Empire Comfort Systems BF-10-2 Bedienungsanleitung
- Schauen Sie die Anleitung online durch oderladen Sie diese herunter
- 20 Seiten
- 0.78 mb
Zur Seite of
Ähnliche Gebrauchsanleitungen
-
Electric Heater
Empire Comfort Systems DV35IN33L
28 Seiten 2.94 mb -
Electric Heater
Empire Comfort Systems RH-50C-1
18 Seiten 0.7 mb -
Electric Heater
Empire Comfort Systems LS-24B2-1
12 Seiten 4.19 mb -
Electric Heater
Empire Comfort Systems LS-18H-1
8 Seiten 3.77 mb -
Electric Heater
Empire Comfort Systems VFSR-16-3, VFSR-18-3, VFSR-24-3, VFSR-30-3, VFSV-16-3, VFSV-18-3, VFSV-24-3, VFSV-30-3, VFSM-18-3, VFSM-24-3, VFSM-30-3
24 Seiten 1.36 mb -
Electric Heater
Empire Comfort Systems BF-10-2
20 Seiten 0.79 mb -
Electric Heater
Empire Comfort Systems DVD32FP3
60 Seiten 3.71 mb -
Electric Heater
Empire Comfort Systems BF-20-2
20 Seiten 0.79 mb
Richtige Gebrauchsanleitung
Die Vorschriften verpflichten den Verkäufer zur Übertragung der Gebrauchsanleitung Empire Comfort Systems BF-10-2 an den Erwerber, zusammen mit der Ware. Eine fehlende Anleitung oder falsche Informationen, die dem Verbraucher übertragen werden, bilden eine Grundlage für eine Reklamation aufgrund Unstimmigkeit des Geräts mit dem Vertrag. Rechtsmäßig lässt man das Anfügen einer Gebrauchsanleitung in anderer Form als Papierform zu, was letztens sehr oft genutzt wird, indem man eine grafische oder elektronische Anleitung von Empire Comfort Systems BF-10-2, sowie Anleitungsvideos für Nutzer beifügt. Die Bedingung ist, dass ihre Form leserlich und verständlich ist.
Was ist eine Gebrauchsanleitung?
Das Wort kommt vom lateinischen „instructio”, d.h. ordnen. Demnach kann man in der Anleitung Empire Comfort Systems BF-10-2 die Beschreibung der Etappen der Vorgehensweisen finden. Das Ziel der Anleitung ist die Belehrung, Vereinfachung des Starts, der Nutzung des Geräts oder auch der Ausführung bestimmter Tätigkeiten. Die Anleitung ist eine Sammlung von Informationen über ein Gegenstand/eine Dienstleistung, ein Hinweis.
Leider widmen nicht viele Nutzer ihre Zeit der Gebrauchsanleitung Empire Comfort Systems BF-10-2. Eine gute Gebrauchsanleitung erlaubt nicht nur eine Reihe zusätzlicher Funktionen des gekauften Geräts kennenzulernen, sondern hilft dabei viele Fehler zu vermeiden.
Was sollte also eine ideale Gebrauchsanleitung beinhalten?
Die Gebrauchsanleitung Empire Comfort Systems BF-10-2 sollte vor allem folgendes enthalten:
- Informationen über technische Daten des Geräts Empire Comfort Systems BF-10-2
- Den Namen des Produzenten und das Produktionsjahr des Geräts Empire Comfort Systems BF-10-2
- Grundsätze der Bedienung, Regulierung und Wartung des Geräts Empire Comfort Systems BF-10-2
- Sicherheitszeichen und Zertifikate, die die Übereinstimmung mit entsprechenden Normen bestätigen
Warum lesen wir keine Gebrauchsanleitungen?
