-W HRG015-W 1st edition : Aug. 2006 Rev. A: May. 2007 1-4 1.3 Hazard Warning La bel The hazard w arning labels indicate where potential hazards are pres ent during un it operation and m aintenance. The hazard w ar ning labels are in appropriate s izes and color s. They co[...]
-
Page 11
HRX-OM-J049-A Chapter 1 Saf et y Instructions HRG010-W HRG015-W 1.3 Hazard Warning Label 1st edition : Aug. 2006 Rev. A: May. 2007 1-5 1.3.2 Type of hazard w arning labels Warning label on the front panel Fig. 1-1 Warning Label on the Front Pane l Warning label for high voltage Fig. 1-2 Warning Label for High V oltage Read the contents of t[...]
-
Page 12
HRX-OM -J049-A Chapter 1 Saf et y Instructions 1.4 Model label HRG010-W HRG015-W 1st edition : Aug. 2006 Rev. A: May. 2007 1-6 1.3.3 Location of hazard warning l abel Fig. 1-3 Locat ion of Hazard Warning Label 1.4 Model label Check the m odel no. described on th e label. Fig. 1-4 Locat ion of M odel Label Front War ning label for high Left Wa rning[...]
-
Page 13
HRX-OM-J049-A Chapter 1 Saf et y Instructions HRG010-W HRG015-W 1.5 Safety Measures 1st edition : Aug. 2006 Rev. A: May. 2007 1-7 1.5 Safety Measu res 1.5.1 Safety Precautions While this system is protected by various safety measures, the following basic s afety precautions should be observed to as sure furth er safe operations. z Read and understa[...]
-
Page 14
HRX-OM -J049-A Chapter 1 Saf et y Instructions 1.5 Safety Measures HRG010-W HRG015-W 1st edition : Aug. 2006 Rev. A: May. 2007 1-8 1.5.2 Protect ive equipment This manual defin e s protective eq uipment accordin g to work type. Wear proper protectiv e equipment as shown below, according to work type. For system transportation, instal lation and[...]
-
Page 15
HRX-OM-J049-A Chapter 1 Saf et y Instructions HRG010-W HRG015-W 1.6 Emergency Measures 1st edition : Aug. 2006 Rev. A: May. 2007 1-9 1.6 Emergen cy Measur es Press the [OFF] switch on the control panel located on th e front of the therm o cooler only if the n eed to shut off the power aris es due to emergency such a s natural disast er, fire, earth[...]
-
Page 16
HRX-OM -J049-A Chapter 1 Saf et y Instructions 1.7 Dispositi on of Waste HRG010-W HRG015-W 1st edition : Aug. 2006 Rev. A: May. 2007 1-10 1.7 Disposition o f Waste 1.7.1 Recovery of refrig erant and compressor oil The unit belongs t o Class 1 in the “Fluorocarbon Recovery and Dest ruction Law” and uses f r eon type ref rigerant (HFC) and compre[...]
-
Page 17
HRX-OM-J049-A Chapter 1 Saf et y Instructions HRG010-W HRG015-W 1.8 Material Safety Data Sheet (MSDS) 1st edition : Aug. 2006 Rev. A: May. 2007 1-11 1.7.2 Circul ating flui d disposal As to the disp osal of a ci rcul ati ng flui d (e thyle ne gl ycol so lu tion) , co nsign t he specialized industrial wast e disposal agency with the con tents detail[...]
-
Page 18
HRX-OM -J049-A Chapter 1 Saf et y Instructions 1.8 M aterial Safety Dat a Sheet (MSDS) HRG010-W HRG015-W 1st edition : Aug. 2006 Rev. A: May. 2007 1-12[...]
-
Page 19
HRX-OM-J049-A Chapter 2 A ppearance and Each Secti on HRG010-W HRG015-W 2.1 Appearance 1st edition : Aug. 2006 Rev. A: May. 2007 2-1 Chapter 2 Appearance and Each Section 2.1 A ppearance Fig. 2-1 Appearance of HRG010-W Fig. 2-2 Appearance of HRG015-W Front Right Back T op Left Front Right Back T op Left[...]
-
Page 20
HRX-OM -J049-A Chapter 2 A ppearance and Each Secti on 2.2 Name of Each Section HRG010-W HRG015-W 1st edition : Aug. 2006 Rev. A: May. 2007 2-2 2.2 Name of Each Section 2.2.1 HRG010-W Fig. 2-3 Name of E ach Secti on (HRG010-W) T op Front Left Right 4-Ø13 (For anchor bolt) T ank drain port Rc1/2 (plugged) V enti lating hole Port fo r overflow Rc 1/[...]
