Go to page of
Similar user manuals
-
Network Card
Texas Instruments TPS2330
22 pages 0.74 mb -
Network Card
Texas Instruments DAC7741EVM
28 pages 0.3 mb -
Network Card
Texas Instruments TMS320C6747 DSP
34 pages 0.29 mb -
Network Card
Texas Instruments Adpater
37 pages 0.54 mb -
Network Card
Texas Instruments CDCM7005
34 pages 1.28 mb -
Network Card
Texas Instruments TMS320C6000
62 pages 0.19 mb -
Network Card
Texas Instruments TMS370
99 pages 0.49 mb -
Network Card
Texas Instruments TNETE211
179 pages 0.53 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Texas Instruments SPRU938B, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Texas Instruments SPRU938B one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Texas Instruments SPRU938B. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Texas Instruments SPRU938B should contain:
- informations concerning technical data of Texas Instruments SPRU938B
- name of the manufacturer and a year of construction of the Texas Instruments SPRU938B item
- rules of operation, control and maintenance of the Texas Instruments SPRU938B item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Texas Instruments SPRU938B alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Texas Instruments SPRU938B, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Texas Instruments service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Texas Instruments SPRU938B.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Texas Instruments SPRU938B item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
TMS320DM643x DMP VLYNQ Port User's Guide Literature Number: SPRU938B September 2007[...]
-
Page 2
2 SPRU938B – September 2007 Submit Documentation Feedback[...]
-
Page 3
Contents Preface ............................................................................................................................... 7 1 Introduction ................................................................................................................ 8 1.1 Purpose of the Peripheral ...........................................[...]
-
Page 4
A.2 Special 8b/10b Code Groups ................................................................................. 39 A.3 Supported Ordered Sets ....................................................................................... 39 A.4 VLYNQ 2.0 Packet Format .................................................................................... 40 [...]
-
Page 5
List of Figures 1 VLYNQ Port Functional Block Diagram ................................................................................... 9 2 External Clock Block Diagram ............................................................................................ 10 3 Internal Clock Block Diagram ....................................................[...]
-
Page 6
List of Tables 1 VLYNQ Signal Descriptions ............................................................................................... 11 2 Address Translation Example (Single Mapped Region) .............................................................. 17 3 Address Translation Example (Single Mapped Region) ....................................[...]
-
Page 7
Preface SPRU938B – September 2007 Read This First About This Manual This document describes the VLYNQ port in the TMS320DM643x Digital Media Processor (DMP). Notational Conventions This document uses the following conventions. • Hexadecimal numbers are shown with the suffix h. For example, the following number is 40 hexadecimal (decimal 64): 40[...]
-
Page 8
1 Introduction 1.1 Purpose of the Peripheral 1.2 Features User's Guide SPRU938B – September 2007 VLYNQ Port The VLYNQ™ communications interface port is a low pin count, high-speed, point-to-point serial interface in the TMS320DM643x Digital Media Processor (DMP) used for connecting to host processors and other VLYNQ compatible devices. The[...]
-
Page 9
www.ti.com 1.3 Functional Block Diagram Slave config bus Interface Master config Interface bus VL YNQmodule VL YNQregister access CPU/EDMA initiated transfersto remotedevice Offchip (remote) deviceaccess System CPU/EDMA memory System VL YNQ_SCRUN VL YNQ_CLOCK VL YNQ_RXD[3:0] VL YNQ_TXD[3:0] INT55 interruptcontroller VLQINT 1.4 [...]
-
Page 10
www.ti.com 2 Peripheral Architecture 2.1 Clock Control VL YNQ CLKDIR=0 DMxxxdevice VL YNQ_CLK VL YNQ CLKDIR=0 VL YNQdevice VL YNQ CLKDIR=1 DMxxxdevice VL YNQ_CLK VL YNQ CLKDIR=1 VL YNQdevice VL YNQ internal sysclk Don’t care Peripheral Architecture This section discusses the architecture and basic functions of the VLYNQ peripheral.[...]
-
Page 11
www.ti.com 2.2 Signal Descriptions 2.3 Pin Multiplexing 2.4 Protocol Description Peripheral Architecture The VLYNQ module on the DM643x device supports 1 to 4 bit-wide RX/TX configurations. Chip-level pin multiplexing registers control the configuration. See the pin multiplexing information in the device-specific data manual. If the VLYNQ data widt[...]
-
Page 12
www.ti.com 2.5 VLYNQ Functional Description Address translation commands Outbound Outbound command FIFO data Return FIFO data FIFO Return command Inbound FIFO Registers translation Address TxSM 8B/10B encoding Serializer commands Inbound RxSM Deserializer decoding 8B/10B Serial TxData Serial TxClk Serial RxClk Serial RxData Master configbus inte[...]
