AT&T 555-230-894 Bedienungsanleitung

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332

Zur Seite of

Richtige Gebrauchsanleitung

Die Vorschriften verpflichten den Verkäufer zur Übertragung der Gebrauchsanleitung AT&T 555-230-894 an den Erwerber, zusammen mit der Ware. Eine fehlende Anleitung oder falsche Informationen, die dem Verbraucher übertragen werden, bilden eine Grundlage für eine Reklamation aufgrund Unstimmigkeit des Geräts mit dem Vertrag. Rechtsmäßig lässt man das Anfügen einer Gebrauchsanleitung in anderer Form als Papierform zu, was letztens sehr oft genutzt wird, indem man eine grafische oder elektronische Anleitung von AT&T 555-230-894, sowie Anleitungsvideos für Nutzer beifügt. Die Bedingung ist, dass ihre Form leserlich und verständlich ist.

Was ist eine Gebrauchsanleitung?

Das Wort kommt vom lateinischen „instructio”, d.h. ordnen. Demnach kann man in der Anleitung AT&T 555-230-894 die Beschreibung der Etappen der Vorgehensweisen finden. Das Ziel der Anleitung ist die Belehrung, Vereinfachung des Starts, der Nutzung des Geräts oder auch der Ausführung bestimmter Tätigkeiten. Die Anleitung ist eine Sammlung von Informationen über ein Gegenstand/eine Dienstleistung, ein Hinweis.

Leider widmen nicht viele Nutzer ihre Zeit der Gebrauchsanleitung AT&T 555-230-894. Eine gute Gebrauchsanleitung erlaubt nicht nur eine Reihe zusätzlicher Funktionen des gekauften Geräts kennenzulernen, sondern hilft dabei viele Fehler zu vermeiden.

Was sollte also eine ideale Gebrauchsanleitung beinhalten?

Die Gebrauchsanleitung AT&T 555-230-894 sollte vor allem folgendes enthalten:
- Informationen über technische Daten des Geräts AT&T 555-230-894
- Den Namen des Produzenten und das Produktionsjahr des Geräts AT&T 555-230-894
- Grundsätze der Bedienung, Regulierung und Wartung des Geräts AT&T 555-230-894
- Sicherheitszeichen und Zertifikate, die die Übereinstimmung mit entsprechenden Normen bestätigen

Warum lesen wir keine Gebrauchsanleitungen?

Der Grund dafür ist die fehlende Zeit und die Sicherheit, was die bestimmten Funktionen der gekauften Geräte angeht. Leider ist das Anschließen und Starten von AT&T 555-230-894 zu wenig. Eine Anleitung beinhaltet eine Reihe von Hinweisen bezüglich bestimmter Funktionen, Sicherheitsgrundsätze, Wartungsarten (sogar das, welche Mittel man benutzen sollte), eventueller Fehler von AT&T 555-230-894 und Lösungsarten für Probleme, die während der Nutzung auftreten könnten. Immerhin kann man in der Gebrauchsanleitung die Kontaktnummer zum Service AT&T finden, wenn die vorgeschlagenen Lösungen nicht wirksam sind. Aktuell erfreuen sich Anleitungen in Form von interessanten Animationen oder Videoanleitungen an Popularität, die den Nutzer besser ansprechen als eine Broschüre. Diese Art von Anleitung gibt garantiert, dass der Nutzer sich das ganze Video anschaut, ohne die spezifizierten und komplizierten technischen Beschreibungen von AT&T 555-230-894 zu überspringen, wie es bei der Papierform passiert.

Warum sollte man Gebrauchsanleitungen lesen?

In der Gebrauchsanleitung finden wir vor allem die Antwort über den Bau sowie die Möglichkeiten des Geräts AT&T 555-230-894, über die Nutzung bestimmter Accessoires und eine Reihe von Informationen, die erlauben, jegliche Funktionen und Bequemlichkeiten zu nutzen.

Nach dem gelungenen Kauf des Geräts, sollte man einige Zeit für das Kennenlernen jedes Teils der Anleitung von AT&T 555-230-894 widmen. Aktuell sind sie genau vorbereitet oder übersetzt, damit sie nicht nur verständlich für die Nutzer sind, aber auch ihre grundliegende Hilfs-Informations-Funktion erfüllen.

Inhaltsverzeichnis der Gebrauchsanleitungen

  • Seite 1

    555 -230 -894 Issue 1 Septem ber , 1995 DE FINITY ® Communications Sy stem G ene ric 3 Ins talla ti on (For Si ngle-Carri er Cabi nets) Graphics © AT& T 1988 Table of Contents[...]

  • Seite 2

    Blank Pag e[...]

  • Seite 3

    Conten ts Issue 1 S ep t em ber 1995 iii Tabl e of Co nten ts i About Thi s Book xv ■ This B ook’s O rganiz ati on xv ■ Other Boo ks xvi ■ Trademarks xvii 1 Ov ervi ew and Roadmap 1-1 ■ Syste m R eliabi lity 1-1 S tandard R elia bility 1-2 Hig h R eliab ility 1 -2 Crit ical Reliabil i ty 1- 2 ■ DEFI N I TY Syst e m I nstal lati on R oa [...]

  • Seite 4

    Conten ts iv Issue 1 S ep t em ber 1995 Generic 3 Managem ent T e rminal (G3-MT) R equirements 2-2 Cross-Connect Field s 2-2 Space R equi reme nts 2-2 R oom Layout 2-2 F igure Note s : 2-3 C a ble Slac k M anager (Opt ional) R equi rements 2-4 Tool s Neede d 2-4 Lay Out an d Ensure A p p ro priat e Power 2-6 P ower A rrangeme nts for AC P ower 2-6 [...]

  • Seite 5

    Conten ts Issue 1 Sep t em ber 1995 v F i gure Notes: 4-11 Connect Sing le-Carrier Network Grou nding 4-11 F i gure Notes: 4-12 Coupled Bo n ding Conduc tor (CBC) 4-12 F i gure Notes: 4-13 Connect D C P o wer to Netwo r ks 4-14 Connect AC Power t o DC Po wer Ca binet 4-14 T est DC Power Plant 4-14 Connect S t a n d -by Power 4-14 ■ Locate and Con[...]

  • Seite 6

    Conten ts vi Issue 1 S ep t em ber 1995 Instal l F ront P l ates on Syste ms with E arthq uake Prot ec t i on 4-35 Instal l Ca binet Clip On S ystem s wi thout E arthq uake Prot e c t io n 4-35 F i gure Notes: 4-36 5 Instal l T el ecommun icati ons Cabl ing 5-1 ■ Install t he C ro s s-Connect Fi eld 5-1 Typi cal Cross-Connect Field Using 110- T y[...]

  • Seite 7

    Conten ts Issue 1 S e p t e m ber 1995 vii P ower up AC - Powered S witch 7-3 P ower up DC- P owered Swi tc h 7-3 V erify Mess ag es on T ermina l 7-3 ■ I n troductio n to Term inal Screens and Com man d s 7-4 Screens 7-4 Co mmands 7- 5 Ge t t in g Hel p 7-5 ■ Log i n to the Syste m 7-5 ■ S e t Re quired Co u ntry O p t ions 7-6 ■ Change Cr[...]

  • Seite 8

    Conten ts vi ii Is sue 1 Se ptemb er 1995 ■ R e -instal l F ro nt Doors 8-20 ■ Next S t eps 8-20 9 Instal l and W i re Teleph ones and Other Equ ipmen t 9-1 ■ Telephone Conn ecti on Exam ple 9- 1 Connect Adj unct Power 9-3 ■ Analog St a t ion or 2 - W ire Digita l St at ion Examp le 9 -5 ■ Analog T ie Trunk Exam p le 9 - 6 ■ Digita l T [...]

  • Seite 9

    Conten ts Is s ue 1 Sep temb er 199 5 ix F i gure Notes: 9-32 R eset L i g ht E mi tti n g Dio des (L ED) on P ower Distri b u t ion Unit 9-33 ■ Inst all t he M S P-1 Power S up p l y 9-34 U n derwrite r’s L ab oratories (UL) Inform at ion 9-34 Im portan t S a fety Instructions 9-35 Descript io n of th e MS P- 1 P ower Supp l y 9-36 Locat e the[...]

  • Seite 10

    Conten ts x Issue 1 Sep t em ber 1995 Instal l Fe deral Co mmunicati ons C omm ission (FCC) R e gistered Music Source 9-54 Instal l R e c ord ed A nnoun c e m ent E quipm e n t 9-54 R e quirem ents 9-54 F i gure Notes: 9-55 ■ Install Proc e s so r Data M od ules (PDM s) 9-55 R e quirem ents 9-55 Insta llation 9-56 F i gure Notes: 9-57 Connect ion[...]

  • Seite 11

    Conten ts Is s ue 1 Sep temb er 199 5 xi De s c rip tion 10-3 P rocedur e 10-3 ■ Make Test Ca lls (Thre e-Cabi net S witch) 10-4 De s c rip tion 10-4 P rocedur e 10-5 ■ Test t h e A t ten dant Console 10-8 Descript ion 10-8 Proc edure 10-8 ■ Test t he S elec tor Console 10-9 Descript ion 10-9 Proc edure 10-9 ■ Test Ext ernal Rin g ing 10-9 [...]

  • Seite 12

    Conten ts xi i Issue 1 Sep te m ber 1995 Proc edure—Local Test 10-15 ■ Test Basic R ate I n terf ace ( B RI) 10-15 Descript ion 10-15 Proc edure— Dial Tone 10-15 Proc edure—M ake and R eceive Calls 10-15 Proc edure—Check ing t he S ervice Prof il e Identif ier (SPI D ) 10-16 A Approved G rou nds A- 1 ■ Defi nit ion of Ap p roved Groun d[...]

  • Seite 13

    Conten ts Issue 1 Sep t em ber 1995 xiii Dist ance Limita tions E - 4 F igure Note s : E - 5 F igure Note s : E - 5 ■ W all Mount ing E - 6 ■ Using the T est Feat ure E- 9 The Test Fea t u re E-9 ■ B ut to n Label s E-10 F Wire Conversion Inform at ion F-1 ■ Common Wire Colo u rs F-1 ■ A WG to S WG Co nv e r s ion ( S tranded W ire) F-1 ?[...]

  • Seite 14

    Conten ts xi v Issue 1 S ep t e m b er 1995 ■ 475 Print e r U se d as Sys t e m P rint er H-21 ■ 475 or 476 P rinte r Used as Journal P r int er for Hospi tal ity F e a ture H-21 ■ 470 or 471 P rinte r Used as Journal P r int er for Hospi tal ity F e a ture H-28 ■ 572 Print er H-30 ■ S t atio n Message Det ail Rec o rd ing ( S MD R ) In t[...]

  • Seite 15

    Issue 1 Septemb er 1995 xv About This Boo k This book supp orts DEFI N I T Y ® Co mmunica t i ons S yst em s G eneric 3 Version 3 and la ter. T his book provides proce dures and in format ion for inst allin g the hardwar e and init iall y testin g the D E FINI T Y Co m m unica t i on s Sy s tem Generic 3, Models G3 i a nd G3s. The inform at ion in[...]

  • Seite 16

    A bout This Bo ok xv i Issue 1 S ep t e m b er 1995 ■ Chap ter 5, " Inst all Tel ecommunicat ions Cabling" Explains how t o instal l cabl ing b et ween th e sw itch a nd t he cross-c onnect f ield. ■ Chap ter 6, " Inst all G e neric 3 Manag em ent Ter minal " Explains h ow to i nstall an d b ring u p the Generic 3 Ma nage me[...]

  • Seite 17

    Trademarks Is s ue 1 Sep temb e r 199 5 xvii This c a t alog and al l DEFI N I TY C o m m u nicat ions Syste m Ge n eric 3 docum en t a ti o n i n Un ite d St a te s E ng lish can be order e d directly from: General Busin ess Com munication s Syst em P ublicati ons F ulfillm ent Centre at 1-317-361-5353. Tra d emarks This book cont ains refere nces[...]

  • Seite 18

    A bout This Bo ok xv iii Is sue 1 September 1995[...]

  • Seite 19

    Issue 1 S e p tem ber 1995 1-1 1 Overview and Roadmap This chap ter presents g eneral in form at ion about t h e methods t o config ure your DEFI N I TY Syste m Ge n eric 3 for s y stem avail ability . I t also provides a roadma p ( a hig h-level overview of the se q uence o f st e ps ) for the install ation of the system. T he road m a p provides [...]

  • Seite 20

    Overview a n d R o a d ma p 1-2 Is sue 1 Se ptemb er 1995 Stan d a rd Reliab il ity DEFI N I TY System G3 st a ndard reliab ility systems p rovide the most c ost- effe c tive product . This is t he only reliabilit y o ffering for a G3s system. S tan dard reliabilit y s yst ems do not d u p licat e Tone-Cloc k (s), the Control Carriers, or an y int [...]

  • Seite 21

    DEFI N I TY Syste m In st a ll ati on Road m a p Issue 1 Sep te m b er 1995 1-3 DEFIN ITY Sy stem Instal l ation Road map This sectio n i s intende d to p rovide a hig h-level sequence for th e i nstal lat ion proces s and also a roadma p to the infor m ati on in thi s b o ok. It is also note d where specific s t eps are cov er ed in othe r b o oks[...]

  • Seite 22

    Overview a n d R o a d ma p 1-4 Is sue 1 Se ptemb er 1995 4. Connect batter y leads. 5. Connect AC p ower or DC power . 6. Locate and connect T i m e Division M ul ti p lexer (TDM) Bus. 7. Locate a nd co nnect i n ter-cabinet cabl es, if system has d u pl icate d Swit ch Processor E l emen ts (S P E s) in Proce ssor P ort Netwo rk ( P P N ) c o ntr[...]

  • Seite 23

    DEFI N I TY Syste m In st a ll ati on Road m a p Issue 1 Sep te m b er 1995 1-5 Activ ate th e S ystem Complete thi s task by f ollowing the instructions provided i n Chapt er 7. 1. Powe r u p switc h. 2. Log in to the sy stem. 3 . S e t required c ountry op t ion s. 4. Change c r aft password. 5 . S e t date and t im e . 6. S e t syst em maint ena[...]

  • Seite 24

    Overview a n d R o a d ma p 1-6 Is sue 1 Se ptemb er 1995 Install an d Wire Teleph ones an d Oth er Equipment Complete thi s task by f ollowing the instructions provided i n Chapt er 9. NO TE: For easier r e feren ce, inst allation st eps and t est steps are group e d i n separate chap ters. I t may b e b e tter to insta ll each hardware comp onent[...]

  • Seite 25

    DEFI N I TY Syste m In st a ll ati on Road m a p Issue 1 Sep te m b er 1995 1-7 Adm in is ter the D EFIN I T Y Syst em Ac cord in g to Custo mer Req uir emen ts Af ter the hardwar e is inst alled and the system is activat e d , the d ata for system and telep hone features m ust b e a d m in istered, using the provisioning p lan created for this c u[...]

  • Seite 26

    Overview a n d R o a d ma p 1-8 Is sue 1 Se ptemb er 1995[...]

  • Seite 27

    Issue 1 S e p tem ber 1995 2-1 2 Plan and Prepare the S ite This chap ter describe s t asks required to p lan, prep are, a n d p ro vision the site d e pe n ding u pon which DEFI N I TY Syste m G e neric 3 was ordered. P erform the following : ■ Check th e custom er’s ord er. ■ Locate and lay out the equip men t ro om . ■ Lay out a n d en s[...]

  • Seite 28

    P lan and Prep are the Si t e 2-2 Is sue 1 Se ptemb er 1995 Locate an d Lay Ou t the Eq uip m ent Roo m Determin e where t he DEFI N I TY Syst em G e neric 3 e quipm ent room is lo cated , and t hen lay out the e quipm ent room floo r p l an for DEFI N I TY Syst em c a b inet s, managemen t term inal and desk, cross-connect hardware and adjuncts, e[...]

  • Seite 29

    Locate and Lay Out the Eq u i p men t R oom Issue 1 Sep te m b er 1995 2-3 Add ition al N otes: AC re c e p t a c les m ust be sep arate l y cu rre nt p r o te c te d (f use or c ir c u it brea ker) and n ot u nd e r t he c o nt rol of a wal l switc h . Rec e p t a c les must not be shar e d with other eq u i p ment a n d s h ou ld b e loc at ed a [...]

  • Seite 30

    P lan and Prep are the Si t e 2-4 Is sue 1 Se ptemb er 1995 Cab le Slac k M anager (O ption al ) Req u irem e nts A c a ble slack manager (opt ional ) is 32 i nches (81 cm) wide and 40 inches (102 c m) deep. N ormally, one slack m anager is needed for each c abinet sta ck. Extra slack managers may b e order ed, i f necessary. Tools Ne eded Table 2-[...]

  • Seite 31

    Locate and Lay Out the Eq u i p men t R oom Issue 1 Sep te m b er 1995 2-5 * Electric d r i ll and dril l bi ts are required for ea rthqua ke mo un ting. † Since U .S. / E ngli sh fasten e rs a re u sed, U.S . /E ngli s h tools are required unless an exact match can b e found among metric t oo ls. ‡ Req uired when installing an AC p o were d sw[...]

  • Seite 32

    P lan and Prep are the Si t e 2-6 Is sue 1 Se ptemb er 1995 Lay O ut an d Ensur e A p pr opriate P ow er 1. Lay o ut an d en s u re a p prop riate p ower for s w itch cabinet s and managemen t term inal in e qu ip ment room . 2. Provid e on e power outle t per single-carrier c a b inet . 3. Have an e lect rician ch e ck the commerci al power an d v[...]

  • Seite 33

    Locate and Lay Out the Eq u i p men t R oom Issue 1 Sep te m b er 1995 2-7 Power Arrangem ents for DC Po we r The fo llowin g t a b le shows the in p ut DC requireme nts for the system -48 V DC I np ut Power R e q uirement s Parameter R e quirem ents S ta ti c V ol ta g e -4 8 VDC no mi nal, - 4 2.5 VDC m inim um, -52.5 VDC maxim um ( measured at i[...]

  • Seite 34

    P lan and Prep are the Si t e 2-8 Is sue 1 Se ptemb er 1995 Lay Ou t and En sure Appro priate Grou nding Groundin g is relat ively sim ple for an AC-power e d switch . First, connect th e cabin e ts t o e ac h othe r . Then, c onnect a singl e groun d wire from the Proce ssor Port Ne twork (PPN) to t he a p p roved protec tive ground. Groundin g o [...]

  • Seite 35

    Determin e the Locatio n o f the Equi pm en t Closet s Issue 1 Sep te m b er 1995 2-9 NO TE: Check locati on of the AC p ower receptacle. The receptacl e must b e on a separa tely current limit ed ( fuse or ci rcuit breaker) cir c uit n ot controlled by a wall switc h . Det ermine t he L ocation of t he Equ i pme n t Cl osets Determin e the locat i[...]

