Microsoft 9.19 Bedienungsanleitung

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200

Zur Seite of

Richtige Gebrauchsanleitung

Die Vorschriften verpflichten den Verkäufer zur Übertragung der Gebrauchsanleitung Microsoft 9.19 an den Erwerber, zusammen mit der Ware. Eine fehlende Anleitung oder falsche Informationen, die dem Verbraucher übertragen werden, bilden eine Grundlage für eine Reklamation aufgrund Unstimmigkeit des Geräts mit dem Vertrag. Rechtsmäßig lässt man das Anfügen einer Gebrauchsanleitung in anderer Form als Papierform zu, was letztens sehr oft genutzt wird, indem man eine grafische oder elektronische Anleitung von Microsoft 9.19, sowie Anleitungsvideos für Nutzer beifügt. Die Bedingung ist, dass ihre Form leserlich und verständlich ist.

Was ist eine Gebrauchsanleitung?

Das Wort kommt vom lateinischen „instructio”, d.h. ordnen. Demnach kann man in der Anleitung Microsoft 9.19 die Beschreibung der Etappen der Vorgehensweisen finden. Das Ziel der Anleitung ist die Belehrung, Vereinfachung des Starts, der Nutzung des Geräts oder auch der Ausführung bestimmter Tätigkeiten. Die Anleitung ist eine Sammlung von Informationen über ein Gegenstand/eine Dienstleistung, ein Hinweis.

Leider widmen nicht viele Nutzer ihre Zeit der Gebrauchsanleitung Microsoft 9.19. Eine gute Gebrauchsanleitung erlaubt nicht nur eine Reihe zusätzlicher Funktionen des gekauften Geräts kennenzulernen, sondern hilft dabei viele Fehler zu vermeiden.

Was sollte also eine ideale Gebrauchsanleitung beinhalten?

Die Gebrauchsanleitung Microsoft 9.19 sollte vor allem folgendes enthalten:
- Informationen über technische Daten des Geräts Microsoft 9.19
- Den Namen des Produzenten und das Produktionsjahr des Geräts Microsoft 9.19
- Grundsätze der Bedienung, Regulierung und Wartung des Geräts Microsoft 9.19
- Sicherheitszeichen und Zertifikate, die die Übereinstimmung mit entsprechenden Normen bestätigen

Warum lesen wir keine Gebrauchsanleitungen?

Der Grund dafür ist die fehlende Zeit und die Sicherheit, was die bestimmten Funktionen der gekauften Geräte angeht. Leider ist das Anschließen und Starten von Microsoft 9.19 zu wenig. Eine Anleitung beinhaltet eine Reihe von Hinweisen bezüglich bestimmter Funktionen, Sicherheitsgrundsätze, Wartungsarten (sogar das, welche Mittel man benutzen sollte), eventueller Fehler von Microsoft 9.19 und Lösungsarten für Probleme, die während der Nutzung auftreten könnten. Immerhin kann man in der Gebrauchsanleitung die Kontaktnummer zum Service Microsoft finden, wenn die vorgeschlagenen Lösungen nicht wirksam sind. Aktuell erfreuen sich Anleitungen in Form von interessanten Animationen oder Videoanleitungen an Popularität, die den Nutzer besser ansprechen als eine Broschüre. Diese Art von Anleitung gibt garantiert, dass der Nutzer sich das ganze Video anschaut, ohne die spezifizierten und komplizierten technischen Beschreibungen von Microsoft 9.19 zu überspringen, wie es bei der Papierform passiert.

Warum sollte man Gebrauchsanleitungen lesen?

In der Gebrauchsanleitung finden wir vor allem die Antwort über den Bau sowie die Möglichkeiten des Geräts Microsoft 9.19, über die Nutzung bestimmter Accessoires und eine Reihe von Informationen, die erlauben, jegliche Funktionen und Bequemlichkeiten zu nutzen.

Nach dem gelungenen Kauf des Geräts, sollte man einige Zeit für das Kennenlernen jedes Teils der Anleitung von Microsoft 9.19 widmen. Aktuell sind sie genau vorbereitet oder übersetzt, damit sie nicht nur verständlich für die Nutzer sind, aber auch ihre grundliegende Hilfs-Informations-Funktion erfüllen.

Inhaltsverzeichnis der Gebrauchsanleitungen

  • Seite 1

    TW AIN Driver Scanner Utility for Microsof t ® Windows ® V ersion 9.18 / 9.19 / 9.21 / 10.10 /10.20 User's Guide P3PC-3942-01ENZ0[...]

  • Seite 2

    i Introduction Thank you for purchasing the "Scanner Utility for Microsoft ® Windows ® ". This software contains a TWAIN-compliant image sca nner driver (simply called "driver" in this guide) and utilities. This guide provides a description summary of the dr iver, as well as a description of the installation method and procedu[...]

  • Seite 3

    ii When "Windows ® 2000," "Windows ® XP," "Windows Server ® 2003," "Windo ws Server ® 2008," "Windows Vista ® " and "Windows ® 7" are referred to collectively, the y are simply referred to as "Windows ® ". Unless otherwise indicated, explanations refer to "Windows ® [...]

  • Seite 4

    iii Organization This manual explains how to install and use this driver, and how to use the TWAIN scanning utility. • Installation This section explains the procedure for insta lling the environments in which this driver may operate. • Using the Driver This section explains how to use the driver. • Using the Gamma Pattern Editor This section[...]

  • Seite 5

    iv Contents 1. Outline .................................................................................................... 1  1.1  Characteristics of this Dr iver .............................................................................. 1  1.2  Operating En vironment ................................................................[...]

  • Seite 6

    v 4.7.1  Rotation ................................................................................................................... 35  4.7.2  Job/Cache ................................................................................................................ 43  4.7.3  Generic ................................................[...]

  • Seite 7

    vi 7. T roubleshooting .................................................................................. 11 3  7.1  Error Messages ............................................................................................. 113  7.1.1  Messages fr om the TWAIN Driver ....................................................................[...]

  • Seite 8

    1 1. Outline 1.1 Characteristics of this Driver • This driver complies with TWAIN regulations V2.1, which are global standards for image scanners. The driver can be used in all TWAIN-compliant applications. • This driver also supports an image scanner th at has the "double-sided scan" function. If the application supports continuous s[...]

  • Seite 9

    2 [USB connection] • A personal computer on which one of the following operating sy stems are installed − Windows ® 2000 − Windows ® XP − Windows ® Server ® 2003 − Windows ® Server ® 2008 − Windows Vista ® − Windows ® 7 *Some models are not supported in Wind ows ® 2000. • USB port • CD/DVD drive (required for installation[...]

  • Seite 10

    3 ◊ Terms related to mouse operation Terms related to major mouse operations are explained below. Click: To press and release the mouse left button Double click: To quickly press the mouse left button twice Drag: Move the mouse while keeping the mouse left button pressed ◊ Notes on operation procedures If some menus need to be operated in a cer[...]

  • Seite 11

    4 2. TW AIN 2.1 TWAIN TWAIN is the specification that defines the st andard software prot ocol and application programming interface (API) for data exchange be tween a software application program and an image input device such as the image scanner. [TWAIN development background] In the past, development of a new scanner inevita bly required the de[...]

  • Seite 12

    5 2.2 TWAIN Application TWAIN mainly applies to the following three software components:  Application software  Source m anager  Source The components are related to each other as shown below. Figure TWAIN Application  Source (Image scanner control of the driver, etc)  Application software (photo retouching software, etc)  Source [...]

  • Seite 13

    6 3. Inst allation 3.1 Preparation 1. Make sure that the operating system (OS) is installed correctly. 2. In case of the SCSI connection, confirm that th e SCSI adapter is connected to your PC and operating correctly. In case of the USB connection, confirm that the USB port is installed in your PC . 3. Confirm that the hard disk that is the install[...]

  • Seite 14

    7 3.2 Installing the Scanner Driver The Windows ® XP screen sample s are shown below. The screen and operations will differ slightly depending on the OS that is being use d. 1. Turn on the scanner. 2. Turn on your PC and Log on to Windows ® . Log on as an administrator. The scanner may be detected automati cally, and the "Found New Hardware [...]

  • Seite 15

    8 In case of Windows Vista ® , Windows Server ® 2008 and Windows ® 7 3. Insert the Setup DVD-ROM or Setup CD-ROM into the disk drive.  <SETUP DISK START UP SCREEN> is displayed. This Dialog is not displayed automatically w hen the "Auto play" setting of the disk drive o n your PC is off. In this case, please run “ AutoPlayer[...]

