American Power Conversion SUOL1000UXI manual
- Ver online ou baixar oubaixar o manual
- 16 páginas
- 0.74 mb
Ir para a página of
Manuais similares
-
Power Supply
American Power Conversion XR
56 páginas 13.44 mb -
Power Supply
American Power Conversion K250EI
40 páginas 0.29 mb -
Power Supply
American Power Conversion 230
16 páginas 0.16 mb -
Power Supply
American Power Conversion UXI/UXICH
20 páginas 0.37 mb -
Power Supply
American Power Conversion MX06 100
37 páginas 2.01 mb -
Power Supply
American Power Conversion AP9221EXPX166
20 páginas 0.92 mb -
Power Supply
American Power Conversion 60kW InfraStruXureTM System
60 páginas 1.78 mb -
Power Supply
American Power Conversion 1609
14 páginas 0.63 mb
Bom manual de uso
As regras impõem ao revendedor a obrigação de fornecer ao comprador o manual com o produto American Power Conversion SUOL1000UXI. A falta de manual ou informações incorretas fornecidas ao consumidor são a base de uma queixa por não conformidade do produto com o contrato. De acordo com a lei, pode anexar o manual em uma outra forma de que em papel, o que é frequentemente utilizado, anexando uma forma gráfica ou manual electrónicoAmerican Power Conversion SUOL1000UXI vídeos instrutivos para os usuários. A condição é uma forma legível e compreensível.
O que é a instrução?
A palavra vem do latim "Instructio" ou instruir. Portanto, no manual American Power Conversion SUOL1000UXI você pode encontrar uma descrição das fases do processo. O objetivo do manual é instruir, facilitar o arranque, a utilização do equipamento ou a execução de determinadas tarefas. O manual é uma coleção de informações sobre o objeto / serviço, um guia.
Infelizmente, pequenos usuários tomam o tempo para ler o manual American Power Conversion SUOL1000UXI, e um bom manual não só permite conhecer uma série de funcionalidades adicionais do dispositivo, mas evita a formação da maioria das falhas.
Então, o que deve conter o manual perfeito?
Primeiro, o manual American Power Conversion SUOL1000UXI deve conte:
- dados técnicos do dispositivo American Power Conversion SUOL1000UXI
- nome do fabricante e ano de fabricação do dispositivo American Power Conversion SUOL1000UXI
- instruções de utilização, regulação e manutenção do dispositivo American Power Conversion SUOL1000UXI
- sinais de segurança e certificados que comprovam a conformidade com as normas pertinentes
Por que você não ler manuais?
Normalmente, isso é devido à falta de tempo e à certeza quanto à funcionalidade específica do dispositivo adquirido. Infelizmente, a mesma ligação e o arranque American Power Conversion SUOL1000UXI não são suficientes. O manual contém uma série de orientações sobre funcionalidades específicas, a segurança, os métodos de manutenção (mesmo sobre produtos que devem ser usados), possíveis defeitos American Power Conversion SUOL1000UXI e formas de resolver problemas comuns durante o uso. No final, no manual podemos encontrar as coordenadas do serviço American Power Conversion na ausência da eficácia das soluções propostas. Atualmente, muito apreciados são manuais na forma de animações interessantes e vídeos de instrução que de uma forma melhor do que o o folheto falam ao usuário. Este tipo de manual é a chance que o usuário percorrer todo o vídeo instrutivo, sem ignorar especificações e descrições técnicas complicadas American Power Conversion SUOL1000UXI, como para a versão papel.
Por que ler manuais?
Primeiro de tudo, contem a resposta sobre a construção, as possibilidades do dispositivo American Power Conversion SUOL1000UXI, uso dos acessórios individuais e uma gama de informações para desfrutar plenamente todos os recursos e facilidades.
Após a compra bem sucedida de um equipamento / dispositivo, é bom ter um momento para se familiarizar com cada parte do manual American Power Conversion SUOL1000UXI. Atualmente, são cuidadosamente preparados e traduzidos para sejam não só compreensíveis para os usuários, mas para cumprir a sua função básica de informação
Índice do manual
-
Página 1
990 -1137, 3 /02 APC Smart-UPS ® On-Line UX Models SUOL1000UXI and SUOL200 0UXI 220/230/240 Tower/Rack Mount Uninterr uptible Pow er Suppl y User’s Manual English[...]
-
Página 2
[...]
-
Página 3
1 990 -1137, 3/02 1: I NST A LLA TION U NPACKING Inspect the UPS upon receipt. A PC designed robus t packaging for your product. How ever, accidents and damag e may occur during sh ipment. Notify the carrier an d dealer if there is damage. The packaging is recyclable; save it for reuse or dis pose of it properly . Check the packag e contents. The s[...]
-
Página 4
990 -1137, 3 /02 2 2. C ONNECT THE E XTERNAL B ATTERI ES 3. C ONNECT THE EQUIPM ENT TO THE UPS AND C ONNECT THE UPS TO THE AC P OWER S UPPLY 1. On the back pan el, plug the female end of the power cord in to the receptacle. Then plug the male end into a tw o-pole, three-wire, g rounding receptacle. Av oid using ex tension cords and adapter plugs. 2[...]