-
Page 13
www.ti.com 2.5.1 Write Operations Address translation commands Outbound Outbound command FIFO data Return FIFO data FIFO Return command Inbound FIFO Registers translation Address TxSM 8B/10B encoding Serializer commands Inbound RxSM Deserializer decoding 8B/10B Serial TxData Serial RxData Systemclock Address translation Registers commands Inboun[...]
-
Page 14
www.ti.com 2.5.2 Read Operations Address translation commands Outbound Outbound command FIFO data Return FIFO data FIFO Return command Inbound FIFO Registers translation Address TxSM 8B/10B encoding Serializer commands Inbound RxSM Deserializer decoding 8B/10B Serial TxData Serial RxData Systemclock Address translation Registers commands Inbound[...]
-
Page 15
www.ti.com 2.6 Initialization 2.7 Auto-Negotiation Peripheral Architecture Note: Not servicing read operations results in deadlock. The only way to recover from a deadlock situation is to perform a hard reset. Read operations are typically not serviced due to read requests that are issued to a non-existent remote VLYNQ device or they are not servic[...]
-
Page 16
www.ti.com 2.8 Address Translation Peripheral Architecture Remote VLYNQ device(s) are memory mapped to the local (host) device’s address space when a link is established (this is similar to any other on-chip peripherals). Enumerating the VLYNQ devices (single or multiple) into a coherent memory map for accessing each device is part of the initial[...]
-
Page 17
www.ti.com Mapregion1 Mapregion2 Mapregion3 Mapregion4 0400:0000h (4C00:0000hon DM643xdevice) 0800:0000h 07FF:FFFFh 0800:0100h 0800:00FFh 0801:0100h 0801:00FFh 0841:00FFh Mapregion1 Mapregion2 Mapregion3 Mapregion4 DMxxxdevice(local) Remote VL YNQdevice 0000:0000h 03FF:FFFFh 0400:0000h [...]
-
Page 18
www.ti.com Peripheral Architecture DM643x VLYNQ Module: 4C00 : 0054h Initial address at the slave configuration bus 0000 : 0054h Initial address [25:0] at the slave configuration bus interface subtract 0000 : 0000h TX address map register (there is no need to change the reset value of the DM643x device for this register) 0000 : 0054h Remote VLYNQ M[...]
-
Page 19
www.ti.com 2.9 Flow Control Peripheral Architecture Example 1. Address Translation Example The remote address 0400:0154h (or 0000 0054h) was translated to 8200:0054h on the DM643x (local) device in this example. The translated address for packets received on the serial interface is determined as follows: If ( RX Packet Address < RX Address Map S[...]
-
Page 20
www.ti.com 2.10 Reset Considerations 2.10.1 Software Reset Considerations 2.10.2 Hardware Reset Considerations 2.11 Interrupt Support 2.11.1 Interrupt Events and Requests Peripheral Architecture Peripheral clock and reset control is done through the power and sleep controller (PSC) module that is included with the device. For more information, see [...]
-
Page 21
www.ti.com VL YNQinterrupt pending/setregister (INTPENDSET) VL YNQ Status/clear register (INTST A TCLR) OR T ransmitserial interruptpacket VLQINT (INT55) 14 0 INTLOCAL VL YNQcontrolregister(CTRL) Serialbuserror (LERROR/RERROR) CPUwrites Serialinterrupt packetfrom remotedevice INTLOCAL=1 INTLOCAL=0 2.11.2 Write[...]
-
Page 22
www.ti.com 2.11.3 Remote Interrupts 2.11.4 Serial Bus Error Interrupts 2.12 EDMA Event Support Peripheral Architecture Remote interrupts occur when an interrupt packet is received over the serial interface from a remote device. The interrupt status is extracted from the packet and written to a location pointed to by the interrupt pointer register ([...]
-
Page 23
www.ti.com 2.13 Power Management 2.14 Endianness Considerations 2.15 Emulation Considerations Peripheral Architecture The VLYNQ module can be placed in reduced-power modes to conserve power during periods of low activity. The power management of the VLYNQ module is controlled by the processor Power and Sleep Controller (PSC). The PSC acts as a mast[...]
-
Page 24
www.ti.com 3 VLYNQ Port Registers VLYNQ Port Registers Table 4 describes the address space for the VLYNQ registers and memory. Table 4. VLYNQ Register Address Space Block Name Start Address End Address Size VLYNQ Control Registers 01E0 1000h 01E0 11FFh 512 bytes Reserved 01E0 1200h 01E0 1FFFh - VLYNQ Remote Memory Map 4C00 0000h 4FFF FFFFh 64 Mbyte[...]