  • Seite 16

    9 5. Click [TWAIN Driver] (* Depending on the scanner model, the different screen may appear.) Depending on the scanner model, the screen wh ich confirms whether “Error Re covery Guide” and "Image Processing Software Option" are installe d or not is displayed. In this case, click [OK] button, and install Error Re covery Guide. 6. Foll[...]

  • Seite 17

    10 In case of Windows ® XP/ Window s Server ® 2003/ Windows Server ® 2008/ Windows Vista ® / Windows ® 7 1) [Found New Hardware Wizard] is disp layed, click [Next >] button. Following operation is required for Windows Vista ® , Windows Server ® 2008 and Windows ® 7. - The window “Window needs to install driv er software...” will be d[...]

  • Seite 18

    11 2) If [Hardware Installation] is displayed, click [Continue Anyway] b utton. For Windows Vista ® , Windows Server ® 2008 and Windows ® 7, “Windows can’t verify the publisher of this driver software” will appear. Then select “Install this driver software anyway”. For other than Windows Vista ® , Windows Server ® 2008 and Windows ®[...]

  • Seite 19

    12 3.3 Uninstall The uninstall process removes the software and returns the hard disk to its pre-installation state. When you want to remove this scanner driver program from y our PC, uninstall by the following procedures. 1. Turn on your PC and Log on to Windows ® . Log on as an administrator. 2. Close all of the applications on Windows ® 3. Sel[...]

  • Seite 20

    13 4. Using the Driver 4.1 Selecting the Driver To use this driver from the TWAIN applica tion, select "FUJITSU <Product ID>" from the TWAIN data source (driver) selection screen. For general application, the data source selection screen is displayed by selecting the [Select Scanner] or [Acquire .. .] menu. Refer to the instruction [...]

  • Seite 21

    14 4.2.1 Linkage to Image Processing Softw are Option When the “Enable Software IPC” checkbox is marked after installation of “Im age Processing Software Option” (sold separately or included as a standard function)*, there appears setting items of Image Processing Soft ware Option in a part of the Setting Window for TWAIN Driver. (*: Depend[...]

  • Seite 22

    15 4.3 Displaying Driver Information ♦ Image scanner name The model name, option port name, and capacity of in ternal scanner memory (in units of megabytes) of the connected image scanner are display ed. If no image scanner is connected, this field is blank. The type of IPC option board is displayed if an image-processing option board is installe[...]

  • Seite 23

    16 4.4 Setting Information on Image Scanning ♦ Current side When a scanner that allows duplex scanning is used, specifies the page which sets the image scanning information. To scan using the same settings as those for "Front side" and "Back side," clear the checks in the "Individual Setting" checkbox on the "Fr[...]

  • Seite 24

    17 If this checkbox is checked, th e following screen appears. When “Multi Image Output” is selected When “Auto color Detection” is selected - Output mode Multi Image Output One scan outputs both a Color/Grayscale and a Binary B/W image. Auto color Detection Outputs either a Color/Grayscale or a Bi nary B/W image depending on whether the do[...]

  • Seite 25

    18 Primary: Binary Secondary: Color/Grayscale Output images in the order of “Binary B/W image”  “Color/Grayscale image”. - Select Current Side When “Multi Image Output” is selected When “Auto color Detection” is selected Select a side and then set the scanning options for it on the main dialog box accordingly. When scanning in Mu[...]

  • Seite 26

    19 ♦ Resolution Specifies the number of pixels (dots) per inch. Select a predefined resolution or [Custom] from the list. [Customize] enables detail ed settings by a pixel unit. * When you scan documents at a resolution of less than 150 dpi with [Double-page spread], [Clipping (Front)] or [ Clipping (Duplex)] se lected for [Scan Type] , the doubl[...]

  • Seite 27

    20 ♦ Paper Size Specifies a document size for scanning. Select a standard size or [Custom] size ( can be registered up to three) from the list. * When you perform a scan in [Carrier Sheet ] size with [Clipping (Front)] or [Clipping (Duplex)] selected for [Scan Type], the imag e is output in Carrier Sheet size without being cropped. Window for cus[...]

  • Seite 28

    21 Width, Length : To specify a custom paper size, u se the scroll bar or enter the paper size directly. The unit specified in [Option]-[Generic]-[Unit/Scaling] will be applied to the unit in this window. ♦ Scanning Area Specifies the start position, width and length for the image scan. The maximum allowable size is the paper size selected previo[...]

  • Seite 29

    22 This option can be used only for scanner models that support duplex scanning. The "Duplex Function" requires that the calli ng application supports "continuous scan." If the application does not support "continuous scan," only the data for the front side of the page is passed to the application. Some scanner models [...]

  • Seite 30

    23 * The "Long page" is not displayed in the [S can Type] dropdown list if not supported by the device. See "Relevant Image Sca nner Specification" in the Appendix. * When the scan size is increased, more me mory space is consumed. If a scan cannot be performed due to insufficient memory, refer to “ Insufficient memory. (DS410[...]

  • Seite 31

    24 ♦ Image Mode Selects an image mode for scanning the image. Select a corresponding image mode from the list. Black & White Scans data by using the fixed threshold binar y , black-and-white. Distinguishes black from white by the setting in the "Threshold" of "Scanning Parameter". This scanning mode is suitable for scannin[...]

  • Seite 32

    25 256 Color Scans data using 256 colors. Data size is smaller than "24 bit Color" selected. Please note that the image quality of "256 Color (8 bit)" is inferior to the case of "24 bit Color ". Choose "24 bit Color" for higher quality. Only color scanner models support this option. See "Relevant Image S[...]

  • Seite 33

    26 ♦ Halftone Select the halftone pattern for halftone scanning from the built- in pattern list. Select the desired halftone pattern for disp laying the obtained image. This setting is effective when "Halftone", "Automatic Separation" or "SEE (Selective Edge Emphasis)" is selected in "Image Mode". Some scan[...]

  • Seite 34

    27 ♦ Scanning Parameters For fine scan adjustments. Since there is no fixed set of values, set by trial and error. ◊ Brightness: Sets the brightness of the overall image. Specify the brightness with a number in th e range of 1 (bright) to 255 (dark). To darken the overall image, increase the valu e of the setting. To brighten the overall image,[...]

  • Seite 35

    28 ♦ Prescan While viewing the scanned image on the screen, settings such as brightness and contrast of the scanned image can be finely adjusted. When performing a scan with the [Prescan] checkbox selected, [Image Adjustment Screen] appears after the first page is scanned. * This function cannot be used when [Mu lti Im age Output], [Auto Color De[...]

  • Seite 36

    29 ◊ Threshold : Threshold is the criterion that distinguishes black and white colors in B&W im ages. The setting range is from 1 (bright) to 255 (dark). To scan light gray as black, increase the setti ng value. To avoid scanning any unwanted gray, decrease the setting value. ◊ Contrast : Sets the contrast of the scanned image. The setting [...]

  • Seite 37

    30 ◊ [Restore Default] button Restores the scanner parameter setting values back to what they were when the screen was turned on. ◊ [Continue] button Continues scanning using the adjusted scanning parameters. ◊ [Quit] button Saves the adjusted scanning parameters and stops scanning.[...]

  • Seite 38

    31 4.5 Specifying Driver Operation ♦ [Preview] Scans in a preliminary image based on set values, and displays the image in the preview window. Before actual scanning, the preview function can be us ed to display the entire document for specifying the desired scan area. In case of the scanner with Flatbed basically, th e preview function is availa[...]

  • Seite 39

    32 ♦ [Reset] Restores the current setting values to the stat us immediately after the window is opened. ♦ [Help] Displays online help. When the [F1] key is pressed, help information regarding the item on which the cursor is placed is displayed. Note. Depending on the applicat ion used help information may not be displayable with the [F1] key. T[...]

  • Seite 40

    33 4.6 Setting "Scanning Area" Specify the scanning area in the preview window as follows: Setting: 1. Press the left mouse button to specify the origin (top left corner) of the scanning area. (The cursor appears as a "+".) 2. Drag the mouse to show the outline of th e scanning area. (As the cursor m oves, a range frame is shown[...]

  • Seite 41

    34 4.7 Setting Options The "option dialog" is used to set device-specific functions and the item s that differ depending on whether the scanner used supports them. The option specification is divided into "Rotation", "J ob/Cache", "Generic", "Imprinter (Endorse)" , "Start Up", “Filter”[...]

  • Seite 42

    35 The options are described below: 4.7.1 Rotation (For V9.18 / 9.19 / 9.21 / 10.20) (For V10.10) Figure Option dialog (Rotation)[...]

