Hearth and Home Technologies NorthStar-NT Bedienungsanleitung
- Schauen Sie die Anleitung online durch oderladen Sie diese herunter
- 72 Seiten
- 11.36 mb
Zur Seite of
Ähnliche Gebrauchsanleitungen
-
Indoor Fireplace
Hearth and Home Technologies SL-750TV-IPI-D
53 Seiten 3.49 mb -
Indoor Fireplace
Hearth and Home Technologies 8000TRLP-OAKIPI
70 Seiten 3.98 mb -
Indoor Fireplace
Hearth and Home Technologies NorthStar-GT
72 Seiten 11.36 mb -
Indoor Fireplace
Hearth and Home Technologies GARNET-MBK
56 Seiten 3.32 mb -
Indoor Fireplace
Hearth and Home Technologies RHW-47
32 Seiten 1.07 mb -
Indoor Fireplace
Hearth and Home Technologies Gas Fireplaces
4 Seiten 1.23 mb -
Indoor Fireplace
Hearth and Home Technologies GO24-IPI-LP
27 Seiten 9.54 mb -
Indoor Fireplace
Hearth and Home Technologies CD4842MILR
76 Seiten 8.38 mb
Richtige Gebrauchsanleitung
Die Vorschriften verpflichten den Verkäufer zur Übertragung der Gebrauchsanleitung Hearth and Home Technologies NorthStar-NT an den Erwerber, zusammen mit der Ware. Eine fehlende Anleitung oder falsche Informationen, die dem Verbraucher übertragen werden, bilden eine Grundlage für eine Reklamation aufgrund Unstimmigkeit des Geräts mit dem Vertrag. Rechtsmäßig lässt man das Anfügen einer Gebrauchsanleitung in anderer Form als Papierform zu, was letztens sehr oft genutzt wird, indem man eine grafische oder elektronische Anleitung von Hearth and Home Technologies NorthStar-NT, sowie Anleitungsvideos für Nutzer beifügt. Die Bedingung ist, dass ihre Form leserlich und verständlich ist.
Was ist eine Gebrauchsanleitung?
Das Wort kommt vom lateinischen „instructio”, d.h. ordnen. Demnach kann man in der Anleitung Hearth and Home Technologies NorthStar-NT die Beschreibung der Etappen der Vorgehensweisen finden. Das Ziel der Anleitung ist die Belehrung, Vereinfachung des Starts, der Nutzung des Geräts oder auch der Ausführung bestimmter Tätigkeiten. Die Anleitung ist eine Sammlung von Informationen über ein Gegenstand/eine Dienstleistung, ein Hinweis.
Leider widmen nicht viele Nutzer ihre Zeit der Gebrauchsanleitung Hearth and Home Technologies NorthStar-NT. Eine gute Gebrauchsanleitung erlaubt nicht nur eine Reihe zusätzlicher Funktionen des gekauften Geräts kennenzulernen, sondern hilft dabei viele Fehler zu vermeiden.
Was sollte also eine ideale Gebrauchsanleitung beinhalten?
Die Gebrauchsanleitung Hearth and Home Technologies NorthStar-NT sollte vor allem folgendes enthalten:
- Informationen über technische Daten des Geräts Hearth and Home Technologies NorthStar-NT
- Den Namen des Produzenten und das Produktionsjahr des Geräts Hearth and Home Technologies NorthStar-NT
- Grundsätze der Bedienung, Regulierung und Wartung des Geräts Hearth and Home Technologies NorthStar-NT
- Sicherheitszeichen und Zertifikate, die die Übereinstimmung mit entsprechenden Normen bestätigen
Warum lesen wir keine Gebrauchsanleitungen?
