Vermont Casting SDDVTCB, SDDVTEB, SDDVTMB, SDDVTBS, SDDVTCH, SDDVTVG, SDDVTBD,SDDVTCCB, SDDVTCEB, SDDVTCMB, SDDVTCBS, SDDVTCCH, SDDVTCVG, SDDVTCBD manual
- Read online or download the manual
- 52 pages
- 5.81 mb
Go to page of
Similar user manuals
-
Gas Heater
Vermont Casting SDDVREB
52 pages 5.91 mb -
Gas Heater
Vermont Casting SDDVRBS
52 pages 5.91 mb -
Gas Heater
Vermont Casting VCPV18TP - 18
16 pages 0.35 mb -
Gas Heater
Vermont Casting VCBV30TN
16 pages 0.35 mb -
Gas Heater
Vermont Casting VCBV30TP - 30
16 pages 0.35 mb -
Gas Heater
Vermont Casting SDDVRCCH
52 pages 5.91 mb -
Gas Heater
Vermont Casting VCBV10TN
16 pages 0.35 mb -
Gas Heater
Vermont Casting SDDVRBD, SDDVRC, SDDVRCCB
52 pages 5.91 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Vermont Casting SDDVTCB, SDDVTEB, SDDVTMB, SDDVTBS, SDDVTCH, SDDVTVG, SDDVTBD,SDDVTCCB, SDDVTCEB, SDDVTCMB, SDDVTCBS, SDDVTCCH, SDDVTCVG, SDDVTCBD, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Vermont Casting SDDVTCB, SDDVTEB, SDDVTMB, SDDVTBS, SDDVTCH, SDDVTVG, SDDVTBD,SDDVTCCB, SDDVTCEB, SDDVTCMB, SDDVTCBS, SDDVTCCH, SDDVTCVG, SDDVTCBD one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Vermont Casting SDDVTCB, SDDVTEB, SDDVTMB, SDDVTBS, SDDVTCH, SDDVTVG, SDDVTBD,SDDVTCCB, SDDVTCEB, SDDVTCMB, SDDVTCBS, SDDVTCCH, SDDVTCVG, SDDVTCBD. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Vermont Casting SDDVTCB, SDDVTEB, SDDVTMB, SDDVTBS, SDDVTCH, SDDVTVG, SDDVTBD,SDDVTCCB, SDDVTCEB, SDDVTCMB, SDDVTCBS, SDDVTCCH, SDDVTCVG, SDDVTCBD should contain:
- informations concerning technical data of Vermont Casting SDDVTCB, SDDVTEB, SDDVTMB, SDDVTBS, SDDVTCH, SDDVTVG, SDDVTBD,SDDVTCCB, SDDVTCEB, SDDVTCMB, SDDVTCBS, SDDVTCCH, SDDVTCVG, SDDVTCBD
- name of the manufacturer and a year of construction of the Vermont Casting SDDVTCB, SDDVTEB, SDDVTMB, SDDVTBS, SDDVTCH, SDDVTVG, SDDVTBD,SDDVTCCB, SDDVTCEB, SDDVTCMB, SDDVTCBS, SDDVTCCH, SDDVTCVG, SDDVTCBD item
- rules of operation, control and maintenance of the Vermont Casting SDDVTCB, SDDVTEB, SDDVTMB, SDDVTBS, SDDVTCH, SDDVTVG, SDDVTBD,SDDVTCCB, SDDVTCEB, SDDVTCMB, SDDVTCBS, SDDVTCCH, SDDVTCVG, SDDVTCBD item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Vermont Casting SDDVTCB, SDDVTEB, SDDVTMB, SDDVTBS, SDDVTCH, SDDVTVG, SDDVTBD,SDDVTCCB, SDDVTCEB, SDDVTCMB, SDDVTCBS, SDDVTCCH, SDDVTCVG, SDDVTCBD alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Vermont Casting SDDVTCB, SDDVTEB, SDDVTMB, SDDVTBS, SDDVTCH, SDDVTVG, SDDVTBD,SDDVTCCB, SDDVTCEB, SDDVTCMB, SDDVTCBS, SDDVTCCH, SDDVTCVG, SDDVTCBD, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Vermont Casting service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Vermont Casting SDDVTCB, SDDVTEB, SDDVTMB, SDDVTBS, SDDVTCH, SDDVTVG, SDDVTBD,SDDVTCCB, SDDVTCEB, SDDVTCMB, SDDVTCBS, SDDVTCCH, SDDVTCVG, SDDVTCBD.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Vermont Casting SDDVTCB, SDDVTEB, SDDVTMB, SDDVTBS, SDDVTCH, SDDVTVG, SDDVTBD,SDDVTCCB, SDDVTCEB, SDDVTCMB, SDDVTCBS, SDDVTCCH, SDDVTCVG, SDDVTCBD item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
INST ALLER / CONSUMER SAFETY INFORMA TION PLEASE READ THIS MANUAL BEFORE INST ALLING AND USING APPLIANCE. W ARNING! IF THE INFORMA TION IN THIS MANUAL IS NOT FOLLOWED EXACTL Y , A FIRE OR EXPLOSION MA Y RESUL T CAUSING PROPERTY DAMAGE, PERSONAL INJUR Y OR LOSS OF LIFE. FOR YOUR SAFETY Installation and service must be performed by a qualified insta[...]