  • Seite 43

    36 ♦ Flip Side Rotation Specifies the binding of the document when both sides are scanned using ADF. Book Outputs the scanned image for both sides as is. Select this option to scan documents bound on the left or right side Fanfold Outputs the scanned image of the backside rotated 180 degrees. Select this option to scan documents bound on the top [...]

  • Seite 44

    37 ♦ Rotation Degree Outputs the scanned image rotated to the right or left 90 degrees. 0.0 degree Outputs the scanned image as is. 90.0 degree Outputs the scanned image rotated 90 degrees to the right (clockwise). -90.0 degree Outputs the scanned image rotated 90 degrees to the left (counterclockwise). 180.0 degree Outputs the scanned image rota[...]

  • Seite 45

    38 * The image orientation may not be corrected properly depending on the driver setting at scanning. * If you cannot correct the image orientation properl y , use the Edge Emphasis function of the driver to correct it. * This function does not work properly for some applications. ♦ Punch hole removal Holes punched along the binding side are dete[...]

  • Seite 46

    39 Automatic Size and Skew detection Disable This option outputs the image as it was scanned. End of Page Detection Scanning with the ADF and page length detec tion selected will output data for the page size detected. The image data output will adjust to the page length detected for each page inclu ding smaller size pages. Data cannot be output fo[...]

  • Seite 47

    40 White Background Use it to activate "Overscan". Both [White Background] and "Overscan" need to be selected for making Overscan effective. If "Overscan" is not selected, [White Background] functions the same as [Disable]. This option may not be supported for some scanners. See "Relevant Image Scanner Specificati[...]

  • Seite 48

    41 The output order of the back side images scanned in Duplex mode. When "Book" is selected under [Flip Side Rotation] Third page : The upper half on the back side Fourth page : The lower half on the back side When "Fanfold" is selected under [Flip Side Rotation] Third page : The lower half on the back side Fourth page : The upp[...]

  • Seite 49

    42 * This option may not be supported for some scanners. See "Relevant Image Scanner Specification" in the Appendix. Note. When [Double-p age spread] is selected, Option di alog (Rotation) is not displayed. (V9.21)[...]

  • Seite 50

    43 4.7.2 Job/Cache Figure Option dialog (Job/Cache) ♦ Caching Specifies whether to pre-read (cache) when a document is scanned. This option enables faster scanning. If processing of the application being used sl ows down and scanning stops, this option can be used to prevent degradation of the scanning speed. (The effect, h owever, depends on the[...]

  • Seite 51

    44 Ram cache Prereads the allowable amount based on the allocated memory size and stores the data in PC memory. A memory size between 1 and 200 MB can be set. Use Memory on Scanner Pre-reads using the memory installed in the scanner (displayed only if supported by the scanner). Use Both Memory Pre-reads using memory of both Scanner and PC (displaye[...]

  • Seite 52

    45 ♦ Multifeed Detection This option detects a multifeed (occurs when two or more documents are sent) based on the set condition. If a multifeed is detected when this setting has been turned on, the device will stop and an error message output. However, when [Double-page spread], [Croppi ng (Front)] or [Cropping (Duplex)] is selected, an error me[...]

  • Seite 53

    46 ♦ Show Multifeed Image Views the image where a multifeed is detected . You can specify either to stop or to continue the scanning. * Depending on the settings during scanning, the image on the show multifeed image window may be different than output the image. OK Scans the displayed image as the scanning image. Scanning continues. Rescan Suita[...]

  • Seite 54

    47 ♦ Pre-Pick It specifies whether a document is picked and carried in front of the scanning position before starting scanning operation at the ADF scanning. This function cannot be used when [Double-pa ge spread] , [Clipping (Front)] or [Clipping (Duplex)] is selected. (V9.21, V10.20) Disable Pre-Pick is not performed. A document is picked and c[...]

  • Seite 55

    48 Some scanner models do not support this function. See "Relevant Image Scanner Specification" in Appendix. ♦ Blank page skip This option skips blank pages (blank pa ges or completely black pages) during ADF continuous scanning. Marking this check box, this function is enabled. *This function can be used if “Ram cache” or “Use Bo[...]

  • Seite 56

    49 <If blank page skip does not operate properly> − If a blank page is scanned, increase the value set. − If scanning is skipped up to the required document, decrease the value set. This function is available only when "Ram cache" or "Use Both Memory" is selected as "Caching" setting. * 1: This percentage rep[...]

  • Seite 57

    50 4.7.3 Generic Figure Option dialog (Generic) ♦ Unit/Scaling This option selects the unit for the scanning area and preview window. One inch is calculated as 25.4 millimeters. When inches are converted to millimeters, values are rounded off. Note. The TWAIN specifications require that the data width be arranged in units of 32 bits. As a result,[...]

  • Seite 58

    51 4.7.4 Imprinter (Endorse) Figure Option dialog (Imprinter) ♦ Enable Imprinter (Endorse) Specifies enabling or disabling the imprinter function of the device. When the option is selected, the scanned doc uments are imprinted according to the instructions below. This applies only to the imprinter option. Ther efore, the function is supported onl[...]

  • Seite 59

    52 * [Pre-Imprinter] and [Post-Imprinter] cannot be used at the same time. Frontside Imprinter (Printing after scanning, and on the front side of docum ents) Prints on documents using the frontside imprinter. In this case, it prints on the front side of the document after scanning. Therefore, the printing is not included in the scanning result. Bac[...]

  • Seite 60

    53 ♦ Bold The imprinter string is outputted with bol d font. Available settings vary depending on your scanner. Refer to “Relevant Image Scanner Specification” in the Appendix. ♦ Initial Value (Counter) Designates the initial count when the Imprinter St ring is set, including a counter value. See the "Relevant Image Scanner Specificati[...]

  • Seite 61

    54 The following definitions can be used. They may also be selected from the menu, which is displayed by clicking on " ". %YYYY : The y ear is printed in four digits using the Western calendar. %YYY: The year is printed using t he two dig its of the Japanese calendar (current, or Heisei era). %YY: The year is printed in the last two digit[...]

  • Seite 62

    55 Note. ・ When scanning in Duplex mode with this setti ng enabled, the digital endorser only prints on the front side of the document. ・ This setting cannot be enabled when Multi Image Ou tput, Auto Color Detection or Split Image is specified. ・ This setting synchronize s the default endorser strings of imprinter and digital endorser. When e[...]

  • Seite 63

    56 4.7.5 Start Up Set up the Po wer Mode, Low-Speed Feeding and Scanner Operation Panel. In some scanner models, displayed dialog bo x or setup item may be different or even [Startup] dialog box ma y not be displayed. In case of model fi-5110C / fi-5120C / fi-5220C / fi-5530C / fi-5530C2 Figure Option dialog (Start Up) In case of model fi-5015C Fig[...]

  • Seite 64

    57 In case of model fi-5750C Figure Option dialog (Start Up) In case of model fi-5650C Figure Option dialog (Start Up)[...]

  • Seite 65

    58 In case of model fi-5900C / fi-5950 Figure Option dialog (Start Up) In case of model fi-6130 / fi- 6140 / fi-6230 / fi-6240 Figure Option dialog (Start Up)[...]

  • Seite 66

    59 In case of model fi-6670(A) Figure Option dialog (Start Up) In case of model fi-6770(A)/6750S Figure Option dialog (Start Up)[...]

  • Seite 67

    60 In case of model fi-6110 Figure Option dialog (Start Up) In case of model fi-6800 Figure Option dialog (Start Up)[...]

  • Seite 68

    61 ♦ Power Mode Quick Start Mode This mode keeps the lamp on regardless the scanner’s operating condition, which saves times for lamp to become steady. Low Power Mode To save the power consumption, this mode turns the lamp off, if the scanner is not operated for 14 minutes. ♦ Enable Low Speed Feeding This is to specify to obtain a high qualit[...]

  • Seite 69

    62 This setting is valid when both “Enable S canner Panel” and this checkbox are checked. With this density dial, the density can be set by five levels. If moving the density dial to the UP direction, the density changes [N ormal] >>[Darker scanning]>>[Dark scanning]. If moving the densit y dial to the Down direction, the density ch[...]

  • Seite 70

    63 4.7.6 Filter Set the filter processing in this dialog. The filter name is displayed in the list box. While checking the checkbox in the left of the filter name, the filter processing is applied to scanned image. When selecting a filter name and clicking [Propert y] button, the setting dialog of the filter is displayed. This function cannot be us[...]