  • Seite 36

    P lan and Prep are the Si t e 2-10 Issue 1 S e pt em ber 1995 . Tabl e 2- 2 . Exam ple of a P rovision ing Plan Station or Trun k Type or Feature/Service Building Location (f loo r/ro om/ desk/ infor mation outlet Extensio n Number or Trunk Group and Member DEFINITY G3 cabi net/ car r ier/s lot/ circuit Ro ute from equipment closets Auxi liar y Pow[...]

  • Seite 37

    S eptember 1995 Is s ue 1 3-1 3 Unpack the Cab i ne t This chap ter describ e s t h e sy s t e m unpacki ng proced ures. The DEFI N I TY Syst em Ge n eric 3 ( G3) single-carrier c a b inet s are ship pe d i n a p o l yethyle n e b a g , p acked in a cardboard conta i ner. The cabi net i s faste ned to a wood/ S tyrof oam p allet with two met al b a[...]

  • Seite 38

    Unpack the Cabine t 3-2 S ep tember 1995 Issue 1 ! CAUTION: Deep knife pene trat ion m a y d ama g e the c a binet. 4. O p en an d rem o ve the front door a nd b ack p anels from cabin e t . The screw locat ion is shown in the followi n g fi gures. Figu re No tes: 1. Sc rew that op e ns front c a b inet d oo r Figure 3-1. Front C abinet Door Latch [...]

  • Seite 39

    S e p t e m b er 1995 Issue 1 3-3 Figu re No tes: 1. Sc rews to re move 2. Sc rews to loo s en 3. Sc rews to rem a in Figure 3-2. Back Cabinet P ane l S crew L ocations 1 . R e m ov e a ll packing ma t erial fro m inside th e ca b inet. Inspect Cab inet 2 . Inspect c a b inet for any d am age that may have occurred d uring sh ip ping. R eport a ny [...]

  • Seite 40

    Unpack the Cabine t 3-4 S ep tember 1995 Issue 1 3. Verif y t he l a be l near the circ uit b reaker on the p ower suppl y t oward th e rear of each c a b inet c o rresp o n d s to your local v o ltage type. ! DANGER: If the l a b el i s d ifferen t than the volt age typ e a t your site, notif y you r A T & T re present a tive i mme diat ely fo[...]

  • Seite 41

    Issue 1 S e p tem ber 1995 4-1 4 Install and Connect t h e Cabinets This chap ter describe s h o w to install the P rocessor Port Net work (PP N) an d Expansion Port Ne twork ( E PN) sing le-carrier cabin e t s f o r D E F I N I T Y Sys t e m Generic 3 . Direct ions are provided for th e foll owing c onfig urat ions: ■ S t an dard reliab ility ?[...]

  • Seite 42

    Install a n d Co nnect th e Cab inet s 4-2 Is sue 1 Se ptemb er 1995 Instal l Earthq uake Mo u n ting I f earthq uake protec t ion is re q uired f o r your area, install earthq uake floor mounti ng as d irect ed in Ap pendi x B. Positi on a n d S tack th e Cabi n ets Foll ow th e d i agram in the Custo mer Service Document (CSD) sh ip p e d with e [...]

  • Seite 43

    Connect Syste m Cabin e t Gr ounds Issue 1 Sep te m b er 1995 4-3 Con nect Sy stem Cabi net G rounds T o connect ground, r e fe r to Figu re 4-2 on p a g e 4-4 an d perf orm t he foll owing: 1. At lower left rear of t h e P rocessor P ort Network (PPN) c abinet (Control Cabine t A) , connect a 6 AW G g round wire to the cabi n e t g round bl ock. S[...]

  • Seite 44

    Install a n d Co nnect th e Cab inet s 4-4 Is sue 1 Se ptemb er 1995 Figure 4 - 2. Typ ical AC P ower and G rounding A rrangemen t for Single-Carrier Cabinet ( Rear View) ON ON OFF OFF ON ON OFF OFF ON ON OFF OFF ON ON OFF OFF 8 13 9 5 10 6 11 7 7 7 7 12 12 1 1 3 4 2 1. Expa nsio n P ort Ne two r k (EPN) Con t ro l Cabi net A 2. Circuit bre aker 3.[...]

  • Seite 45

    Connect Bat t ery Lea ds Issue 1 Sep te m b er 1995 4-5 Con nec t B a ttery Lead s T o prevent the bat t eries f rom discharging, the c o n trol c a b inet i s shippe d wit h the b attery l ead d isc onnecte d. T o connect t h e bat t eries, perfo rm the follow ing: At cabin et ( s ): 1. Ensure th e c ircuit breakers on e ac h ca binet are OFF . Ea[...]

  • Seite 46

    Install a n d Co nnect th e Cab inet s 4-6 Is sue 1 Se ptemb er 1995 Con nec t Po wer Connect ei t her AC or DC p ower a s d esc rib e d in this section . Verif y t he l a bel near the circui t brea k er o n t he p ower suppl y t oward the r ear of each c a b inet cor r esp o nd s to your local v o ltage type. ! DANGER: I f th e label is di f f ere[...]

  • Seite 47

    Connect Powe r Issue 1 Sep te m b er 1995 4-7 GRD -4 8V -4 8V R TN 1 GRD -4 8V -4 8V R TN 1 GRD -4 8V -4 8V R TN 1 GRD -4 8V -4 8V R TN 1 -4 8V RTN -48V GRD 1 1 1 1 1 1 1 1 3 8 13 18 4 9 14 5 5 10 15 15 15 15 1 1 1 6 11 11 16 16 16 2 2 2 2 7 7 7 12 17 (- 48 V RTN & G RD) 75A -48V -48V GR D GR D -4 8V -48 V RTN 75A[...]

  • Seite 48

    Install a n d Co nnect th e Cab inet s 4-8 Is sue 1 Se ptemb er 1995 Figure 4-4. Typical S ingle-Carrier Cabinet System Direct Curren t (D C) Power and Groun ding W iring ! CAUTION: Groundin g o f the sys tem shal l c o m p ly with the g eneral rules for grounding contained in Article 250 of the Nat ional E lectrical Code (NEC), National F ire Prot[...]

  • Seite 49

    Connect Powe r Issue 1 Sep te m b er 1995 4-9 Connect Powe r Pl ant Gr ound T o connect t h e p ower p lant ground, complet e th e f o l lowing steps: 1. At th e DC power cabine t , connect a 1 AW G ground wire to the GR OUND DIS C H A RGE b a r . 2. R oute the g ro und wire o ut of th e c a binet and t erminate i t on the a pprov e d ground ( see [...]

  • Seite 50

    Install a n d Co nnect th e Cab inet s 4-10 Issue 1 S e pt em ber 1995 Co nn e c t Fr ame Gr ou nd Connect the 6 AW G f rame ground c a ble to the cabi net frame b y followin g t hese steps: 1. Measure an d cu t a length o f 6 AW G c a bl e . Use the p rovided cable or measure and cu t a l ength o f 6 AW G ca ble long enough to reach between the GR[...]

  • Seite 51

    Connect Powe r Issue 1 Septe m b er 1995 4-11 Conn ec t DC P ower D istrib ut ion Bo x Grou n d i n g R un the 6 A WG ground c a ble f rom t he DC P ower Cab inet to each DC Powe r Distrib u t ion Unit , using the f ollowi ng steps: 1. A t the DC P ower Ca b inet , c o n nect 6 AW G wire to the GR OUND D I SCHAR G E b ar . R o ut e the cable to th [...]

  • Seite 52

    Install a n d Co nnect th e Cab inet s 4-12 Issue 1 S e pt em ber 1995 1. A t the DC P ower Ca b inet , c o n nect a 6 A WG cable to th e G ROUND D I SCHAR G E b ar. R o ute the cable to th e po r t Cabine t Carrier A. Connect th e c a ble t o th e single-point ground block in th e C o ntrol Carrie r (see Figure 4-7 ) . 2. R epeat S t ep 1 for each[...]

  • Seite 53

    Connect Powe r Issue 1 Septe m b er 1995 4-13 1. Connect a 1 0 A W G w ir e t o the p ower cabinet ground di scharge bar. Se e Figure 4-9 ) . 2. R epeat for each p ort netwo r k c a b inet . NO TE: A C o u pled B o nding C onduc tor (CBC ) must b e t ie-wrapped to all trun k c a b les and t ermin ate d at the c o upled bond ing co nducto r termin a[...]

  • Seite 54

    Install a n d Co nnect th e Cab inet s 4-14 Issue 1 S e pt em ber 1995 ! CAUTION: Syste m groun ding s h al l com ply w i th th e gen eral ru les for grounding contained in Article 250 of the Nat ional E lectrical Code (NEC), National F ire Prot e c t ion Agency ( N F P A ) 70, or your a p p l icabl e l ocal electrical c ode. S e e A pp endix A for[...]

  • Seite 55

    Locate and Connect T i m e Division M u l tiplexing (TDM) Bu s Issue 1 Septe m b er 1995 4-15 Locate an d Conn ect Time Divisi o n Mu ltip lexing ( TDM) Bu s Locate t he wh ite f a bric-cov er ed T i me D i vision Multi plexi ng (T D M ) bu s c able. R efer to Table 4-1 for slot inform at ion. Foll ow t hese inst ru c ti ons to connect th e bus to [...]

  • Seite 56

    Install a n d Co nnect th e Cab inet s 4-16 Issue 1 S e pt em ber 1995 Figure 4-10. Time Division Multiplexing ( T DM ) Bus Connections for Standard -Rel iability Proc essor Port Netw ork (PPN ) 3 3 2 4 1 5 1 3 2 4 2 4 1. T ime Divisio n Multip l exin g (TDM) bus term i nat or AHF 110 o n Tim e Division Mu lt ipl exi ng )/Lo c a l Area Network p in[...]

  • Seite 57

    Locate and Connect Inter-Cab inet Cables (I CC) Issue 1 Septe m b er 1995 4-17 Locate an d Connect Inte r- Cabinet Cables (ICC) Connect th e In ter- Cabinet C abl es ( I CC) usin g these st eps: 1. R emov e th e I n ter-Cabinet Cabl e (ICC) from the lo wer b ack shelf of the cabin e t. 2. Connect th e ca bles as shown in F igure 4-11 and Tabl e 4-2[...]

  • Seite 58

    Install a n d Co nnect th e Cab inet s 4-18 Issue 1 S e pt em ber 1995 Figure 4-11. Inter-Ca binet Cab le (ICC) Connect ions for Standard R eliab ility Expansion Port Network (EPN) C abinet St a ck 1 2 3 4 5 1. P i nf ie ld pe r Table 4- 2 2 . C ab in et in Posi tio n B 3. In ter-Ca bine t Cab le s 4. B ackplane 5. Con trol Ca b ine t A P o s itio [...]

  • Seite 59

    Install Fib re-Optic Cables Issue 1 Septe m b er 1995 4-19 Instal l Fibre- O p t ic Cab les This sectio n discusses the hard ware a nd metho ds r e q uired t o connect and route f ibre- optic cabl es. The Expa nsion Port N e twork (EPN) c a b inet is norm all y p o sitio ned next to the Proces sor Port Network ( PPN) c a bine t(s), but may also be [...]

  • Seite 60

    Install a n d Co nnect th e Cab inet s 4-20 Issue 1 S e pt em ber 1995 Figure 4 - 12. Typ i cal Fibr e -Optic Cable Run ning List In the exampl e Running List in F i gure 4-12, connect a cable labeled 10426 6465 (20 feet long) f r om Cabine t 1, Carr i e r C, Slot 2, t o C a b inet 2, Carrier B , Slot 2. NO TE: The f ollowi n g ta sks re fer to t h[...]

  • Seite 61

    Install Fib re-Optic Cables Issue 1 Septe m b er 1995 4-21 Rule 3 R oute f ibre-optic cables away from groups o f o ther c a b les where they ma y b e stret ched by t h e weight o f me tal cable bundl es, as fi b re -op tic cable s are q u ite f lexible . Rule 4 Av oi d b ending f i b re-optic c a b les to a rad ius sm a ller than 1-1/2 inches (4 c[...]

  • Seite 62

    Install a n d Co nnect th e Cab inet s 4-22 Issue 1 S e pt em ber 1995 Figure 4-13. Fibre-Op t ic Cable In st a llation Between Shortwave Transc eivers, Direct Conn e ction TX RX 1 2 2 1 TX RX 1 2 3 4 1. Pr o ce ssor P o rt Netw ork ( P PN) C a bi ne t A S l ot 2A01 / 9 823- Typ e li g htwave tr ansce iver 2 . F L 2P-P-2 0 F ib er o p t i c c a b l[...]

  • Seite 63

    Install Fib re-Optic Cables Issue 1 Septe m b er 1995 4-23 Figure 4-14. Fibre-Op tic Cable Installation Between Longw av e Transceivers T hrou gh Fibr e-Optic Cross-Con nect Field Raised Flo or or Cable Slack Man agers Figure 4-1 5 shows the recom men ded fibre-optic ca ble rout in g for a single- carrier cabi n e t system with a c a b le sl ack ma[...]

  • Seite 64

    Install a n d Co nnect th e Cab inet s 4-24 Issue 1 S e pt em ber 1995 ! CAUTION: Do not route fi b re-optic c a b les an d the B25A cable s t oget her. Figu re No tes: Figure 4-15. Single-Carrier Cabinet Fibre Routing Cab le Co nnection s W hen rout ing fibre-optic ca bles, connect the c a b les (a ccording t o t h e R unning L ist provided in t h[...]

  • Seite 65

    Install Fib re-Optic Cables Issue 1 Septe m b er 1995 4-25 Stan da r d Reliab il ity Fibr e-O ptic Cab le Connections For S t andard Re l iabil i ty system configuration, route t he f ib re-optic c a b le as illustrat e d b e l ow. Figure 4-16. Fibre-Op t ic Cable Connections for Standard Reliability Single-Carrier Cabinet Sys tem 1 2 3 4 5 6 7 8 9[...]

  • Seite 66

    Install a n d Co nnect th e Cab inet s 4-26 Issue 1 S e pt em ber 1995 Hig h Reliab ility Fibr e -Optic Cab le Connecti o ns For H igh-Reli ab ilit y s ystem conf iguration , route the fib re-optic c a b les a s illustrat e d b e l ow. Figure 4-17. Fibre-Op t ic Cable Connections for High Reliability Single-Carrier Cabinet System 1 2 3 4 5 6 7 8 9 [...]

  • Seite 67

    Install Fib re-Optic Cables Issue 1 Septe m b er 1995 4-27 Critic al Reli ability F ibre-Op tic Cab le Connections For C ri tical R eliab ilit y system confi g uration, rout e the f ibre-op t ic c ables a s illustrat e d b e l ow.[...]

  • Seite 68

    Install a n d Co nnect th e Cab inet s 4-28 Issue 1 S e pt em ber 1995 Figure 4-18. Exp ansion Port Netw ork Fibr e-Optic Cable Connections for S ingle-Carrier Cabinet w ith Critical-Rel iability Swit ch 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Terminal AUX B C [...]

  • Seite 69

    Verif y P ort C a b inet Ad dress Pl u g s Issue 1 Septe m b er 1995 4-29 Verify Port Cab inet Ad dress Plugs The Cabine t Ad dress P lug i s a jump er and is required fo r s ingle- c arr ier p ort cabin e ts only . O n t he b ackpl ane of a port cabinet , to th e righ t o f s l ot 00 , a group o f six p ins is mark e d f or the c ab inet (c a rr i[...]

  • Seite 70

    Install a n d Co nnect th e Cab inet s 4-30 Issue 1 S e pt em ber 1995 Instal l Back Pane ls Inst all the b a ck panels, ti ghtening the screws when all p anel s are in place . A l low th e screws labeled ca l lout 4 in Figure 4-21 o n p a g e 4-31 to remain loose. Instal l Ground P late s The ground pla te (Figure 4-20) provide s the gr ound conne[...]

  • Seite 71

    Install Grou n d P lates Issue 1 Septe m b er 1995 4-31 See Fi g ure 4-22 and Fig ure 4-23 for illust rati ons of the g round p late and cable clamp p osit i ons . Install G rou nd Plates on Sy st ems with Earthquake Protectio n R efer to A p pe n dix B for eart hquake prote ct ion p r o cedures. Install G rou nd Plates on Sy st ems with o ut Earth[...]

  • Seite 72

    Install a n d Co nnect th e Cab inet s 4-32 Issue 1 S e pt em ber 1995 2 . At t h e upper cab inet, p l ace the top of the ground plate over t he bott o m of th e l ower-back panel s o t he f our screws at the b o tt om of the lowe r- b ack panel fi t through the f our ground p la te keyhole slots. T he bottom ed g e of the ground p late should ove[...]

  • Seite 73

    Install Grou n d P lates Issue 1 Septe m b er 1995 4-33 Figu re No tes: Figure 4 - 22. Single-Carrier Cabinet G round Plate, C a binet Clip, and Battery Loca tions 1 2 3 1. Cabine t C l ip 2. Ba tte ry 3. Back Ground Plate ■ S id e Vi ew o f 2-Cabin et Po r t Ne twork[...]

  • Seite 74

    Install a n d Co nnect th e Cab inet s 4-34 Issue 1 S e pt em ber 1995 Install Cab le Clamps At t he back of t he cabine ts, on each ground p la te, insta ll two c a b le clamp s using the screws provided (see Figure 4-23). These clamp s h old the 25-p air inp ut /ou tp ut or cross-connect field cables in p lace. Figure 4-23. Location of Cable Clam[...]

  • Seite 75

    Inst all Front Plat e s Issue 1 Septe m b er 1995 4-35 Instal l Front P lates The front pl ates provide elect roma gnetic radia t io n and radio freque ncy (RF) shieldi ng and earthq uake protec t ion. If you d o not have a req uirem ent for electromagnetic radi at ion shieldi ng , radio frequency shieldi ng, or earthq uake prote ct ion, use the ca[...]

  • Seite 76

    Install a n d Co nnect th e Cab inet s 4-36 Issue 1 S e pt em ber 1995 Figure 4-25. Location of Cabinet Clips 1 2 3 4 5 1. P o rt Cab ine t D 2. P o rt Cab ine t C 3. Cabine t clips 4. P o rt Cab ine t B 5. Bas ic Contro l Cabinet A Figu re Notes:[...]

  • Seite 77

    Issue 1 Septe m b er 1995 5-1 5 Install Telecommunication s Cablin g This chap ter describes h o w to inst all tel ecom munications ca b les and cross- connect equipment. The specific equipm en t being inst alled varie s on what wa s o r d ered for your site. Use the materi a l p resent ed in thi s c ha p t er as an exam ple. Instal l the Cr oss-Co[...]

  • Seite 78

    Inst all Te l ecommunicat ions C a b ling 5-2 Is sue 1 Se ptemb er 1995 Figure 5-1. Typical Cro ss-Conn ect Field Inst allation: 110A-Typ e Term inal Block s 3 2 8 7 4 5 5 5 5 1 6 1 . D Ri n g 2. T r unk a uxilia ry fiel d 3. P o rt d istributio n fie ld 4. S t at ion di stribution f ield 5 . Sta t i o n c a b l e s 6 . Swi t c h c a b i ne t 7. Z [...]