Der Grund dafür ist die fehlende Zeit und die Sicherheit, was die bestimmten Funktionen der gekauften Geräte angeht. Leider ist das Anschließen und Starten von Empire Comfort Systems BF-10-2 zu wenig. Eine Anleitung beinhaltet eine Reihe von Hinweisen bezüglich bestimmter Funktionen, Sicherheitsgrundsätze, Wartungsarten (sogar das, welche Mittel man benutzen sollte), eventueller Fehler von Empire Comfort Systems BF-10-2 und Lösungsarten für Probleme, die während der Nutzung auftreten könnten. Immerhin kann man in der Gebrauchsanleitung die Kontaktnummer zum Service Empire Comfort Systems finden, wenn die vorgeschlagenen Lösungen nicht wirksam sind. Aktuell erfreuen sich Anleitungen in Form von interessanten Animationen oder Videoanleitungen an Popularität, die den Nutzer besser ansprechen als eine Broschüre. Diese Art von Anleitung gibt garantiert, dass der Nutzer sich das ganze Video anschaut, ohne die spezifizierten und komplizierten technischen Beschreibungen von Empire Comfort Systems BF-10-2 zu überspringen, wie es bei der Papierform passiert.
Warum sollte man Gebrauchsanleitungen lesen?
In der Gebrauchsanleitung finden wir vor allem die Antwort über den Bau sowie die Möglichkeiten des Geräts Empire Comfort Systems BF-10-2, über die Nutzung bestimmter Accessoires und eine Reihe von Informationen, die erlauben, jegliche Funktionen und Bequemlichkeiten zu nutzen.
Nach dem gelungenen Kauf des Geräts, sollte man einige Zeit für das Kennenlernen jedes Teils der Anleitung von Empire Comfort Systems BF-10-2 widmen. Aktuell sind sie genau vorbereitet oder übersetzt, damit sie nicht nur verständlich für die Nutzer sind, aber auch ihre grundliegende Hilfs-Informations-Funktion erfüllen.
Inhaltsverzeichnis der Gebrauchsanleitungen
-
Seite 1
16943-5-0806 Page 1 INST ALLA TION INSTRUCTIONS AND OWNER'S MANUAL UNVENTED ROOM HEA TER MODELS BF-10-2 BF-20-2 BF-30-2 EFFECTIVE DA TE AUGUST 2006 W ARNING: If not installed, operated and ma in tai ne d in acc or dan ce wit h th e ma nuf ac tu r - er's instructions, this product could expose you to substances in fuel or fr om fuel combus[...]
-
Seite 2
Page 2 16943-5-0806 SECTION P AGE Important Safety Information ......................................................................................................................3 Safety Information for Users of LP Gas ...................................................................................................... 4 Introduction ..........[...]
-
Seite 3
16943-5-0806 Page 3 THIS IS A HEA TING APPLIANCE DO NOT OPERA TE THIS APPLIANCE WITHOUT FRONT P ANEL INST ALLED. • An unvented r oom heater having an input rating of more than 6,000 Btu per hour shall not be installed in a bathroom. • An unvented r oom heater having an input rating of mor e than 10,000 Btu per hour shall not be installed in a b[...]
-
Seite 4
Page 4 16943-5-0806 Some people cannot smell well. Some people cannot smell the odor of the chemical put into the gas. Y ou must find out if you can smell the odorant in propane. Smoking can decrease your ability to smell. Being around an odor for a time can af fect your sensitivity or ability to detect that odor . Sometimes other odors in the are[...]
-
Seite 5
16943-5-0806 Page 5 Qualified Installing Agency Installation and replacement of gas piping, gas utilization equip - ment or accessories and repair and servicing of equipment shall be performed only by a qualified agency . The term "qualified agency" means any individual, firm, corporation, or company that either in person or through a[...]
-
Seite 6
Page 6 16943-5-0806 W ater vapor is a by-product of gas combustion. An unvented room heater produces approximately one (1) ounce (30ml) of water for every 1,000 Btu (.3KW's) of gas input per hour . Unvented room heaters must be used as supplemental heat (a room) rather than a primary heat source (an entire house). In most supplemental heat app[...]
-
Seite 7
16943-5-0806 Page 7 The gas line can be routed either through the floor or wall. The gas line opening should be made at this time. Location of the opening will be determined by the position of floor joists and the valve and union used for servicing. Gas Supply Check all local codes for requirements, especially for the size and type of gas supply [...]
-
Seite 8
Page 8 16943-5-0806 SRS-18* and SRS-30 Floor Stand Installation 1. Align clearance holes on floor stand with screw holes on bottom of heater , as shown in Figure 5. 2. Attach floor stand to heater with (4) screws provided with floor stand. 3. Connect the gas line. * SRS-18 floor stand can not be used in a bedroom installation. BF-10 must be wall[...]