  • Seite 71

    64 Color Select a color to paint over the image frame. Can select "White" or "Black". Please specify either white or black to matc h the background color of the document. Filled Area • [Unit] Select a unit from “Inches”, “Millimeters”, and “Pixels” • [Up], [Down], [Left], [Right] Specify the paint area from each [...]

  • Seite 72

    65 Printing Specify the beginning position of the character string to out put on the scanned image data. X Offset: Specify the position of the width directio n from the left end of document. Y Offset: Specify the position of t he length direction from the top of document. Unit: Select either “mm” or “inch” as the unit of offset value. Count[...]

  • Seite 73

    66 %HH: The hour is printed usi ng two digits of the 24-hour clock; f or example, 08 for 8:00 a.m. an d 14 for 2:00 p. m. %H: The hour is printed using one or two digits of t he 24-hour clock; for e xample, 8 for 8:00 a.m. an d 14 for 2 :00 p.m. %NN: The minute is printed using t wo digits; for exam ple, 02 for 8:02 a.m . and 48 for 2:48 p.m . %N: [...]

  • Seite 74

    67 4.7.7 Compression Click this tab and m ark the check box to en able or disable JPEG compression for data transfer from the image scanner. (This func tion is available only for Color or Gray scale scans.) This function cannot be used when [Do uble-page spread] is selected. (V9.21) Depending on the scan settings and the scanner m odel, this functi[...]

  • Seite 75

    68 4.8 Setting Advance Options The "advance dialog" is used to set items relate d to image processing. The settings apply to device-specific functions and items that differ according to whether the scanner used supports them. The advance option specification is divided into "Color Variance", "Image Processing", and &qu[...]

  • Seite 76

    69 The options are described below: 4.8.1 Gray Figure Advance dialog (Gray) ♦ Gamma Pattern This option corrects distortions from nonlinear image representation. Scanner sensors are generally designed to generate output linear to the density of the light reflected from the document. However, most output term inals do not produce output that has t[...]

  • Seite 77

    70 If the gamma pattern download file has not been re gistered in the list of file names, use the [Add] button to register the file. See "Download Pattern File" for inform ation about how to specify the file. When "Custom" is selected, a custom specification can be entered. Entering an arbitrary value between 0.1 and 10. 0 enabl[...]

  • Seite 78

    71 If [Custom Pattern 1 – 3] is selected, the following screen appears. Original Image A color sample will be shown. The dropout color can be selected by clicking the desired color with your mouse. Dropout Image An image without the dropout color will be shown. Dropout Specify up to three colors configured with [Color 1] , [Color 2], and/or [Colo[...]

  • Seite 79

    72 Sensitivity Specifies tolerance of the selected color to be dropped out. Specifiable range: 15 to 180 degrees (default: 15 degrees) Larger the value becomes, wider the color gamut is to be dropped out. [File] button Displays arbitrary image files (24-bit color bmp format) on the “Original Image”. [Apply] button Reflects the contents that hav[...]

  • Seite 80

    73 4.8.2 Image Filter Figure Advance dialog (Image Filter) ♦ Edge Processing This option specifies the sharpness of a scanned image. Select "None", "Edge Extract", "Smoothing (Backgr ound Removal)" or "Emphasis". None Edge processing is not performed. Edge Extract This option outputs an image with the edge [...]

  • Seite 81

    74 Emphasis This option outputs an image with the edge em phasized. "Emphasis High", "Emphasis Mid", or "Emphasis Low" can be selected. If "Emphasis High" is selected, the image becomes sharper. If "Emphasis Low" is selected, the image appears less distinct. * Automatic Paper Size Detection may fail[...]

  • Seite 82

    75 4.8.3 DTC This option is valid only when "DTC Variance" is set. Figure Advance dialog (DTC Mode) ♦ Scan mode This option selects one of the following two scan modes: [for OCR]: This mode is for text recognition app lications where irregularity in the image is undesirable. [for Image] : This mode is for image scanning applications tha[...]

  • Seite 83

    76 ♦ Threshold Curve This option specifies the relationship between th e threshold value and the maximum density. The specification method depends on the [ Scan mode] setting. In [for OCR] mode, use the scroll bar to set the inclination and dens ity level between 0 and 5. Click the arrow of the scroll bar or drag the scroll marker to the desired [...]

  • Seite 84

    77 ♦ Ball-Point Pen Mode When an image made with a pencil or ball-point pen is scanned, the light reflected from the pencil lead or ink is not uniform. As a resu lt, part of t he image may be missing. If the [Ball-Point Pen] checkbox is checked, filtering is applied to offset the bright area in the document and compensate for disconnected or fain[...]

  • Seite 85

    78 Figure Advance dialog (DTC Mode) <IPC-3/3D and IPC-4D installed>[...]

  • Seite 86

    79 4.8.4 When Color (/Grayscale) is specified For color scanners, when “Color” is selected in the [Image Mode], the [Advance] dialog changes as follows. And in case of some co lor scanners, when sele cting “Grayscale” the [Advance] dialog change as same as selecting “Color”. There are two image samples which are “Sam ple (before proce[...]

  • Seite 87

    80 ♦ Contrast/Brightness (Color / Grayscale) Contrast : Sets the contrast of light and shadow in a scanned image. Specify the contrast with a number in the range of 1 (low [s oft]) to 255 (high [sharp]). If this value is increased, the dark part of the image is shown darker and the light part is shown lighter. Some scanner models do not support t[...]

  • Seite 88

    81 When "Download Pattern" is selecte d, the above dialog bo x opens. Select the gamma pattern download file to be u sed from the list of file names. Then, press the [OK] button. Correction will then be executed using the selected gamma patt ern. If the gamma pattern download file has not been re gistered in the list of file names, use th[...]

  • Seite 89

    82 <Image Mode : C olor selecte d> <Ima ge Mode : Graysc ale selecte d> Figure Advance dialog ([Quality] / [Gray] tab) ♦ Image Emphasis (Color only) This option specifies the sharpness of a scanned image. Select "None", "De-Screen" or "Emphasis". None Edge processing is not performed. Emphasis This option[...]

  • Seite 90

    83 ♦ White Level Follower (Color) Select this option to scan a document who se background color is not white, such as a newspaper. Select "Auto", "Enable", or "Disable". When "Enable" is selected, the document is scanned using background follow-u p (for line drawings). When "Disable" is selected, [...]

  • Seite 91

    84 If [Custom Pattern 1 – 3] is selected, the following screen appears. Original Image A color sample will be shown. The dropout color can be selected by clicking the desired color with your mouse. Dropout Image An image without the dropout color will be shown. Dropout Specify up to three colors configured with [Color 1] , [Color 2], and/or [Colo[...]

  • Seite 92

    85 Sensitivity Specifies tolerance of the selected color to be dropped out. Specifiable range: 15 to 180 degrees (default: 15 degrees) Larger the value becomes, wider the color gamut is to be dropped out. [File] button Displays arbitrary image files (24-bit color bmp format) on the “Original Image”. [Apply] button Reflects the contents that hav[...]

  • Seite 93

    86 4.9 Setting the Setting Manager Options These options are used to manage the setting files, and switch the basic scan dialog display. Press the [Config...] button of the main dialog to open the [ Configuration] dialog box shown below. Figure Configuration dialog box ♦ Setting Files The setting information of the scan conditions can be saved in[...]

  • Seite 94

    87 ♦ FTS File Information The information of the setting file selected in [Setting Files] is displayed. ♦ [Show this dialog next open] checkbox If this checkbox is checked, [Basic Scan Dialog] will be activated the next tim e the driver is activated. ♦ [OK] button Makes the new setting valid, closes this dial og box, and returns to the main d[...]

  • Seite 95

    88 ♦ [Delete] button Deletes unnecessary setting files. Select the setting file to be deleted and then press the [Delete] button. A confirmation dialog will be displayed. Press the [OK] butto n to delete the setting file. To cancel, press the [Cancel] button. ♦ [Help] button Displays online help. ♦ [Initialization] button All of scan settings[...]

  • Seite 96

    89 4.10 Basic Scan Dialog The basic scan dialog contains only the minimum functions required for scanning. The detailed setting functions of the main dialog have been omitted. Scanning can be easily performed by selecting a registered setting file. The basic scan dialog is also useful for avoidi ng incorrect operations when standard work is perform[...]

  • Seite 97

    90 ♦ FTS File Information The contents of the selected file are displayed. ♦ [Scan] button Executes scanning based on the contents of the setting file. ♦ [OK] button Terminates without performing the scan operation. ♦ [Adjust] button Switches from the basic scan dialog to the main dialog. ♦ [Help] button Displays online help. ♦ [Show th[...]

