METRObility Optical Systems RADIANCE 10/100MBPS ACCESS OPTICAL NETWORK UNIT инструкция обслуживания
- Просмотреть online или скачать инструкцию
- 24 страниц
- 0.13 mb
Идти на страницу of
Похожие руководства по эксплуатации
-
Switch
METRObility Optical Systems R125-34
16 страниц 0.22 mb -
Switch
METRObility Optical Systems 8100
74 страниц 1.71 mb -
Switch
METRObility Optical Systems RADIANCE 10/100MBPS ACCESS OPTICAL NETWORK UNIT
24 страниц 0.13 mb -
Switch
METRObility Optical Systems R104-11
16 страниц 0.46 mb -
Switch
METRObility Optical Systems Radiance Sonet Single Interface Line Cards R125-34
16 страниц 0.23 mb -
Switch
METRObility Optical Systems 3508-11
20 страниц 0.14 mb -
Switch
METRObility Optical Systems 8124-01-M
132 страниц 1.76 mb -
Switch
METRObility Optical Systems RADIANCE 10/100PS ACCESS OPTICAL NETWORK UNIT
24 страниц 0.14 mb
Хорошее руководство по эксплуатации
Законодательство обязывает продавца передать покупателю, вместе с товаром, руководство по эксплуатации METRObility Optical Systems RADIANCE 10/100MBPS ACCESS OPTICAL NETWORK UNIT. Отсутствие инструкции либо неправильная информация, переданная потребителю, составляют основание для рекламации в связи с несоответствием устройства с договором. В законодательстве допускается предоставлении руководства в другой, чем бумажная форме, что, в последнее время, часто используется, предоставляя графическую или электронную форму инструкции METRObility Optical Systems RADIANCE 10/100MBPS ACCESS OPTICAL NETWORK UNIT или обучающее видео для пользователей. Условием остается четкая и понятная форма.
Что такое руководство?
Слово происходит от латинского "instructio", тоесть привести в порядок. Следовательно в инструкции METRObility Optical Systems RADIANCE 10/100MBPS ACCESS OPTICAL NETWORK UNIT можно найти описание этапов поведения. Цель инструкции заключается в облегчении запуска, использования оборудования либо выполнения определенной деятельности. Инструкция является набором информации о предмете/услуге, подсказкой.
К сожалению немного пользователей находит время для чтения инструкций METRObility Optical Systems RADIANCE 10/100MBPS ACCESS OPTICAL NETWORK UNIT, и хорошая инструкция позволяет не только узнать ряд дополнительных функций приобретенного устройства, но и позволяет избежать возникновения большинства поломок.
Из чего должно состоять идеальное руководство по эксплуатации?
Прежде всего в инструкции METRObility Optical Systems RADIANCE 10/100MBPS ACCESS OPTICAL NETWORK UNIT должна находится:
- информация относительно технических данных устройства METRObility Optical Systems RADIANCE 10/100MBPS ACCESS OPTICAL NETWORK UNIT
- название производителя и год производства оборудования METRObility Optical Systems RADIANCE 10/100MBPS ACCESS OPTICAL NETWORK UNIT
- правила обслуживания, настройки и ухода за оборудованием METRObility Optical Systems RADIANCE 10/100MBPS ACCESS OPTICAL NETWORK UNIT
- знаки безопасности и сертификаты, подтверждающие соответствие стандартам
Почему мы не читаем инструкций?
Как правило из-за нехватки времени и уверенности в отдельных функциональностях приобретенных устройств. К сожалению само подсоединение и запуск METRObility Optical Systems RADIANCE 10/100MBPS ACCESS OPTICAL NETWORK UNIT это слишком мало. Инструкция заключает ряд отдельных указаний, касающихся функциональности, принципов безопасности, способов ухода (даже то, какие средства стоит использовать), возможных поломок METRObility Optical Systems RADIANCE 10/100MBPS ACCESS OPTICAL NETWORK UNIT и способов решения проблем, возникающих во время использования. И наконец то, в инструкции можно найти адресные данные сайта METRObility Optical Systems, в случае отсутствия эффективности предлагаемых решений. Сейчас очень большой популярностью пользуются инструкции в форме интересных анимаций или видео материалов, которое лучше, чем брошюра воспринимаются пользователем. Такой вид инструкции позволяет пользователю просмотреть весь фильм, не пропуская спецификацию и сложные технические описания METRObility Optical Systems RADIANCE 10/100MBPS ACCESS OPTICAL NETWORK UNIT, как это часто бывает в случае бумажной версии.