-
Page 2
2 Sta rdan ce D ir ect V ent/N atur al V ent Gas H eater 20012734 PLEASE READ THE INST ALLA TION & OPERA TING INSTRUCTIONS BEFORE USING APPLIANCE. Thank you and congratulations on your purchase of a V ermont Castings stove. IMPORT ANT : Read all instructions and warnings carefully before starting installation. Failure to follow these instructio[...]
-
Page 3
3 Sta rda nce Direct V ent/N a t ur al V ent Gas H ea te r 20012734 General Information The Stardance Direct V ent/Natural V ent Room Heater , Model Nos. SDDVTCB, SDDVTEB, SDDVTMB, SDDVTBS, SDDVTCH, SDDVTVG, SDDVTBD, SDDVTCCB, SDDVTCEB, SDDVTC- MB, SDDVTCBS, SDDVTCCH, SDDVTCVG, SDDVTCCBD, is a vented gas appliance listed to the ANSI standard Z21.88[...]
-
Page 4
4 Sta rdan ce D ir ect V ent/N atur al V ent Gas H eater 20012734 Installation Requirements Requirements for the Commonwealth of Massachusetts All gas fitting and installation of this heater shall only be done by a licensed gas fitter or licensed plumber . For all side wall horizontally vented gas fueled equipment installed in every dwelling, bui[...]
-
Page 5
5 Sta rda nce Direct V ent/N a t ur al V ent Gas H ea te r 20012734 Stardance Direct V ent / Natural V ent Dimensions 26 " (680 mm) 25 " (654 mm) 14 " (355 mm) 3" (76 mm) C L 12734 Stardance dim 8/07 djt Supply Inlet 9" (229 mm) C L 7" Outer Dia. (178 mm) Flue Collar L C Supply Inlet SDDVT[...]
-
Page 6
6 Sta rdan ce D ir ect V ent/N atur al V ent Gas H eater 20012734 Clearance Requirements Minimum Clearances to Combustible Materials Measure side clearances as shown in Figures 3 and 4 from the outer edge of the cast iron stove top. Measure rear clearances from the outermost surface of the steel rear skirt. The Stardance heater is approved for inst[...]
-
Page 7
7 Sta rda nce Direct V ent/N a t ur al V ent Gas H ea te r 20012734 ST128b Stardance flue centerline 9/28/00 djt C L C L B D C A Parallel Installation: Minimum Clearance and Flue Centerline, Direct V ent and Natural V ent ST128b Stove Clearances: A: 4” (102 mm) B: 4” (102 mm) Pipe Centerlines: C: 15 ¹⁄₂ ” (395 mm) D: 9” (229 mm) Fig. 3[...]
-
Page 8
8 Sta rdan ce D ir ect V ent/N atur al V ent Gas H eater 20012734 Weight: Fully assembled; 202 lbs. Gas Inlet and Manifold Pressures Natural LP (Propane) Inlet Minimum 5.5” w .c. 1 1.0” w .c. Inlet Maximum 14.0” w .c. 14.0” w .c. Manifold Pressure 3.5” w .c. 10” w .c. Stardance Direct V ent / Natural V ent Certified to: ANSI Z21.88-200[...]