  • Seite 98

    91 4.11 Download Pattern File The "download pattern file" of this driver is a f ile that defines the patterns to be used by the scanner to execute various image processing. This file is available in the following two versions. Each version can be selected using the [Download Selection Dialog] that opens when [Download] is selected. The fi[...]

  • Seite 99

    92 Example: In case of 8x8 matrix 8, 8, 128, 128, 128, 128 , 128, 128, 128, 128, 255, 128, 128, 128 , 128, 128, 128, 128, 255, 255, 128, 128 , 128, 128, 128, 128, 255, 255, 255, 128 , 128, 128, 128, 128, 255, 255, 255, 255 , 128, 128, 128, 128, 255, 255, 255, 255 , 255, 128, 128, 128, 255, 255, 255, 255 , 255, 255, 128, 128, 255, 255, 255, 255 , 25[...]

  • Seite 100

    93 ♦ Gamma download pattern file Any user defined gamma correction processi ng can be performed by downloading the pattern from the gamma download file to th e scanner. The defined pattern becomes effective when [Download Pattern] is selected for [Gamma Pattern]. Some models do not support this file. See "Relevant Image Scanner Specification[...]

  • Seite 101

    94 Example 256, 256, 255, 254, 253, 252 , 251, 250, 249, 248, 247, 2 46, 245, 244, 243, 242, 241, 240, 239 , 238, 237, 236, 235, 234, 2 33, 232, 231, 230, 229, 228, 227, 226 , 225, 224, 223, 222, 221, 2 20, 219, 218, 217, 216, 215, 214, 213 , 212, 211, 210, 209, 208, 2 07, 206, 205, 204, 203, 202, 201, 200 , 199, 198, 197, 196, 195, 1 94, 193, 192,[...]

  • Seite 102

    95 5. Using the Gamma Pattern Editor 5.1 Start-up Click on [Start] and select [Gamma Pattern Editor] from "Scanner Utility for Microsoft Windows" under [Programs] . The following menu is displayed: Figure Gamma Pattern Editor Tool start-up menu[...]

  • Seite 103

    96 5.2 [File] menu ♦ [Load...] This menu is used to read th e Gamma Download file and display the graph and gradations. The name of the open file is displayed above the grap h area. ♦ [Save] The gamma pattern currently being edited is saved in the file whose name is displayed above the graph area. If no filename is displa yed, the pattern is na[...]

  • Seite 104

    97 5.4 Gamma Pattern Editing ♦ Graph Area The graph area is a 256-dot x 256-dot white square area bordered by black lines, where the relationship between the input values of 0 to 2 55 ( x axis) and output values of 0 to 255 (y axis) is indicated in blue lines. Each graph dot represents one division (unit). ♦ Gradation The input is displayed in [...]

  • Seite 105

    98 6. Setting Scanner and Camera Properties 6.1 Displaying Scanner and Camera Properties Double-click the [Scanner and Camera] icon on the [Control Panel] to display th e corresponding Properties dialog box. If the scanner driver has been properly installed, the icon of your scanner is displayed. Select the model name, then double-click the icon or[...]

  • Seite 106

    99 6.3 Events Tab On the Events tab, an application can be specified to be started automatically by “Scanner events” such as “pushing buttons on the scanner”. (The Events tab is not displayed if the device does not support this function.) ♦ Select an event Select a “scanner event” from the list box to start an application. Please sele[...]

  • Seite 107

    100 In Windows ® 2000 or some scanner driver, the follo wing “ Events ” screen may be displayed. (This screen has the same function as the above screen.) ♦ Select an event Select a “scanner event” from the list box to st art an application. Please select the item to set up from the following events. " Start button " or " S[...]

  • Seite 108

    101 6.4 Diagnostic Tab To perform more detailed diagnostic tests than those provided in the general tab folder, click the [Diagnose] button. Only a user who has administrator authority can run these tests. (The Diagnostic tab is not displ ayed if the device does not support this function.)[...]

  • Seite 109

    102 6.5 Device Information Tab A list of the functions compatible with the selected scanner driver is displayed. The items displayed depend on the selected model of scanner. Only hardware functions are displayed. The functions realized by software are not displayed in this tab folder. Therefore, the displayed content may not match the content speci[...]

  • Seite 110

    103 6.6 Device Setup Tab Information related to the operation and maintena nce of the scanner driver can be displayed and set up. For some scanner models, this tab may not b e displayed, or some items cannot be set up (grayed out). Changing the setup activates the Apply button. The changed setup is reflected on the device only if the Apply button o[...]

  • Seite 111

    104 When using a scanner, the following message may be displayed. If this message appears, replace consuma b les following the instructions below. < If replacing consumables immediately > 1. Check [This message not display again.] * Skip this operation for some models, as this function is not su pported by the driver. 2. In cases where consum[...]

  • Seite 112

    105 ♦ [Power saving mode] button This specifies the power saving mode. If this button is clicked, the following dialog box is displayed. − Quick Start Mode This mode keeps the lamp on regardl ess the scanner’s operating condition, which saves times for lamp to beco me steady. − Low Power Mode To save the power consumption, this mode turns t[...]

  • Seite 113

    106 Enable (Detection Area Selection) Vertically select an area where multifeed detection will or will not be conducted. Choose either “Select area for applying Mu ltifeed Detection” or “Select area for not applying Multifeed Detection”. − Select area for applying Multifeed De tection Select an area for multifeed detection. − Select are[...]

  • Seite 114

    107 ♦ [Offset] button When this button is clicked, the fo llowing dialog box is displayed. Using this dialog box, the offset of the leading edge and magnification for the sub -scanning direction can be changed. − Offset Setting: If the position of the scanned image shifts from the original document, fine adjustment is possible. At shipment, the[...]

  • Seite 115

    108 − [OK] button The adjusted value is written to the EEPROM. * This button may not be displayed depending on the scanner model. The available settings also vary depending on the scanner model. (e.g. For fi-6130, only the setting of the ADF part can be changed) Changing this setting affects scanning oper ation of the scanner device greatly. Care[...]

  • Seite 116

    109 6.7 About Tab The version of this driver and a link to the Fujitsu home page are displayed. (The About tab is not displayed if the device does not support t his function.) (In version 10.10 or later, this tab is not displa y ed.) 6.8 Color Management Tab Color profiles assigned to the device can be added or deleted from this folder. "sRGB [...]

  • Seite 117

    110 6.9 Scanning by using “Scanner and Camera Wizard” In case of Windows ® XP / Windows Server ® 2003, you can scan by using “Scanner and Camera Wizard”. (* It functions w hen scanning with supported scanner. ) Follow below procedure to scan: 1. On the [Start] menu, select [Control Panel] – [Scanners and Cameras] . 2. Double-click on yo[...]

  • Seite 118

    111 5. Specify a file name, a format and a place to save scanned images. And click [Next] button.  Scanning starts. (The following window is displayed during scanning.) 6. Select an item of “What do you want to do?” to keep working with your picture. And click [Next] button. * Refer to Windows ® Help for detail. 7. Select “Nothing, I’m [...]

  • Seite 119

    112 8. Click [Finish] button to finish this wizard.[...]

  • Seite 120

    113 7. T roubleshooting 7.1 Error Messages 7.1.1 Messages from the TWAIN Driver • The input value is outside the range. (DS00001) Cause: A value exceedi ng the range allowed for an input item was input. R esolution: Input a value within the allowed range. Refer to the input item or the image scanner specification for the range. • The input valu[...]

  • Seite 121

    114 • The value for custom paper is higher than the m aximum sc an size. Width needs to equal 279 mm or less and length needs to equal 420 mm or less. (DS00005) • The value for custom paper is higher than th e m aximum sc an size. Width needs to equal 11 inch or less and length needs to equal 16.53 inch or less. (DS00006) • The value for cust[...]

  • Seite 122

    115 • Cannot specify Gray Scale with duplex document. (DS00011) Cause: Duplex scanning is specified with Gray Scale specified. R esolution: At duplex scanning, select Black/white binary or Half tone for the [Image type]. • Cannot specify Individual Setting with Gray Scale. (DS00012) • Cannot specify Long Page Scan with Gray Scale. (DS00017) C[...]

  • Seite 123

    116 • Description not specified. (DS00022) Cause: The description of the setti ng file has not been specified. R esolution: Enter the description of the setti ng file in the description field. Then, try scanning again. • Filename not specified. (DS00023) Cause: The filename of the setting file has not been specified. R esolution: Enter the file[...]