  • Seite 79

    Issue 1 S e pt em ber 1995 5-3 In Figure 5-1, a p proximat ely 57 6 4-P air or 76 8 3- Pair S tati on Capac ity is illust rate d . Hardw a r e Installat ion These hardwa r e ins tal la t ion instructions are writ ten so one syst em t echnician can install th e follo wing equ ipme nt : ■ Cross-c onnec t field ■ Cab le slac k manag ers ■ S neak[...]

  • Seite 80

    Inst all Te l ecommunicat ions C a b ling 5-4 Is sue 1 Se ptemb er 1995 ■ R oute the cable f r o m th e cabin e t t o t h e wall . P l ac e the c a ble beside one o f th e r ow s o f col um n s i n th e cabl e s l ac k m anager (see followin g not e). NO TE: R etainers m ount ed on the column s k eep th e cable from protruding a b o ve the t o p [...]

  • Seite 81

    Issue 1 S e pt em ber 1995 5-5 Figure 5-2. Cab l e Routing Thr ough Cab le Slack Manager for Single Cab inet Installat ion 45 2 1 3 1. C ab l e Cla mp 2. T runk A uxiliar y F i e ld 3 . Swi t c h Ca b i ne t 4. C a b in et Tr ou g h for P ort Cab le s 5. Sp are Ce nte r Trou g hs Figu re Notes:[...]

  • Seite 82

    Inst all Te l ecommunicat ions C a b ling 5-6 Is sue 1 Se ptemb er 1995 Figure 5-3. Typ ical Port Cable In st allation at Switch Cabine t Conne ct Control Carrier Outputs Cab le P l ug the connector c a ble in the AUX connector o n the rear o f the cont rol carrier. R out e th e connec tor cable t hrough the c a b le slack manager to the assi gned [...]

  • Seite 83

    Issue 1 S e pt em ber 1995 5-7 La be l Cable s Label th e ca b les a s d e sc rib e d in this secti on. The port label shown in the next fi gure is insta lled on b oth e n d s of t he 25-pair cables connecting t o the tr u nk/auxi liary fi eld an d /or the d istrib u t ion f ield. See Ta b l e 5-1 for the c a b le label and colour c ode. The b uild[...]

  • Seite 84

    Inst all Te l ecommunicat ions C a b ling 5-8 Is sue 1 Se ptemb er 1995 R oute the incoming t runk cabl e s t hrough the lig htnin g prote ctor and t he n to t he Snea k Current Protec to r (507B). T he 25-p air cabl e t hen g o es t hrough the trunk cross- c onnect field and t hen to th e port .[...]

  • Seite 85

    Issue 1 S e p tem ber 1995 6-1 6 Install Generic 3 Management Terminal This chap ter cont ains Gene ric 3 Manage me nt Term ina l ( G3-MT ) requ irements. Also detailed is: ■ How to di re ctly connect a t er mi na l to t he switc h ■ How to set u p the term ina l ■ Altern ative p r o cedure to remot ely connect a ter m inal to the swit ch. Th[...]

  • Seite 86

    Inst all Ge neric 3 Ma nagement T erminal 6-2 Is sue 1 Se ptemb er 1995 Mains p ower for t he term inal must b e o btai ned from a st andard volta g e source in th e range of 115 to 230 volts AC in the eq u i pme nt room. The t ermi nal is au to-s ensing a n d a utoma tically ad just s to re c eive the typ e of AC p ower at the site. An o p ti onal[...]

  • Seite 87

    Connect Gene ric 3 M anagem ent Term inal (G 3-MT) Issue 1 Sep te m b er 1995 6-3 2. If you have a DC-power ed switch co ntrol c a b inet or if yo u ne e d electro magnetic s hi eldin g , locate th e 116A Electroni c I n d u stries As sociat io n ( E I A) Ground I solat or (c o m c ode 106 005 242) a n d i nstall it in the TERM INA L connector on t[...]

  • Seite 88

    Inst all Ge neric 3 Ma nagement T erminal 6-4 Is sue 1 Se ptemb er 1995 Figure 6-2. Direct Conn ections to Generic 3-Managem ent Terminal (G 3-MT) an d Electronic Industries Ass ociation (EIA) Groun d Isolator 5. Connect th e keyboard cord t o the KBD jack on the term inal. 6 . I f or d ered, connect the opt i onal p r i nter to the a p p ropriate [...]

  • Seite 89

    Connect Gene ric 3 M anagem ent Term inal (G 3-MT) Issue 1 Sep te m b er 1995 6-5 7. Connect AC power cord of the term inal to the selecte d AC r e cept acle i n the e q u i pmen t room and turn on th e terminal. Figure 6-3. Duplication Op tional Term inal and Termin a l Connec tors on the Control C abinets Figure 6-3 shows the two possible p ositi[...]

  • Seite 90

    Inst all Ge neric 3 Ma nagement T erminal 6-6 Is sue 1 Se ptemb er 1995 Set Up G 3 Mana gement Ter minal (G3-M T) Use the followin g proced ures to set u p the 715 Man agemen t Terminal o p t ions: NO TE: These p roced ures may c hange as t he mo de l of 715 M anagement Term ina l (G3-MT) sh ip p ed with D EF I NITY S ystem Generi c 3 changes. Cons[...]

  • Seite 91

    R e motely Conne ct Gen eric 3 Manage men t T ermi nal (G3-MT ) Issue 1 Sep te m b er 1995 6-7 Remot ely Co n nect Generi c 3 Manage ment Termin al (G3-M T) A secondary (and op t ional ) termi nal used for p urposes othe r t han ma int enance can be installe d at some d ista nce from the switc h . Typ ical rem ote c o n nect ions are shown i n the [...]

  • Seite 92

    Inst all Ge neric 3 Ma nagement T erminal 6-8 Is sue 1 Se ptemb er 1995[...]

  • Seite 93

    S eptember 1995 Is s ue 1 7-1 7 Activate the System This chap ter cont ains proce dures for a c t ivati n g th e system a n d bri n g i n g the switch up to a non-alarm (no r e d l ights) sta te. This chap ter de t ail s: ■ Powe ri n g u p t h e sw i t c h ■ Install ing tr a nslati on fla sh -mem ory ca rd ■ Powe ri n g u p A C-powered switch[...]

  • Seite 94

    A c tivat e the S ystem 7-2 S ep te mber 1995 Issue 1 Com pa ti b ility (EMC) wrist strap (comcod e 900 698 226) when handling circuit packs o r ot her switch co mp onent s. Power Up Swi tch T o power up the s witch , do the fol lowing: Install Tran sl ation Fl as h-M emo ry C ard 1. Verif y the w rit e swit c h on the whit e Translat ion Flash-M e[...]

  • Seite 95

    Powe r U p S witch S e p t e m b er 1995 Issue 1 7-3 Power up A C- Po wered Swi tc h 1. Ensure th e as sociat ed circuit breakers o n the AC p ower panel are ON . NO TE: If the system i s c o nfi gured fo r High o r C r itica l R e liab ility, p o w e r -up the E xpansion P ort Network (EPN) cabi net first, then th e P rocessor P ort Network ( P P [...]

  • Seite 96

    A c tivat e the S ystem 7-4 S ep te mber 1995 Issue 1 Scre en 7-1. Typic al Turn -On Messages for System s with FLAS H Memor y 2. About 2 m inut es after REBOOT PERFORMED is displayed, verify t he termina l scree n displa ys : Login : NO TE: Most red l ig hts wi ll co me on an d g o of f a g ain at this p o int. S om e red ligh ts w i ll sta y o n [...]

  • Seite 97

    Log in to the Syste m S e p t e m b er 1995 Issue 1 7-5 Com m ands Syste m c o m m ands are sta nd ard words and phras e s inst ructin g the switc h t o perf orm a specific f unct ion. The c o m ma n d s a re arranged in hier arc hy of keywords; that is , en ter one c o m m and to t ake you to a different level. T he com mands cont ain three p arts[...]

  • Seite 98

    A c tivat e the S ystem 7-6 S ep te mber 1995 Issue 1 3. Verif y t he screen disp lays: password : 4. Type crftpw and press EN T E R . For securit y reason s , the p a s sword is no t disp layed as i t is type d. T he system verifies a valid logi n a nd password name were ent ered. If a n invalid lo gin o r p as sword name was en tered, the screen [...]

  • Seite 99

    S et Re quired Co untry O p tio ns S e p t e m b er 1995 Issue 1 7-7 3. The d e f a u l t is M u-Law. If your c ount ry uses A-Law c om p a nding , type A-Law. If i t uses Mu-Law a n d Mu-Law is d isplayed, go t o S te p 4 bel ow. C o mpand ing m ode can b e A -law or Mu-law. The s wi tc h should have been shipped w i t h t h e correct Tone De t e [...]

  • Seite 100

    A c tivat e the S ystem 7-8 S ep te mber 1995 Issue 1 5. I f all t he red l ight s do no t g o o ff , r esea t (unplug a nd reinsert) any purp le-labeled circuit p acks d isplay ing red lights . ! CAUTION: T o avoid a disk crash, never reseat the D E F I NITY AUDIX Syst em without first shu t t in g it d own. Shut down the D EF I NI T Y AUDIX S y s[...]

  • Seite 101

    Change C raf t Password S e p t e m b er 1995 Issue 1 7-9 Alarms will a p p e a r in the Al arm L o g when p ower i s a pplied t o th e s yste m be fore all e q uipmen t connecting to port c ircuit packs is installe d . Normally, some alarms will b e logge d when p ower i s a pplied to the sy s tem, but should be resolve d quick l y . I f n o equ i[...]

  • Seite 102

    A c tivat e the S ystem 7-10 S e p t e m b er 1995 Issue 1 Scre en 7-2. T ypical Chan ge Pas sword S creen 3. Verif y t he screen disp lays Change P asswor d S creen. Cursor is positi oned on ‘ ‘ Password for Login Making Change: ” 4. Type the p assword assigned to t he craft login (assigned as crftpw when sy ste m is ship pe d) and press ENT[...]

  • Seite 103

    S e t Date an d T ime S ep tember 1995 Issue 1 7-11 S e t Da te an d Tim e The s ys t e m d a t e a n d t im e are set using the S et Date an d T ime Scr e en (see Screen 7-3). This screen i s d isplayed on th e ter m inal s c re en an d i s change d wit h the t erminal keyboard. T o set the system time a nd d at e, p e rform the followin g : 1. Ve[...]

  • Seite 104

    A c tivat e the S ystem 7-12 S e p t e m b er 1995 Issue 1 Cursor is positi oned on Month: field. 5. Type c ur r ent mont h in Eng lish (Januar y t hrough Decemb er) and press TAB to move to next f ield. See Ta ble 7- 3 fo r En gl ish mon th names. Cursor is positi oned on Year: field. Cursor is positi oned on Day of the Month: field. Tabl e 7-2. E[...]

  • Seite 105

    S e t Date an d T ime S ep tember 1995 Issue 1 7-13 6. Type day o f mon th ( 1 through 3 1) and press TA B to move to next fi eld. Cursor is positi oned on Year: field. 7. Type current year (for examp le, 1995) a n d press T AB to move to next f ield. Cursor is positi oned on Hour: field. 8. Type current hour for 24-ho ur clock ( se e Tabl e 7-4) a[...]

  • Seite 106

    A c tivat e the S ystem 7-14 S e p t e m b er 1995 Issue 1 NO TE: The Set Dat e an d Tim e Screen is d isplayed showing all d ata en tered in t he p revious ste p s followed b y : command: Se t System M a inte nance P arameters NO TE: If you do not have a TN778 circui t p ack, skip t his proced ure and p roceed to " Save Translat ions" on[...]

  • Seite 107

    Save Translat io n s S ep tember 1995 Issue 1 7-15 3 . Mov e th e cursor by pr es s i ng TAB t o move d own the screen fr om fiel d to f ield a nd e nter y in the Packet Bus Activated? f ield to i n dicat e you have a TN 778 circuit pack. This is th e only fi eld needing change o n t his scree n to turn t h e re d li g h ts off . 4. Press ENTE R wh[...]

  • Seite 108

    A c tivat e the S ystem 7-16 S e p t e m b er 1995 Issue 1 Scre en 7-5. Typical Save Translation Sc reen 4. Verif y a 0 i s displ ayed i n t he Error Code column for each swit c h proces s i ng element in the s ystem . A 0 indicates the save t ranslation was successfully com pleted for th e translatio n c ard. If a 0 di d not a p pear, th e save tr[...]

  • Seite 109

    Save Translat io n s S ep tember 1995 Issue 1 7-17 Logoff Log off th e system to p revent unauthori zed changes o f the d at a . To log o f f: 1. Type l ogo ff and press E N TER . 2. Verif y th e screen displays : Login: NO TE: The l o g i n p r o m p t i n d icates yo u have l o g g e d o ff the system and i t is ready fo r an o ther p e rso n to [...]

  • Seite 110

    A c tivat e the S ystem 7-18 S e p t e m b er 1995 Issue 1[...]

  • Seite 111

    Issue 1 S e p tem ber 1995 8-1 8 Test the System The fo llowin g test s p rovi d e verif icat ion o f the Ti me Division Mu ltip l e xi n g (T DM) cable s an d term inat ors, a n d fi b re-optic in ter-cabi net c a b les (ICC). I f a F A I L R esult c o d e is seen or othe r p ro blems are i ndic ated, check t h es e c a b les. I f probl em s pe r [...]

  • Seite 112

    Test t he S ystem 8-2 Is sue 1 Se ptemb er 1995 3. Verif y t he screen disp lays system status sc r eens simila r to the exam p l e shown be l ow: Scre en 8-1. Example Syst em Status Screen for Cabinet 1 NO TE: In t he first section o f th e repor t, a ll Tone-Clocks should rep ort a SERVICE STATE of in . NO TE: I n t h e s econd sect ion of the re[...]

  • Seite 113

    Check the Sy ste m Sta tus for Each C a b inet Issue 1 Sep te m b er 1995 8-3 Screen 8-2. Example Sys t em Status Screen for Cabinet 2 NO TE: S e e the notes associate d with Screen 8-1 on the previous p a g e. status system all-cabinets Page 2 of 3 SPE A SYSTEM STATUS CABINET 2 SELECT SPE ALARMS TONE/ SERVICE SYSTEM SYSTEM SPE MODE SWITCH MAJOR MI[...]

  • Seite 114

    Test t he S ystem 8-4 Is sue 1 Se ptemb er 1995 Scre en 8-3. Example Syst em Status Screen for Cabinet 3 NO TE: S e e the notes associate d with Screen 8-1 on the previous p a g e. NO TE: In t he exampl e o f Screen 8-3, c a b inet 3 (the s econd E x p ansion P ort Ne twork (EP N)) is not connecte d to the system. Check Circui t Pack Con f igu rati[...]

  • Seite 115

    Check Circuit Pack Confi g u ra tion Issue 1 Sep te m b er 1995 8-5 4. Not e an y d isp lays for boards t h at say in the VINTAGE column: BOARD NOT PRESENT or CONFLICT . Screen 8-4. Exam ple System Conf iguration Screen — Page 1 NO TE: Unde r Assigned Ports , a “u” indi ca t es unassigned ports and a nu mb er ind icate s th e port has b een t[...]

  • Seite 116

    Test t he S ystem 8-6 Is sue 1 Se ptemb er 1995 Scre en 8-5. Example Syst em Configuration Screen — Page 2 Page 2 SYSTEM CONFIGURATION Board Assigned Ports Number Board Type Code Vintage u=unassigned t=tti 01C02 DIGITAL LINE TN754B 000001 u u u u u u u u 01C04 CO TRUNK TN747B 000012 u u u u u u u u 01C05 E&M TIE TRUNK TN437B 000001 u u u u 01[...]

  • Seite 117

    Check Circuit Pack Confi g u ra tion Issue 1 Sep te m b er 1995 8-7 Screen 8-6. Exam ple System Conf iguration Screen — Page 3 list configuration all Page 3 SYSTEM CONFIGURATION Board Assigned Ports Number Board Type Code Vintage u=unassigned t=tti 01C15 DS1 INTERFACE TN767 000017 u u u u u u u u u u u u u u u u u u u u u u u u 01C17 CALL CLASSIF[...]

  • Seite 118

    Test t he S ystem 8-8 Is sue 1 Se ptemb er 1995 Scre en 8-7. Example Syst em Configuration Screen — Page 4 configuration all Page 4 SYSTEM CONFIGURATION Board Assigned Ports Number Board Type Code Vintage u=unassigned t=tti 02B01 TONE/CLOCK TN780 000005 02B02 EXPANSION INTRFC TN570 000009 02B04 ANALOG LINE TN2135 000003 u u u u u u u u u u u u u [...]

  • Seite 119

    Test Ti m e Division Multi p lexor (TDM) Bu s in Proc essor Port Ne twork (PPN) Issue 1 Sep te m b er 1995 8-9 Screen 8-8. Exam ple System Conf iguration Screen — Page 5 Test Time Divisi o n M u ltiplexor ( TDM ) Bus in Processor Po r t Network (PPN) 1. Verif y t he screen disp lays: command: 2. Type test tdm port-netwo rk 1 and press ENTE R . 3.[...]

  • Seite 120

    Test t he S ystem 8-10 Issue 1 S e pt em ber 1995 Scre en 8 - 9 . Exam ple Test Results fo r Tim e Division Multiplexing ( T DM) Port N etwork 1 4. If the result is FAIL for any test, check t he connecto rs of the T i me Division Mul tiplexing ( T D M) bus cable s in P r o cessor P ort Network ( P PN) 1 . Test Ton e-Cl ock Boa r ds Testi n g th e T[...]

  • Seite 121

    Test S w itch Processing Ele men t ( S PE ) Duplicat ion Memory Shad owin g Link Issue 1 Septe m b er 1995 8-11 Screen 8-10. Exam ple Test Resu l ts fo r Ton e -Clock 1A Test Sw i tch Proce s sing Ele m e nt ( S PE) Duplicat ion Memory Sha d owing Link For H igh and Criti c al Rel iabil i ty system s, test the Swit ch P rocessing Ele me nt (SPE ) d[...]

  • Seite 122

    Test t he S ystem 8-12 Issue 1 S e pt em ber 1995 Scre e n 8-11. Exam ple Test Results fo r Switch P rocess i ng E lement D u plication M emory Shadow i ng Link 4. If result is FAIL for any test , check th e In te r- Cabinet Cables (I CC) in the P rocessor P ort Net work (PP N) . Test Du p licat ed Swi tch Pro cessing Elemen t (SPE) I nterchan g e [...]

  • Seite 123

    Test D u p licate d Switc h Processing Eleme nt (SP E) I n terchang e Issue 1 Septe m b er 1995 8-13 Screen 8-12. Exam ple System Status Repor t for All Cabinets 4. Not e the MODE of SPE 1A and 1B . 5. Type refresh spe and press ENT E R . Command successfull y completed should b e d isplayed. 6. Type reset system interchan ge and p r ess ENT E R . [...]