-
Page 21
HRX-OM-J049-A Chapter 2 A ppearance and Each Secti on HRG010-W HRG015-W 2.2 Name of Each Section 1st edition : Aug. 2006 Rev. A: May. 2007 2-3 2.2.2 HRG015-W Fig. 2-4 Name of E ach Secti on (HRG015-W) Y -s haped strainer Rc1/2 (accessory) T op Front Left Right 4-Ø13 (For anchor bolt) T ank drain port Rc1/2 (plugged) V enti lating hole Port fo r ov[...]
-
Page 22
HRX-OM -J049-A Chapter 2 A ppearance and Each Secti on 2.3 Control panel HRG010-W HRG015-W 1st edition : Aug. 2006 Rev. A: May. 2007 2-4 2.3 Control panel The control panel on the system front allo ws you to perform basic system operation including temperature adjsutmen t, system start and stop. Fig. 2-5 Control Pa nel T able 2-1 C ontrol Pan el No[...]
-
Page 23
HRX-OM-J049-A Chapter 3 T ransport and Inst allation HRG010-W HRG015-W 3.1 Transport 1st edition : Aug. 2006 Rev. A: May. 2007 3-1 Chapter 3 Transport and Installation 3.1 Transp ort The unit is heavy and poses po tential danger at transportation. T o prevent damage to the unit, be sure to follow the instructions belo w when transporting the unit. [...]
-
Page 24
HRX-OM -J049-A Chapter 3 T ransport and Inst allation 3.1 Transport HRG010-W HRG015-W 1st edition : Aug. 2006 Rev. A: May. 2007 3-2 3.1.1 Transporti ng w ith forklift and unit li fting Fig. 3-2 Forklif t Insertion Pos ition and Unit Lif ting Min. 60° Forklift ins ertion side Forklift ins ertion side Front Lifti ng positio n Min. 60°[...]
-
Page 25
HRX-OM-J049-A Chapter 3 T ransport and Inst allation HRG010-W HRG015-W 3.1 Transport 1st edition : Aug. 2006 Rev. A: May. 2007 3-3 3.1.2 Transporti ng with caster HRG010-W-A / HRG0 15-W-A ( caster-mounted option) 1. Push th e corn ers o f this unit wi th the adju sters upli fted. The unit becomes diseng a ged so that it can be trans ported with[...]
-
Page 26
HRX-OM -J049-A Chapter 3 T ransport and Inst allation 3.2 Installat ion HRG010-W HRG015-W 1st edition : Aug. 2006 Rev. A: May. 2007 3-4 3.2 Installation 3.2.1 Installa tion conditions Do not use or store the unit in the follo wing environments. Potential unit mal function and damage may occur if disregarded. z Environment that is e xposed to water [...]
-
Page 27
HRX-OM-J049-A Chapter 3 T ransport and Inst allation HRG010-W HRG015-W 3.2 Installat ion 1st edition : Aug. 2006 Rev. A: May. 2007 3-5 3.2.2 Installat i on location Required water sources T able 3-1 Heat Di scharge and Requir ed Quantity of Facil ity Water (H RG010- W, HR G015-W) Model Heat discharge (kW) Facility water temp. range (°C) Requ i[...]
-
Page 28
HRX-OM -J049-A Chapter 3 T ransport and Inst allation 3.2 Installat ion HRG010-W HRG015-W 1st edition : Aug. 2006 Rev. A: May. 2007 3-6 3.2.3 Installation location and maintenan ce work area Installation with mainten a nce space is recommended. (See Fig. 3- 4) Fig. 3-4 Recommen ded Insta llation Location Ensure an adequate ventilation space for the[...]
-
Page 29
HRX-OM-J049-A Chapter 3 T ransport and Inst allation HRG010-W HRG015-W 3.2 Installat ion 1st edition : Aug. 2006 Rev. A: May. 2007 3-7 3.2.4 Installat i on z Keep the unit away from vibration. Install the unit on a flat an d stable surface. z Refer to “7.3 Outline Dimensions” for the dimensions of the unit. Procedure for Installation 1. The[...]