Der Grund dafür ist die fehlende Zeit und die Sicherheit, was die bestimmten Funktionen der gekauften Geräte angeht. Leider ist das Anschließen und Starten von Hearth and Home Technologies NorthStar-NT zu wenig. Eine Anleitung beinhaltet eine Reihe von Hinweisen bezüglich bestimmter Funktionen, Sicherheitsgrundsätze, Wartungsarten (sogar das, welche Mittel man benutzen sollte), eventueller Fehler von Hearth and Home Technologies NorthStar-NT und Lösungsarten für Probleme, die während der Nutzung auftreten könnten. Immerhin kann man in der Gebrauchsanleitung die Kontaktnummer zum Service Hearth and Home Technologies finden, wenn die vorgeschlagenen Lösungen nicht wirksam sind. Aktuell erfreuen sich Anleitungen in Form von interessanten Animationen oder Videoanleitungen an Popularität, die den Nutzer besser ansprechen als eine Broschüre. Diese Art von Anleitung gibt garantiert, dass der Nutzer sich das ganze Video anschaut, ohne die spezifizierten und komplizierten technischen Beschreibungen von Hearth and Home Technologies NorthStar-NT zu überspringen, wie es bei der Papierform passiert.
Warum sollte man Gebrauchsanleitungen lesen?
In der Gebrauchsanleitung finden wir vor allem die Antwort über den Bau sowie die Möglichkeiten des Geräts Hearth and Home Technologies NorthStar-NT, über die Nutzung bestimmter Accessoires und eine Reihe von Informationen, die erlauben, jegliche Funktionen und Bequemlichkeiten zu nutzen.
Nach dem gelungenen Kauf des Geräts, sollte man einige Zeit für das Kennenlernen jedes Teils der Anleitung von Hearth and Home Technologies NorthStar-NT widmen. Aktuell sind sie genau vorbereitet oder übersetzt, damit sie nicht nur verständlich für die Nutzer sind, aber auch ihre grundliegende Hilfs-Informations-Funktion erfüllen.
Inhaltsverzeichnis der Gebrauchsanleitungen
-
Seite 1
www .heatnglo.com Heat & Glo • NorthStar EP A Fireplace • 480-1081C September 1, 2008 O - T L T ested and Listed by Portland Oregon USA OMNI-T est Laboratories, Inc. C US DO NOT DISCARD THIS MANUAL CAUTION • I m p o r t a n t o p e r a t i n g and maintenance instructions included. • Leave this manual with party responsible for use and [...]
-
Seite 2
Page 2 Heat & Glo • NorthStar EP A Fireplace • 480-1081C September 1, 2008 Rea d this man ual be fore in stall ing or opera ting thi s appl iance. Ple ase re tain this o wner's man ual f or futu re re ference . Con gratu lati on s Congratulations on selecting a Heat & Glo gas appliance - an elegant and clean alternative to wood bur[...]
-
Seite 3
September 1, 2008 Heat & Glo • NorthStar EP A Fireplace • 480-1081C Page 3 Section 1: Listing and Code Approval s A. ApplianceCertication .................... 4 B. MobileHome Approved .................... 4 C. GlassSpecications ...................... 4 D. BTU&EfciencySpecications ............[...]
-
Seite 4
Page 4 Heat & Glo • NorthStar EP A Fireplace • 480-1081C September 1, 2008 September 1, 2008 September 1, 2008 1 Listing an d Code Appro vals A. Appliance Certication Model: NorthStarEPACertied Woodburning Fireplace Laboratory: OMNIT estLaboratories,Inc. Report No: 061-S-40-2 Type: Wood Fireplace Standard: UL127an[...]
-
Seite 5
September 1, 2008 September 1, 2008 Heat & Glo • NorthStar EP A Fireplace • 480-1081C Page 5 EPA Certied: 3.25 grams per hour Efciency: up to 77.8% BTU Output with EPA test fuel: with cord wood: 51,400/hr. 70,000/hr Vent Size: 8 inches Firebox Size: 2.7 cubic feet Max Wood Length: 24 inches Fuel: Cord Wood Shipping Weight: 650 lbs [...]
-
Seite 6
Page 6 Heat & Glo • NorthStar EP A Fireplace • 480-1081C September 1, 2008 September 1, 2008 September 1, 2008 2 Get ting Star te d A. Design and Installation Considerations Draft is the pressure difference needed to vent replaces successfully .Considerationsforsuccessfuldraftinclude: • Prevent[...]
-
Seite 7
September 1, 2008 September 1, 2008 Heat & Glo • NorthStar EP A Fireplace • 480-1081C Page 7 Figure 7.1 Recommended Chimney Locations Recommended Location Marginal Location Location Not Recommended Recommended Location Location NOT Recommended Multi-level Roofs Windward Leeward[...]