-
Page 25
www.ti.com 3.1 Revision Register (REVID) VLYNQ Port Registers The revision register (REVID) contains the major and minor revisions for the VLYNQ module. The REVID is shown in Figure 9 and described in Table 6 . Figure 9. Revision Register (REVID) 31 16 ID R-1h 15 8 7 0 REVMAJ REVMIN R-2h R-6h LEGEND: R = Read only; - n = value after reset Table 6. [...]
-
Page 26
www.ti.com 3.2 Control Register (CTRL) VLYNQ Port Registers The control register (CTRL) determines operation of the VLYNQ module. The CTRL is shown in Figure 10 and described in Table 7 . Figure 10. Control Register (CTRL) 31 30 29 27 26 24 23 22 21 20 19 18 16 PMEN SCLKPUDIS Reserved RXSAMPELVAL RTMVALIDWR RTMENABLE TXFASTPATH Reserved CLKDIV R/W-[...]
-
Page 27
www.ti.com VLYNQ Port Registers Table 7. Control Register (CTRL) Field Descriptions (continued) Bit Field Value Description 7 INT2CFG Interrupt to configuration register. Determines which register is written with the status contained in interrupt packets that are received over the serial interface. Always write 1 to this bit and configure the inter[...]
-
Page 28
www.ti.com 3.3 Status Register (STAT) VLYNQ Port Registers The status register (STAT) is used to detect conditions that may be of interest to the system designer. The STAT is shown in Figure 11 and described in Table 8 . Figure 11. Status Register (STAT) 31 28 27 24 23 20 19 15 Reserved SWIDTHIN SWIDTHOUT Reserved R-0 R-0 R-0 R-0 14 12 11 10 9 8 RX[...]
-
Page 29
www.ti.com VLYNQ Port Registers Table 8. Status Register (STAT) Field Descriptions (continued) Bit Field Value Description 8 RERROR Remote Error. Write a 1 to this bit to clear it. 0 No error This bit indicates that a downstream VLYNQ module has detected a packet error. This bit is 1 set when an error indication, /E/, is received from the serial in[...]
-
Page 30
www.ti.com 3.4 Interrupt Priority Vector Status/Clear Register (INTPRI) 3.5 Interrupt Status/Clear Register (INTSTATCLR) VLYNQ Port Registers The interrupt priority vector status/clear register (INTPRI) displays the highest priority vector with a pending interrupt when read. When writing, only bits [4:0] are valid, and the value represents the vect[...]
-
Page 31
www.ti.com 3.6 Interrupt Pending/Set Register (INTPENDSET) 3.7 Interrupt Pointer Register (INTPTR) VLYNQ Port Registers The interrupt pending/set register (INTPENDSET) indicates the pending interrupt status when the INTLOCAL bit in the control register (CTRL) is not set. When the interrupt packet is forwarded on the serial interface, these bits are[...]
-
Page 32
www.ti.com 3.8 Transmit Address Map Register (XAM) VLYNQ Port Registers The transmit address map register (XAM) is used to translate transmit packet addresses to remote device configuration bus addresses. The XAM is shown in Figure 16 and described in Table 13 . Figure 16. Transmit Address Map Register (XAM) 31 2 1 0 TXADRMAP Reserved R/W-0 R-0 LEG[...]
-
Page 33
www.ti.com 3.9 Receive Address Map Size 1 Register (RAMS1) 3.10 Receive Address Map Offset 1 Register (RAMO1) VLYNQ Port Registers The receive address map size 1 register (RAMS1) is used to identify the intended destination of inbound serial packets. The RAMS1 is shown in Figure 17 and described in Table 14 . Figure 17. Receive Address Map Size 1 R[...]
-
Page 34
www.ti.com 3.11 Receive Address Map Size 2 Register (RAMS2) 3.12 Receive Address Map Offset 2 Register (RAMO2) VLYNQ Port Registers The receive address map size 2 register (RAMS2) is used to identify the intended destination of inbound serial packets. The RAMS2 is shown in Figure 19 and described in Table 16 . Figure 19. Receive Address Map Size 2 [...]
-
Page 35
www.ti.com 3.13 Receive Address Map Size 3 Register (RAMS3) 3.14 Receive Address Map Offset 3 Register (RAMO3) VLYNQ Port Registers The receive address map size 3 register (RAMS3) is used to identify the intended destination of inbound serial packets. The RAMS3 is shown in Figure 21 and described in Table 18 . Figure 21. Receive Address Map Size 3 [...]