-
Page 9
9 Sta rda nce Direct V ent/N a t ur al V ent Gas H ea te r 20012734 V ertical T ermination - Direct V ent ONL Y A vertical vent system must terminate no less than 8’ (2.44m) and no more than 40’ (12m) above the appli- ance flue collar . A restrictor plate (supplied) must be used where specified in all vertically terminated vent systems. (Fig.[...]
-
Page 10
10 Sta rdan ce D ir ect V ent/N atur al V ent Gas H eater 20012734 When planning the installation, consider the location of the vent terminal and clearances. Some of the most common clearances to keep in mind are shown in Figure 1 1. Important: All vent clearances must be maintained. Check your vent termination clearances against Figures 1 1 throug[...]
-
Page 11
1 1 Sta rda nce Direct V ent/N a t ur al V ent Gas H ea te r 20012734 General V enting Information - T ermination Location V V V V V V V X X X D E B B B C B M B A J K F L VENT TERMINA TION AIR SUPPL Y INLET AREA WHERE TERMINAL IS NOT PERMITTED H I Operable Operable Fixed Closed V B CFM145a DV T ermin Location 5/01[...]
-
Page 12
12 Sta rdan ce D ir ect V ent/N atur al V ent Gas H eater 20012734 Fig. 12 T ermination clearances. V enting Requirements - Natural V ent Only FP567 NVBR/NVBC VENTING RUNS 1 1/12/97 V enting Runs Horizontal Run (in feet) V ertical Run (in feet) (Measured from top of the unit before any elbow) A: V ertical installations up to 36 feet (12m) in height[...]
-
Page 13
13 Sta rda nce Direct V ent/N a t ur al V ent Gas H ea te r 20012734 V enting Requirements and Options - Direct V ent ONL Y Approved V ent System Components The Stardance Heater must be vented to the outdoors through an adjacent exterior wall or through the roof. The venting system must be comprised of the appropri- ate listed venting components sp[...]
-
Page 14
14 Sta rdan ce D ir ect V ent/N atur al V ent Gas H eater 20012734 CFM V ent Components The following kits are available to meet the needs of most installations. All pipe has a 7” outer diameter and includes a 4” diameter inner section. A (CG) designa- tion indicates the part is finished in Charcoal Gray paint. Consult your dealer about other [...]
-
Page 15
15 Sta rda nce Direct V ent/N a t ur al V ent Gas H ea te r 20012734 Install the Optional Fan If you are installing the optional convection Fan Kit #2767 (FK26), continue here. If you are not installing a Fan Kit, go to Page 16, V enting System Assembly . 1. The fan kit includes a Blower Assembly and a Rheo- stat Assembly , connected by a cable. (F[...]
-
Page 16
16 Sta rdan ce D ir ect V ent/N atur al V ent Gas H eater 20012734 V enting System Assemlby - Direct V ent General Information The Stardance is approved for installation only with the vent components listed on Pages 13 & 14. Follow the vent component instructions exactly . For U.S. installations: The venting system must con- form with local cod[...]
-
Page 17
17 Sta rda nce Direct V ent/N a t ur al V ent Gas H ea te r 20012734 ST355b dura vent attach inner assy no restrictor plate 6/07 djt CEMENT 1/4-20 x 3/8 Phillips Screws Inner Adapter Pipe ST355b Fig. 21 Simpson Dura-V ent - install inner adapter pipe. ST356 dura v ent attach outer assy 4/7/00 djt ST356a Fig. 22 Simpson Dura-V ent - instal[...]
-
Page 18
18 Sta rdan ce D ir ect V ent/N atur al V ent Gas H eater 20012734 including a 2” overlap at the joint. (Fig. 25) use a hacksaw or tin snips to trim the pipe as needed. 5. Install first the inner then the outer straight pipe section(s), trimmed end down, to the point of the el- bow . Drill 3 holes through each joint and fasten with sheet metal s[...]