  • Seite 124

    117 • The specified image scanner is being used. (DS41005) Cause: The image scanner may be already in use by another application, or the TWAIN driver may have been started twice. R esolution: After all applications are te rminated, restart the image scanner for scanning. • Selected scanner is used by other application or not connected. Cause: 1[...]

  • Seite 125

    118 • No paper on ADF paper chute or Hopper. (DS32003) Cause: Although ADF was selected as the paper feeding method, no paper is found on ADF paper chute or Hopper. R esolution: Select another paper feeding method or set the document on ADF paper chute or Hopper. • The ADF is open, or No paper on ADF paper chute or Hopper. (DS32007) Cause: The [...]

  • Seite 126

    119 • Anomaly in the command for communicating with the scanner. (DS00003) • Anomaly in communication with the scanner. (DS42050) Cause: The SCSI cable is not connected firmly or is disconnected. R esolution: Confirm the cable connection. If the cable is disconnected, replace the cable with new one. If the error persists, contact the retail sto[...]

  • Seite 127

    120 • The Multifeed is detected. (DS32006) Cause: The papers are scanned with multifeeding. (One paper stuck to another) R esolution: Remove the papers stopped by multifeeding, and reset them. • Insufficient memory. (DS41001) Cause: There is not enough memory fo r tasks such as scanning and im age processing. The driver program consumes a lot o[...]

  • Seite 128

    121 • Mini Driver not found. ( DS41012) Cause: The Mini driver may not have been installed, or may have been deleted. R esolution: Install the mini-port driver following the instructions mentioned in “3.2 Installing Scanner Driver”. • Scanner DLL file not found. (DS41004) Cause: An image scanner was sele cted, but the DLL file of the select[...]

  • Seite 129

    122 • A general fault of the DAT_XXXXX, MSG_ SET, and unsupported type response. (Internally) Cause: This is a program error that us ually occurs while making the internal data settings. R esolution: Contact the place of purchase or your nearest maintenance and service center. • An undefined error occurred. (DS50006,DS50015,DS5002 4,DS50033,DS5[...]

  • Seite 130

    123 • It is about time to replace the consumable . Please replace XXXXX in paper feeder if the feeding capability is deteriorated. (DS42003)(DS42005 or DS42017)(DS4200 7)(DS42008) Cause: The consumable displayed in “XXXXX” needs to replace. R esolution: Replace the consumable disp layed in “XXXXX” as soon as possible.[...]

  • Seite 131

    124 7.1.2 Error messages relating to gamma correction pattern editing • Enter a positive decimal value. Cause: A value other than a number has been entered as the gamma correction value. Alternatively, 0 or a negative value has been entered. R esolution: Reenter a valid value. • The file could not be created. Cause: The file for saving could no[...]

  • Seite 132

    125 7.2 Device Trouble Related to Operation • The [Scan] button is pressed, but scanning is not performed. Cause: Has the scanner power been tu rned on? Has the SCSI cable been connected correctly? Has the correct device type been selected using [Select TWAIN Input Device]? • The scanner appears to be operati ng, but no image is displayed. Caus[...]

  • Seite 133

    126 7.3 Device Trouble Related to Installation • Cannot install the driver. (The installation is stopped on the wa y .) Cause: Is the older version TWAIN Driver .installed in your PC? R esolution: Please install the driver after uninstalling the old versions. • Though the PC is activated after connecting the scanner device, the scanner device i[...]

  • Seite 134

    127 8. Appendix 8.1 Relevant Image Scanner Specification Product: fi-4340C (Driver version: 9.18) Type : Desktop Image sensor : Color CCD, Reduced optical system Operating method : Document fixed Flat bed, Automatic Document Feed (ADF), Simultaneous double-sided scanning Long page scanning (216mm x 1541mm, Black & White only) Light source : Flu[...]

  • Seite 135

    128 Scanning area specification : Specified (one location) White level follower : Enabled Brightness / Threshold / Contrast : 255 steps High light / Shadow : 255 steps (at Color / Grayscale scanning) Gamma pattern : Normal / Soft / Sharp / Download Pattern / Custom Image processing function : Simplified Dynam ic Threshold (SDTC), Edge emphasis, Edg[...]

  • Seite 136

    129 Use Both Memory ( [Ram Cache]+[Use Memory on Scanner] ) function : Disabled Batch Detection : Enabled Multifeed detection : Enabled (Check thickness / length) Show Multifeed Image : Disabled Pre-Pick : Disabled Check Over-skew : Disabled Check Over-skew : Disabled Paper Protection : Disabled Blank page skip : Enabled JPEG Transfer (Hardware Com[...]

  • Seite 137

    130 Product: fi-4860C2 (Driver version: 9.18) Type : Desktop Image sensor : Reduced optical system Operating method : Automatic Document Feed (ADF), Simultaneous double-sided scanning, Long page scanning (297mm x 878mm, Black & White only) Light source : Fluorescent tube (White) Basic resolution : 400 dpi Output resolution : Monochrome: 400, 30[...]

  • Seite 138

    131 Gamma pattern : Normal / Soft / Sharp Image processing function : Dynamic Threshold (SDTC, DTC), Edge emphasis, Edge extraction, Automatic separation, Mirror image(Black & White only), 256 Color, 8 Color, 4bit Grayscale, Reverse imag e Individual setting : Enabled (Brightness / Threshold / Contrast / High light / Shadow / Gamma pattern / Im[...]

  • Seite 139

    132 Show Multifeed Image : Disabled Pre-Pick : Enabled Check Over-skew : Enabled Paper Protection : Disabled Blank page skip : Enabled JPEG Transfer (Hardware Compression) : Enabled Filter : Page Edge Filler, Digital Endorse Drop out color : Enabled sRGB output : Disabled Use Image Processing Software Option : Enabled (sold separately) Double-page [...]

  • Seite 140

    133 Product: fi-5015C (Driver version: 9.19) Type : Desktop Image sensor : Reduced optical sy stem Operating method : Document fixed Flat bed, Automatic Document Feed (ADF), Single-sided reading Light source : Fluorescent tube (White) Basic resolution : 600 dpi Output resolution 1 : 50 dpi to 600 dpi (at steps of 1dpi) Grayscale levels (internal) :[...]

  • Seite 141

    134 Individual setting : Disabled Multi Image : Disabled Imprinter (Endorse) : Disabled Interface : USB 1.1 / 2.0 Prescan : Disabled Preview : Disabled Flip Side Rotation : Disabled Rotation : Enabled Punch hole removal : Disabled Automatic Size and Skew detection : White Background Split Image : Disabled Overscan : Enabled (when “White Backgroun[...]

  • Seite 142

    135 Cropping with Carrier Sheet : Disabled <Other functions> Operator Panel setting : [Scan] / [Send to] button Device set : Consumables replace (Pad / Pick Roller counter clear) Offset setting, Power Control setting, Power saving setting Scanner and Camera Wizard : Enabled (Windows XP / Windows Server ® 2003 only)[...]

  • Seite 143

    136 Product: fi-5110C (Driver version: 9.21) Type : Desktop Image sensor : Color CCD (Reduced optical sy stem) Operating method : Automatic Document Feed (ADF), Simultaneous double- sided scanning 1 , Long page scanning: Max 216mm x 863mm Light source : Fluorescent tube (White) Basic resolution : 600 dpi Output resolution : 50 dpi to 600 dpi (at st[...]

  • Seite 144

    137 High light / Shadow : 255 steps (at Color / Grayscale scanning) Gamma pattern : Norm al / Custom / Bright Image processing function : Simplified Dynamic Threshold (SDTC), Edge em phasis, De-Screen, 256 Color, 8 Color, 4bit Grayscale, Reverse image Individual setting : Disabled Multi Image : Disabled Imprinter (Endorse) : Disabled Interface : US[...]

  • Seite 145

    138 JPEG Transfer (Hardware Compression) : Enabled Filter : Page Edge Filler, Digital Endorse Drop out color : Enabled sRGB output : Disabled Use Image Processing Software Option : Enabled (sold separately) Double-page spread with Carrier Sheet : Disabled Cropping with Carrier Sheet : Disabled <Other functions> Scanner panel setting : Enabled[...]

  • Seite 146

    139 Product: fi-5120C (Driver version: 9.21) Type : Desktop Image sensor : Color CCD (Reduced optical system) Operating method : Automatic Document Feed (ADF), Simultaneous double- sided scanning, Long page scanning : Max 216mm x864mm Light source : Fluorescent tube (White) Basic resolution : 600 dpi Output resolution : 50 dpi to 600 dpi (at steps [...]

