Go to page of
Similar user manuals
-
Switch
Sierra Monitor Corporation ISE30
24 pages 1.78 mb -
Switch
Sierra Monitor Corporation D-J79(W)
2 pages 0.26 mb -
Switch
Sierra Monitor Corporation D-M9PAV
2 pages 0.27 mb -
Switch
Sierra Monitor Corporation D-M9PA
2 pages 0.27 mb -
Switch
Sierra Monitor Corporation D-F79(W)
2 pages 0.26 mb -
Switch
Sierra Monitor Corporation D-M9NA
2 pages 0.27 mb -
Switch
Sierra Monitor Corporation ZSE30
24 pages 1.78 mb -
Switch
Sierra Monitor Corporation D-M9NAV
2 pages 0.27 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Sierra Monitor Corporation ISE30, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Sierra Monitor Corporation ISE30 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Sierra Monitor Corporation ISE30. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Sierra Monitor Corporation ISE30 should contain:
- informations concerning technical data of Sierra Monitor Corporation ISE30
- name of the manufacturer and a year of construction of the Sierra Monitor Corporation ISE30 item
- rules of operation, control and maintenance of the Sierra Monitor Corporation ISE30 item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Sierra Monitor Corporation ISE30 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Sierra Monitor Corporation ISE30, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Sierra Monitor Corporation service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Sierra Monitor Corporation ISE30.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Sierra Monitor Corporation ISE30 item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
Technical Specification Digital Pressure Switch ISE30-# Series ZSE30-# Series No.:PS##-OMF0010-C[...]
-
Page 2
-1- PS##-OMF0010-C Contents Safety Model Indication Method S pecification Ful l V iew w ith Di mension s Names and Functions o f Individual Parts Inst alla tion Examples of Internal Circuit and Wiring Setting Pressure Setting Othe r Functio ns Attached T able ………………………… …………………… ………P2 …………………?[...]
-
Page 3
-2- Th e Digital Pre ssur e Switch a nd this t echn ical s pecif icat ion es sen tial inf orm at ion for t he pro tect ion of users and o thers from possi ble injury and damage to property and to ensure correc t handling. Please check tha t you fully understand the def ini tion of the fol lowing messages (sig ns) be f ore going on to read the tex t[...]
-
Page 4
-3- PS##-OMF0010-C Operator ♦ This technical specification has been written for those who have knowledge of machinery and apparatus that use pneu m atic equipment and have full knowledge of assembly , operat ion and maintenance of such equipment. ♦ Please read this technical speci f ication carefully and underst and it before assembling, operat[...]
-
Page 5
-4- PS##-OMF0010-C NOTE Follow the instruct ion given below when designing, selection and handling your pressure switch. ♦ The instructions on design and selection. Installation, wiring, environment of use, adjustment, operation and maintenance described below must also be followed. ♦ Product specifications • This product designed only for th[...]
-
Page 6
-5- • Blow off all the dust insi de th e pipes before piping the pressure switch. Otherwise it can cause damage or mal f unction. • Clean the inside of the pipe of dust or t ape sealant when screwing pipes or joints. W hen using tape sealant, leave a couple of screw threads unwrapped with tape sealant. Otherwise it can cause damage or mal f unc[...]
-
Page 7
• Do not use a pressure switch nearby a pl ace where el ectric surges are generated. Internal ci rcuit elements of the pressu re switch can deteriorate or b r eak w hen eq uipment generati ng a large surge (el ectromagnetic li fter , high frequency induction furnace, motor , etc.) i s located nea r the pressure sw itch. Prov ide surge preventives[...]
-
Page 8
Model Indication Method For positive pre ssure : I S E 3 0 − − − For vacuum and lo w pressure : Z S E 3 0 − − − Optional Indicat ions Opti on Model n umber Lead W ire with Conn ector ZS-27- A (Le ad wire with Co nnector : 2m) Brack et ZS-27-B (C ontained m ounting s crews : M3 × 5L 2pcs.) Panel Mou nt Adapt er ZS-27-C Panel Mou nt Adap[...]
-
Page 9
ZSE30 ISE30 Rated Pres sure R ange - 100 to 100 k Pa 0 to 1 MPa Set Pressur e Range - 101 to 101 k Pa - 0.1 to 1 MPa W ithstand Pressure 500 kPa 1.5 MPa Setting and Displ ay Resol ut ion 0.2 kPa 0.001 MPa Fluids Air , iner t gases and incom bus tible gas es Power Su ppl y V o ltage 12 to 24V DC, ± 10%,r ipp le (p - p) 10% or les s(Protec ted ag ai[...]
-
Page 10
Full View with Dimensions Dimensions of Main Unit -9- PS##-OMF0010-B Full Vie w with Dimensions[...]