-
Page 30
HRX-OM -J049-A Chapter 3 T ransport and Inst allation 3.2 Installat ion HRG010-W HRG015-W 1st edition : Aug. 2006 Rev. A: May. 2007 3-8 HRG010-W-A / HRG0 15-W-A ( caster-mounted option) Fig. 3-6 HRG010- W-A / HRG015- W-A (Caster-mount ed Option) Caster w/ adj uster Lower the ad justers to secure the system . A s to t he HRG010-W-A or HRG015-W- [...]
-
Page 31
HRX-OM-J049-A Chapter 3 T ransport and Inst allation HRG010-W HRG015-W 3.2 Installat ion 1st edition : Aug. 2006 Rev. A: May. 2007 3-9 3.2.5 Electri cal wiri ng Power supply cable and GFCI breaker Select a cable for pow er s upply and GFCI break er corresponding to the model n o. provided in the following table. T able 3-2 Cable for P ower Supp[...]
-
Page 32
HRX-OM -J049-A Chapter 3 T ransport and Inst allation 3.2 Installat ion HRG010-W HRG015-W 1st edition : Aug. 2006 Rev. A: May. 2007 3-10 How to conduct wiring 1. Undo the screws (6 pcs .) and take off the front pa nel. 2. Connect the power supply cable and sig nal cable as show n in the figure. Fig. 3-7 Removal of Front Panel Fig. 3-8 Electrica[...]
-
Page 33
HRX-OM-J049-A Chapter 3 T ransport and Inst allation HRG010-W HRG015-W 3.2 Installat ion 1st edition : Aug. 2006 Rev. A: May. 2007 3-11 Electrical wiring diagram • HRG010-W z Fig. 3-9 Electrical Wiring Di agram (HRG 010- W ) • HRG015-W Fig. 3-10 Electrica l W iring Diagram (HRG015- W ) z Prepare cables for the po w er suppl y and signal lin[...]
-
Page 34
HRX-OM -J049-A Chapter 3 T ransport and Inst allation 3.2 Installat ion HRG010-W HRG015-W 1st edition : Aug. 2006 Rev. A: May. 2007 3-12 Procedures for communication cable w iring installation (RS48 5) HRG010-W-C / HRG015-W- C (communicati on feature-laden option) The communication cables are to adh ere to specifications sho wn below. T able 3-[...]
-
Page 35
HRX-OM-J049-A Chapter 3 T ransport and Inst allation HRG010-W HRG015-W 3.2 Installat ion 1st edition : Aug. 2006 Rev. A: May. 2007 3-13 Pipe coupling hole Sealant Fig. 3-12 T ightening of P i pe 3.2.6 Piping Pipe diameter T able 3-5 P ipe dia meter Diameter Pipe HRG010-W HRG015-W Recommended tightening torque Facilit y water IN Rc1/2 Rc3/4 28 t[...]
-
Page 36
HRX-OM -J049-A Chapter 3 T ransport and Inst allation 3.2 Installat ion HRG010-W HRG015-W 1st edition : Aug. 2006 Rev. A: May. 2007 3-14 Recommended piping installation T able 3-6 Reco mmended Pi ping Inst allation Size No. Name HRG010-W HRG015-W 1 V alve Rc1/2 Rc3/4 2 Y - shaped stra iner Rc1/2 Rc3/4 3 Pressure gauge 0 to 1.0 MP a 4 V alve Rc3[...]
-
Page 37
HRX-OM-J049-A Chapter 3 T ransport and Inst allation HRG010-W HRG015-W 3.2 Installat ion 1st edition : Aug. 2006 Rev. A: May. 2007 3-15 3.2.7 Suppl y of circulating flui d 1. Open the supply v alve laid with pipes. The fluid supply ta kes place with the use of th e ball tap ho used in the tank and stops automatically. Fig. 3-14 Lev el Gauge Level g[...]
-
Page 38
HRX-OM -J049-A Chapter 3 T ransport and Inst allation 3.2 Installat ion HRG010-W HRG015-W 1st edition : Aug. 2006 Rev. A: May. 2007 3-16 3.2.8 Reinstallation of un it When the unit is tran sferred to and reinst alled in a different place after operation at the original place (including tr ial run), perform transporting and in stallation of the unit[...]
-
Page 39
HRX-OM-J049-A Chapter 4 St artup and Shutdo w n HRG010-W HRG015-W 4.1 Pre-check 1st edition : Aug. 2006 Rev. A: May. 2007 4-1 Chapter 4 Startup and Shutdown 4.1 Pre-che ck Chec k the fo llo wing i tems b efo re sta rting up the unit. 4.1.1 Installa tion condition z M ake s ure the unit is insta lle d hor izont ally. z Do not put any h eavy object o[...]