  • Seite 124

    Test t he S ystem 8-14 Issue 1 S e pt em ber 1995 Scre en 8-13. Example System Status Report for All Cab inets after Reset 10. Not e the MODE for SPE 1A and 1B shoul d have changed from tha t note d in S t e p 4. Test Expan sion Interface Boards Check each expansio n i n terface board in t he system. 1. Verif y t he screen disp lays: command: 2. Ty[...]

  • Seite 125

    Test Ti m e Division Mult i plexer (TDM ) for each Expansion Port Ne twork (E P N ) Issue 1 Septe m b er 1995 8-15 Screen 8-14. Example T es t Results for Expans ion Interfac e Board 2A 0 1 If any result is F AI L, c h e c k the connectio ns fo r th e ass ociated fiber optic link. 4. R epeat S t eps 2 and 3 for each expansio n int er fac e board in[...]

  • Seite 126

    Test t he S ystem 8-16 Issue 1 S e pt em ber 1995 Scre e n 8-15. Examp le Test Results for T ime Divis io n Multiplexing ( TDM ) Port Networ k 2 4. If Result is FAIL for any t est, ch eck the connectors o f th e Time Division Mult iplexin g (T D M) bu s cables in Proces sor Port Ne twork (PPN ) 2 . 5. R epeat these ste p s f or each Expansion Port [...]

  • Seite 127

    Test Tone -C lock In terchange for each Exp ansion P ort Network ( E PN ) Issue 1 Septe m b er 1995 8-17 Test Ton e-Clock Int erchange for each Expan sion Po rt Network (EPN) If the system is set up with Cri tical R eliab ility, t est the Tone-Cl ock int er c hange fo r each Ex p ansion P ort Network ( E PN). 1. Verif y t he screen disp lays: comma[...]

  • Seite 128

    Test t he S ystem 8-18 Issue 1 S e pt em ber 1995 Scre en 8-16. Example of System Sta tus before Expansion Link is Set 3. Type set expans i on-l i nk xxxx where xxx x is the either one of the cabi net, carrier, and port (see note o n p age 8-1) locat ions of the sta n d b y expansion l ink. 4. Verif y t he screen disp lays: Command successful ly co[...]

  • Seite 129

    Check Circuit Pack Confi g u ra tion Ag ain Issue 1 Septe m b er 1995 8-19 Screen 8-17. Exam ple of S ystem Sta t us after Expans i on L ink is Set 6. Verif y t he MODE s of the expa nsion links have changed . 7. If any p roblems are indica te d, c h eck th e T i me Division M u lti plexing ( T DM) cable s an d th e i nt er-cab inet c ables (ICC ) [...]

  • Seite 130

    Test t he S ystem 8-20 Issue 1 S e pt em ber 1995 Save Translat ions, if Required If an y a dmi nistration c h anges have been mad e, save and ma ke a b a c k u p c o py of the transl ati ons. See Chapte r 7 , "Activat e th e System " fo r d et aile d in s t ruct ions. Re-i nstall Fro n t D o ors P u t the d oors back on the cabin ets aft[...]

  • Seite 131

    Issue 1 S e p tem ber 1995 9- 1 9 Install and Wire Teleph o nes an d Other Equipmen t The wiring p roced ures are the same for most of the DEFI N IT Y System Generic 3 t elepho nes and oth er e qu ip men t . This sectio n provides wiring examp les. T hese are examp l es onl y and w iring proce dures may differ at each site. Th is se ctio n provides[...]

  • Seite 132

    Inst all a n d W i re Te leph ones an d Other Eq uipmen t 9- 2 Is su e 1 September 1995 auxilia ry connect or. W hen possibl e , th e primary c onsole should be powered from the system cabi net so it has the same power fa ilure b a cku p as the syst em it se lf. The m aximum cabling dis t ance for th e console powered from the cab inet is 350 feet [...]

  • Seite 133

    Telephone Conn ection Examp l e Issue 1 Septe m ber 1995 9- 3 Figu re No tes: Figure 9-1 . 302B to T N75 4 Wiring Exam ple Co nn ec t Adj un ct P o wer 1. For term inals nee ding a djunct p ower (such as A tt endant Console 302B), wire -48V an d ground to ap propriate p i nouts on th e term inal, as shown in T a ble 9 -2 and i n F igure 9 -2 . S ee[...]

  • Seite 134

    Inst all a n d W i re Te leph ones an d Other Eq uipmen t 9- 4 Is su e 1 September 1995 Figu re No tes: Figure 9-2. Adjunc t Power Wirin g Examp l e (302B) 2. The 400B2 a d a p t er is conven ient f or c onnectin g local po wer to a modular plug. See F i g ure 9 -3. Figure 9-3. 400B2 Adapter Connec ting to a Modu lar Plug 7 8 -48 GN D -48 GND 3 4 1[...]

  • Seite 135

    Analog St ati on or 2 - W ire Digita l St a t ion Ex amp le Issue 1 Septe m ber 1995 9- 5 Adjunct power can be provided fro m th e equipment r oom o r e quipm ent closet with 114 5 B1 power u ni t. See " Inst all the 1 145B 1 Power Sup p l y" on p a ge 9 -26 for more inf ormatio n. Each DEFI NI T Y S ystem p ort net work can provide p owe[...]

  • Seite 136

    Inst all a n d W i re Te leph ones an d Other Eq uipmen t 9- 6 Is su e 1 September 1995 The fo l lowin g diagr a m i l lustra tes the se wirin g designa t ions. Figu re No tes: Figure 9-4 . Analog Station 2500 to T N 2183 A nal og Li ne W iring Ex a m ple Anal og Tie Trunk Example S t eps 1-3 of ea ch exampl e should have b ee n c om plete d in the[...]

  • Seite 137

    A nalog T ie Tr un k Ex ample Issue 1 Septe m ber 1995 9- 7 3. Choose a port ci rcuit o n the port circuit p ack (such a s Port 02 ). 4. S et o p t ion swit ches on the port board ( T N 760 t ie trunk) as described i n Ap pendix H, "Opti on Swi tch S e t tings" . 5. I ns ta l l cross-connect j u mpers to c onnect th e named p inout s from[...]

  • Seite 138

    Inst all a n d W i re Te leph ones an d Other Eq uipmen t 9- 8 Is su e 1 September 1995 Figu re No tes: Figure 9-5 . A nalog Tie Trunk Wiring Exam ple ( TN 760) In Figure 9 -5 , the follo wing a b breviat ions a p p ly: T , R P rivate B ranch E xchange ( PBX ) v o ice transmit T 1 ,R 1 P rivate B ranch E xchange ( PBX ) v o ice r ec eive M P rivate[...]

  • Seite 139

    Digit al T ie Tr u n k Ex ample Issue 1 Septe m ber 1995 9- 9 Digi tal Tie Trunk Example S t eps 1-3 o f each exam ple shoul d have be en c o mp l et e d in the Pr ovisi oning Plan i n Chap ter 2, " Plan a n d Prepa r e t he S ite" , S tep 8. This example shows how to connect di gital t ie t runk wiring f rom one D E FINI T Y Syste m G en[...]

  • Seite 140

    Inst all a n d W i re Te leph ones an d Other Eq uipmen t 9- 1 0 Issue 1 S e pt em ber 1995 Figu re No tes: Figure 9-6 . TN 4 64 Wiring Exampl e Auxil iary Conn ector Ou t pu ts The cont rol carrier outp uts c a ble pin outs are shown in Tabl e 9 -6 on p a g e 9 -11. The cont rol carrier AUX connector ou tp uts include t he f ollo wing: ■ Alarm m[...]

  • Seite 141

    Auxi liary Connector Ou tpu ts Issue 1 S e p te mb er 1995 9- 1 1 Tabl e 9-6. Auxiliary L e a d A p p earan ces at AUX Connector on Cabinet B ack Single-Carrier Auxiliary Connection Outpu ts 8 08A 574 -5 Emergency Po wer Pin Transfer Unit T rans fer Unit Col or 1, 2 Numb er Ou tput s Outpu ts W-BL BL-W 26 1 M a jo r * TC TC W- O O-W 27 2 Min or* T [...]

  • Seite 142

    Inst all a n d W i re Te leph ones an d Other Eq uipmen t 9- 1 2 Issue 1 S e pt em ber 1995 * Ex ternal alarm, wit h si gnal incoming t o s witch. ** E xternal alarm, wit h si gnal outgoi ng from switch. 1 Colo r designa tion is AA - BB, wh ere AA is the main wire color, and B B is the color of the sh ort strip e on the wire. 2 For translatio n pur[...]

  • Seite 143

    Auxi liary Connector Ou tpu ts Issue 1 S e p te mb er 1995 9- 1 3 Tabl e 9 -7. Port Bo ard and Telephone Pin Des ignations Pin o n Modular plu g 4-wire; 302B, 8403 , 841 0 , 8 434 , 603E, 9403 , 943 4 2-wire; 302B, 8403 , 841 0 , 8 434 , 603E, 9403 , 941 0 , 9 434 8510T Basic Rate Interfa ce (BRI) (with adjun ct spea ker phone) Analog Station, Mode[...]

  • Seite 144

    Inst all a n d W i re Te leph ones an d Other Eq uipmen t 9- 1 4 Issue 1 S e pt em ber 1995 Figure 9-7. Connections for Attendant Cons ol e TXT TXR PXT PXR 11 13 13 12 10 9 8 7 6 5 4 3 2 1 P+ P- P+ P- P+ P- 1 . Sta t i on Wi r in g 2. Atte nda nt C onsole 3. In form a tio n Outl et 4 . S atel li te si te, o r ad a p ter lo c atio n 5. P a r t or cr[...]

  • Seite 145

    A PP Conne ct o r an d Cable Diagra ms ( P i nout Cha r ts ) Issue 1 S e p te mb er 1995 9- 1 5 Figu re No tes: 1 . Cabl e co nn ec tio n Figure 9-8 . 302B1 Attendant Co nsole APP Con nector an d Cable Di agrams (P in ou t Ch a rts ) See Ta b l e 9-9 fo r l ead d esignatio ns . The circuit packs and auxiliary eq u ipmen t are c lassif ied a s fol l[...]

  • Seite 146

    Inst all a n d W i re Te leph ones an d Other Eq uipmen t 9- 1 6 Issue 1 S e pt em ber 1995 Table 9 -8 . Circuit Pack and Au xiliary Equipment Classif ications . Ana lo g Line (8 ) 2-Wire Digita l & Ana log L ine ( 16) Data Li ne Digita l Line 4- Wire Hyb r id Line MET Line Aux ilia ry Trunk Central O ffice Trunk DID/ DIOD Tr unk Tie Trunk DS1 [...]

  • Seite 147

    Issue 1 S ep temb er 1995 9-17 Tabl e 9 -9 . Circu i t Pack a nd Auxiliary Equ ipment Leads (Pinout Charts) Color 1,2 Conn. Pin Numbe rs Ana lo g Lin e 8 ports 2- Wi re Digita l Line and Ana lo g Line 16 ports Data Lin e Digita l Lin e 4- wi re Hybrid Li ne MET Li ne AU X Tr k. CO Trk. CO Tr k. 3-wire DID/ D IOD Trk. Tie Trk. DS1 Ti e Trk. ISDN BRI[...]

  • Seite 148

    Install and W ire T elep hones and Other E q uip ment 9-18 Issue 1 S ep temb er 1995 BL-BK 11 R7 TXR4 TXR4 C R4 TXR4 SZ1 4 R1 4 PXT6 R1 1 BK -O 3 7 T8 PXT4 PXT4 P -4 P XT 4 S4 E4 TXT6 T1 2 O -B K 1 2 R 8 PXR4 PXR4 P + 4 PXR4 S 14 M 4 TXR6 R 12 BK -G 3 8 T5 T9 V1T5 T5 T5 P X R 7 G- BK 1 3 R 5 R9 V1R5 R5 R5 PXT 7 BK - B R 3 9 T1 0 TXT5 TXT5 C T4 TXT7[...]

  • Seite 149

    Issue 1 S ep temb er 1995 9-19 V- G 4 8 T1 5 TXT8 TXT8 C T8 L O PX R 1 2 G -V 2 3 R1 5 TXR8 TXR8 C R8 L O * PXT1 2 V-B R 4 9 T1 6 PXT8 PXT8 P-8 LB A CK 2 TXT12 BR -V 2 4 R 16 PXR8 PXR8 P + 8 LB A C K 1 TXR12 Tabl e 9 -9 . Circu i t Pack a nd Auxiliary Equ ipment Leads (Pinout Charts) — Continued Color 1,2 Conn. Pin Numbe rs Ana lo g Lin e 8 ports[...]

  • Seite 150

    Install and W ire T elep hones and Other E q uip ment 9-20 Issue 1 S ep temb er 1995 This p a g e left int enti onall y b l ank so you can remo v e t he pinou t chart fro m th e book if necessary . V- S 5 0 S- V 2 5 † Th e wire col ors in this pinout chart apply only t o B25A and A 25B c ables. H600-307,60 c able colors are not shown. W ithin thi[...]

  • Seite 151

    Install I nit iali zat ion and A d mi nist ra tio n S y stem (INA DS) Int erf ac e Issue 1 S e p te mb er 1995 9- 2 1 Instal l I nit ializa ti o n an d Admini stration S yste m (INAD S) Interface The In i t ia lizat ion and Adminis tra t ion Syste m (INA D S) p rovi des a 1 200 B its Per Second (bps) modem c onnect ion f or the remo te m anagement [...]

  • Seite 152

    9- 2 2 Issue 1 S e pt em ber 1995 Figure 9 -10. Initia lizati on and Ad min istration System ( INADS) Ins tallation for Digital Trun k Ac cess 1 2 3 4 5 6 7 G3 8 9 T R T R 1. D igital Ce ntral Offic e (CO) trunk ( T N 464) 2 . Ana lo g lin e (T N21 83 ) 3. In i tializati on a nd Adm inistra tion System (INADS ) Inte rfa ce (T ,R ) 4. Analo g exte n[...]

  • Seite 153

    Inst all E mergency Transfer Units and Associat ed Telephones Issue 1 S e p te mb er 1995 9- 2 3 Install E mergency Transfer Un its and Associ ated Te lepho nes E mergency t ransfer ca p ab i li ty is provide d b y a transfer unit m oun ted o n t he wall next to t he trunk/auxil iary cross-connect field . Analog telep hones can be used for eme rgen[...]

  • Seite 154

    9- 2 4 Issue 1 S e pt em ber 1995 Instal l Extern al Ringi n g Req uirements Figure 9 -11 on p a g e 9 -25 shows the c o nnect ions for exte rnal ringing provided by a device, su ch a s a gong, chime , or b ell, c o nnected to an in format ion out let . The switch side o f t he cr os s-connect field is connected to a n anal og line c i rc uit pack [...]

  • Seite 155

    Install Q u eue W arning In dica tor Issue 1 S e p te mb er 1995 9- 2 5 Figure 9-1 1. Con nec tions for External Ringing or Qu e ue W arning Indicator Instal l Queue Warni ng Indi cator Req uirements Figure 9 -11 shows the connect ions for the queue warning ind icator . An AC in dicator ( lam p) such as a 21 C49 is op tional f or use as a q ueue wa[...]

  • Seite 156

    9- 2 6 Issue 1 S e pt em ber 1995 Installat io n Install q ueue warning i ndica to r as follows: 1. Det ermine port assignment for q ueue warning i ndicator from Hunt Group F orm: 2. I ns ta ll patch cor d /j umper wires at cross- c onnect field. 3. M ount in dica tor at s p e cified locati on. 4. Conne ct a 2-pair line c o rd (mo d ular p l u g at[...]

  • Seite 157

    Install t he 1145B 1 Power S up p l y Issue 1 S e p te mb er 1995 9- 2 7 32. T h e 1145B1 (no t 1145A1) is re q uired f o r i nstal lat ion out sid e the Unite d S t ates. Au xiliary power (local o r b u lk) is always r e quired in th e fo llowin g situ ati ons: ■ At tendan t console 302 B. ■ An y 852 0 te rm inal. ■ Any 7500 -series or 8500-[...]

  • Seite 158

    9- 2 8 Issue 1 S e pt em ber 1995 Figure 9-1 2. 1145B1/1146B 1 Mountin g Arrangem en t 2 9 1-8 1-32 3 5 8 7 Output Power On Charging Battery On Battery Reserve 1145A1 Power Unit 4 6 1 1 10 1. W all mo unti ng pla te 2. 2 .5 Amp H o ur Ba t te r y 3. Batt ery bracket 4. AC p ow er cord 5. 1 146B power distributio n un it 6. Unswit c h e d o utl et 1[...]

  • Seite 159

    Install t he 1145B 1 Power S up p l y Issue 1 S e p te mb er 1995 9- 2 9 Mount t he 1145B1 Power Supply The 1145B1 P ower Sup ply u nit is s nap-fi tted o nto the bo t tom wal l mounti ng p late without tools. 1. P erform this ste p using a "p l ace, ro tate , the n s nap " mo t ion. T he holes used for 1 145B1 P ower Sup ply moun ting ar[...]

  • Seite 160

    9- 3 0 Issue 1 S e pt em ber 1995 2. A n instal ler-provided insul ated ground w ir e, 1 6 A WG or grea ter, is requ ired to c onnect the Po wer S u p ply frame g round lug t o an a pproved ground. T he P ower Sup ply fram e ground s c rew is located nex t to t he AC recept acle to the l eft o f the unit . The ground screw and the AC receptacl e ar[...]

  • Seite 161

    Install t he 1145B 1 Power S up p l y Issue 1 S e p te mb er 1995 9- 3 1 Power U p and Test Powe ri n g u p a n d t esti ng should be perf ormed only after all the hard ware is prop erly mount e d. The fo llowi n g t a b le describes the meaning of the Power Su pply ligh t e mi tt ing diod es when lit. 1. Conne ct the AC power cord t o Power Sup p [...]

  • Seite 162

    9- 3 2 Issue 1 S e pt em ber 1995 Wir e t he 1146B1 Power Distri bution Unit I t may be b etter to wire endp o i nts to the 1146B1 whil e p ower from the 11 45B1 is on. This way, a re d li ght emitti ng diod e ( LED) on th e distrib ution unit lights if you connect i ts associat ed c ircuit to s horted b uildin g wir ing or to a s horted ter m inal[...]

  • Seite 163

    Install t he 1145B 1 Power S up p l y Issue 1 S e p te mb er 1995 9- 3 3 Reset Light E mitti n g D iod es (LED ) on Pow er Distr ibution Unit A lit r e d li g h t em itti n g di o d e (L ED) n ext to a ny of the 3 2 p o wer ou tp ut connectors on the P ower Distr i b uti on Unit in dica tes a short circuit i n the buildi ng wiring or the t erminal [...]

