Go to page of
Similar user manuals
-
Fryer
Vulcan-Hart GR85
24 pages 3.23 mb -
Fryer
Vulcan-Hart ML-136657
26 pages 0.97 mb -
Fryer
Vulcan-Hart GR45F
24 pages 3.23 mb -
Fryer
Vulcan-Hart ML-136648
26 pages 2.17 mb -
Fryer
Vulcan-Hart EF5 ML-114944
16 pages 6.12 mb -
Fryer
Vulcan-Hart 4GR45CF ML-136437
27 pages 1.74 mb -
Fryer
Vulcan-Hart ML-136795
26 pages 2.17 mb -
Fryer
Vulcan-Hart 3GR45DF
28 pages 2.43 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Vulcan-Hart LG400, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Vulcan-Hart LG400 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Vulcan-Hart LG400. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Vulcan-Hart LG400 should contain:
- informations concerning technical data of Vulcan-Hart LG400
- name of the manufacturer and a year of construction of the Vulcan-Hart LG400 item
- rules of operation, control and maintenance of the Vulcan-Hart LG400 item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Vulcan-Hart LG400 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Vulcan-Hart LG400, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Vulcan-Hart service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Vulcan-Hart LG400.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Vulcan-Hart LG400 item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
INSTALLATION & OPERATIONAL MANUAL LG SERIES GAS FRYERS M O D E L S : LG300 ML-136528 LG400 ML-136622 LG500 ML-136643 For additional information on Vulcan-Hart or to locate an authorized parts and service provider in your area, visit out website at www.vulcanhart.com VULCAN-HART 3600 NORTH POINT BLVD. DIVISION OF ITW FOOD EQUIPMENT GROUP, LLC BA[...]
-
Page 2
LG SERIES GAS FRYERS VULCAN-HART F -32910 Rev. H (April 2008) -2- IMPORTANT FOR YOUR SAFETY THIS MANUAL HAS BEEN PREPARED FOR PERSONNEL QUALIFIED TO INSTALL GAS EQUIPMENT, WHO SHOULD PERFORM THE INITIAL FIELD START-UP AND ADJUSTMENTS OF THE EQUIPMENT COVERED BY THIS MANUAL. POST IN A PROMINENT LOCATION THE INSTRUCTIONS TO BE FOLLOWED IN THE EVENT T[...]
-
Page 3
LG SERIES GAS FRYERS VULCAN-HART F -32910 Rev. H (April 2008) -3- TABLE OF CONTENTS IMPORTANT FOR YOUR SAFETY………………………………………. 2 INTRODUCTION…………………………………………………………… 4 GENERAL…………………………………………………………… 4 ORDERING PARTS……………[...]
-
Page 4
LG SERIES GAS FRYERS VULCAN-HART F -32910 Rev. H (April 2008) -4- INTRODUCTION GENERAL Vulcan Fryers are produced wit h quality workmanship and mate rial. Proper installation, usage and maintenance will result in year s of satisfactory performance. Before installing the fryer, thoroughly read th is manual and carefully fo llow all instruction. This[...]
-
Page 5
LG SERIES GAS FRYERS VULCAN-HART F -32910 Rev. H (April 2008) -5- INSTALLATION Before installing the fryer, veri fy that the type of gas (natural or propane) agrees with the specifications on the fryer data pl ate, which is located on the inside of the door panel. Make sure the fryer is configur ed for the proper elevation. Record your fryer model,[...]
-
Page 6
LG SERIES GAS FRYERS VULCAN-HART F -32910 Rev. H (April 2008) -6- CODES AND STANDARDS The fryer must be insta lled in accordance with: In the United States: State and local codes, or in the absence of local codes, with: National Fuel Gas Code, ANSI-Z223.1/NFPA #54 (latest edition). Copies may be obtained from The American Gas Association Ac[...]
-
Page 7
LG SERIES GAS FRYERS VULCAN-HART F -32910 Rev. H (April 2008) -7- Locate the fryer under a hood with adequate connection to an exhaust duct. The hood must extend 6” ( 15 cm) beyond fryer on both sides. Clearance above the fryer should be adequate for combustion byproducts to be removed efficiently. An 18” (46 cm) minimum clearance s[...]