-
Seite 8
Page 8 Heat & Glo • NorthStar EP A Fireplace • 480-1081C September 1, 2008 September 1, 2008 September 1, 2008 Figure 8.1 T ypical Fireplace System Not e : Junction b o x should be installed dur ing initial setup NOTE: Illustrations used throughout these instructions reect “typical installations” and ar[...]
-
Seite 9
September 1, 2008 September 1, 2008 Heat & Glo • NorthStar EP A Fireplace • 480-1081C Page 9 Before beginning the installation be sure the following tools andbuildingsuppliesareavailable: Reciprocating saw Framing material Pliers High temp caulking material Hammer Gloves Phillips screwdriver Framing square Flat blade screwdriver[...]
-
Seite 10
Page 10 Heat & Glo • NorthStar EP A Fireplace • 480-1081C September 1, 2008 September 1, 2008 September 1, 2008 3 F raming and C learances A. Selecting Fireplace Location Several options are available to you when choosing a loca- tionfor yourreplace. Thisreplacemay beusedas aroom divider , installed[...]
-
Seite 11
September 1, 2008 September 1, 2008 Heat & Glo • NorthStar EP A Fireplace • 480-1081C Page 1 1 B. Clearances Figure 1 1.1 Clearances to Combustible Materials Fire Risk • Complywithallminimumclearancestocombustiblesasspecied. • Framingornishingmaterialusedonthefrontof,orin[...]
-
Seite 12
Page 12 Heat & Glo • NorthStar EP A Fireplace • 480-1081C September 1, 2008 September 1, 2008 September 1, 2008 12 in. (305mm) 42 in. (1067mm) 43-7/8 in. (1 1 14mm) 24 in. (610mm) 2 in. (51mm) Figure 12.1 Framing the Fireplace Position combustible / non-combustible mantel 60 in. (1524mm) from base of the replace WITHIN ENCLOSURE AREA: Ap[...]
-
Seite 13
September 1, 2008 September 1, 2008 Heat & Glo • NorthStar EP A Fireplace • 480-1081C Page 13 Fire Risk Do not apply combustible nishing materials overanypartofthefrontofthisreplace. • T he me tal r ep la ce fac e m ay on ly be covered with noncombustible materia[...]
-
Seite 14
Page 14 Heat & Glo • NorthStar EP A Fireplace • 480-1081C September 1, 2008 September 1, 2008 September 1, 2008 E. Construct the Chase A chase is a vertical boxlike structure built to enclose the re - place and/or its vent system. V ertical chimneys that run on the outside o[...]
-
Seite 15
September 1, 2008 September 1, 2008 Heat & Glo • NorthStar EP A Fireplace • 480-1081C Page 15 A. Install the Outside Air Kit Thisreplace will operatecorrectly only ifadequate ventila - tionisprovidedtoallowproper drafttothereplacesystem. See Section 2. Using an outside air kit m[...]
-
Seite 16
Page 16 Heat & Glo • NorthStar EP A Fireplace • 480-1081C September 1, 2008 September 1, 2008 September 1, 2008 Risk of Smoke Spillage Outside air inlet must be located to prevent blockage from: • Leaves • Snow/ice • Otherdebris Blockage may cause combustion air starvation. CAUTION Fire Risk[...]
-
Seite 17
September 1, 2008 September 1, 2008 Heat & Glo • NorthStar EP A Fireplace • 480-1081C Page 17 Figure 17.1 Outside Combustion Air Placement Outlet blocked by snow , leaves, etc. NO Garage or combustible liquids storage NO Attic space NO Outlet placed higher than 3 ft below the termination cap NO Use only duct materials specified by manufactu[...]
-
Seite 18
Page 18 Heat & Glo • NorthStar EP A Fireplace • 480-1081C September 1, 2008 September 1, 2008 September 1, 2008 • Level the Fireplace Level the replace side-to-side and front-to-back. Shim with noncombustible material, such as sheet metal, as necessary .Secure the replace(using the pallet mo[...]