-
Page 19
19 Sta rda nce Direct V ent/N a t ur al V ent Gas H ea te r 20012734 ST218 install snorkel 12/6/99 djt W aterproof Seal Around PIpe Firestop W all Screws and Anchors Snorkel T ermination Cap Drain Window Well ST218a Fig. 29 Snorkel kit installation. ST219 snorkel detail 12/6/99 djt Recessed W all Sheet Metal Screws and Bracket W all Scr[...]
-
Page 20
20 Sta rdan ce D ir ect V ent/N atur al V ent Gas H eater 20012734 ST222 vent thru ceiling 12/99 #7DV AIS Attic Insulation Shield #7DVFS Firestop in Upper Floor #7DVFS Firestop in Ceiling Use Four 8dNails ST222 Fig. 31 Install firestops and attic insulation shield. ST221 vent thru roof 12/99 Sealant Storm Collar Use three #5 sheet metal scre[...]
-
Page 21
21 Sta rda nce Direct V ent/N a t ur al V ent Gas H ea te r 20012734 V ent T ermination (VC) Storm Collar (SC) Roof Flashing (AF) Ceiling Support (CS) T rim Plate (TP) Pipe Length Pipe Length Appliance Adapter (AA V) ST924 V ertical V enting Gasket Lock T ab Inlet End Outlet End ST9[...]
-
Page 22
22 Sta rdan ce D ir ect V ent/N atur al V ent Gas H eater 20012734 Supporting DIRECT -TEMP: V ertical Support V ertical installations can be supported by two methods: Ceiling Support (CS) (used in flat ceiling installation) comes with a support plate and a support collar . Install it by screwing the support plate to the top of the prop- erly frame[...]
-
Page 23
23 Sta rda nce Direct V ent/N a t ur al V ent Gas H ea te r 20012734 Consider locating the appliance in a place where there will be no interference with wall studs, electrical wir- ing, conduit, plumbing pipe or other obstructions. The termination should be located at least 12” (305 mm) (Fig. 39) above grade, remain above the snow line in geograp[...]
-
Page 24
24 Sta rdan ce D ir ect V ent/N atur al V ent Gas H eater 20012734 Horizontal T ermination ST931 Fig. 41 Horizontal termination. ST932 Selkirk standoff 6/07 Vinyl Siding Standof f ST932 Horizontal T ermination Fig. 42 Vinyl siding standof f and[...]
-
Page 25
25 Sta rda nce Direct V ent/N a t ur al V ent Gas H ea te r 20012734 6. Install the ceiling support cathedral ceiling support box assembly , as appropriate. 7. Determine the distance from the appliance outlet to a point just above [approximately 12” (305 mm) to 24” (610 mm)] either the cathedral ceiling support box or the ceiling support plate [...]
-
Page 26
26 Sta rdan ce D ir ect V ent/N atur al V ent Gas H eater 20012734 For U.S. installations: The venting system must con- form with local codes and/or the current National Fuel Gas Code, ANSI Z22.1. For Canadian installations: The venting system must conform to the current CSA B149.1 installation code. Install the V ent Pipe Apply a bead of sealant a[...]
-
Page 27
27 Sta rda nce Direct V ent/N a t ur al V ent Gas H ea te r 20012734 Left Log Right Log Figure 48 LG494 Rear Log T op Log Left Log Right Log Ember Bed LG495 Figure 49 3. Install the left[...]
-
Page 28
28 Sta rdan ce D ir ect V ent/N atur al V ent Gas H eater 20012734 Connect the Gas Supply Line Check the Rating Plate attached by a steel cable to the firebox, to confirm that you have the appropriate firebox for the type of fuel to be used. The Stardance may be converted from one gas to another using the appropri- ate Fuel Conversion Kit listed[...]
-
Page 29
29 Sta rda nce Direct V ent/N a t ur al V ent Gas H ea te r 20012734 Thermostat Connection (optional) Use only a thermostat rated for 500 millivolts. Check the table below for the appropriate gauge ther- mostat wire to use for the length of lead required in your installation. Thermostat W ire / Gauge Maximum Run 18 20 feet 16 20 - 40 feet 14 up to [...]