-
Page 40
HRX-OM -J049-A Chapter 4 St artup and Shutdo w n 4.2 Preparati on for startup HRG010-W HRG015-W 1st edition : Aug. 2006 Rev. A: May. 2007 4-2 4.2 Prepar ation for startup 4.2.1 Power suppl y 1. Supply the power. The follow i ng condit ions are observ ed on th e control pan el upon pow er -ON. z After 4-sec display of the initial screen on the digit[...]
-
Page 41
HRX-OM-J049-A Chapter 4 St artup and Shutdo w n HRG010-W HRG015-W 4.2 Preparati on for startup 1st edition : Aug. 2006 Rev. A: May. 2007 4-3 4.2.3 Additional w ater suppl y [TS] switch (pump manual operation switch) This unit has the [TS] switch (pump manual operatio n switch) to purge air from the circulating fluid circu it at initial startup.[...]
-
Page 42
HRX-OM -J049-A Chapter 4 St artup and Shutdo w n 4.3 Unit Startup and Shutdown HRG010-W HRG015-W 1st edition : Aug. 2006 Rev. A: May. 2007 4-4 4.3 Unit Startup a nd Shutdo w n 4.3.1 Starting the unit 1. Press the [ON] switch on the control panel. The unit starts operatin g and regulates the circu lating fluid temperature. The [RUN] LED and [PUMP] L[...]
-
Page 43
HRX-OM-J049-A Chapter 4 St artup and Shutdo w n HRG010-W HRG015-W 4.4 Check at start up 1st edition : Aug. 2006 Rev. A: May. 2007 4-5 4.4 Check at st artu p Check the following items at startup of th e unit. z N o lea k fro m circ ulat ing fl uid pi ping z No circulating flui d flowing o ut of the ov erflo w o utlet and t ank drai n port z Circulat[...]
-
Page 44
HRX-OM -J049-A Chapter 4 St artup and Shutdo w n 4.4 Check at start up HRG010-W HRG015-W 1st edition : Aug. 2006 Rev. A: May. 2007 4-6 Bypass ( relieving v alve) piping set [Tip s] Bypass (reliev ing val ve) piping s ets lis ted in t able 3-7 “Allie d Products ” are of use for the omis sion of m anual b ypass valve adjustm ent. [Tip s] The [...]
-
Page 45
HRX-OM-J049-A Chapter 5 Error Mess age and T roubles hooting HRG010-W HRG015-W 5.1 Error Message 1st edition : Aug. 2006 Rev. A: May. 2007 5-1 or or or or [PO W ER] LED [ALARM 1] LED [PO W ER] LED [ALARM 2] LED [ALARM 3] LED Chapter 5 Error Message and Troubleshooting 5.1 Error Mes sage This product s tops when an error is detected. Table 5-1 shows[...]
-
Page 46
HRX-OM -J049-A Chapter 5 Error Mess age and T roubles hooting 5.2 Troubleshooting HRG010-W HRG015-W 1st edition : Aug. 2006 Rev. A: May. 2007 5-2 5.2 Troubles hooting See “5.3 Alarm Reset” for err or recovery. T able 5-2 T roubleshooting Alarm r eset Error Cause Remedies Detector HRG No power is supplied. W . it h the sw itch in its O N posit[...]
-
Page 47
HRX-OM-J049-A Chapter 5 Error Mess age and T roubles hooting HRG010-W HRG015-W 5.3 Alarm Reset (Alarm Lamp OFF) 1st edition : Aug. 2006 Rev. A: May. 2007 5-3 5.3 Alarm Reset (Alarm Lamp OFF) Error check 1. Check the alarm number currently activated, and eliminate the error cause (see Table 5-2). Adjust the unit usage and service condition. Fig.[...]
-
Page 48
HRX-OM -J049-A Chapter 5 Error Mess age and T roubles hooting 5.3 Alarm Reset (Alarm Lamp OFF) HRG010-W HRG015-W 1st edition : Aug. 2006 Rev. A: May. 2007 5-4 2. Undo the screws (6 pcs .) to remove the f ront panel. Fig. 5-3 Removal of Front Panel Front pane l Screw Screw Front Electrica l unit Only operate the un it with the c ov er pane l at tach[...]