-
Page 11
-10- Bracket supplied Panel Mount T ype With Front face protective PS##-OMF0010-C[...]
-
Page 12
Panel Cut Dimensioms -1 1- PS##-OMF0010-C[...]
-
Page 13
-12- PS##-OMF0010-C Names and Function of Individual P ar ts Operation I ndicator Lam p : Displa ys switc h operat ion cond ition. (Green LCD) LCD Display : Displays the c urrent s tatus of pressu re, setting m ode, sel ected i ndicatio n unit and error code. Fo ur displa y m odes can be s elect ed: dis play al wa ys in red or green only , or chang[...]
-
Page 14
Install usin g the s pecial br ack et (Article No.Z S - 27 - B) or the panel m ount a dapter ( Articl e No.ZS - 27 - C) availabl e as op tions. Caution : Tighten the p ipe port at a clam ping tor que of 7 to 9N ⋅ m. Fasten the br ack et m ounting sc rews at a c lam ping torq ue of 0.5 to 0.7N ⋅ m. Mounting by Bracket Mount the br ack et on the [...]
-
Page 15
Notice when removing the sw itch Digital pres sure s witch with ada pter f or panel m ounting can be r em oved from fac ility by m ak ing hook of the switch wide as follo wing. Press ure switch and Pa nel mount adapt er m ay be dam aged it you p icked up th e hook . Piping connections • Cut the t ube perp endicul arly . • Grasp the tube, s lowl[...]
-
Page 16
Output S pecificat ion W hen the Lead wire with c onnect or prov ided by SMC CORPOR A T ION is us ed, t he color s of wire (Brown, Black , Blue) will ap ply as sho wn on c ircuit diagr am. -15- PS##-OMF0010-C Example of Inter nal Circuit and Wiring[...]
-
Page 17
Connector Connector Co nnect ing/Disconnect ing • W hen conn ectin g the connec tor , ins ert it str aight onto the p in ho lding t he l ever an d co nnector bo dy between f ingers and lock the conn ector b y pushing th e le ver cla w into t he square groove i n the h ousing. • W hen disconnectin g the connec tor , pus h down the lever b y thum[...]
-
Page 18
Setting Setting Procedures Initialize Press the button c ontinuous ly for m ore than two seconds. The displa y shown at the ri ght will pop up to allo w sett ing of a display col or . In the cas e that t he unit s pecif icatio n of m odel in dicati on is M, the SL units will be f ixed. If no s ymbol is s upplied, s ee ”Selecting Indication Unit.?[...]
-
Page 19
4. Response Time Setting A respo nse tim e for s witch output c an be set as user d esires . Se tting o f a respon se time p reven ts chat tering ou tput. The res ponse tim e curr ently set will be d ispla yed. Sele ct a desir ed res ponse t ime by pressing the or button. (2.5ms) (20ms) (160ms) (640ms) (1280ms) Pres s the button to se t and m ove o[...]
-
Page 20
If set to Manual Setting Pr ess the button in th e Measurem ent m ode to dis pla y set values . “P _ 1” or “n _ 1” and the current set value will flicker alternately . Pr ess the button to dis pla y the next set v alue. Press the or button to enter into th e V alu e Change m ode. ( See “V alue S etting”) If Hysteresi s mode is set If th[...]
-
Page 21
If set to Auto Preset Mode Press the button dur ing the Measur ement m ode to r eady Auto Press mode and “AP1” will be d ispla yed. Sett ing pres sure i n this c onditi on will r ead y the equi pm ent. Press the and butto ns s imultaneousl y while “ AP1” is disp la yed to return to the meas urement m ode. T o execute Auto Pres et, pres s th[...]
-
Page 22
Peak And Bottom Hold Displ ay Function Maximum and minimum values are always detected and updat ed during measurement. Displayed values can be hel d. In peak hold, press the button for longer t han one second to make flicker and t o hold the maximum pressure value. T o reset holding, press the button again for more than one second. The Measurement [...]
-
Page 23
PS##-OMF0010-C 1. Displa y color Display Display character Meaning Sor When t ur ning it on, it red displa ys it. SoG When tur ning it on, it green displays it. rEd Red Gr n G reen 2.Output mode Display Display character Meaning no Nor m al open nc Nor m al close 3.K ey loc k Display Displa y character Meaning Loc Lock UnL Unlock 4. A uto Preset Di[...]
-
Page 24
PS##-OMF0010-C 5.Manual set Displa y Displa y character Meaning mAn Manual set Hys Hysteresis mode (Dis play when oper atio n m od e is s et) Wnd Win dow com pa rat or m o de (Dis play when oper atio n m od e is s et) P_1 Hysteresis mode and Win dow com pa rat or m o de (Whe n P_ 1 of t he s etti ng of pr es sur e i s set, it di s plays it.) P_2 Wi[...]