  • Seite 147

    140 Gamma pattern : Normal / Custom / Bright Image processing function : Simplified Dyna mic Threshold (SDTC), Advanced DTC, Edge emphasis, Edge smoothing, De-Screen, 256 Color, 8 Color, 4bit Grayscale, Reverse image Individual setting : Enabled (Brightness / Threshold / Contrast / High light / Shadow / Gamma pattern) Multi Image : Disabled Imprint[...]

  • Seite 148

    141 Multifeed detection : Enabled (Check overlappin g / length, Area selection) Show Multifeed Image : Disabled Pre-Pick : Disabled Check Over-skew : Disabled Paper Protection : Disabled Blank page skip : Enabled JPEG Transfer (Hardware Compression) : Enabled Filter : Page Edge Filler, Digital Endorse Drop out color : Enabled sRGB output : Enabled [...]

  • Seite 149

    142 Product: fi-5220C (Driver version: 9.21) Type : Desktop Image sensor : Color CCD (Reduced optical sy stem) Operating method : Document fixed Flat bed (FB), Automatic Document Feed (ADF), Simultaneous double-sided scanning, Long page scanning : Max 216mm x 864mm Light source : Fluorescent tube (White) Basic resolution : 600dpi Output resolution [...]

  • Seite 150

    143 Brightness / Threshold / Contrast : 255 steps High light / Shadow : 255 steps (at Color / Gray scale scanning) Gamma pattern : Normal / Custom / Bright Image processing function : Simplified Dyna mic Threshold (SDTC), Advanced DTC, Edge emphasis, Edge smoothing, De-Screen, 256 Color, 8 Color, 4bit Grayscale, Reverse image Individual setting : E[...]

  • Seite 151

    144 Paper Protection : Disabled Blank page skip : Enabled JPEG Transfer (Hardware Compression) : Enabled Filter : Page Edge Filler, Digital Endorse Drop out color : Enabled sRGB output : Enabled Use Image Processing Software Option : Enabled (sold separately ) Double-page spread with Carrier Sheet : Disabled Cropping with Carrier Sheet : Disabled &[...]

  • Seite 152

    145 Product: fi-5530C (Driver version: 9.21) Type : Desktop Image sensor : Color CCD Operating method : Automatic Document Feed (ADF), Simultaneous double-sided scanning, Long page scanning (Resolution free) Black&White : Maximum 297mm x 864mm Grayscale, Color : Maximum 297mm x 864mm Light source : Fluorescent tube (White) Basic resolution : 60[...]

  • Seite 153

    146 Brightness / Threshold / Contrast : 255 steps High light / Shadow : 255 steps (at Color / Grayscale scanning) Gamma pattern : Normal / Custom / Bright Image processing function : Simplified Dyna mic Threshold (SDTC), Advanced DTC, Edge emphasis, Edge smoothing, De-screen, 256 color, 8 color, 4bit Grayscale, Reverse image Individual setting : En[...]

  • Seite 154

    147 Use Both Memory ( [Ram Cache]+[Use Memory on Scanner] ) function : Disabled Batch Detection : Disabled Multifeed detection : Enabled (Check overlapping / length, Area selection) Show Multifeed Image : Disabled Pre-Pick : Enabled Check Over-skew : Disabled Paper Protecti on : Disabled Blank page skip : Enabled JPEG Transfer (Hardware Compression[...]

  • Seite 155

    148 Product: fi-5530C2 (Driver version: 9.21) Type : Desktop Image sensor : Color CCD Operating method : Automatic Document Feed (ADF), Simultaneous double-sided scanning, Long page scanning (Resolution free) Black&White : Maximum 297mm x 864mm Grayscale, Color : Maximum 297mm x 864mm Light source : Fluorescent tube (White) Basic resolution : 6[...]

  • Seite 156

    149 Brightness / Threshold / Contrast : 255 steps High light / Shadow : 255 steps (at Color / Gray scale scanning) Gamma pattern : Normal / Custom / Bright Image processing function : Simplified Dyna mic Threshold (SDTC), Advanced DTC, Edge emphasis, Edge smoothing, De-screen, 256 color, 8 color, 4bit Grayscale, Reverse image Individual setting : E[...]

  • Seite 157

    150 Use Both Memory ( [Ram Cache]+[Use Memory on Scanner] ) function : Disabled Batch Detection : Disabled Multifeed detection : Enabled (Check overlapping / length, Area selection) Show Multifeed Image : Disabled Pre-Pick : Enabled Check Over-skew : Disabled Paper Protecti on : Disabled Blank page skip : Enabled JPEG Transfer (Hardware Compression[...]

  • Seite 158

    151 Product: fi-5650C (Driver version: 9.21) Type : Desktop Image sensor : Color CCD + Reduced optical sy stem Operating method : Automatic Document Feed(ADF), Simultaneous double-sided scanning Long page scanning (305mm x 864 mm) Light source : Fluorescent tube (White) Basic resolution : 600 dpi Output resolution : Standard: 50 dpi to 600 dpi (at [...]

  • Seite 159

    152 High light / Shadow : 255 steps (at Color / Gray scale scanning) Gamma pattern : Normal / Soft / Sharp / Download Pattern / Custom / Bright Image processing function : Simplified Dynamic Threshold (SDTC), Edge em phasis, Edge extraction, De-Screen, SEE (Selectable Edge Enhancement), Reverse image (at Black & White, Grayscale), 256 Color, 8 [...]

  • Seite 160

    153 Use Both Memory ( [Ram Cache]+[Use Memory on Scanner] ) function : Enabled Batch Detection : Enabled Multifeed detection : Enabled (Check overlapping / length) Show Multifeed Image : Disabled Pre-Pick : Enabled Check Over-skew : Disabled Paper Protecti on : Disabled Blank page skip : Enabled JPEG Transfer (Hardware Compression) : Enabled Filter[...]

  • Seite 161

    154 Product: fi-5750C (Driver version: 9.21) Type : Desktop Image sensor : Color CCD + Reduced optical sy stem Operating method : Document fixed Flat bed(FB), Automatic Document Feed(ADF), Simultaneous double-sided scanning Long page scanning (305mm x 864 mm) Light source : Fluorescent tube (White) Basic resolution : 600 dpi Output resolution : Sta[...]

  • Seite 162

    155 White level follower : Enabled Brightness / Threshold / Contrast : 255 steps High light / Shadow : 255 steps (at Color / Gray scale scanning) Gamma pattern : Normal / Soft / Sharp / Download Pattern / Custom / Bright Image processing function : Simplified Dynamic Threshold (SDTC), Edge em phasis, Edge extraction, De-Screen, SEE (Selectable Edge[...]

  • Seite 163

    156 Pre-Pick : Enabled Check Over-skew : Disabled Paper Protecti on : Disabled Blank page skip : Enabled JPEG Transfer (Hardware Compression) : Enabled Filter : Page Edge Filler, Digital Endorse Drop out color : Enabled sRGB output : Enabled Use Image Processing Software Option : Enabled (sold separately ) Double-page spread with Carrier Sheet : Di[...]

  • Seite 164

    157 Product: fi-5900C (Driver version: 9.21) Type : Desktop Image sensor : Reduced optical system Operating method : Automatic Document Feed (ADF), Simultaneous double-sided scanning, Long page scanning (305mm x 3175mm) 1, 2 Light source : Fluorescent tube (White) Basic resolution : 600 dpi Output resolution : Standard: 50 dpi to 600 dpi (at steps [...]

  • Seite 165

    158 Brightness / Threshold / Contrast : 255 steps High light / Shadow : 255 steps (at Color / Grayscale scanning) Gamma pattern : Normal / Soft / Sharp / Download Pattern / Custom / Bright Image processing function : Dynamic Threshold (SDTC), Advanced DTC, Edge emphasis, Edge extraction, De-Screen, SEE(Selectable Edge Enhancement), Reverse image (a[...]

  • Seite 166

    159 Split Image : Disabled Overscan : Enabled (when “Black Background” is selected) Cutting out Size : Disabled Buffer scan ([Use Memory on Scanner]) function : Enabled Use Both Memory ( [Ram Cache]+[Use Memory on Scanner] ) function : Enabled Batch Detection 1 : Enabled Multifeed detection : Enabled (Check overlapping / length) Show Multifeed [...]

  • Seite 167

    160 <Other functions> Operator Panel setting : [Scan] / [Send to] button Prefer Scanning Speed setting : Enabled Device set : Consumables replace (Pad / Pick Roller / Break Roller / Separator Roller / Remaining Ink counter clear) Offset Setting, Vertical magnification Adjustment, Power Saving setting Area Selection for Multifeed Detection[...]