-
Seite 19
September 1, 2008 September 1, 2008 Heat & Glo • NorthStar EP A Fireplace • 480-1081C Page 19 NOTE: • Chimney performance may vary . • T rees, buildings, roof lines and wind conditions affect performance. • Chimney height may need adjustment if smoking or overdraft occurs. Chimney must extend beyond combustible roof structure Maintain[...]
-
Seite 20
Page 20 Heat & Glo • NorthStar EP A Fireplace • 480-1081C September 1, 2008 September 1, 2008 September 1, 2008 A. Chimney Requirements V erticaldistancesaremeasuredfromthebaseofthere - place as shown in Figure 20.1. T o determine the chimney components needed to complete yourparticularinstallation,fol[...]
-
Seite 21
September 1, 2008 September 1, 2008 Heat & Glo • NorthStar EP A Fireplace • 480-1081C Page 21 • Mea sure ho w far the chi mney need s to be shi fted to enab le it to avoid the overhead obstacle. See Figure 21.2. Use dimension “A” to determine chimney section required to achieve the needed shift.[...]
-
Seite 22
Page 22 Heat & Glo • NorthStar EP A Fireplace • 480-1081C September 1, 2008 September 1, 2008 September 1, 2008 D. Assemble the Chimney Sections Attach either a straight chimney section or an offset to the top of the replace (depending on your installation require - ment). Chimney sections are locked together by p[...]
-
Seite 23
September 1, 2008 September 1, 2008 Heat & Glo • NorthStar EP A Fireplace • 480-1081C Page 23 F . Install the Ceiling Firestops • M ark an d cut an ope ning in the ceili ng fo r the c eilin g restopbeingused.SeeFigure23.2. • Frame the opening with the same size lumber used in the [...]
-
Seite 24
Page 24 Heat & Glo • NorthStar EP A Fireplace • 480-1081C September 1, 2008 September 1, 2008 September 1, 2008 G. Install the Attic Insulation Shield An insulation shield must be installed when there is a pos- sibility of insulation coming into contact with the factory built chimney system. • Bend th e t ab s at the to p o f t he at tic [...]
-
Seite 25
September 1, 2008 September 1, 2008 Heat & Glo • NorthStar EP A Fireplace • 480-1081C Page 25 Slanted Roofs Flat Roofs Chimney must extend 3 ft (914 mm) above the roof Chimney must extend 2 ft (610 mm) above any portion of the roof within 10 ft (3048 mm) of the chimney Chimney must extend 3 ft (914 mm) above the roof Chimney must extend 2 f[...]
-
Seite 26
Page 26 Heat & Glo • NorthStar EP A Fireplace • 480-1081C September 1, 2008 September 1, 2008 September 1, 2008 Figure 26.1 Ceiling/Attic Construction Fire Risk • Must maintain 2 in. (51 mm) air clearance to insulation and other combustible materials. W ARNING • Mark the Exit Point of the Roof Locate the point[...]
-
Seite 27
September 1, 2008 September 1, 2008 Heat & Glo • NorthStar EP A Fireplace • 480-1081C Page 27 NAIL FLASHING PLA TE CHIMNEY THIMBLE EXTENSION SCREW FLASHING THIMBLE ADJUST ABLE EXTENSION HOLES FLASHING CHIMNEY FLASHING PLA TE NAIL THIMBLE SCREW THIMBLE EXTENSION B. SL-300 Series Ceiling/Roof Thimble 1. Locate the point where the chimney will[...]
-
Seite 28
Page 28 Heat & Glo • NorthStar EP A Fireplace • 480-1081C September 1, 2008 September 1, 2008 September 1, 2008 T ermination Cap Storm Collar Slope Downward T urn-down Drip Edge Chase (Chimney) 2 in. (51 mm) Collar on Chase T op Caulk .018 (26 ga) min. Galvanized Chase T op Figure 28.1 Chase T op Construction 2 in. (51 mm) min. collar 6 in.[...]