-
Page 49
HRX-OM-J049-A Chapter 5 Error Mess age and T roubles hooting HRG010-W HRG015-W 5.3 Alarm Reset (Alarm Lamp OFF) 1st edition : Aug. 2006 Rev. A: May. 2007 5-5 3. Press the Reset switch [RS] (yellow button) on the contr ol panel and make sure that the alarm lamp goes out. Fig. 5-4 Location of Reset Sw itch [RS] (Y ellow Button) When the alarm lam[...]
-
Page 50
HRX-OM -J049-A Chapter 5 Error Mess age and T roubles hooting 5.4 Recovery from Power Failure (POWER Lamp ON) HRG010-W HRG015-W 1st edition : Aug. 2006 Rev. A: May. 2007 5-6 5.4 Reco v e ry from Po w er Failure (POWER Lamp ON) Power error ch eck 1. Request an expert engineer to eliminate the cause of a power failure (such as a ground falut and [...]
-
Page 51
HRX-OM-J049-A Chapter 5 Error Mess age and T roubles hooting HRG010-W HRG015-W 5.4 Recovery from Power Failure (POWER Lamp ON) 1st edition : Aug. 2006 Rev. A: May. 2007 5-7 [HRG010-W-B / HRG015-W- B (earth l eakage brea ker-mounted option)] 1. Undo the screws (6 pcs .) to remove the f ront panel. Fig. 5-7 Removal of Front Panel Front pane l Scr[...]
-
Page 52
HRX-OM -J049-A Chapter 5 Error Mess age and T roubles hooting 5.4 Recovery from Power Failure (POWER Lamp ON) HRG010-W HRG015-W 1st edition : Aug. 2006 Rev. A: May. 2007 5-8 2. Check the earth leakage breaker on the electrical board of the electrical unit. Fig. 5-8 Location of Earth Leakage Brea ker (Option a l) 3. Switch off the earth leakage brea[...]
-
Page 53
HRX-OM-J049-A Chapter 6 U nit Maintena nce HRG010-W HRG015-W 6.1 Control of Water Quality 1st edition : Aug. 2006 Rev. A: May. 2007 6-1 Chapter 6 Unit Maintenance 6.1 Control of Wa ter Quality T able 6-1 Water quality stand ards for fresh water (t ap water) Substanc es Facility water spec. Circulating fluid spec. pH (25°C) 6.5 to 8.2 6.0 to 8.0 El[...]
-
Page 54
HRX-OM -J049-A Chapter 6 Unit Maintenan ce 6.2 Inspecti on and Cleaning HRG010-W HRG015-W 1st edition : Aug. 2006 Rev. A: May. 2007 6-2 6.2 Inspectio n and Cleaning A lw ays mount the pan el back onto the unit af t er removing t he panel for inspection or cleaning. Failure to c lose or re-attach the panel may cause personal injury or electric shock[...]
-
Page 55
HRX-OM-J049-A Chapter 6 U nit Maintena nce HRG010-W HRG015-W 6.2 Inspecti on and Cleaning 1st edition : Aug. 2006 Rev. A: May. 2007 6-3 6.2.1 Daily inspection Perform daily inspection of the items listed in the Table 6-2. If the check finds any abnormal ev e nt, s top syst em operation an d turn off t he main power su ppl y. Reques t for servi ce p[...]
-
Page 56
HRX-OM -J049-A Chapter 6 Unit Maintenan ce 6.2 Inspecti on and Cleaning HRG010-W HRG015-W 1st edition : Aug. 2006 Rev. A: May. 2007 6-4 6.2.2 Quarte rl y inspection Replacement of circulating fluid z Per iodic rep lacement o f circ ulating fluid (fresh water) Potential algae growth or aqu eous corrosion m a y occur if the old fl uid is reused. [...]
-
Page 57
HRX-OM-J049-A Chapter 6 Unit Maintenan ce HRG010-W HRG015-W 6.2 Inspecti on and Cleaning 1st edition : Aug. 2006 Rev. A: May. 2007 6-5 6.2.4 Check duri ng wintertime A nti freeze of circulating fluid This unit is resistant to f reezing of the circulating fluid during w intertime and ni ght time. Ensure the following measures are tak en in advan[...]
-
Page 58
HRX-OM -J049-A Chapter 6 Unit Maintenan ce 6.3 Consumables HRG010-W HRG015-W 1st edition : Aug. 2006 Rev. A: May. 2007 6-6 6.3 Consuma bles Replace the following parts in res ponse to the lev e l of wearing out at inspection. T able 6-3 C onsumables Part number Part Qty. Remarks HRG-S0034 Mechanica l seal set 1 set Service part f or HRG010 HRG-S003[...]