  • Seite 164

    9- 3 4 Issue 1 S e pt em ber 1995 ■ Never push objects of any kind through the p ower suppl y or dis tr ib utio n unit slots as they may tou c h d a n g erous volt a g e point s o r short ou t parts t h at could r es u lt i n a r i sk of f ire or ele c t ri cal shock. ■ T o r educe risk o f elect ric shock, do n ot disassemb l e t hese produ ct[...]

  • Seite 165

    Install t he M S P-1 Powe r S u p p l y Issue 1 S e p te mb er 1995 9- 3 5 Impo rtant Safety Instru ctions The mo st careful at te nt ion has been d evoted to s afe ty s tandards in th e manufa ct ure o f t his power s up p ly. S af ety i s a major f ac t or in the design o f every power suppl y . Bu t, safet y is your responsibil it y to o . P l e[...]

  • Seite 166

    9- 3 6 Issue 1 S e pt em ber 1995 Descript io n of the M SP-1 P ower Supply The M S P-1 ( W P92 464L1) Power Su p p l y ca n b e u se d to suppl y l ocal p o wer t o A ttendan t Console 302B , I n te g r ate d Services Digit a l Ne t work (I SDN) -T 75 x x, and 85xx series t elep hones conne cted t o a n A T& T D EF I NITY C o m m u ni cati ons[...]

  • Seite 167

    Install t he M S P-1 Powe r S u p p l y Issue 1 S e p te mb er 1995 9- 3 7 5 . P lace th e ad hesive sid e on the to p of the M S P-1 a n d p ress th e strip d o wn so i t a d heres to the surf ace. Do not place the strip on the bottom of the power supp l y w here the rubb e r f e e t ar e l o cated. 6. Caref ully align the fastener surf ace on th [...]

  • Seite 168

    9- 3 8 Issue 1 S e pt em ber 1995 Figure 9-1 5. M SP- 1 Connections for -48V Powered Telep hon es an d their Adjun cts (Excep t the 8102) 3 8 4 9 5 10 1 6 2 7 1. M S P - 1 P ower supply 2. D 8 W cord 3. D4B U c o rd (F or ana l o g t ele p h on es) or D8W c o r d (F o r D ig i t al C o mm u ni c a t io ns Pr ot oc ol (DCP ) a n d In te grat e d S e[...]

  • Seite 169

    Install t he Basi c Rat e Interfa c e ( B R I) Term inati n g R e s istor Issue 1 S e p te mb er 1995 9- 3 9 Figure 9-16. MSP - 1 Connection s for Adju nc ts Conn ected to the 8102 Analog Te lephone Install th e Basic Rate Int er face (BRI) Ter mi nating Resist or A t erminat ing resisto r is always r e quired whe n the Basic R ate Interf ace (BR I[...]

  • Seite 170

    9- 4 0 Issue 1 S e pt em ber 1995 The resistors b a l ance the ca ble pl ant b etwee n the receiver an d the transmit ter on the T-type int erfac e. T he resistor is b uilt in t o the NT1 a nd c a n be one of t hree values, d epen ding o n t h e confi g uration an d the d istan c e from the NT1 to t h e In t e gr a ted Services Digita l Net work (I[...]

  • Seite 171

    Install t he Basi c Rat e Interfa c e ( B R I) Term inati n g R e s istor Issue 1 S e p te mb er 1995 9- 4 1 Figure 9-1 7. 8-Pin Terminating Resistor Adapter (440A4) Clos et Mou nted (110R A1-12) The 110R A 1-12 term inatin g resistor block i s desig ned t o mo u nt in th e te lecommunications wire closet. It consists of 12 (2-pair) circuits a nd p[...]

  • Seite 172

    9- 4 2 Issue 1 S e pt em ber 1995 Figure 9-1 8. Term inating Resis tor Bloc k (110RA1-12) Figure 9 -19 shows t he wiring c onnect ions for the 110RA 1-12 termi nal block. The TN556 Basic R ate I nterf ace ( BR I) switc h p o rt is term inat e d to the bo t to m row C. For point-t o-point applicat ions, th e top row is conne cted t o the blu e stati[...]

  • Seite 173

    Inst all M ult i p o int Ad ap t e r s Issue 1 S e p te mb er 1995 9- 4 3 Figure 9 -19 . T ypical In stallati on o f Term inating Resis t or B lock (110RA1-12) Two termina l B asic Mu l tipoi n t applicat ions are acco m m o dated b y connecti ng row B (outp ut ) to t he second ter m inal co m m on to the mult i p oint c ircuit. Install Mu ltipoint[...]

  • Seite 174

    9- 4 4 Issue 1 S e pt em ber 1995 Figu re No tes: Figure 9-2 0. Diagram of BR851 -B 367A Adapter The 367A A d ap t er (F igure 9 -21) provides f an-out for up to seven terminal s. The 367A is an 8-con ducto r ada p ter a n d is used at t he work l ocat ion for bridging three t o seven terminals. O rder D8 W cord for i n p ut when using the 367A. I [...]

  • Seite 175

    Inst all M ult i p o int Ad ap t e r s Issue 1 S e p te mb er 1995 9- 4 5 Figu re No tes: Figure 9-2 1. Diagram of 367A Basic M ult i poi nt Inst allation D istances Figure 9 -22, Table 9 -11 a nd T a ble 9 -12 provide cabling distances for f an-out of In t e grated Services Digital Ne t work Basi c Rate Int erfac e (I SDN-B R I) m ult ipoint insta[...]

  • Seite 176

    9- 4 6 Issue 1 S e pt em ber 1995 Figure 9-2 2. Basic Multipoint with One Wor k Location Table 9 -11 shows basic mul tipoin t ca bling distances for te rmin als. Tabl e 9 -11. Basic Multipoint Cablin g Distances NUM B ER OF TERM INALS A C 2 1900 ft (579 m) 33 ft (10 m) A B C 1 2 3 4 5 6 1 . T-int erfa c e so ur c e (TN556 ) 2. S a telli te c l oset[...]

  • Seite 177

    Install Power Ad a p t e rs Issue 1 S e p te mb er 1995 9- 4 7 Table 9 -12 shows basic mu l t ipo i n t cabl i ng dist ances to use when the resistor is in a c loset . Instal l Powe r Adap ters The T-type a d a pters cont ain one mo dular p lug an d two modular jacks . The p i gg y back arrangemen t a l lows f or inserti on into a d jacent jacks i [...]

  • Seite 178

    9- 4 8 Issue 1 S e pt em ber 1995 Figu re No tes: 1. T o Private Bran ch Excha nge (P B X) 2. T o P o we r Su p p ly 3 . T o Te le ph one S ta t io n S et Figure 9-2 4. D iagram of 400 B2 Adap ter 40 0 F2 This p i g g y b ack adapter ( F igure 9 -25) provide s auxiliary power from the K S-22911 t o PR 3 of the Alternat e Mark In v e r sio n ( AM I)[...]

  • Seite 179

    Install A uxili a ry Equ i pme nt Issue 1 S e p te mb er 1995 9- 4 9 Figu re No tes: 1. T o Privat e Bran ch Excha nge (PBX) 2. T o P o we r Su p p ly 3 . T o Te le ph one S ta t io n S et Figure 9-2 5. Diagram of 400 F2 Adapter Instal l Auxil iary Equ i pmen t This section describe s h ow to i nstal l auxiliary eq uipmen t th a t may be used w ith[...]

  • Seite 180

    9- 5 0 Issue 1 S e pt em ber 1995 — S tat ion Message D etai led R ecord ing ( S MD R ) ■ As ynchr o nous D ata Unit s ( A DU) — Provide an interf ace bet ween the sys tem data l ine circuit p ack and the c ustomer’s as y n chronous da t a termina ls and host c o m p u t ers. A s yn chronous Data Un its ( ADU) can also be used to p rovide a[...]

  • Seite 181

    Install A uxili a ry Equ i pme nt Issue 1 S e p te mb er 1995 9- 5 1 Figure 9-2 6. Con nec tions for Louds peaker Paging withou t Univers a l Coupler Install L ouds p eaker Pag in g Access Install lou dspe a k er p aging access as f ollows: 1. Det ermine port assignm ent o f p aging z o ne(s) from Loudspeaker Pa ging Form : 2. Conne ct as shown in [...]

  • Seite 182

    9- 5 2 Issue 1 S e pt em ber 1995 Install M u sic -on-H old Ac cess Req uirements An informa tion outlet provide s access t o t h e music source. I f t he m usic source is Federal C om muni ca tions C o mmission ( FCC) registered, the swit c h sid e of the cross- c onnect field is connect ed d irectly to the switc h cabi net. I f the music source i[...]

  • Seite 183

    Install A uxili a ry Equ i pme nt Issue 1 S e p te mb er 1995 9- 5 3 Figure 9-2 7. Mus ic-on -Hold/D ial Dict a tion, Federal Co mmunicat ions Commission (FCC) Registered Equ ipment ( Auxiliary Access ) T R T R 10 11 T R T R 1 2 3 4 5 6 7 8 9 1. Dia l Dic t ation Equi p men t or m usi c S ourc e 2 . Red (R) 3. Gree n ( T) 4. 103A or W a ll Jac k 5.[...]

  • Seite 184

    9- 5 4 Issue 1 S e pt em ber 1995 Install Fed eral C om mun i catio ns Comm i ssion (F CC ) Reg istered Musi c Source T o install Fede ral Communi cati ons Co mmission (FCC) re gistered music source: 1. Det ermine music fea ture p ort assignm en t from Feat ure-R elat ed Syst em Para met ers F orm: 2. Conne ct as shown Figure 9 -27. Install R eco r[...]

  • Seite 185

    Inst all P ro cess or Da t a Mod ules (PDM s ) Issue 1 S e p te mb er 1995 9- 5 5 Figure 9-28. Connec tions for non- Federal Comm unications Co mmission (FCC ) Registered Recorded Ann ouncement/ Dial Dictation ( An alog Ac cess) Install P rocessor Data Mo d ules (P DM s) Req uirements The in t erfa c e bet ween the system and m any t ypes of d ata [...]

  • Seite 186

    9- 5 6 Issue 1 S e pt em ber 1995 Processor Data Mo d ules (P DMs) are connected to TN754B d i g ital line circui t packs and are m ounte d i nd ivid ually or i n a 71 A data m ounti ng . Ot her digit al-line circuit packs m ay be req uired in some c ountri es. Eac h 71A d a ta mount ing c a n cont ain u p t o e ight mo d ule s. This document c ont[...]

  • Seite 187

    Inst all P ro cess or Da t a Mod ules (PDM s ) Issue 1 S e p te mb er 1995 9- 5 7 Figure 9-29 . C o nnections for Proces sor Data Modules (PD Ms ) in Data M oun t ing Connect ion to Ind ivi dual Proc essor Data Mod ules (P DM s) 1. Det ermi ne port assig nm ent of the Proce ssor Data Mo d ule (PDM ) f ro m t he D ata Module F orm: 2 . I ns ta l l t[...]

  • Seite 188

    9- 5 8 Issue 1 S e pt em ber 1995 4. A d minist er a ccordin g t o t h e instructi ons in the fo llowing Uni ted S tates English b ook: ■ DEFI N I TY C o m m u nicat ions Syste m G en eric 3 V2 I mpl ementa tio n , 555-230-655 Figure 9-30. Connec t ions for In dividu a l Process or Data M od ules (PDM) Install Cal l Managemen t System (CM S ) Int[...]

  • Seite 189

    Inst all P ro perty Manage men t Syst em (PMS) In terf ac e Issue 1 S e p te mb er 1995 9- 5 9 op t ion swit ches is co ntai ned i n the 3B2 Messaging Server Installat i on and Main tenance S erv ice Manua l , 58 5-205-110. The Call M anagem ent Syst e m ( C M S) connec tion is illustrat e d b elow. Figure 9-31. Typ ical Call Management S ystem (C [...]

  • Seite 190

    9- 6 0 Issue 1 S e pt em ber 1995 R e fer to t he vendor’s d oc um enta ti o n for connec ting t o the P roperty Manag e ment Syste m (P MS ). T he o p t ion sw i t c hes on the Processor Data Mo d u le (P DM) must b e set in accor d ance w i th t h e req uirement s for t he custo mers Prop erty Managemen t System (PMS). A journal p rinter ca n b[...]

  • Seite 191

    Install Cust om e r-P rovided Termi nal Using Asynchr o nous D ata Unit (ADU) Issue 1 S e p te mb er 1995 9- 6 1 Figure 9-32. Connec t ions to A syn chron ous Data Unit ( AD U) for Data T erminal E qu i pm ent (D TE) Install Cu s tomer-P rovided Terminal Usin g Asynch r on ous Data Un it ( A DU) Req uirements The in t erfa c e bet ween the switch a[...]

  • Seite 192

    9- 6 2 Issue 1 S e pt em ber 1995 3. R efer to F igure 9 -32 for an illust rati on. Instal l Stati o n Message D etail Record i ng (S MDR)/Ca ll De tail Recordin g Unit (CD RU) Interface The in t erfac e bet ween the switc h and S t a t ion M es sag e Det ail R ecording ( S MD R) can b e through a P r o cess or D a ta Mod ule (PDM) , Trunk Dat a Mo[...]

  • Seite 193

    Inst all S tat ion M es sag e Det ail R ecording ( S MD R )/Cal l Detail R ecording Unit (CDRU ) Int erf a c e Issue 1 S e p te mb er 1995 9- 6 3 Inte rface Cabling to Stat ion Message D etail Record i ng (SMDR ) Out pu t Dev ice Figure 9 -33 shows the c a b ling req uired to connect t h e T EL E SE ER u n it , p rint er, or cus tomer-provided data[...]

  • Seite 194

    9- 6 4 Issue 1 S e pt em ber 1995 Figure 9-3 3. S t ation Message Detail Recordin g (SMDR) Cab ling for O n-Prem ises Data Commun ications Equip ment (DCE) from AC Pow ered Single-Carrier Cabinet 2 3 8 4 9 5 10 11 7 7 6 6 6 6 6 6 1 1. 25-pin R S 23 2 c able 2. D i g ita l line ci rc u it p a ck (TN754 ) 3. An alo g li n e ci rc uit p a ck T N746) 4[...]

  • Seite 195

    Inst all S tat ion M es sag e Det ail R ecording ( S MD R )/Cal l Detail R ecording Unit (CDRU ) Int erf a c e Issue 1 S e p te mb er 1995 9- 6 5 Figure 9 -34 shows the connect ions for a remot e host connected by a pr iv ate line. Figu re No tes: Figure 9-3 4. S t ation Message Detail Recordin g (SMDR) Cab ling for Rem ote Host Switc h Settin gs f[...]

  • Seite 196

    9- 6 6 Issue 1 S e pt em ber 1995 21 2 -T yp e Mode m Swi tc h Setti ng S e t t he o ptio n swit ches for th e 212-type mo d em as fo l lows: Implemen t and Ad minist er System Dat a A fter the hardwar e is inst alled and the system i s ac tivate d, the d ata for system and telep hone features can b e admi nistered . T he im p lem entatio n p roced[...]

  • Seite 197

    Issue 1 S e pt em ber 1995 10-1 10 Test Telephones and Other Equipm ent This chap ter describes ho w to test the te leph ones and o ther equi pment . The followin g tests are incl uded in t his chap ter: 1. Ma ke t est calls (single-cab inet swit ch ) 2. Ma ke t est calls ( t wo-cabi net swit c h ) 3. Ma ke t est calls ( three-cabin e t switc h ) 4[...]

  • Seite 198

    Test Tel ephones and Othe r Equip ment 10 -2 Issue 1 S e p t em ber 1995 and W ire Tele phone s an d Ot he r E quipm ent" , a d mi nist er it using the p roced ures in the Unit ed S ta tes Eng lish b o o k, DEFI NI T Y C o m m u n icat ions System Generic 3 Imp l em enta tion, 555-230-655, a nd test i t using th e p roced ures in this chap ter[...]

  • Seite 199

    Ma ke Test Ca lls (T wo-Cabi net S witch) Issue 1 Septe m b er 1995 10-3 Ma k e Te st C all s ( T wo- C ab in et S wit ch ) Descrip tion T o test a t wo-cabine t switc h, you wil l make the foll owing ca lls: ■ Mak e a call from a teleph one as so ciated with a l in e port i n the Processor Port Net work ( P PN) t o a t elep hone associate d with[...]

  • Seite 200

    Test Tel ephones and Othe r Equip ment 10 -4 Issue 1 S e p t em ber 1995 10. Dial the trunk access c ode. Dial to ne is heard . 11. Dial a list e d d i re ctory number (LDN) f or a working tel ephone. R in g back is heard through the earpiece of t he t est t elep hone. 12 . At th e called telep hone, p ick up the rec eiver. Conversation m ust be sa[...]

  • Seite 201

    Ma ke Test Ca lls (T hree-Cabinet Switch) Issue 1 Septe m b er 1995 10-5 ■ Mak e a call from a teleph one as so ciated with a l in e port i n the Processor Port Ne twork (PPN) to a t elep hone associated with a l ine port in th e Expansion Port N e twork1 ( E P N ). ■ Mak e a call from a teleph one as so ciated with a l in e port i n the Proces[...]

  • Seite 202

    Test Tel ephones and Othe r Equip ment 10 -6 Issue 1 S e p t em ber 1995 6. Dial the extensio n num ber of a workin g tel ephone as so cia ted wi th a l ine port in E xpansion P ort Network1 (E PN) . R ingb ack i s h eard through t he earpiece of th e te st telep hone. 7. At t he called telep hone, p ick up t he rec eiver. Conversation m u st be sa[...]

  • Seite 203

    Ma ke Test Ca lls (T hree-Cabinet Switch) Issue 1 Septe m b er 1995 10-7 27. Dial the extensio n num b er of a workin g tel ephone as s ocia ted w ith a l in e port in th e Proce s sor Port N etwork (PPN ) . Ri n g b ack is heard through the earpiece of th e te st telep hone. 28 . At th e called telep hone, p ick up the rec eiver. Conversation m us[...]

  • Seite 204

    Test Tel ephones and Othe r Equip ment 10 -8 Issue 1 S e p t em ber 1995 49 . Dial the liste d direct ory n umb er (LDN) for a working t elep hone . R in g b ack is heard through th e earp iece of th e t est tel ephone. 50 . At th e called telep hone, p ick up the rec eiver. Conversation m ust be satisfa ct ory. 51 . Hang up both telep hones. Test [...]

  • Seite 205

    Test t he S elec tor Console Issue 1 Septe m b er 1995 10-9 Test the Sel ector Console Descrip tion Check t hat a ll selec tor co nso le lamp s are o p erational . Make call to a telep hone in the system . Proce dure 1. O pen f ront panel of att endant console , press and ho ld Test or Self-Test switch. 2. Each row of la m ps on t he sele ct or con[...]

  • Seite 206

    Test Tel ephones and Othe r Equip ment 10 -10 Issue 1 Se p t em ber 1995 6. A t the test te leph one, hang up th e rece iver. 7. On t he a ttendant console , press Nig ht key. 8. Verif y Ni g h t l am p goes dark. Proce dure — Ringi ng Devic e No t Inst al led 1. Connect a sp are 2500-t yp e tel ephon e to th e i n fo r mat ion outlet i nd icate [...]