-
Seite 29
September 1, 2008 September 1, 2008 Heat & Glo • NorthStar EP A Fireplace • 480-1081C Page 29 Storm Collar Flashing Collar T op of Pipe 14-1/2 in. (368mm) max. 1-1/2 in. (38 mm) min. overlap 2 in. (51 mm) min. Figure 29.1 Installing a TR342 Round T elescoping T ermination Cap 2 in. (51 mm) min. 4-1/2in. (1 14 mm) max. 1-1/2in. (38 mm)[...]
-
Seite 30
Page 30 Heat & Glo • NorthStar EP A Fireplace • 480-1081C September 1, 2008 September 1, 2008 September 1, 2008 7 Accessories A. Fan Replacement Screwdriver Slot Screws Unplug wire harness before removing fan Remove nut and lift out fan Fan Cord Location The NorthStar Fireplace comes standard equipped with two fans, installed at the factory[...]
-
Seite 31
September 1, 2008 September 1, 2008 Heat & Glo • NorthStar EP A Fireplace • 480-1081C Page 31 B. Bafe Removal and Installation 1. Remove all ash from rebox, and extinguish all hot embers before disposal into a metal container . 2. Remove the bafe protection channel by turning[...]
-
Seite 32
Page 32 Heat & Glo • NorthStar EP A Fireplace • 480-1081C September 1, 2008 September 1, 2008 September 1, 2008 This kit is tested and safe when installed in accordance with this installation manual. It is your responsibility to read all instructions before starting installation and to follow these instructions carefully during installation[...]
-
Seite 33
September 1, 2008 September 1, 2008 Heat & Glo • NorthStar EP A Fireplace • 480-1081C Page 33 INST ALLA TION 1. Remove the knockout or cover plate from the top of the replaceanddiscardit.SeeFigure33.1. 2. Cut a 3 in. (76mm) hole in the insulation board as per the dimensions shown in Figure 33.1. Adapter Mounting Plat[...]
-
Seite 34
Page 34 Heat & Glo • NorthStar EP A Fireplace • 480-1081C September 1, 2008 September 1, 2008 September 1, 2008 NOTE: Secure the duct so that clearance to the re - place outer wrap is maintained. T ape all seams with aluminum tape 1-1/4 in. (32mm) minimum width or as specied by local codes.) 10. Seal all the way around the inside of t[...]
-
Seite 35
September 1, 2008 September 1, 2008 Heat & Glo • NorthStar EP A Fireplace • 480-1081C Page 35 E. Timer Assembly Replacement Shock Risk Disconnect power by turning off circuit breaker BEFORE servicing. CAUTION 1. Remove both doors by lifting doors up and off of hinges. 2. Remove the black knob and spring handle. 3. Remove the outside air kno[...]
-
Seite 36
Page 36 Heat & Glo • NorthStar EP A Fireplace • 480-1081C September 1, 2008 September 1, 2008 September 1, 2008 9. There is very little room to pull the timer assembly out the front ofthe replace. P lace your hand through the access door in the oor of the replace. Let the timer asse[...]
-
Seite 37
September 1, 2008 September 1, 2008 Heat & Glo • NorthStar EP A Fireplace • 480-1081C Page 37 Item Description Qty 1 Screw8-32x1/2PHPHL TC 2 2 Screw6-32x1/4PHPHL TC 2 3 W asher SAE #10 2 4 Bushing 2 5 Linkage Control Arm 1 3. Place linkage control arm over timer shaft and tighten set screw . Figure 37.1. [...]
-
Seite 38
Page 38 Heat & Glo • NorthStar EP A Fireplace • 480-1081C September 1, 2008 September 1, 2008 September 1, 2008 8 F inish ing A. Hearth Extension A hearth extension must be installed with all replaces to protect the combustible oor in front of the replace from both radian[...]
-
Seite 39
September 1, 2008 September 1, 2008 Heat & Glo • NorthStar EP A Fireplace • 480-1081C Page 39 Figure 39.1 Positioning the Protective Metal Hearth Strips Fire Risk • MetalhearthstripsMUST be installed. Sparksorembersmayigniteooring. W ARNING Fire Risk • Hearth extensions must be installed exactlyasspec[...]