-
Page 30
30 Sta rdan ce D ir ect V ent/N atur al V ent Gas H eater 20012734 Flame & T emperature Adjustment For stoves equipped with HI/LO valves, flame adjust- ment is accomplished by rotating the HI/LO adjustment knob located near the center of the gas control valve. (Fig. 54) Fig. 54 Flame adjustment knob for SIT valve. L O H I FP390 FLAME ADJUSTMEN[...]
-
Page 31
31 Sta rda nce Direct V ent/N a t ur al V ent Gas H ea te r 20012734 3. Open control access panel. 4. Push in gas control knob slightly and turn clock- wise to “OFF”. Do not force. 5. Close control access panel. 1. STOP! Read the safety information above. 2. Turn of f all electrical power to the fireplace. 3. Turn the ON/OFF switch to “OFF?[...]
-
Page 32
32 Sta rdan ce D ir ect V ent/N atur al V ent Gas H eater 20012734 T roubleshooting the Gas Control System (SDDVT Series) NOTE : Before trouble shooting the gas control system, be sure external gas shut off is in the “On” position. SIT NOV A 820 MILLIVOL T V AL VE Symptom 1. Spark ignitor will not light 2. Pilot will not stay lit after carefull[...]
-
Page 33
33 Sta rda nce Direct V ent/N a t ur al V ent Gas H ea te r 20012734 Instructions for RF Comfort Control V alve SDDVTC Series The Comfort Control valve allows remote control of tem- perature, fan and flame appearance. NOTE: The antenna should hang in free air away form grounded metal. Operation 1. If the manual switch is in remote position, switch[...]
-
Page 34
34 Sta rdan ce D ir ect V ent/N atur al V ent Gas H eater 20012734 Auto Mode In the AUT O mode, the room temperature, set tem- perature, flame and fan levels will be shown. AUTO will appear next to both the flame and fan icons. When the control is in the AUT O mode, the main burner will turn on/off or modulate based on the heat needed to maintain[...]
-
Page 35
35 Sta rda nce Direct V ent/N a t ur al V ent Gas H ea te r 20012734 Comfort V alve System Control Sequence of Operation with T ransmitter Set manual switch to local or remote five minute wait period Light pilot burner Did the LED stop blinking? Review LED failure analysis Release pilotstat knob T urn pilotstat knob from PILOT to ON Cycle switch o[...]
-
Page 36
36 Sta rdan ce D ir ect V ent/N atur al V ent Gas H eater 20012734 If the manual switch is set to REMOTE, press the mode button to display AUTO on the transmitter . Does the transmitter dis- play the room and tempera- ture setting? Auto Path Move switch from LOCAL to REMOTE. Press any key within 30 seconds. If the setting is above room temperature [...]
-
Page 37
37 Sta rda nce Direct V ent/N a t ur al V ent Gas H ea te r 20012734 Fuel Conversion Instructions W ARNING! This conversion kit shall be installed by a qualified service agency in accordance with the manufacturer ’ s instructions and all applicable codes and requirements of the authority having jurisdiction. If the information in these instruc- [...]
-
Page 38
38 Sta rdan ce D ir ect V ent/N atur al V ent Gas H eater 20012734 FP1037b comfort valve convert 3/6/01 djt LOCAL REMOTE ON • PILOT OFF • LED Motor T op Cap Center Plunger Blue - NG Red - LP V alve FP1037b Fig. 65 Depress and turn center plunger . 3. Remove motor top cap using a standard slotted screwdriver . Depress and turn center plunger unt[...]
-
Page 39
39 Sta rda nce Direct V ent/N a t ur al V ent Gas H ea te r 20012734 Remove Nuts Remove Nut Bottom View Fig. 71 Remove three (3) nuts securing ember bed in place. ST918 Pem Studs ST919 Fig. 72 T ilt ember bed slight[...]
-
Page 40
40 Sta rdan ce D ir ect V ent/N atur al V ent Gas H eater 20012734 Conversion to Natural Gas Input (BTU/h) Model Kit # Orifice Part # Minimum Maximum SDDVT 20012903 20,000 SDDVTC 20012905 #38 / .101” 20009310 22,000 28,000 T able 2. Injector Orifice Size Matrix Conversion to LP Input (BTU/h) Model Kit # Orifice Part # Minimum Maximum SDDVT 200[...]