  • Seite 207

    Test Qu eue W arning In dicat or Issue 1 S e p te mb er 1995 10-11 4. A t the test t elep hone, p ick u p th e rec eiver a nd d ial the num b er associated with a un i for m call d istribution (UCD) o r a di r ec t de partm ent call in g (DDC) group. 5. Verif y t he lam p ligh ts (see the follow ing note) . NO TE: Delay R ecorded A n nouncement i s[...]

  • Seite 208

    Test Tel ephones and Othe r Equip ment 10 -12 Issue 1 Se p t em ber 1995 Test Integrated Ann ouncement Descrip tion The TN750 A nnoun ce m ent circui t p ack pr ov i des th e abi lit y to store mes sa ges. The me ss a g e s c a n b e re corded fr o m t elep hones on- or off-p rem ises and have f lexible message lengt h s. The tel ephone selec te d [...]

  • Seite 209

    Test M usic-on-Hold Issue 1 S e p te mb er 1995 10-13 Test Music-o n-Hold Descrip tion Verif y m usic i s provided t o a held par ty d ur ing any hold i n terval. Proce dure 1. S e l ect a working telep hone as the te st tel ephone. 2. A t the test te leph one, p ick up the receiv er and dial 0 f or th e attend ant console. 3. At a t te ndant cons [...]

  • Seite 210

    Test Tel ephones and Othe r Equip ment 10 -14 Issue 1 Se p t em ber 1995 Proce dure 1. At c ontrol carrier, s et Emerg ency Tr ansfer swit ch(es) to ON p o si tio n. See Note. NO TE: P ull out on S w i t c h es to ove rc ome d eten ts. 2. At e mergency transfer tel ephon e c onnected to th e port n etwo rk be i n g teste d , pick up th e r e ceiver[...]

  • Seite 211

    Test Basic R ate I nterf ace (BR I) Issue 1 S e p te mb er 1995 10-15 3 . R em ot e access personnel e nters test ina ds-link c o mm a n d , termin ates log in , and d isconnects. 4. R emot e access personnel t hen check th e ap pr o priate trouble t icket. T he trouble t icket should show ‘‘IN AD S,n, MINOR ’ ’ in the d escript ion f ield [...]

  • Seite 212

    Test Tel ephones and Othe r Equip ment 10 -16 Issue 1 Se p t em ber 1995 3. Verif y t he extension num ber of the calling te lephone is display ed on th e disp lay of the c a lled telep hone. The extensi on must be c orr ec t. 4 . Hang up bot h telep hones. 5. Call t he B asic Rate Int erface (B R I) test tel ephone fro m th e othe r t elepho ne. T[...]

  • Seite 213

    Issue 1 S e p tem ber 1995 A-1 A Appr o ved Grou nds This chap ter describes the a p proved grounds ap p ropriate for th e sin gle-carr ie r cabin e ts . Defi ni t ion of Ap proved Gro u nd An approved ground i s t h e cl osest accep t a ble medium f or grounding th e building en tr ance protect or, ent rance cable s h ield , o r single-p oint g ro[...]

  • Seite 214

    Approved Grounds A-2 Issue 1 Septemb er 1995 encased ground, o r a ground ring. I f t hese grounds are no t availa ble, the water p i pe ground can be s upp lem ented b y o ne of the foll owing types of grounds: ■ Other l ocal met al u ndergr o und syste ms or struct ures — Local underground structur e s such as t anks and pi ping systems ■ R[...]

  • Seite 215

    Is s ue 1 Sep temb er 199 5 B-1 B Earthquake P r otection Procedures This a p p endix describes earthquake p r o tection ins ta lla tion p roced ures t o perf orm if your site exp eriences earth q uake a ctivity . Use the followi ng proced ures to inst all eart hquake p ro tection for your c a b inet s. Instal l Floor Mo u nti n g t o Attach Cab i [...]

  • Seite 216

    Eart h q u ake P rotecti on P roced ures B-2 Issue 1 S e p tem ber 1995 Figure B-1. Front Mou nting Angl e — Concrete Floor 5. Mo ve th e c ab inet b ack into place and at tach the ca b inet to t he ang le w ith two #12 - 2 4x1/2-i nch ( 1.3 c m ) thread- forming screws. 6. Insert a p encil o r mar ker through holes in the lower back o f th e cab[...]

  • Seite 217

    Install Floor Mount i n g t o Att ach Cabi net t o F loor Issue 1 S e p tem ber 1995 B-3 10 . Attach t h e c a b inet to the front mount i n g a ngle using four #12-24 b y 1/2- inch (1 .3 cm) threa d form i n g screws. 1 1 . I n th e back o f t he c abinet , la y th e stiffener on the b o t t om of the c a b inet , aligning the stif f ener with the[...]

  • Seite 218

    Eart h q u ake P rotecti on P roced ures B-4 Issue 1 S e p tem ber 1995 Instal l Ground P lates on Cab i net Backs The ground plate provide s th e ground connecti on b etwee n c abin ets, p rovides radio freque ncy (R F) radiat ion p r o tection, and also sta bili zes t he cabi nets. A ground pla te is required b etwee n each cab inet ( see F i gur[...]

  • Seite 219

    Inst all Front Plat e s Issue 1 S e p tem ber 1995 B-5 Figu re No tes: Figure B-3. Single-Carrier Cabinet G rou nd Plate, Fron t Plate, and Battery Loca tions 1 2 3 1 . Fron t P late 2. Ba tte ry 3 . Bac k Pl at e ■ Si de V i ew of 2-Cabinets Po r t Ne twork[...]

  • Seite 220

    Eart h q u ake P rotecti on P roced ures B-6 Issue 1 S e p tem ber 1995[...]

  • Seite 221

    Issue 1 S e p tem ber 1995 C-1 C DEFINITY AUDIX System Power Procedur es Man ually P o we r D o wn DEF INI TY AUD IX S ystem A yellow caution s ticker is p l aced on th e switch’s power unit t elling technicians t o shut d o wn the D E F INI T Y A UDIX S ystem prior to p o wering d own the switc h . T o shu t d own the D EFI NI T Y AUDI X s ystem[...]

  • Seite 222

    DEFI N I TY A UDIX S y ste m P ower Procedures C-2 Issue 1 Septemb er 199 5 NO TE: Even t hough th e DEFI N I TY A UDIX S y s t em i s shu tdown, t h e “hear tbeat” in dica tion on the disp lay con ti nues to f lash. NO TE: Up on th e switc h p owering up, D E F INI T Y AU D IX System will au tomat ically reboot. This sequence may show an MD or[...]

  • Seite 223

    Ma nual Po w er U p D EFINI T Y A UDI X System Is s ue 1 Sep temb er 199 5 C-3 Figu re No tes: Figure C-1. DEFIN ITY AUDIX System Manual Power Up DE FINI TY AUDIX System T o power up the DEFI N IT Y A U D IX S y s t e m , d o t h e f o l l owing : 1. Using a poin ted ob ject such a s a p aper clip o r a pen ( d o no t use a p encil), press the Boo [...]

  • Seite 224

    DEFI N I TY A UDIX S y ste m P ower Procedures C-4 Issue 1 Septemb er 199 5 2 . Hold Bo o t/ Shu tdown but to n i n u nti l t he display indicates the me s sag e , BTEST , stead y o n. 3. R elease Boot/ S h u t d own b u t to n. NO TE: D E F IN I T Y AUDIX S ystem takes a p p roxim ately five min utes to power u p . The f o l lowing o c curs du rin[...]

  • Seite 225

    Issue 1 S e p tem ber 1995 D-1 D Countr y Differ ences Unit ed State s to Uni ted Kin g d om and France Terminology Tran slatio ns Cou nt ry-Specific Hard ware The fo llowin g p a ge s co ntai n ta b les of country- s pecific hardw are. P l ease see the ta b le for your country required hard ware. This inf ormatio n is volatile a n d is, there fore[...]

  • Seite 226

    Country Dif f erences D-2 Issue 1 Septemb er 199 5 * P P M me ans Perio d i c Pul se M eteri n g . Table D-1. United States and Canada United S tates & Can a da Tone Detector TN 2182 TN744C TN748D Tone-Cl oc k TN 2 182 TN780 TN768 Call Classifi er TN 744C TN 2182 TN744B R2 MFC Circui t Not Ap pli c able Speech Synthesizer TN 7 25B Announcement [...]

  • Seite 227

    Countr y-S p e cific Ha rd ware Is s ue 1 Sep temb er 199 5 D-3 * P P M me ans Perio d i c Pul se M eteri n g . Announcement TN750 C TN75 0B Auxil iary Trunk TN763 D Analog Di re ct Inward Dia led (DID) Trunk Not Applicable Analog Central Office (CO) Trunk (no PPM *) TN747 B Analog Central Office (CO) Trunk (w/PPM *) Not Applicable 4 Wire T ie Trun[...]

  • Seite 228

    Country Dif f erences D-4 Issue 1 Septemb er 199 5 * P P M me ans Perio d i c Pul se M eteri n g . Digital Ce ntral Offi ce(CO )/Di r e ct Inward Dial ed (DID) T runk Not App licabl e Digital Tie Trun k TN464F TN46 4 E T N 464D TN464C Digital In tegr a ted Ser vi ces Digita l Netwo r k (IS DN) Central Offic e (CO) Trunk TN4 6 4F TN46 4 E TN 464D TN[...]

  • Seite 229

    Countr y-S p e cific Ha rd ware Is s ue 1 Sep temb er 199 5 D-5 * P P M me ans Perio d i c Pul se M eteri n g . Table D- 5. China * P P M me ans Perio d i c Pul se M eteri n g . 4 Wire Di gital Line T N 754B 2 Wire Di gital Line T N 2181 TN213 6 Data L i ne TN 726B China Tone Detecto r TN74 4C TN2182 To ne- Clo ck TN21 82 Call Class ifier TN74 4C T[...]

  • Seite 230

    Country Dif f erences D-6 Issue 1 Septemb er 199 5 * P P M me ans Perio d i c Pul se M eteri n g . Table D-6. Czech Republic, Slovakia, and Ecuador Czech Rep ubl ic & S lovakia Ec uador Tone Det ector T N 744C TN21 82 TN42 0C Tone-Cloc k TN 2182 TN78 0 Call Classifier T N744C TN21 82 TN74 4B R2MFC Circui t Not App licabl e Speech Sy nthes iz er[...]

  • Seite 231

    Countr y-S p e cific Ha rd ware Is s ue 1 Sep temb er 199 5 D-7 NO TE: All systems in France re quire France-sp ecific carriers provided by AT & T G BC S Barph one. * P P M me ans Perio d i c Pul se M eteri n g . ~ Bec o me RON/TR O N w it h m o di f i c at io ns . R2MFC Circui t Not Applicable Not Applicable Speech Sy nthes iz er TN457 Not App[...]

  • Seite 232

    Country Dif f erences D-8 Issue 1 Septemb er 199 5 * P P M me ans Perio d i c Pul se M eteri n g . Table D-8. Greece Gree ce Tone Detector TN744 C TN2 182 T N748D Tone-Cl oc k TN218 2 TN 7 80 T N756 Call Classifi er TN744 C TN2 182 T N744B R2 MFC Circui t Not Applicable Speech Synthesizer TN725 B Announcement TN750 C TN7 50B T N750 Auxil iary Trunk[...]

  • Seite 233

    Countr y-S p e cific Ha rd ware Is s ue 1 Sep temb er 199 5 D-9 * P P M me ans Perio d i c Pul se M eteri n g . Announcement TN750C TN75 0B TN750 Auxil iary Trunk TN763D TN76 3C Analog Di re ct Inward Dia led (DID) Trunk TN753 Analog Central Office (CO) Trunk (no PPM *) TN747B TN46 5 Analog Central Office (CO) Trunk (w/PPM *) Not Applicable 4 Wire [...]

  • Seite 234

    Country Dif f erences D-10 Issue 1 Septemb er 1995 Table D- 10. Hun gary * P P M me ans Perio d i c Pul se M eteri n g . Hung ary Tone Detector TN744 C TN2182 T N748D TN748C Tone-Cl oc k TN218 2 TN780 T N756 Call Classifi er TN744C TN2182 T N744B R2 MFC Circui t TN744C TN2182 T N744B Speech Synthesizer TN725B Announcement TN750 C TN750B Auxil iary [...]

  • Seite 235

    Countr y-S p e cific Ha rd ware Issue 1 Sep tem b er 19 95 D-11 * P P M me ans Perio d i c Pul se M eteri n g . Auxil iary Trunk TN763D TN417 Analog Dire c t Inward Dialed (DID) Trunk TN2139 An alog Central Off ice (CO) T r u nk (no PP M * ) Not Ap p lic able Analog Central Office (CO) Trunk ( w /P P M *) TN2138 4 Wire T ie Trunk T N2140B TN 2140 2[...]

  • Seite 236

    Country Dif f erences D-12 Issue 1 Septemb er 1995 Ta ble D- 1 2. J apa n * P P M me ans Perio d i c Pul se M eteri n g . Japan Tone Detector TN 744C TN21 82 TN7 48D Tone-Cl oc k T N21 82 TN78 0 TN756 Call Classifi er TN744C TN21 82 TN7 44B R2 MFC Circui t Not App licabl e Speech Synthesizer TN725B Announcement TN 750C TN75 0B TN7 50 Auxil iary Tru[...]

  • Seite 237

    Countr y-S p e cific Ha rd ware Issue 1 Sep tem b er 19 95 D-13 * P P M me ans Perio d i c Pul se M eteri n g . Announcement TN75 0C T N750B TN75 0 Auxil iary Trunk TN76 3 D T N763C Analog Di re ct Inward Dia led Trunk (DID) Not Applicable Analog Central Office (CO) Trunk (no PPM *) TN74 7B Analog Central Office (CO) Trunk (w/PPM *) TN465 C T N465B[...]

  • Seite 238

    Country Dif f erences D-14 Issue 1 Septemb er 1995 * P P M me ans Perio d i c Pul se M eteri n g . Digital Ce ntral Offi ce ( CO )/Dire ct Inward Dialed ( DID ) Tr unk T N 464F TN464E TN46 4 D Digital Tie Trun k T N 464F TN4 64E TN46 4D Digital Integ rated Serv i ces Digital Network (ISDN) Central O ffice (CO) Trunk TN464F TN4 64E TN464 D 8 port An[...]

  • Seite 239

    Countr y-S p e cific Ha rd ware Issue 1 Sep tem b er 19 95 D-15 * P P M me ans Perio d i c Pul se M eteri n g . * P P M me ans Perio d i c Pul se M eteri n g . 4 Wire Di gital Line TN754B TN 754B 2 Wire Di gital Line TN2181 TN2 136 TN 2181 TN213 6 Data L i ne TN72 6B T N 726B Table D- 16. Saudi Arabia Saudi Arabia Tone Detector TN 744C TN2182 TN748[...]

  • Seite 240

    Country Dif f erences D-16 Issue 1 Septemb er 1995 Tabl e D-17. Singapore * P P M me ans Perio d i c Pul se M eteri n g . Singap ore Tone Detecto r TN744C TN2182 TN74 8D To ne- Clo ck TN21 82 TN78 0 TN75 6 Call Class ifier TN74 4C TN2182 TN74 4B R2MFC C ircu it TN744C TN2182 TN74 4B Speech Syn thesizer TN72 5B An nounc ement TN750C TN750B TN75 0 Au[...]

  • Seite 241

    Countr y-S p e cific Ha rd ware Issue 1 Sep tem b er 19 95 D-17 * P P M me ans Perio d i c Pul se M eteri n g . Speech Synthesizer TN45 7 TN725B Annou ncement TN75 0C TN750 B TN750 C TN750B Auxili ar y T runk TN76 3D TN763 D TN763C Analog Direct Inward Dia led (DID) Trunk Not Applicable TN753 Analog Central Offic e (CO) Trunk (no PPM *) TN21 47C TN[...]

  • Seite 242

    Country Dif f erences D-18 Issue 1 Septemb er 1995 * P P M me ans Perio d i c Pul se M eteri n g . Tabl e D-19 . U nited Kingdom Uni te d King do m Tone Detecto r TN744 C T N2182 TN420C TN42 0B Tone-Cl oc k TN21 82 T N780 TN419 B Call Classifi er TN74 4C T N2182 TN744 B R2 MFC Circui t Not Applicable Speech Synthesizer TN45 7 Announcement TN75 0C T[...]

  • Seite 243

    Countr y-S p e cific Ha rd ware Issue 1 Sep tem b er 19 95 D-19 Ta ble D- 20. Ve nez uela * P P M me ans Perio d i c Pul se M eteri n g . Venezuela Tone Detector TN744C TN2182 T N748D Tone-Cl oc k TN2182 T N780 TN756 Call Classifi er TN744C TN2182 TN744B R2 MFC Circui t TN744C T N2182 TN744B Speech Synthesizer TN725B Announcement TN750C T N750B TN7[...]

  • Seite 244

    Country Dif f erences D-20 Issue 1 Septemb er 1995[...]

  • Seite 245

    Septe m b er 1995 Issue 1 E-1 E Installing the 9400-Series T el ephones Installi n g the 9400-Series Telephone s The fo llowin g f i g ures provide th e basic i n for mat ion t o install t he 9400-series t elepho nes. ! CAUTION: W hen this p ro duct i s l o cated in a sep arate b uildi ng from th e DEFI NIT Y Co mmunicat ions Syste m, a li ne curre[...]

  • Seite 246

    Inst alli n g th e 9400-Seri es Tel ephones E-2 Septemb er 19 95 Issue 1 NO TE: The 3B IC a n d 3 B E W p rote ctors can be used only for 2-wire install a tions. They cannot be used for 4-wire i nstall ations. These tel epho nes are not for resident ial us e. They are fo r b usiness syst ems a pp lication s o n ly. Use in a reside ntia l environmen[...]

  • Seite 247

    W iring In f ormation S eptember 1995 I ssue 1 E-3 Figure E-2. A Telep hon e Line Jack in a 4-Wire Configuration NO TE: R egard less o f conf i gurati on, all wi ring be tween the switch and the wa ll jack must consist of twisted-pairs. Use the sup p lied l ine cord wi th t he telep hone, or use an AT & T a p proved equiva lent. An 8-wire mo d [...]

  • Seite 248

    Inst alli n g th e 9400-Seri es Tel ephones E-4 Septemb er 19 95 Issue 1 NO TE: Do no t change any setti n g s on the tele phone f o r 2-wi re or 4-wire installat ions. The tel ephone is a ble t o d etect whet her it is in a 2-wire or a 4-wire confi g uration. Di s ta nc e Li mita tio ns The fo l lowin g are the m aximu m d i st ances a llowed b e [...]