-
Seite 9
16943-5-0806 Page 9 On Sheet Rock W all 1. After locating mounting holes, drill (4) 5/16" (8mm) diameter holes into the wall. 2. Insert (4) plastic expansion anchors provided into the holes. 3. T ighten (4) #10 x 1" (25mm) screws provided into the plastic expansion anchors. Do not completely tighten screwheads to the plastic expansion anc[...]
-
Seite 10
Page 10 16943-5-0806 T O TURN OFF GAS T O APPLIANCE 1. STOP! Read the safety information above. 2. Set thermostat (gas control knob) to lowest setting. 3. T urn off all electric power to the appliance (if applicable). 4. Push in gas control knob slightly and turn clockwise to "OFF". Do not force. 5. W ait ten (10) minutes to clear out any[...]
-
Seite 11
16943-5-0806 Page 1 1 Piezo Pilot Ignitor Instructions Depressing the ignitor button completely causes a spark to occur at the pilot. T o light the pilot, it is important that the electrode be 1/8" (3mm) from the pilot. The spark must occur at the point the pilot flame hits the thermocouple. On a new installation with air in the gas line, it [...]
-
Seite 12
Page 12 16943-5-0806 The correct flame will be blue and will extend beyond the thermo- couple. The flame will surround the thermocouple just below the tip. A slight yellow flame may occur where the pilot flame and main burner flame meet. Figure 1 1 Oxygen Depletion Sensor Pilot (Figur e 12) When the pilot has a large yellow tip flame, clean t[...]
-
Seite 13
16943-5-0806 Page 13 Glass Removal, Cleaning and Glass Replacement 1. Remove chrome grill from reflector . 2. Slide glass upward to remove glass from chrome grill. 3. Clean glass with a non-abrasive household glass cleaner and warm water . Gas fireplace glass cleaner can also be used. 4. Align glass with rails on chrome grill and slide glass down[...]
-
Seite 14
Page 14 16943-5-0806 1. Spark electrode does not pr oduce spark. a. Spark electrode broken - replace. b. Ignitor wire ma y not be attache d to spa rk elect rode - attach. c. Ignitor wire damaged - replace. d. Piezo ignitor defective - replace. 2. Spark electrode pr oduces spark but pilot does not light. a. No gas to heater - turn on gas. b. PILOT p[...]
-
Seite 15
16943-5-0806 Page 15 INDEX P ART NO. NO. DESCRIPTION INDEX P ART NO. NO. DESCRIPTION 01 13347 C A S I N G S I D E AS S E M B L Y - L E F T (B F - 1 0 ) 01 13348 CASING SIDE ASSEMBL Y - LEFT (B F - 2 0 B F- 3 0 ) 02 SR-090 CASING BACK (BF-10 BF-20) 02 SR-041 CASING BACK (BF-30) 03 R-2313 PIEZO IGNIT OR 04 1 1231 F AN CONTROL BRACKET (BF-10) 05 SR-00[...]
-
Seite 16
Page 16 16943-5-0806 P AR TS VIEW[...]
-
Seite 17
16943-5-0806 Page 17 INST ALLING OPTIONAL BLOWER SRB-18T OR SRB-30T If heater is installed onto the wall, in order to install the optional blower, the heater must be removed from the wall. If heater is installed on SRS-18 or SRS-30 optional floor stand there is adequate access area available to install the optional blower . 1. T urn "OFF"[...]
-
Seite 18
Page 18 16943-5-0806 . . . . P AR TS LIST Wiring The appliance, when installed, must be electrically grounded in accordance with local codes or , in the absence of local codes, with the National Electri- cal Code, ANSI/NFP A 70, if an external electrical source is utilized. This appliance is equipped with a three-prong [grounding] plug for your pro[...]
-
Seite 19
16943-5-0806 Page 19 SER VICE NOTES[...]
-
Seite 20
Page 20 16943-5-0806 Empire Comfort Systems, Inc. 918 Freeburg A ve. Belleville, IL 62220 PH: 618-233-7420 or 800-851-3153 F AX: 618-233-7097 or 800-443-8648 info@empirecomfort.com www .empirecomfort.com[...]