-
Página 5
3 990 -1137, 3/02 5. P ROGRAMMING S MART - UPS O N - LINE WITH A PPR OPRI ATE N UMBER OF B ATTERY P ACKS It is important to follow these instr uctions. The number of batteries affects the run time calculations the Smart-UPS On-Line performs when it is running on battery power. 5A. U SING P OWER C HUTE ® PLUS V ERSIO N 5. X FOR W INDOWS 95, W INDOW[...]
-
Página 6
990 -1137, 3 /02 4 3: O PERA TION F RONT P ANE L Power On Power Off For P osit i on O nly | Cold Start When the UPS is off and there is no utility power, us e the cold start feature to apply power to th e connected equipment f rom the UPS’s battery. Cold start is not a normal condition. To cold start the unit, push and hold the button. You will h[...]
-
Página 7
5 990 -1137, 3/02 U TILITY P OWER During normal operation, the UPS monitors the utility power and delivers po wer to the connected equip me nt. I f your syste m is e xp eri enci ng e xces sive per iod s of hi gh or lo w volt age , ha ve a c ert ified electrician check your facility for electrical problems. If the problem continues, contact the util[...]
-
Página 8
990 -1137, 3 /02 6 Battery Charge The five-LED display on the right of the f ront panel shows the presen t charge of the UPS battery as a percentage of the battery capacity. When all five LEDs are lit, the battery is fully charged. The LEDs extinguish, from top to bottom, as the battery capacity dim inishes. Refer to the figu re at left for the bat[...]
-
Página 9
7 990 -1137, 3/02 B ASIC C ONNE CTORS Computer Inter- face Port Power management sof tware and interface kits can be used wi th the UPS. Use only interface kits supplied or approved by APC. Use the APC supplied cable to connect to the Computer Interface Port. DO NOT use a standard serial interface cable since it is incomp atible with the UPS connec[...]
-
Página 10
990 -1137, 3 /02 8 U SER C ONFIGURABLE I TEMS N OTE : S ETTING THESE ITEMS REQUIRES SOFT WARE , OPTION AL HARDWARE , OR CONFIGURATION IN T ERMIN AL M ODE . F UNCTION F ACTORY D EFAULT U SER S ELECTABLE C HOICES D ESCRIPTION Automa tic Self - Test Every 14 day s (336 hour s) Every 7 day s (168 hour s), On Startup Only, No Self-T est This func tion s[...]
-
Página 11
9 990 -1137, 3/02 N OTE : S ETTING THESE ITEMS REQUIRES SOFT WARE , OPTION AL HARDWARE , OR CONFIGURATION IN T ERMIN AL M ODE . F UNCTION F ACTORY D EFAULT U SER S ELECTABLE C HOICES D ESCRIPTION Output Fre quenc y Autom atic 50 ± 3 Hz , 50 ± 0. 1 Hz, 60 ± 3 H z, 60 ± 0. 1 Hz Sets the allow able output f requen cy of the UPS. When ever possibl [...]
-
Página 12
990-1 137 , 3/0 2 10 4: T RA NS POR T , M AINTENANCE , AND T R OUBLE SHOOT ING T RANSPORTING YOUR UPS Always DISCONNEC T THE B ATTERY befo re shipping in compliance with U.S. Departm ent of Transp ortation (DOT) regu lations . This require ment applies w hether the UPS is shi pped a lone or insta lled in an equipment rack or system. Follow these st[...]
-
Página 13
11 990- 11 37, 3/0 2 T ROUBLESHOOTING Use the chart belo w to solve minor UPS installation pro blems. Refer to the APC web site www.apc.com for assistan ce with complex UPS problems. P ROBLEM AND P OSSIBLE C AUSE S OLUTION UPS WILL NOT TURN ON ON bu tto n not pushe d. Pre ss the ON b utto n once to pow er the UP S and t he equi pment . UPS not co n[...]
-
Página 14
990-1 137 , 3/0 2 12 S ERVICE 1. Revi ew the problem s discuss ed in the Tr oubleshoot ing secti on of this m anual to eliminate com- mon probl ems . 2. Verify that no circuit break ers are tripped. A tripped circu it breaker is th e most common prob- lem. 3. If th e problem persi sts, call APC Cu stomer Servi ce or visi t the APC webs ite (www.apc[...]
-
Página 15
13 990- 11 37, 3/0 2 5: C ONT A CT , R EGULA TOR Y , A ND W AR R AN T Y I NFOR MA TION C ONTACTING AP C Refer to the information pro vided at the APC Internet site: http:/ /www.apc.com/support R EGULATORY A GENCY A PPROVALS N 3 94 B ME 61 D ECLARATION OF C ONFO RMITY geprü fte Sicher he it[...]
-
Página 16
990-1 137 , 3/0 2 14 L IMITED W ARRA NTY American Power Conv ersion (APC) warran ts its products to be free from defects in materials and workmansh ip for a period of two years from th e date of pu rchase. Its obligation un der this w arranty is limited to repairing or replacing, at its o wn sole option, any such defective products. T o obtain serv[...]