  • Seite 249

    W iring In f ormation S eptember 1995 I ssue 1 E-5 Figure E-3. Line, A djunct, and Hand set Cord Routing for Desktop Installat ion on the 940 3 and 94 10 Te l ephon es Figure E-4. Lin e, Adjunct, Hand set, and Expansion Modu le Cord Routing on t he 9434 Telephone 1 . R ou ti ng chan nel for l in e cord and adju nct c ord 2 . LIn e Jack 3 . Adju nct[...]

  • Seite 250

    Inst alli n g th e 9400-Seri es Tel ephones E-6 Septemb er 19 95 Issue 1 Wal l Mountin g Only the 94 0 3 a n d the 9410 can be wal l mount e d, as shown b elow in Fi g ure E-4, Fig ure E -5, Fi g ure E-6, F i gure E-7, a n d Fi gure E -8 . Figu re No tes: 1. Han d R etain er in Pla c e 2 . P r es s to Re l eas e and R e mov e Handset R et ai ner 3.[...]

  • Seite 251

    W all Mount i n g S eptember 1995 Issue 1 E-7 Figu re No tes: 1. Desktop stan d 2. Desk m o unt t ab slot Figure E-6. Rem ovin g the Desktop Stand for W all Moun t ing 2 1[...]

  • Seite 252

    Inst alli n g th e 9400-Seri es Tel ephones E-8 Septemb er 19 95 Issue 1 Figu re No tes: 1. Li ne c o rd rou ti ng c han ne l f or wal l m o un t 2. Li ne ja c k 3 . Ha ndset jac k 4 . Handset cord ro uti ng c hann el Figure E-7. Lin e Cord Routing for Wall Moun t 2 3 1 4[...]

  • Seite 253

    Using th e T est Feat u re S eptember 1995 Issue 1 E-9 Figure E-8. Placing th e Tel e phon e onto Wa l l Jack Mount i ng Studs Usin g the Test Feat ure W hen the t elep hone is init ially p owered up , th e g reen light next to the TE ST b utt on flashes if the t elep hone is not (or not yet) a b le to c o mm unicate wi th th e switch. The ligh t c[...]

  • Seite 254

    Inst alli n g th e 9400-Seri es Tel ephones E-10 Sep temb er 199 5 Issue 1 ■ The b ut to n l i g h ts on yo u r tel ephone go o n (and, if t h e t erminal ha s a disp lay, all the disp lay se gm ent s fill in): — On the 9403, all the l i g hts g o on t oget her. — On the 9410, the l i g hts g o on in two g ro ups, and the d isp lay fills i n [...]

  • Seite 255

    S eptember 1995 Issue 1 F-1 F Wire Co n v ersion Infor mation This a p p endix prov ides s om e wire conversion in format ion th at ma y b e useful when followin g the installation instruction s provid ed i n t his book. Common Wire Col ours Table F -1 l ists c o mmon wires ty p es and colours for p o w er ( A C Mai n s): AWG to SWG Co n ve r sion [...]

  • Seite 256

    W ire Conversion In form ation F-2 S ep tember 1995 Issue 1 ) Tabl e F-2. Stranded Wire Convers ion ( AW G to SW G to metric) Squar e Mill imet ers Num b e r and D iameter of Strands Mil l imeters Corr espo nding AWG 0.014 7 x 0.05 - - 0.035 7 x 0.08 - - 0.047 24 x 0 .05 -- 0.049 1 x 0.25 - - 0.055 7 x 0.10 - - 0.079 10 x 0 .10 28 0.079 7 x 0.12 2 [...]

  • Seite 257

    A W G to S WG Con v ersi o n ( Stran d e d W ire) Septe m b er 1995 Issue 1 F-3 0.37 7 4 8 x 0.1 0 -- 0.38 9 2 2 x 0.1 5 -- 0.44 2 1 x 0.75 -- 0.45 9 2 6 x 0.1 5 -- 0.49 1 1 0 x 0.2 5 -- 0.49 5 7 x 0.30 -- 0.50 3 1 6 x 0.2 0 -- 0.51 5 1 x 0.81 2 0 0.56 3 7 x 0.32 -- 0.59 7 1 9 x 0.2 0 -- 0.63 6 3 6 x 0.1 5 -- 0.75 4 2 4 x 0.2 0 -- 0.78 5 1 6 x 0.2 [...]

  • Seite 258

    W ire Conversion In form ation F-4 S ep tember 1995 Issue 1 Wire Gaug e Compari s on (S ol id C o ndu ct or) Table F-3 p rovi des in f ormation fo r converti ng Ameri can W ire G a u ge ( A W G) to British S ta n d ard W ire Gauge ( Imperia l), in a d d it ion to met ric w i re g a u g e. 3.022 19 x 0 .45 -- 3.142 16 x 0 .50 -- 3.181 45 x 0 .30 -- [...]

  • Seite 259

    W ire Gauge Comp arison (Sol id Conductor) Septe m b er 1995 Issue 1 F-5 Tabl e F-3. Solid Condu ctor Wire Gauge Comp ar ison ( A WG to SWG t o metric ) Diameter (M ils) Gauge Numbers (mm) American Wire Gaug e (A W G ) British Standard Wire Gaug e (Im perial) Metr ic W i re Gau ge 460.1 11.68 4/0 -- - - 432 11.0 -- 5/0 -- 409.6 10.40 3/0 -- - - 400[...]

  • Seite 260

    W ire Conversion In form ation F-6 S ep tember 1995 Issue 1 138 3.50 -- - - 35 128 .5 3.264 8 -- -- 128 3.25 -- 1 0 - - 118 3.00 -- - - 30 116 2.95 -- 1 1 - - 114 .4 2.906 9 -- -- 104 2.64 -- 1 2 - - 101 .9 2.588 10 -- -- 98.4 2.50 -- -- 2 5 92 2.34 -- 13 -- 90.7 2.30 1 1 -- - - 80.8 2.05 1 2 -- - - 80.0 2.03 -- 14 -- 78.7 2.00 -- -- 2 0 72.0 1.83 [...]

  • Seite 261

    W ire Gauge Comp arison (Sol id Conductor) Septe m b er 1995 Issue 1 F-7 28 0.711 -- 2 2 - - 27.6 0.70 -- -- 7 .0 25.3 0.643 22 -- - - 24 0.610 -- 2 3 - - 23.6 0.60 -- -- 6 .0 22.6 0.574 23 -- - - 22 0.559 -- 2 4 - - 20.1 0.511 24 -- - - 20 0.508 -- 2 5 - - 19.7 0.50 -- -- 5 .0 18 0.457 -- 2 6 - - 17.9 0.455 25 -- - - 17.7 0.45 -- -- 4 .5 16.4 0.41[...]

  • Seite 262

    W ire Conversion In form ation F-8 S ep tember 1995 Issue 1[...]

  • Seite 263

    Septemb er 19 95 Issue 1 G-1 G Electrical Code Equivalencies This a p p e ndix l ists e lectrical code in f orma t ion t hat app lies t o c ountries out side o f North A merica. North American Electrical Code In North Ameri ca, the stan dard electrical c o de tha t m ust b e followed is c alled the National E lectrical Co de ( NE C). W hen installi[...]

  • Seite 264

    E l ectrica l Code Eq uivale ncies G-2 Sep tem ber 19 95 Issue 1 : Tabl e G- 1. I nternational Electrical Codes Country E lectrical Code/Regul ations Australi a B elgium China France Germa ny DIN/ V D E Best immu ng en I taly Japan M acedoni a Malaysia Netherlands Spain Thail a nd Unite d K i n g d o m Unit e d S t at es Na tio nal El e ctrical Cod[...]

  • Seite 265

    Septemb er 19 95 Issue 1 H-1 H Option Switch Settings S o me o f the i nterface u nits used bet ween the singl e-carrier and mult i-carrier cabin e ts a n d o t her t ypes of eq uipmen t require spec ific opt ion switch set ti ngs for each a p plica t i on. T h i s sect ion lists the o p t ion swit c h se tti n g s required for modular proce s s or[...]

  • Seite 266

    O p tion Swit ch Set ting s H-2 Sep tem ber 19 95 Issue 1 connected through a mo d ular processor da ta mo d ule serving as the int erf ace link. The op t ion sett i n g s for t he mo dular proce s s or dat a m odule ( MP D M) in t h is a p plication are shown in Table H-1. Mod em Poolin g (Combined ) Opti o n Set ting s Co mbined Modem P ooli ng r[...]

  • Seite 267

    103JR M o d em O p t ion Se tti n g s S eptember 1995 Issue 1 H-3 Tabl e H-3. O ption Switc h Se ttings for 103JR Modem Feature Op t ion Switch Setting S2 Sw itch on CM 1 Contact Se t ting 123 4 5 6 7 R eceive Space Disconnec t Y E S V * -- -- O -- -- -- -- Send Spa ce Disconnec t Y E S T * X - - - -- -- -- -- - Loss of Carrier Disconnec t Y E S S [...]

  • Seite 268

    O p tion Swit ch Set ting s H-4 Sep tem ber 19 95 Issue 1 201CR Modem Op tion Set t ing s W hen the 201C R mo d e m is use d wit h a m odul a r trunk data mo dule , se t th e op tions on t he m odul a r trunk data m odule as shown in Table H-4. O pt ions on the 201CR m o d em are shown in Table H-5. W hen used for mo de m p ooling, al l fa ctory-fu[...]

  • Seite 269

    201CR M o d em O p t ion Se tt ings S eptember 1995 Issue 1 H-5 Tabl e H-5. Option s Switch Settings for 201 CR Modem Option Line Control Board ( TP 1B) Description D esignation Strap In (Vertical) Strap Out (Horizontal) Transm it Line S i gnal Level -4 d Bm ZE * 1, 2,4,8 Switch S e tting Digital Bo a r d (JB4B ) 1 2 345 6 78 Transm i tter Tim i n [...]

  • Seite 270

    O p tion Swit ch Set ting s H-6 Sep tem ber 19 95 Issue 1 202S R M o de m O ptio n S ettings W hen the 202 S R mo d em is used w ith a mo d ular trunk d at a mo dule, set the op tions on t he m odul a r trunk data m odule as shown in Table H-6. O pt ions on the 202S R m odem are shown in T able H-7. W h en use d for mo d e m p ooli n g , all fa c t[...]

  • Seite 271

    202S R M odem O pti on Se t tings S eptember 1995 Issue 1 H-7 Tabl e H-7. Option S witch Set tings for 202SR Modem S4 Sw itch Cont act Setting O n Transmitte r-Rece iver Option Ou tput level dB m Withou t Reverse Channel With Reverse Channel Description Desig nation 1 2 3 4 56712345 67 Tra n sm i t Li ne S i g nal Le ve l Z O * - 4 X X X X XXXXXXXX[...]

  • Seite 272

    O p tion Swit ch Set ting s H-8 Sep tem ber 19 95 Issue 1 Option S3 Sw itch Con tact Setting Description D e sig nation 123456 Tra n sm i t Onl y Y H * Out -- -- O -- -- -- Ec ho S uppress o r E nabl e Y R * Out -- -- -- X -- -- Carri er Con trolle d T urna roun d Y S * I n - -- -- -- -- -O E a rly Cou n tr y Co d e (Data S e t Rea d y ) Indi ca ti[...]

  • Seite 273

    208BR Mo d em O p tion Se ttin g s S eptember 1995 Issue 1 H-9 208BR Modem Op tion Settings W hen the 208B R m odem is used w ith a modular tr unk dat a mod ule, se t the op tions on t he m o dular trun k data m o du le as shown i n T a bl e H-8. Options for the 208BR m o d em are shown in Table H-9. W hen used f or mod em pooling , all fa ctory-fu[...]

  • Seite 274

    O p tion Swit ch Set ting s H-10 Sep t emb er 199 5 Issue 1 Tabl e H- 9 . O p tion Switc h Settings fo r 208BR Modem Option S witch Descrip tion Des i gnation Output Level dBm S1A S1B S 1C S2A Transm it Lin e Signal Level ZE* - 4 DOW N UP D O WN U P Switch O ption Strap Position Co mprom ise Equalizer (4-dB Sl ope) WU * S2 B U p S2 C U p Data Set R[...]

  • Seite 275

    Asynchr o nous 2 12AR Mo de m O p tion Set t ing s S eptember 1995 Issue 1 H-11 Asyn chronous 212AR Mode m Optio n Set ting s W hen the asynchronous 2 1 2AR m odem is us e d with a m odular trunk data module, set the op t ions on the m odul ar trunk dat a modu le a s shown in Tab l e H-10. O p tions on the asynchronous 212AR m o d em are shown in T[...]

  • Seite 276

    O p tion Swit ch Set ting s H-12 Sep t emb er 199 5 Issue 1 Tabl e H-11. Option Switch Settings for Async hronous 212AR Modem Switch Setting Feature Option Description S1 Switch Cont rols 123 T ip, R i ng, Make B usy E* OUT O - - - - Cou nt r y C o d e (CC) In dic ati o n for Anal og L o o p ZF * ON -- -- X Switch C o nt ac ts S2 S5 123456 78912 S [...]

  • Seite 277

    Asynchr o nous 2 12AR Mo de m O p tion Set t ing s S eptember 1995 Issue 1 H-13 Feature O ption D e scription S3 Switch Cont acts 12345678 C B and C F In d i cat ion s A* COMM ON -- - - X -- -- -- -- - - S end Sp ac e Disconnec t T * I N - -- -- -X- -- -- -- - Aut o m a ti c Answer Z H * I N - -- -- -- -X- -- -- - Answer M od e In d i cat ion W * C[...]

  • Seite 278

    O p tion Swit ch Set ting s H-14 Sep t emb er 199 5 Issue 1 Synch ronou s 212AR Mod em Opti o n Set ting s W hen th e synchronous 212AR m od em is used with a mo du lar trunk data m odule (MTDM ), set the o p t io n s on th e mo d ular trunk d a t a m o d ule (MTD M) as shown in Table H-1 0. O p tions on t he syn c hronous 212A R mo d e m are shown[...]

  • Seite 279

    Synchronous 21 2AR M odem Optio n Set tings S eptember 1995 Issue 1 H-15 Tabl e H-12. Option Switch Se ttings for Synch ronous 21 2AR Modem Swit c h Settin g Feature Option Description S1 Switch Cont acts 123 T ip, R i ng, Make B usy E* OUT O - - - - Cou nt r y C o d e (CC) In dic ati o n fo r An alo g L oop ZF * ON -- -- X Switch C o nt ac ts S2 S[...]

  • Seite 280

    O p tion Swit ch Set ting s H-16 Sep t emb er 199 5 Issue 1 Feature O ption D e scription S3 Switch Cont acts 123456 78 C B and C F Indi ca tio ns A* COMM ON -- - - X -- -- -- -- - - S end Sp ac e Disconnec t T * I N - -- -- -X- -- -- -- - Aut o m a ti c Answer Z H * I N - -- -- -- -X- -- -- - Answer M od e Indi ca tio n W * C E O F F - -- -- -- --[...]

  • Seite 281

    Asynchr o nous 2 224A Mo dem Op tion S e ttin g s S eptember 1995 Issue 1 H- 17 Asyn chronous 2224A Mode m Opt i on Set ting s W hen t he as ynch ronous 2224A m odem is used with a m odular t runk d ata m o dule (MTD M ), set t he o p t i on s on t h e mo d ular trunk d a t a mo dule (MT DM) a s sh own in Table H -13. The asynchronous 2224 A modem [...]

  • Seite 282

    O p tion Swit ch Set ting s H-18 Sep t emb er 199 5 Issue 1 Synch ronous 2224A Mod em Opti o n Set ting s W hen the synchronou s 22 24 A modem i s used wit h a mod ular trun k data m odule, set the op ti ons on the mo dular trunk data mod ule as shown in Table H-14. All fa c tory-fu rnished o ptions should be set on the 2 224A mo dem with the f oll[...]

  • Seite 283

    7400A O p tion Setti n gs S eptember 1995 Issue 1 H-19 7400A Option Sett i ngs Determin e if the 7400A will b e int erfa cing w i t h D-lead m od ems or attent ion cont rol m o d e m s. Use T able H-15 to set the o p t ion s to interf ace wi th D l ead mod e ms an d Tabl e H-16 to set the o p tio ns to inte rface with a t ten t ion c o n trol mo de[...]

  • Seite 284

    O p tion Swit ch Set ting s H-20 Sep t emb er 199 5 Issue 1 Notes: 1. S e t s p eed to mat ch remote mo dem. At l east one s peed m ust be set to ON. 2 . S e t to match r e mo te modem . Prin ter Opti on Set t ings Print ers can be used wi th a D E FINI T Y S yst e m G 3 M a na g e m en t T erminal, as journal prin ters f or the ho sp italit y feat[...]

  • Seite 285

    475 Print e r Connecte d to a G3 M a nage me nt T e rminal S eptember 1995 I ssue 1 H-21 475 Print er Connected to a G3 Manage m ent Termin a l The 4 75 p rinter can b e c onnected to a G3 Manage men t Termi nal to p rovide hard copie s of adm i n is tr at ion d a t a. I t can also be used as a n o u tput receiving d evice for stat ion m essage d e[...]

  • Seite 286

    O p tion Swit ch Set ting s H-22 Sep t emb er 199 5 Issue 1 Tabl e H- 17. Option Switch Settings for 4 75 Printer Connected to Managem ent Term i nal or u s ed f or Station M e ssage Detail Recording (SMDR) Section Setti ng Descrip ti o n Switch 1 1 O F F Charact e r Set 2O N 3O F F 4O F F 5 OF F DC1 an d DC3 6 ON Li ne Feed 7 ON P rint Com m and M[...]

  • Seite 287

    475 or 476 P r inte r Used a s J our na l Print er f or H o sp it alit y Feat ur e S eptember 1995 Issue 1 H-23 Switc h 22 1 OF F Baud Rate * 2O N 3O N 4 OF F No t Used Switc h 23 1 ON R S 232 2O F F 3 OF F Use of D SR 4O F F 5O N 6 OF F No t Used Switc h 24 1 OF F S elect D T R T i m in g 2O N 3 O N S e lect R T S T i min g 4O F F 5O F F U s e o f[...]

  • Seite 288

    O p tion Swit ch Set ting s H-24 Sep t emb er 199 5 Issue 1 Tabl e H- 18. Option Switch Settings for 4 75 Printer Connected as S y stem Pri nter Section Setting Des cription Switch 1 1 ON Charact e r Se t 2O N 3 OFF 4O N 5 ON DC1 a n d DC3 6 O F F Line Feed 7 O F F Print Com m and Mod e 8 ON LF o n CR Switch 2 1 O F F Numeric Disp lay o f Zero 2 O [...]

  • Seite 289

    475 or 476 P r inte r Used a s J our na l Print er f or H o sp it alit y Feat ur e S eptember 1995 Issue 1 H-25 Switc h 22 1 O F F Baud Rate * 2O N 3O N 4 O F F N ot Used Switc h 23 1 ON R S232 2 OFF 3 O F F Use of D SR 4 OFF 5O N 6 O F F N ot Used Switc h 24 1 O N S elect D T R T imin g 2O N 3 O F F Se lect R T S T i ming 4O N 5 O N Use of C T S 6[...]