-
Page 36
www.ti.com 3.15 Receive Address Map Size 4 Register (RAMS4) 3.16 Receive Address Map Offset 4 Register (RAMO4) VLYNQ Port Registers The receive address map size 4 register (RAMS4) is used to identify the intended destination of inbound serial packets. The RAMS4 is shown in Figure 23 and described in Table 20 . Figure 23. Receive Address Map Size 4 [...]
-
Page 37
www.ti.com 3.17 Chip Version Register (CHIPVER) 3.18 Auto Negotiation Register (AUTNGO) VLYNQ Port Registers VLYNQ allows inter-connection of many VLYNQ devices. In order for software to control the device functions, there must be a mechanism that allows the software to identify VLYNQ devices. Each device that has a VLYNQ module in it has a unique [...]
-
Page 38
www.ti.com 4 Remote Configuration Registers Remote Configuration Registers The remote configuration registers listed in Table 24 are the same registers as previously described, but they are for the remote VLYNQ device. Note: Before attempting to access the remote registers (offsets 80h through C0h) , you must ensure that a link is established with [...]
-
Page 39
www.ti.com Appendix A VLYNQ Protocol Specifications A.1 Introduction A.2 Special 8b/10b Code Groups A.3 Supported Ordered Sets Appendix A VLYNQ relies on 8b/10b block coding to minimize the number of serial pins and allow for in-band packet delineation and control. The following sections include general 8b/10b coding definitions and their implement[...]
-
Page 40
www.ti.com A.3.1 Idle (/I/) A.3.2 End of Packet (/T/) A.3.3 Byte Disable (/M/) A.3.4 Flow Control Enable (/P/) A.3.5 Flow Control Disable (/C/) A.3.6 Error Indication (/E/) A.3.7 Init0 (/0/) A.3.8 Init1 (/1/) A.3.9 Link (/L/) A.4 VLYNQ 2.0 Packet Format bytecnt 10bits cmd2 10bits cmd1 10bits address <4*10bits data N*10bits e[...]
-
Page 41
www.ti.com VLYNQ 2.0 Packet Format Table A-3. Packet Format (10-bit Symbol Representation) Description Field Value Description PKTTYPE[3:0] This field indicates the packet type. 0000 Reserved 0001 Write with address increment. 0010 Reserved 0011 Write 32-bit word with address increment. 0100 Reserved 0101 Configuration write with address increment.[...]
-
Page 42
www.ti.com A.5 VLYNQ 2.X Packets VLYNQ 2.X Packets An example of what can happen to a write burst due to remote and local FIFO state changes and the link pulse timer expiring is shown in Example A-1 . This protocol can be extended to apply to multiple channels; therefore, the data return channel is logically isolated from the command channel. Examp[...]
-
Page 43
www.ti.com VLYNQ 2.X Packets A command, length, address, and start receive data from the idle stream. A flow enable was received for the command channel, but there is data to return, so the flow is followed by a channel 1 descriptor (the command for return data actually indicates a channel 1), and the channel 1 packet is now under way. A flow is no[...]
-
Page 44
www.ti.com Appendix B Write/Read Performance B.1 Introduction B.2 Write Performance Appendix B The following sections discuss the write versus read performance and how the throughput (read or write) should be calculated for a given data width and serial clock frequency. Note: The data and throughput calculations shown here are sample calculations f[...]
-
Page 45
www.ti.com Write Performance Table B-1. Scaling Factors Burst Size in 32-bit words Data Bytes Overhead Bytes Scaling Factor 1 4 6 40% 4 16 7 69.56% 8 32 7 82.05% 16 64 7 90.14% Table B-2. Expected Throughput (VLYNQ Interface Running at 76.5 MHZ and 99 MHZ) Interface Running at 76.5 MHZ Interface Running at 99 MHZ Burst Size in Number of VLYNQ Pins [...]
-
Page 46
www.ti.com B.3 Read Performance Read Performance Since reads must complete a transmit-remote read-receive cycle before starting another read transaction, the data throughput is lower as compared to writes. There is latency involved in reading the data from the remote device; and in some cases, a local latency in writing the returned data before the[...]
-
Page 47
www.ti.com Appendix C Revision History Appendix C Table C-1 lists the changes made since the previous version of this document. Table C-1. Document Revision History Reference Additions/Modifications/Deletions Section 2.8 Changed fourth paragraph. Added NOTE. Section 3.17 Changed paragraph. Figure 25 Changed DEVID reset value. Table 22 Changed DEVID[...]
-
Page 48
IMPORTANT NOTICE Texas Instruments Incorporated and its subsidiaries (TI) reserve the right to make corrections, modifications, enhancements, improvements, and other changes to its products and services at any time and to discontinue any product or service without notice. Customers should obtain the latest relevant information before placing orders[...]