-
Page 59
HRX-OM-J049-A Chapter 7 Document s HRG010-W HRG015-W 7.1 Standard Specific ations 1st edition : Aug. 2006 Rev. A: May. 2007 7-1 Chapter 7 Documents 7.1 Standard Sp ecifications T able 7-1 S tandar d S pecifications (1/2) Item HRG010-W HRG015-W Rated ambient temp. 32 ° C ( 5 to 40 ° C) Insta llation Operating environment Humidity range 45 to 75%RH[...]
-
Page 60
HRX-OM -J049-A Chapter 7 Document s 7.1 Standard Specific ations HRG010-W HRG015-W 1st edition : Aug. 2006 Rev. A: May. 2007 7-2 T able 7-1 S tandar d S pecifications (2/2) Item HRG010-W HRG015-W ALARM 1 System st op function fo r low tan k level (t ank le vel sw itch), pump/compress or reverse rotation detection (phase relay) Protecti on against r[...]
-
Page 61
HRX-OM-J049-A Chapter 7 Document s HRG010-W HRG015-W 7.2 Optional Specific ations 1st edition : Aug. 2006 Rev. A: May. 2007 7-3 7.2 Optional Specificatio ns Caster T able 7-2 Caster with Brake Specifi cations Item For HRG010-W-A, HRG015-W-A W heel diameter 63mm Turning radius of the caster 59mm (single) Adjuster height a djustable range 0 to 12[...]
-
Page 62
HRX-OM -J049-A Chapter 7 Document s 7.3 Outline Dimensions HRG010-W HRG015-W 1st edition : Aug. 2006 Rev. A: May. 2007 7-4 7.3 Outline Dime nsions 7.3.1 HRG010-W, HRG010-W- B, HRG010- W-C, HRG010-W-BC HRG015-W, HRG015-W-B, HRG015 -W-C, HRG015-W-BC Fig. 7-1 Outline Di mensions 7.3.2 HRG010-W-A □ , HRG015-W-A □ Fig. 7-2 Outline Di mensions Left F[...]
-
Page 63
HRX-OM-J049-A Chapter 7 Document s HRG010-W HRG015-W 7.4 Electric Circ uit 1st edition : Aug. 2006 Rev. A: May. 2007 7-5 7.4 Electric Circuit 7.4.1 HRG010-W, HRG015-W Fig. 7-3 Electric Cir cuit (HRG010- W, HRG01 5-W )[...]
-
Page 64
HRX-OM -J049-A Chapter 7 Document s 7.4 Electric Circ uit HRG010-W HRG015-W 1st edition : Aug. 2006 Rev. A: May. 2007 7-6 7.4.2 HRG010-W-BC, H RG015-W-BC Fig. 7-4 Electric Cir cuit (HRG010- W -BC, HRG015-W-BC) ★2 ★ 1. GFCI breaker spec. (-B) ★ 2. Communicat ion functi on spec. (-C) ★2 ★2 ★2 ★2[...]
-
Page 65
HRX-OM-J049-A Chapter 7 Document s HRG010-W HRG015-W 7.5 Flow Chart 1st edition : Aug. 2006 Rev. A: May. 2007 7-7 7.5 Flow Chart HRG010- W, HR G015- W Fig. 7-5 Flow Chart (HRG010- W, HR G015- W ) Sym bol Name PV Pressure water regulating valve Facility water S Strainer CM Compressor CD Water condenser HPS High pres sure SW D Refrigerant dryer E[...]
-
Page 66
HRX-OM -J049-A Chapter 7 Document s 7.6 Daily Inspect ion Sheet HRG010-W HRG015-W 1st edition : Aug. 2006 Rev. A: May. 2007 7-8 7.6 Dail y Inspection Sheet T o confirm daily inspecti on items on the Thermo Cool er , See “T able 6-2 Daily Inspection” in “Daily inspecti on” of “Chapter 6 Unit Maintenance. Be sure to record the s ystem condi[...]
-
Page 67
Product W arranty 1. W arrant y If a failure is observed in our Thermo Cooler , repair shall be prov ided in accordance w ith the warran t y period and preconditions defined below at SMC’ s option. Repair involves the inspection and/or replacem e nt and/or m odification of a defective part. Removed part s sh all become the pos session of SMC . 2.[...]