-
Page 8
LG SERIES GAS FRYERS VULCAN-HART F -32910 Rev. H (April 2008) -8- Make sure the pipes are clean and free of obstructions, dirt, and piping compound. A battery requires one or two connections of appropriate size for the gas requirement. Prior to lighting, check all joints in the g as supply line for leaks. Use soap and water solution. Do not use an [...]
-
Page 9
LG SERIES GAS FRYERS VULCAN-HART F -32910 Rev. H (April 2008) -9- When installing a quick disconnect you must also install a means for limiting the movement of the fryer. This device wil l prevent the gas line or quick disconnect from being strained. The rest raining device should be attached to the cutout on the back panel. See illustration fo[...]
-
Page 10
LG SERIES GAS FRYERS VULCAN-HART F -32910 Rev. H (April 2008) -10- OPERATION Hot oil and parts can cause burns. Use care when operating, cleaning and servicing the fryer. Spilling hot frying compound can cause severe burns. Do not move fryer without draining all frying compound from the tank. OVER-TEMPERATURE SHUTDOWN If the shortening becomes over[...]
-
Page 11
LG SERIES GAS FRYERS VULCAN-HART F -32910 Rev. H (April 2008) -11- FILLING TANK WITH SHORTENING Solid shortening should NOT be used with LG300 fryers. Melting solid shortening will damage the tank and void your warranty. Close the drain valve. Fill the fryer tank wit h liquid shortening. Shortening level should be between the min and ma[...]
-
Page 12
LG SERIES GAS FRYERS VULCAN-HART F -32910 Rev. H (April 2008) -12- LIGHTING THE PILOT 1. Open the door. 2. Turn the thermostat OFF (s ee figure below, view A). The thermostat is located behind the door. 3. Push the gas control valve knob and turn to OFF. Wait 5 minutes for unburned gas to vent. 4. Push and turn gas control valve knob to the “L”[...]
-
Page 13
LG SERIES GAS FRYERS VULCAN-HART F -32910 Rev. H (April 2008) -13- TURNING ON THE FRYER Set the temperature knob to desired temperature. After the set temperature has been reac hed, the thermostat shuts off the gas flow to burners. The pilot remains lit. The burners wil l cycle on and off, maintaining the set temperature. TURNING OFF TH[...]
-
Page 14
LG SERIES GAS FRYERS VULCAN-HART F -32910 Rev. H (April 2008) -14- Fry Basket Guidelines Do not overfill baskets. (See table for recommended basket capacities below) Carefully lower basket into oil. When frying doughnuts and fritters, turn product only once during frying. When cooking French fries or onion rings, shake the basket severa[...]
-
Page 15
LG SERIES GAS FRYERS VULCAN-HART F -32910 Rev. H (April 2008) -15- DRAINING THE TANK 1. Turn the thermostat to OFF. 2. To keep the pilot lit, turn the gas valve to PILOT. 3. Direct the drain spout into the container t hat you want to drain the shortening into. 4. Open the drain valve. The oil will drain into the container. When the container is ful[...]
-
Page 16
LG SERIES GAS FRYERS VULCAN-HART F -32910 Rev. H (April 2008) -16- CLEANING Hot oil and hot parts can cause burns. Use care when operating, cleani ng, and servicing the fryer. Daily Clean your fryer regularly wit h the tank brush along with a damp cloth, and polish with a soft dry cloth. If regular cleani ng is neglected, grease will be burned on a[...]
-
Page 17
LG SERIES GAS FRYERS VULCAN-HART F -32910 Rev. H (April 2008) -17- Remove discolorations by washing with any detergent or soap and water. Use a self-soaping, non-metallic scouring pad for particularly stubborn discolorations. Always rub with the grain of the stainless steel. Do not use a metallic scoring pad or harsh cleaners. BOIL [...]
-
Page 18
LG SERIES GAS FRYERS VULCAN-HART F -32910 Rev. H (April 2008) -18- MAINTENANCE Hot oil and hot parts can cause burns. Use care when operating, clean ing, and servicing the fryer. Spilling hot fryer com pound can cause severe burns. Do not move fryer without draining all frying compound from the tank. FLUE VENT INSPECTION When the fryer is cool, ins[...]