-
Seite 40
Page 40 Heat & Glo • NorthStar EP A Fireplace • 480-1081C September 1, 2008 September 1, 2008 September 1, 2008 Fascia OuterCan Flange Ember Strip (Seal gap with High temp, noncombustible sealant able to withstand 300°) T ile or Marble Minimum2-1/4in.(57mm)CementBoard orequivalent,(ortwo1/2in.pi[...]
-
Seite 41
September 1, 2008 September 1, 2008 Heat & Glo • NorthStar EP A Fireplace • 480-1081C Page 41 Seal with non-combustible sealant C. Position the Hearth Extension Position and secure the hearth extension over the protective met al s trips that hav e been place d part ial ly und er the repl ace front. These [...]
-
Seite 42
Page 42 Heat & Glo • NorthStar EP A Fireplace • 480-1081C September 1, 2008 September 1, 2008 September 1, 2008 TOOLS NEEDED: Powered drill with #2 Phillips head bit; caulking gun. 1in.(25mm)OVERLAP Metal strips 2 in. (51mm) under edge of Fireplace and Hearth Extension and 2 in. (51mm) on both side of fireplace opening. Nail or scr[...]
-
Seite 43
September 1, 2008 September 1, 2008 Heat & Glo • NorthStar EP A Fireplace • 480-1081C Page 43 Figure 43.1 Mantel Specications 60 in. (1524mm) Mantel Clearances are from bottom of appliance to lower edge of mantel or trim T rim 48 in. (1219mm) F . Mantel A combustible mantel may be positioned no lower than 60 in.(1524mm)fromthe?[...]
-
Seite 44
Page 44 Heat & Glo • NorthStar EP A Fireplace • 480-1081C September 1, 2008 September 1, 2008 September 1, 2008 9 Operating Instr uctions B. General Information Fireplaces, as well as other woodburning appliances, have been used safely for many years. It has been our experience that most problems are caused by improper installation and oper[...]
-
Seite 45
September 1, 2008 September 1, 2008 Heat & Glo • NorthStar EP A Fireplace • 480-1081C Page 45 C. Outside Air A source of air (oxygen) is required in order for combustion totakeplace.Whateverair isconsumedbytheremustbe replaced through cracks around windows, under doors, etc. Most newlyconstructed[...]
-
Seite 46
Page 46 Heat & Glo • NorthStar EP A Fireplace • 480-1081C September 1, 2008 September 1, 2008 September 1, 2008 D. Clear Space Near the Fireplace Combustible materials must not be stored on the hearth ex- tension. Room furnishings such as drapes, curtains, chairs or other combustibles must be at least 4 ft (1219mm) from theopenfront?[...]
-
Seite 47
September 1, 2008 September 1, 2008 Heat & Glo • NorthStar EP A Fireplace • 480-1081C Page 47 CAUTION ALL wiring should be done by a qualied electrician and sha ll be in comp lia nce wi th loc al codes and wi th the Na tio nal Electric Code NFP A/NEC No. 70-current (in the United Sta[...]
-
Seite 48
Page 48 Heat & Glo • NorthStar EP A Fireplace • 480-1081C September 1, 2008 September 1, 2008 September 1, 2008 Fire Risk • DoNOTburnwetorgreenwood. • Store wood in dry location. • Stack wood so both ends are exposed to air . Wet, unseasoned wood can cause accumulation of creosote. W ARNING Fire Risk DoNOTs[...]
-
Seite 49
September 1, 2008 September 1, 2008 Heat & Glo • NorthStar EP A Fireplace • 480-1081C Page 49 Not e : The r st three or fo ur res should be of m oderate size to allow the oils and binder s to be bur ned from t he rep lac e and t he ref ract or y an d paint to cure. Y ou may[...]
-
Seite 50
Page 50 Heat & Glo • NorthStar EP A Fireplace • 480-1081C September 1, 2008 September 1, 2008 September 1, 2008 INCORRECT POSITIONS Ceramic Blanket and Bafe Board are NOT in contactwiththebackoftherebox. Ceramic Blanket is NOT in contact with the back ofthe [...]
-
Seite 51
September 1, 2008 September 1, 2008 Heat & Glo • NorthStar EP A Fireplace • 480-1081C Page 51 L. Burning Process Firerequires3thingstoburn:fuel,airandheat.Ifheat isrobbed fromthereplace duringthedryingstage, the new load of wood has reduced the chances for a good clean [...]