Почему стоит читать инструкции?
Прежде всего здесь мы найдем ответы касательно конструкции, возможностей устройства METRObility Optical Systems RADIANCE 10/100MBPS ACCESS OPTICAL NETWORK UNIT, использования отдельных аксессуаров и ряд информации, позволяющей вполне использовать все функции и упрощения.
После удачной покупки оборудования/устройства стоит посвятить несколько минут для ознакомления с каждой частью инструкции METRObility Optical Systems RADIANCE 10/100MBPS ACCESS OPTICAL NETWORK UNIT. Сейчас их старательно готовят или переводят, чтобы они были не только понятными для пользователя, но и чтобы выполняли свою основную информационно-поддерживающую функцию.
Содержание руководства
-
Страница 1
Installation & User Guide Models: RA21-13 / RA21-14 / RA21-15 / RA21-16 / RA21-17 / RA21-1J / RA21-1X / RA21-1Y R ADIANCE 10/100M BPS A CCESS O PTICAL N ETWORK U NIT TM ACT LK ACT 100 BASE FX LK DIS Radiance RA21 LBK DIS II x PWR MAN FD 100 TM ACT LK ACT 100 BASE FX LK DIS Radiance RA21 LBK DIS II x PWR MAN FD 100 TM ACT ACT Radiance RA21 LBK L[...]
-
Страница 2
This publication is protected by the copyright laws of the United States and other countries, with all rights reserved. No part of this publication may be reproduced, stored in a retrieval system, translated, transcribed, or transmitted, in any form, or by any means manual, electric, electronic, electromagnetic, mechanical, chemical, optical or oth[...]
-
Страница 3
T able of Contents Radiance 10/100Mbps Access Optical Network Unit Installation & User Guide Overview .............................................................................................................. 4 Installation Guide ............................................................................................... 6 STEP 1: Unpack[...]
-
Страница 4
4 Overview Overview The Metrobility Radiance 10/100Mbps Access Optical Network Unit (ONU) offers the benefits of remote management while eliminating the expenses associated an additional chassis and management card at the remote site. The compact Access ONU is a complete standalone device designed for installation at the customer premise, with no a[...]
-
Страница 5
Radiance 10/100Mbps Access Optical Network Unit 5 the sender . FEF enables the Access Line Card in the central office to detect a break in the Access ONU’ s fiber port receiver . The combination of these operations, along with the unit’ s remote management feature, enable easy deployment of Ethernet services to customers. The Radiance Access ON[...]
-
Страница 6
6 Installation Guide Installation Guide 2 A device that is wired straight through needs one crossover connection: If the cable is straight through crossover the MDI-II to MDI-X switch setting should be X II A device that is wired crossover needs a parallel connection: If the cable is straight through crossover the MDI-II to MDI-X switch setting sho[...]
-
Страница 7
Radiance 10/100Mbps Access Optical Network Unit 7 * DIP switches can also be managed remotely via console commands or through Metrobility’s NetBeacon or W ebBeacon management software. Refer to the Command Line Interface Reference Guide , NetBeacon Element Management Software Installation & User Guide or W ebBeacon Management Software Install[...]
-
Страница 8
8 Installation Guide Duplex The DUPLEX switch sets the duplex mode on the copper port when auto-negotiation is disabled. The copper port operates at full duplex when DUPLEX is ON. It operates at half duplex when DUPLEX is OFF . When auto-negotiation is enabled, the DUPLEX switch setting is ignored. Auto-Negotiation Auto-negotiation is supported onl[...]
-
Страница 9
Radiance 10/100Mbps Access Optical Network Unit 9 3 Link Loss Carry Forward Link Loss Carry Forward (LLCF) is provided as an aid in troubleshoot- ing a remote connection. When LLCF is enabled, loss of the receive signal at the copper port prevents the fiber port from transmitting an idle signal onto the cable. Conversely , if the fiber port does no[...]
-
Страница 10
10 Installation Guide TM ACT LK ACT TX RX LK DIS Radiance RA21 LBK DIS II x PWR MAN FD 100 T wisted-Pair Interface The copper port provides a shielded RJ-45 connector that supports a maximum segment length of 100 meters. Use only Category 5 cables. Fiber Optic Interface The unit’ s fiber receiver (RX) is to the right of the transmitter (TX). When[...]
-
Страница 11
Radiance 10/100Mbps Access Optical Network Unit 11 4 mentary pairs. That is, a -1X model must always be connected to a -1Y . The -1X units are designed to transmit data at a wavelength of 1550nm and receive at 1310nm. Correspondingly , the -1Y units transmit data at 1310nm and receive at 1550nm. Apply Power Power is provided through the desktop pow[...]