  • Seite 290

    O p tion Swit ch Set ting s H-26 Sep t emb er 199 5 Issue 1 Tabl e H-19 . O ption Switc h Settings for a 475 or 476 Journal P rinter Section Setting Des cription Switch 1 1 O F F Character Se t 2O N 3 OFF 4 OFF 5 O F F DC1 a n d DC3 6 ON Li ne Feed 7 ON Print Comm and Mo de 8 OFF L F o n CR Switch 2 1 O F F Numeric Disp lay o f Zero 2 O F F Buf fe [...]

  • Seite 291

    475 or 476 P r inte r Used a s J our na l Print er f or H o sp it alit y Feat ur e S eptember 1995 Issue 1 H-27 Switc h 22 1 OFF B a u d Rat e 2 OFF 3 OFF 4 O F F N ot Used Switc h 23 1 ON R S232 2 OFF 3 O F F Use of D SR 4 OFF 5O N 6 O F F N ot Used Switc h 24 1 O F F S elect D T R T im ing 2O N 3 ON Se lect R T S T i ming 4 OFF 5 OFF U se o f C T[...]

  • Seite 292

    O p tion Swit ch Set ting s H-28 Sep t emb er 199 5 Issue 1 470 or 471 Prin ter Used as Jou r nal Prin ter for Ho spi tal ity Feat ur e A p rin t er can be connected to th e s witch to provide har d copy of hosp ital i ty relate d d a t a. T able H-21 shows the o p tio n switc h sett i n g s for the 470 or 471 printers w hen they are used i n t his[...]

  • Seite 293

    470 or 471 P r inte r Used a s J our na l Print er f or H o sp it alit y Feat ur e S eptember 1995 Issue 1 H-29 Tabl e H-21. Option S w itch Se ttings for a 47 0 or 471 Journal P rinter Section Setting Des cription Switch 1 1 O F F Character Se t 2O N 3 OFF 4 OFF 5 O F F DC1 a n d DC3 6 ON Li ne Feed 7 ON P rint Comm and Mode 8 OFF L F o n CR Switc[...]

  • Seite 294

    O p tion Swit ch Set ting s H-30 Sep t emb er 199 5 Issue 1 572 Prin ter A 57 2 prin ter c a n fu nctio n a s a G 3 Ma nageme n t Term inal, statio n mess ag e d e tail recording ( S MD R), s y ste m pr int er , or jo urnal printer. The options on the 572 printer are set with f unct ion keys ra t her than d u al in-lin e p ackage swit ches. Figure [...]

  • Seite 295

    572 Print e r S eptember 1995 Issue 1 H-31 2 . I f th e prin ter is to b e used wi th th e G3 Manage me n t T erm i n al, sta tio n me ss a g e d e t ail record ing ( S MD R), o r as a Journal prin ter, set the o p tion s as shown in T able H-22. If th e printer is b eing used as t he system print er, set the op tions as shown in Table H-23. ■ Us[...]

  • Seite 296

    O p tion Swit ch Set ting s H-32 Sep t emb er 199 5 Issue 1 . Tabl e H-22. 572 Printer Used w ith G3 Managem ent Term inal, Station M e ssage Detail Recording (SMDR) or Journ al Prin ter 572 Printer Option Settings Func ti on Fu nction Menu M enu Number Name Number Status 0 1 FORM LENGTH 0 9 11 02 L P I 01 6 03 C P I 01 10 04 LQ or N LQ 01 LQ 0 5 B[...]

  • Seite 297

    572 Print e r S eptember 1995 Issue 1 H-33 9 3 PROTOCOL 03 XON/ XOFF 9 4 STOP B IT 0 1 1 9 5 PARI T Y 0 1 N O NE 96 P B S 01 9600 Tabl e H-22. 572 Printer Used w ith G3 Managem ent Term inal, Station M e ssage Detail Recording (SMDR) or Journ al Prin ter 572 Printer Option Settings Func ti on Fu nction Menu M enu Number Name Number Status[...]

  • Seite 298

    O p tion Swit ch Set ting s H-34 Sep t emb er 199 5 Issue 1 Tabl e H-23. 572 Printer used as Sys t em Print er 572 Printer O ption Se ttings Func ti on Fu nction Menu Men u Number Nam e N umber St at us 0 1 FORM LENGTH 0 9 1 1 02 L P I 01 6 03 C P I 01 10 04 LQ or N LQ 01 LQ 0 5 BUZZER 0 1 O N 0 6 FONT 0 2 FONTCART 0 7 RESOLUTIO N 0 1 14 4 1 1 BUFF[...]

  • Seite 299

    S t at ion Message D etai l Re c ording ( SMDR ) I n te rface O p tion S etti ng s S eptember 1995 I ssue 1 H-35 ■ W hen the f unct ion t o b e changed is r eached, press the O n Li ne but ton. This a c t ivate s the menu (avail able o ption set tin gs) for the f unct ion. Use the Line Feed and Fo rm Feed bu ttons to step thr ough the op t ions f[...]

  • Seite 300

    O p tion Swit ch Set ting s H-36 Sep t emb er 199 5 Issue 1 R e fer to " Int erf ace Cabling to S ta tio n Message Det ail R ecord ing ( SMD R ) Out put Device" on pag e 9 -63 for c on n ection in f ormation . The 475 or 57 2 print ers can be us ed as an ou tpu t r eceiving device for sta tio n me ss a g e d e t ail record ing ( S MD R ).[...]

  • Seite 301

    Audio In for mat ion Exch ange (A UDIX ) I nt erface Op t ion S e ttings for G3i S y stems S eptember 1995 Issue 1 H-37 Audio Information Exch an ge ( AU DI X ) Interface Option Setti ngs for G3i Systems A UDIX i s s om et i mes conne cted t o t he switc h th ro ugh the processor int erface circuit pa ck . The first c ircuit o n th e proces sor int[...]

  • Seite 302

    O p tion Swit ch Set ting s H-38 Sep t emb er 199 5 Issue 1 ! CAUTION: T o prevent damage from s t a tic el ectric ity, always wear an E M C wrist strap (com code 9 00 6 9 8 2 2 6 ) when ha ndling circuit packs or ot her switc h compone nts. Tabl e H-27. S ignaling Form ats for TN7 6 0 Mode T ype E & M Type I S t a n d ard (unpro tecte d) E &am[...]

  • Seite 303

    TN760 Ti e Trunk Circuit Pack O p tion Settin g s S eptember 1995 Issue 1 H-39 Figure H-2. TN 7 60D Tie Trunk Circu it Pack (Compon ent Side) UNPROT PROT SMPLX E&M SMPLX E&M SMPLX E&M SMPLX E&M 4 3 2 1 PORT 4 PORT 3 PORT 2 PORT 1[...]

  • Seite 304

    O p tion Swit ch Set ting s H-40 Sep t emb er 199 5 Issue 1 Tabl e H-29 . TN 7 60D Option Switc h Settings and Administr ation G3 Installa tion Situatio n Set Prot/ Unp rot Optio n Switch Prefe rred Sign aling Format Set E&M/SM PL X Optio n Switch Adm inist e red Port Circumstance T o G 3 Far-End Co-L oc at ed Sys75 /G1 Si mp l ex Simp le x S M[...]

  • Seite 305

    TN464C, D, E , F Op t ion Se tti n g s S eptember 1995 Issue 1 H-41 TN464C , D, E, F Option S ett i n gs The TN464 circui t p ack in terf aces bet ween a 24 or 32 chan nel Cent ral O ffice (CO)/Int egrate d S erv ices D igita l Net work (I SDN) or tie t ru n k an d the Ti m e Division Mul tiplex ( T DM) bus. The TN464C an d T N464D a c t as D i g i[...]

  • Seite 306

    O p tion Swit ch Set ting s H-42 Sep t emb er 199 5 Issue 1 Figure H-3. Select ion o f 75 Ohm and 32 Channel S et tings on TN464 TN464E/ F Op tion Setti n gs The TN464 circui t p ack in terf aces bet ween a 24 or 32 chan nel Cent ral Off ice/Integrate d Serv i ces Dig ital Network (CO / I SDN) o r ti e trun k a n d the Ti me Division Mul tiplex ( T[...]

  • Seite 307

    TN464C, D, E , F Op t ion Se tti n g s S eptember 1995 Issue 1 H-43 S e t th e impe dance and bit r a te as f ollow s : Table H-31. Option Switch Settings on TN464E/F 120 Ohms Tw is te d p air 75 Ohms Coaxial requirin g 88 8A a d a p ter 32 Channel 2.048 me gabits per s econd 24 Channel 1.544 me gabits per s econd[...]

  • Seite 308

    O p tion Swit ch Set ting s H-44 Sep t emb er 199 5 Issue 1 Figure H-4. TN 4 64E/F Op tion Set tings 3 8 4 9 5 10 1 6 2 7 1. B ackpla ne Co nn ectors 2 . 2 4/3 2 Cha nn el Se le c to r 3. 75/ 12 0 Ohm S e lector 4. F aceplate 5. 32 C ha nn el 6. 120 Ohm (shown sele ct ed) 7 . 24 C ha nnel (sho wn s elect ed) 8. 75 Oh m 9. C o n n e c t o r 1 0 . T [...]

  • Seite 309

    Septemb er 1995 Issue 1 I-1 I Referen ces The fo llowin g is a list of DEFI N I TY Ge n eric 3 documen ts i n clud ing a b rief descript io n o f each documen t. T o order copi es , refer to the a d dress on the i nside f ront cover. F or a ddit iona l DE F I NIT Y d o c uments, refer t o the GB C S Publicat ions Cat alog, 555-000-010 availa ble fr[...]

  • Seite 310

    R e ferenc e s I-2 S e p te m b er 1995 Issue 1 bl ock diagrams. T h is d ocument r eflects Generic 3 Version 2 software, but st ill cont ains relevant info rmat ion. Provide s co m p rehensive te chnical descripti on s o f system features a n d paramet ers. In c lude s th e a p plicat ions a n d b enef its, feat ure int eract ions, a d m ini strat[...]

  • Seite 311

    Ba s ic S e p t e m b er 1995 Issue 1 I-3 Provide s d eta iled descriptions o f a ll the m easurement , s tat us, a n d securit y reports avai lable in the sy s tem and is i ntend e d f or a d minist rators who valid ate traffi c r e port s an d evaluat e system perf orma nce. T his docume nt was t itled Syste m R eports for e arlier system s . Inc[...]

  • Seite 312

    R e ferenc e s I-4 S e p te m b er 1995 Issue 1 Provide s p rocedures for a n i ns ta l la t io n techn ician to c onvert an existi n g DEFI N I TY Gene ric 1, Generic 2 , Generic 3 V ersion 1, Generic 3 Version 2, Generic 3 Ve rsion 4, o r System 7 5 R 1 V3 to Gen eric 3 V ersion 4. I ncluded are u p grade consid erations, lists of required hardwa[...]

  • Seite 313

    Call Cente r S e p t e m b er 1995 Issue 1 I-5 Provide s d eta iled o p erat ing inst ruct ions for the system features on each ty pe of voice ter minal . I ncluded are de f ini tio ns of the voice f eatu res a n d user requir ements . Provide s op erat ing pr ocedures for th e Generic 1 Managem en t T erm inal a n d the G3 Management Term inal for[...]

  • Seite 314

    R e ferenc e s I-6 S e p te m b er 1995 Issue 1 The refe rence includes detai led d esc r ip t ions of the call vectoring features, vector managemen t, vector ad m inist rati on, a d junct rou t ing, troub leshooti n g , an d in teract ions with m anagemen t i n fo r ma t ion syst em s (including the Ca ll Managemen t System ). Provide s d eta iled[...]

  • Seite 315

    A pplicat ion Sp ecifi c S e p t e m b er 1995 Issue 1 I-7 Applicat io n Sp ecific The fo llowin g list of d ocumen ts are a pplication s p ecific. R e fer also to the B asic DEFI N I TY d o c u m e nts. Provide s d eta iled d escriptions o f th e difference bet ween features and ad m ini strat ive form s for systems Generi c 2 t o G eneric 3 Versi[...]

  • Seite 316

    R e ferenc e s I-8 S e p te m b er 1995 Issue 1 Provide s p rocedures for i ns tal la t io n , admi nistration, a n d maintenan c e o f the CallV isor LAN Gateway a pplication and is i n t ended fo r sy s te m ad m i nistrators, te lecommunications managers , M anagemen t Inf ormation Sy s tem (MIS) managers, LAN managers , and AT & T p ersonne[...]

  • Seite 317

    A pplicat ion Sp ecifi c S e p t e m b er 1995 Issue 1 I-9 Provide s op erat ing inst ruct ions for the att endant console. Included are descript i ons o f the c o nso le cont rol keys and funct ions, c a l l handli ng, basic sy s tem troubl eshoot in g inform a tion, an d routi ne mai nten ance proce dures. Provides an overview of the fe atures av[...]

  • Seite 318

    R e ferenc e s I-10 Septe m b er 1995 Issue 1[...]

  • Seite 319

    Iss ue 1 Septe mber 1995 AB B-1 ABB Abbreviations A AC Al ternati ng Current ADU Asyn ch ronous Data Unit AMI Alternate M ark Inversion ANSI Amer ican National Stand ard s Institute ( U.S. A.) AWG Amer ican W i re Gauge B BCMS Basic Call Management System BRI Basic Rate Inter face C CAS Centralized Atte n dant Service or Call A c c ounting S y s- t[...]

  • Seite 320

    A bbreviati ons ABB-2 Issue 1 Septem b er 1995 F FCC Federal C o mmu nic ations Commission ( U.S. A. ) G G3MT Generic 3 Manage ment Termin al H HZ Her tz I I/O I n pu t/Output in in c h INAD S Ini tializ a t ion and Adminis tra tion S ys tem ISDN Integrated Servic es Digital Network L LCD Liquid Crystal Display LE D Light Emit ting Diode LS U Loca [...]

  • Seite 321

    A bbreviati ons Iss ue 1 September 1995 ABB- 3 S SCC Single Carrier Cab i net SMDR S t a tion Message De t ail Re co r d in g SP E Switc h Proces sor Element SP ID Service Pr ofile Identi fier SWG S tandard W i re Gauge (Unite d Kingdom) T TDM Ti me Division Mul tiplex er TM Test Mod e TX Term inal t ransmit U UCD Uniform Call Distr ibution UPS Uni[...]

  • Seite 322

    A bbreviati ons ABB-4 Issue 1 Septem b er 1995[...]

  • Seite 323

    Issue 1 S e p t e m b er 1995 IN- 1 IN Ind ex Numeric s 103A wa ll ja c k , 6-7 103JR modem switc h set tings , H-2 1 0 - AWG wire , 4-3 1 10 SYSTIM AX , 2- 2 11 6A E IA gro und iso lat or, install at ion pro cedure , 6-3 2 0 1CR mode m switc h set tings , H-4 2 02SR m od e m switc h set tings , H-6 2 08BR m o dem switc h set tings , H-9 2 12AR m o[...]

  • Seite 324

    Index IN- 2 Issue 1 Septe m b er 1995 power up pro cedure , C- 1 tra d e mark inf ormation , xvii Au s trali a coun t ry code , 7- 8 re quired hardware , D- 3 Autowrap re quired se tt in g for G3MT , 6-6 Aux Co n n o utputs , 9- 11 AUX con nector pin designations , 9-10 , 9-15 au x iliary connec to r ou tp uts , 9- 1 0 au xiliary equipment pin desi[...]

  • Seite 325

    Index Issue 1 S e p t e m b er 1995 IN- 3 system-parameters co un try optio ns , 7-6 system-paramet ers maint e nance , 7- 14 Ch e ck Pa rity, requir ed setting for G3MT , 6- 6 China coun t ry code , 7- 8 re quired hardware , D- 5 circuit breaker , 4-5 circuit pack pin , 9-13 circuit pack c o n f iguratio n test procedu re , 8- 4 test procedu re, c[...]

  • Seite 326

    Index IN- 4 Issue 1 Septe m b er 1995 d e signations au xiliar y leads a t AUX c o nnector , 9-10 , 9- 15 port board and telep h one , 9-13 DID sig n ali n g , H-41 DID trunk proto cols , H- 4 1 wi ring example , 9-5 digita l statio n wir ing exa mp le ( 2-wi re ) , 9-5 digita l t ie t runk , w i ring example , 9-9 direct c o nnect s ystems , 4-19 [...]

  • Seite 327

    Index Issue 1 S e p t e m b er 1995 IN- 5 approve d , 2-8 buildin g stee l f rame , A-1 conc r ete encas e d , A-2 conn ectin g , A- 2 fl oor , A-2 ground plate , B- 4 , F-1 ground rin g , A-2 layout , 2-6 planning , 2-8 ru le s , 2-8 terminal , A- 2 warning , A- 2 water pipe , A-2 H ha rdware f ib e r-opti c , 4- 1 9 re quired b y co u ntr y , D-1[...]

  • Seite 328

    Index IN- 6 Issue 1 Septe m b er 1995 AT control , H-19 D -lead , H- 19 pooling , 6-7 pooling, sw itch sett ings , H- 2 modu l ar plug , 9-3 t runk d a ta modules , H-1 month names table of English , 7-12 moun ting bolts , B- 1 MPDM ( modular proce ssor d at a modules) , H-1 MSHUT messa ge on AU DIX LCD d isp l a y , C- 1 MSP-1 power s u pply , 9-5[...]

  • Seite 329

    Index Issue 1 S e p t e m b er 1995 IN- 7 p ower u p AC-p owered switch, proce dure , 7- 3 AUDIX procedu re , C-1 DC-p ower ed switch, proced ur e , 7-3 P P N cab in e t installi n g , 4-2 printer 475 switch sett ings , H-21 572 option sett ings , H -30 conn ectin g t o G3 MT , 6- 2 journal option sett ings , H-2 1 option se tt ings , H-20 parallel[...]

  • Seite 330

    Index IN- 8 Issue 1 Septe m b er 1995 screens , 8-2 – 8-4 status sy ste m cabinets-all command , 8- 1 3 sti ffener , B-3 Stop Bit, required set ting for G3 MT , 6- 6 Styrofoam, tr a dem ark informati on , xvii SWG wi re conve rsion , F- 1 s witch processing element in te rch a nge tes t procedure , 8-12 test procedu re , 8- 1 1 sw itch sett ings [...]

  • Seite 331

    Index Issue 1 S e p t e m b er 1995 IN- 9 TN219 8 wir in g , 9-13 TN 4 20C circuit p a c k , 7-7 TN 4 64 ci rcuit p a c k , 6-7 option se tt ings , H-41 , H-42 TN 4 65 ci rcuit p a c k , 6-7 TN 7 42 ci rcuit p a c k , 6-7 TN 7 46 ci rcuit p a c k , 6-7 TN 7 47 ci rcuit p a c k , 6-7 TN 7 48 ci rcuit p a c k , 7-7 TN 7 53 ci rcuit p a c k , 6-7 TN 7[...]

  • Seite 332

    Index IN-10 Issue 1 Sep te m b er 1995[...]