-
Seite 52
Page 52 Heat & Glo • NorthStar EP A Fireplace • 480-1081C September 1, 2008 September 1, 2008 September 1, 2008 P . Opacity T hisis themeasureof howcleanlyyour replaceis burn - ing. Opac ity is measu red in percen t; 100% opac ity is when an object is totally obscured by th[...]
-
Seite 53
September 1, 2008 September 1, 2008 Heat & Glo • NorthStar EP A Fireplace • 480-1081C Page 53 Q. Chimney Fire Intheeventofachimneyre: • Have the chimney and adjacent structure inspected by qualied professionals. Hearth & Home T echnologies recommendsthat NFIor CSIA certied[...]
-
Seite 54
Page 54 Heat & Glo • NorthStar EP A Fireplace • 480-1081C September 1, 2008 September 1, 2008 September 1, 2008 1 0 T rou bleshooting Thisreplace will operatecorrectly only ifadequate ventila - tionisprovidedtoallowproper drafttothereplacesystem. Hearth & Home T echnologies [...]
-
Seite 55
September 1, 2008 September 1, 2008 Heat & Glo • NorthStar EP A Fireplace • 480-1081C Page 55 Another appliance in home also exhausting air (furnace, fan, dryer , etc.)? Air register from furnace near fireplace? Doors opening and closing? Window closed for start-up? Outside air closed? Overhead fan operating? Overhanging tree? Bird's n[...]
-
Seite 56
Page 56 Heat & Glo • NorthStar EP A Fireplace • 480-1081C September 1, 2008 September 1, 2008 September 1, 2008 C. Diagnostics and Problem Solving Diagnostic Question Possible Causes of Condition Solutions Are the air controls open? • No draft • No combustion air Openaircontrols Is there enough paper? Insufcientheattoi[...]
-
Seite 57
September 1, 2008 September 1, 2008 Heat & Glo • NorthStar EP A Fireplace • 480-1081C Page 57 4. I don’t get enough/any heat. What can I do about it? Diagnostic Question Possible Causes of Condition Solutions Howmuchwoodisusedforre? Insufcientfuel Makelargerres How well seasoned is the wood? Condition o[...]
-
Seite 58
Page 58 Heat & Glo • NorthStar EP A Fireplace • 480-1081C September 1, 2008 September 1, 2008 September 1, 2008 1 1 Maintenance and Ser vicing the Fire place A. General Maintenance Inspe ction : Inspect th e sy stem at t he appliance co nnecti on and at the chimney top. Cooler surfaces tend to build creosote deposits quicker , so it is impo[...]
-
Seite 59
September 1, 2008 September 1, 2008 Heat & Glo • NorthStar EP A Fireplace • 480-1081C Page 59 2. Disposal of Ashes Fire Risk. Disposal of Ashes W ARNING • Ashes should be placed in metal container with tight ttinglid. • Do not place metal container on combustible surface. • Ashes should be retained in closed container until all [...]
-
Seite 60
Page 60 Heat & Glo • NorthStar EP A Fireplace • 480-1081C September 1, 2008 September 1, 2008 September 1, 2008 C. Firebrick Replacement The rebox of your replace is lined with high quality rebrick, which has exceptional insulating properties. There is no need to us[...]
-
Seite 61
September 1, 2008 September 1, 2008 Heat & Glo • NorthStar EP A Fireplace • 480-1081C Page 61 D. Care and Cleaning of Plated Surfaces Clean-plated surfaces with vinegar or a glass cleaner before lightingyourrstretopreventpermanentstaining. CAUTION • Do not use polishes with abrasives. It will scratch plated surf[...]
-
Seite 62
Page 62 Heat & Glo • NorthStar EP A Fireplace • 480-1081C September 1, 2008 September 1, 2008 September 1, 2008 Date of Service Performed By Description of Service F . Service And Maintenance Log[...]