-
Page 41
41 Sta rda nce Direct V ent/N a t ur al V ent Gas H ea te r 20012734 Maintenance Y our Stardance Gas Heater will provide years of service with minimal upkeep. The following procedures will help ensure that your stove continues to function properly . Annual System Inspection Have the entire heater and venting system inspected annually by a qualifie[...]
-
Page 42
42 Sta rdan ce D ir ect V ent/N atur al V ent Gas H eater 20012734 ST208 glass s wivel latch 12/99 ST208 Fig. 76 Release the latches to release the glass frame. Gasket Replacement The Stardance Gas Heater uses a ‘tadpole’ type gasket to seal between the glass panel and the frame. In time, this gasket can become brittle and compressed and [...]
-
Page 43
43 Sta rda nce Direct V ent/N a t ur al V ent Gas H ea te r 20012734 OFF ON Thermostat (Optional) Therm opile Black Black Millivolt Gas Valve St124b on/off/s witch wiring 1/11/00 djt TP/TH TP TH Wiring Diagrams ST124b On/Off Switch Wiring Thermostat (Optional) Therm opile Black Black Millivolt Gas Valve St124c Ther m[...]
-
Page 44
44 Sta rdan ce D ir ect V ent/N atur al V ent Gas H eater 20012734 1a 1b 1c CEMENT 42 12 1 1 10 35 39 12734 Stardance SDDVT/TC parts 6/07 30a,b 40 9 LOCAL REMOTE ON • PILOT OFF • LED 3 4 6 5 20a 22 23 21 24 26 25 20b 20c 27 38 33 41 7 8 36 17 18 31 1d 1 2 16 19 34 37 13 14 15 28a,b 29a,b 50 51 CFM Corporation reserves the right to make changes [...]
-
Page 45
45 Sta rda nce Direct V ent/N a t ur al V ent Gas H ea te r 20012734 Ref. Description SDDVT/SDDVTC 1. Log Set - Complete 20012551 1a. Log Rear 20012546 1b. Log Right 20012548 1c. Log Left 20012547 1d. Log T op 20012915 2. Ember Bed Assembly 20012492 3. T op Refer to Enamel Parts Chart 4. Front, Operable Door Refer to Enamel Parts Chart 5. Door Righ[...]
-
Page 46
46 Sta rdan ce D ir ect V ent/N atur al V ent Gas H eater 20012734 Stardance Direct V ent/Natural V ent Gas Heater SDDVT Series: SDDVTCB, SDDVTEB, SDDVTMB, SDDVTBS, SDDVTCH, SDDVTVG, SDDVTBD, SDDVTC Series: SDDVTCCB, SDDVTCEB, SDDVTCMB, SDDVTCBS, SDDVTCCH, SDDVTCVG, SDDVTCBD Ref. Description SDDVT/SDDVTC 31. Ignitor Piezo w/Nut SIT 52464 32. Bracke[...]
-
Page 47
47 Sta rda nce Direct V ent/N a t ur al V ent Gas H ea te r 20012734 Optional Accessories Fan Kits FK26 Fan The FK26 fan helps distribute heated air from within the firebox out into the room. The fan is controlled by a snapstat that turns power on and off as the firebox tem- perature rises above and falls below a preset tempera- ture. A rheostat [...]
-
Page 48
48 Sta rdan ce D ir ect V ent/N atur al V ent Gas H eater 20012734[...]
-
Page 49
49 Sta rda nce Direct V ent/N a t ur al V ent Gas H ea te r 20012734[...]
-
Page 50
50 Sta rdan ce D ir ect V ent/N atur al V ent Gas H eater 20012734[...]
-
Page 51
51 Sta rda nce Direct V ent/N a t ur al V ent Gas H ea te r 20012734 LIMITED LIFETIME W ARRANTY CFM Corporation (hereinafter referred to as CFM) warrants that all cast iron parts, the combustion chamber , ceramic burner , and heat exchanger of every V ermont Castings gas product will be free of defective material or workmanship during the period th[...]
-
Page 52
2695 Meadowvale Blvd. • Mississauga, Ontario, Canada L5N 8A3 800-668-5323 • www .cfmcorp.com CFM Corporation[...]