-
Страница 12
12 Installation Guide three-conductor cord, a maximum of 15 feet in length and a parallel blade, grounding-type attachment plug rated 15A, 125V . • AC 230V (USA): use a UL-listed cord set consisting of a minimum No. 18 A WG, type SVT three-conductor cord, a maximum of 15 feet in length and a T andem blade grounding- type attachment plug rated 15A[...]
-
Страница 13
Radiance 10/100Mbps Access Optical Network Unit 13 User Guide This section contains information about the operating features of the Radiance 10/100Mbps Access Optical Network Unit. LED Indicators The Radiance Access Optical Network Unit provides several LEDs on the front panel for the visible verification of unit status and proper functionality . T[...]
-
Страница 14
14 User Guide Far End Fault ................................................................................... Enabled (ON) Link Loss Return .......................................................................... Disabled (OFF) Link Loss Carry Forward ............................................................. Disabled (OFF) Default Software [...]
-
Страница 15
Radiance 10/100Mbps Access Optical Network Unit 15 Disabling a port stops the data flow to and from that port. Although data is neither sent nor received, the disabled port continues to accept, process and transmit management packets. However , if LLCF is enabled and the opposite port has no link, management packets will not be transmitted. Remote [...]
-
Страница 16
16 User Guide Singlemode Fiber Optic Power Monitors Through software * , you can read the input and output power levels of the singlemode fiber optic port on the Access ONU. Input Power Level The accuracy of the input power monitor is ± 1dBm from -28dBm to -12dBm. The accuracy is ± 2dBm from -31dBm to -29dBm. The monitor is unresponsive below -31[...]
-
Страница 17
Radiance 10/100Mbps Access Optical Network Unit 17 Link Loss Carry Forward (LLCF) * The Access Optical Network Unit incorporates Link Loss Carry Forward as an aid in troubleshooting a remote connection. When LLCF is enabled, the ports do not transmit a link signal until they receive a link signal from the opposite port. W arning: If LLCF is enabled[...]
-
Страница 18
18 User Guide Link Loss Return (LLR) The fiber optic port of the Access ONU has been designed with Link Loss Return functionality * for troubleshooting a remote connection. When LLR is enabled, the fiber port’ s transmitter shuts down if its receiver fails to detect a valid receive link. LLR should only be enabled on one end of the link and is ty[...]
-
Страница 19
Radiance 10/100Mbps Access Optical Network Unit 19 T opology Solutions Radiance R5000 Radiance Acces Optical Network Unit Customer Premises CO/POP SNMP Control Remote Communications Path Status Reporting Configuration Instructions Used Bandwidth = 0[...]
-
Страница 20
20 User Guide T echnical Specifications Data Rate Data Rate ________ 100Mbps half duplex, 200Mbps full duplex (Fast Ethernet) ______________ 10Mbps half duplex, 20Mbps full duplex (Ethernet) Network Connections T wisted-Pair Interface Connector __________________________________ Shielded RJ-45, 8-pin jack Impedance _________________________________[...]
-
Страница 21
Radiance 10/100Mbps Access Optical Network Unit 21 Singlemode F/O Interface — extended long haul distance support (RA21-1J) Connector _____________________________________________________ SC W avelength _______________________________________________ 1550 nm RX Input Sensitivity ________________________________ -34 dBm minimum Output Power ______[...]
-
Страница 22
22 User Guide Product Safety , EMC and Compliance Statements T his equipment complies with the following requirements: •U L• DOC Class B (emissions) • CSA • EN55022 Class B (emissions) •C E• EN55024: 1998 (immunity) • EN60950 (safety) • IEC 825-1 Classification • FCC Part 15, Class B • Class 1 Laser Product This product shall be[...]
-
Страница 23
Radiance 10/100Mbps Access Optical Network Unit 23 W arranty and Servicing Three-Y ear W arranty for the Radiance Access Optical Network Unit Metrobility Optical Systems, Inc. warrants that every Radiance Access Optical Unit will be free from defects in material and workmanship for a period of THREE YEARS from the date of Metrobility shipment. This[...]
-
Страница 24
Product Manuals The most recent version of this manual is available online at http://www .metrobility .com/support/manuals.htm To obtain additional copies of this manual, contact your reseller, or call 1.877.526.2278 or 1.603.880.1833 Product Registration To register your product, go to http://www .metrobility .com/support/registration.asp 25 Manch[...]