-
Seite 63
September 1, 2008 September 1, 2008 Heat & Glo • NorthStar EP A Fireplace • 480-1081C Page 63 1 2 Referen ce Mater ials A. Fireplace Dimensions L K A B C D E F TOP VIEW FRONT VIEW SIDE VIEW NorthStar A B C D E F in 3-1/2 31-1/8 40 37 40-5/16 43-13/16 mm 89 791 1016 940 1024 1 100 G H I J K L in. 6-1/2 9-1 1/16 5-7/8 1 23-1/8 1 1-1/8 mm 165 [...]
-
Seite 64
Page 64 Heat & Glo • NorthStar EP A Fireplace • 480-1081C September 1, 2008 September 1, 2008 September 1, 2008 B. Chimney Components RF370 - Roof Flashing Flat to 6/12 Pitch 12 in. (305 mm) 24-5/8in. (625 mm) 27-3/8in. (695 mm) RF371 - Roof Flashing 6/12 to 12/12 Pitch 12in. (305 mm) 31 in. (787 mm) 24-5/8in. (625 mm) Firestop Spa[...]
-
Seite 65
September 1, 2008 September 1, 2008 Heat & Glo • NorthStar EP A Fireplace • 480-1081C Page 65 AS8 Straight Attic Insulation Shield 24 in. (610 mm) SL3 - Chimney Stabilizer Inside Diameter 8 in. (203 mm) Outside Diameter 10-1/2in. (267mm) 20-3/4in. (527 mm) SL315-SL330 - Offset/Return Inside Diameter 8 in. (203 mm) Outside Diamet[...]
-
Seite 66
Page 66 Heat & Glo • NorthStar EP A Fireplace • 480-1081C September 1, 2008 September 1, 2008 September 1, 2008 Figure 64.1 - NorthStar Fireplace Diagram 27-1/2" 12-3/8" 24" 2.0" Ceramic Blanket 1 3 4 5 6 2 10 12 1 1 9 8 7 14 15 13 Part number list on following page. C. Parts Diagram[...]
-
Seite 67
September 1, 2008 September 1, 2008 Heat & Glo • NorthStar EP A Fireplace • 480-1081C Page 67 D. Service Parts and Accessories Beginning Manufacturing Date: 2-17-03 Ending Manufacturing Date: Stocked at Depot Item Description Part No. Comments Serial Number and Date Exploded View Parts List - Numerical Order 1 Starter Plate Assembly SL1 8 i[...]
-
Seite 68
Page 68 Heat & Glo • NorthStar EP A Fireplace • 480-1081C September 1, 2008 September 1, 2008 September 1, 2008 D. Service Parts and Accessories Beginning Manufacturing Date: 2-17-03 Ending Manufacturing Date: IMPORT ANT : THIS IS DA TED INFORMA TION . When requesting service or replacement parts for your appliance please provide model numb[...]
-
Seite 69
September 1, 2008 September 1, 2008 Heat & Glo • NorthStar EP A Fireplace • 480-1081C Page 69 D. Service Parts and Accessories Beginning Manufacturing Date: 2-17-03 Ending Manufacturing Date: IMPORT ANT : THIS IS DA TED INFORMA TION . When requesting service or replacement parts for your appliance please provide model number and serial numb[...]
-
Seite 70
Page 70 Heat & Glo • NorthStar EP A Fireplace • 480-1081C September 1, 2008 September 1, 2008 September 1, 2008 E. W arranty Policy Hearth & Home T echnologies LIMITED W ARRANTY Hearth & Home T echnologies (“HHT”) and its respective brands extends the following warranty for HHT gas, wood, pellet and electric appliances purchased[...]
-
Seite 71
September 1, 2008 September 1, 2008 Heat & Glo • NorthStar EP A Fireplace • 480-1081C Page 71 HHT’sobligationunderthiswarrantydoesnotextendtodamagesresultingfrom:(1)installation,operationormain - tenance of the appliance not in accordance with the installation instructions; operati[...]
-
Seite 72
Heat & Glo, a brand of Hearth & Home T echnologies 20802 Kensington Boulevard Lakeville, MN 55044 Division of HNI INDUSTRIES Heat & Glo • NorthStar • 480-1081C September 1, 2008 Page 72 CONT ACT INFORMA TION : Please contact your Heat & Glo dealer with any questions or concerns. For the number of your nearest Heat & Glo deal[...]