  • Seite 168

    161 Product: fi-5950 (Driver version: 10.10) Type : Desktop Image sensor : Reduced optical system Operating method : Automatic Document Feed (ADF), Simultaneous double- sided scanning, Long page scanning (305mm x 3175mm) 1 Light source : Fluorescent tube (White) Basic resolution : 600 dpi Output resolution : Standard: 50 dpi to 600 dpi (at steps of[...]

  • Seite 169

    162 Gamma pattern : Normal / Soft / Sharp / Download Pattern / Custom / Bright Image processing function : Dynamic Threshold (SDTC), Advanced DTC, Edge emphasis, Edge extraction, De-Screen, SEE (Selectable Edge Enhancement), Reverse image (at Black & White, Grayscale), 256 Color, 8 Color, 4bit Grayscale Individual setting : Enabled (Image Mode [...]

  • Seite 170

    163 Use Both Memory ( [Ram Cache]+[Use Memory on Scanner] ) function : Enabled Batch Detection 1 : Enabled Multifeed detection : Enabled (Check overlapping / length) Show Multifeed Image : Disabled Pre-Pick : Enabled Check Over-skew : Enabled Paper Protection : Disabled Blank page skip : Enabled JPEG Transfer (Hardware Compression) : Enabled Filter[...]

  • Seite 171

    164 Product: fi-60F (Driver version: 9.21) Type : Desktop Image sensor : LED(RGB) + Reduced optical sy stem Operating method : Document fixed Flat bed(FB) Light source : LED (R, G, B) Basic resolution : 600 dpi Output resolution : Standard: 50 dpi to 600 dpi (at steps of 1dpi) Grayscale levels (internal) : 16 bit 65536 levels Grayscale output : Ena[...]

  • Seite 172

    165 Flip Side Rotation : Disabled Rotation : Enabled Punch hole removal : Disabled Automatic Size and Skew detection : Automatic Page Size Detection Split Image : Disabled Overscan : Disabled Cutting out Size : Disabled Buffer scan ([Use Memory on Scanner]) function : Disabled Use Both Memory ( [Ram Cache]+[Use Memory on Scanner] ) function : Disab[...]

  • Seite 173

    166 Product: fi-6110 (Driver version: 10.20) Type : Desktop Image sensor : Color CCD (Reduced optical sy stem) Operating method : Automatic Document Feed (ADF), Simultaneous do uble- sided scanning, Long page scanning : Max 216mm x3175mm 1 Light source : Fluorescent tube (White) Basic resolution : 600 dpi Output resolution : 50 dpi to 600 dpi (at s[...]

  • Seite 174

    167 Gamma pattern : Normal / Soft / Sharp / D ownload Pattern / Custom / Bright Image processing function : Simplified Dyna mic Threshold (SDTC), Advanced DTC, Edge emphasis, Edge smoothing, De-Screen, 256 Color, 8 Color, 4bit Grayscale, Reverse image Individual setting : Enabled (Brightness / Threshold / Contrast / High light / Shadow / Gamma patt[...]

  • Seite 175

    168 Use Image Processing Software Option : Enabled (sold separately ) Double-page spread with Carrier Sheet : Enabled Cropping with Carrier Sheet : Enabled <Other functions> Operator Panel setting : [Scan] / [Send to] button Prefer Scanning Speed setting : Enabled Device set : Consumables replace (Pad/ Pick Roller counter clear) Offset Settin[...]

  • Seite 176

    169 Product: fi-6130 (Driver version: 9.21) Type : Desktop Image sensor : Color CCD (Reduced optical sy stem) Operating method : Automatic Document Feed (ADF), Simultaneous do uble- sided scanning, Long page scanning : Max 216mm x3175mm 1 Light source : Fluorescent tube (White) Basic resolution : 600 dpi Output resolution : 50 dpi to 600 dpi (at st[...]

  • Seite 177

    170 Gamma pattern : Normal / Soft / Sharp / D ownload Pattern / Custom / Bright Image processing function : Simplified Dyna mic Threshold (SDTC), Advanced DTC, Edge emphasis, Edge smoothing, De-Screen, 256 Color, 8 Color, 4bit Grayscale, Reverse image Individual setting : Enabled (Brightness / Threshold / Contrast / High light / Shadow / Gamma patt[...]

  • Seite 178

    171 Paper Protecti on : Disabled Blank page skip : Enabled JPEG Transfer (Hardware Compression) : Enabled Filter : Page Edge Filler, Digital Endorse Drop out color : Enabled sRGB output : Enabled Use Image Processing Software Option : Enabled (sold separately ) Double-page spread with Carrier Sheet : Enabled Cropping with Carrier Sheet : Disabled &[...]

  • Seite 179

    172 Product: fi-6140 (Driver version: 9.21) Type : Desktop Image sensor : Color CCD (Reduced optical sy stem) Operating method : Automatic Document Feed (ADF), Simultaneous do uble- sided scanning, Long page scanning : Max 216mm x3175mm 1 Light source : Fluorescent tube (White) Basic resolution : 600 dpi Output resolution : 50 dpi to 600 dpi (at st[...]

  • Seite 180

    173 Gamma pattern : Normal / Soft / Sharp / D ownload Pattern / Custom / Bright Image processing function : Simplified D ynam ic Threshold (SDTC), De-Screen, Edge emphasis, 256 Color, 8 Color, 4bit Gray scale Individual setting : Enabled (Brightness / Threshold / Contrast / High light / Shadow / Gamma pattern) Multi Image : Multi Image Output / Aut[...]

  • Seite 181

    174 Multifeed detection : Enabled (Check overlapping / length, Area selection) Show Multifeed Image : Disabled Pre-Pick : Enabled Check Over-skew : Disabled Paper Protecti on : Enabled Blank page skip : Enabled JPEG Transfer (Hardware Compression) : Enabled Filter : Page Edge Filler, Digital Endorse Drop out color : Enabled sRGB output : Enabled Us[...]

  • Seite 182

    175 Product: fi-6230 (Driver version: 9.21) T yp e : Deskto p Ima g e senso r : Color CCD ( Reduced o p tical s y stem ) Operating method : Document fixed Flat bed (FB), Automatic Document Feed (ADF), Simultaneous double-sided scanning, Lon g p a g e scannin g : Max 216m m x 3175mm 1 Li g ht source : Fluorescent tube ( White ) Basic resolution : 60[...]

  • Seite 183

    176 Brightness / Threshold / Contrast : 255 steps High light / Shadow : 255 steps (at Color / Gray scale scanning) Gamma pattern : Normal / Soft / Sharp / D ownload Pattern / Custom / Bright Image processing function : Simplified Dyna mic Threshold (SDTC), Advanced DTC, Edge emphasis, Edge smoothing, De-Screen, 256 Color, 8 Color, 4bit Grayscale, R[...]

  • Seite 184

    177 Drop out color : Enabled sRGB output : Enabled Use Image Processing Software Option : Enabled (sold separately ) Double-page spread with Carrier Sheet : Enabled Cropping with Carrier Sheet : Disabled <Other functions> Operator Panel setting : [Scan] / [Send to] button Prefer Scanning Speed setting : Enabled Device set : Consumables replac[...]

  • Seite 185

    178 Product: fi-6240 (Driver version: 9.21) Type : Desktop Image sensor : Color CCD (Reduced optical sy stem) Operating method : Document fixed Flat bed (FB), Automatic Document Feed (ADF), Simultaneous double-sided scanning, Long page scanning : Max 216mm x 3175mm 1 Light source : Fluorescent tube (White) Basic resolution : 600dpi Output resolutio[...]

  • Seite 186

    179 Brightness / Threshold / Contrast : 255 steps High light / Shadow : 255 steps (at Color / Gray scale scanning) Gamma pattern : Normal / Soft / Sharp / Download Pattern / Custom / Bright Image processing function : Simplified Dyna mic Threshold (SDTC), Advanced DTC, Edge emphasis, Edge smoothing, De-Screen, 256 Color, 8 Color, 4bit Grayscale, Re[...]

  • Seite 187

    180 Paper Protecti on : Disabled Blank page skip : Enabled JPEG Transfer (Hardware Compression) : Enabled Filter : Page Edge Filler, Digital Endorse Drop out color : Enabled sRGB output : Enabled Use Image Processing Software Option : Enabled (sold separately ) Double-page spread with Carrier Sheet : Enabled Cropping with Carrier Sheet : Disabled &[...]

  • Seite 188

    181 Product: fi-6670/fi-6670A (Driver version: 9.21) Type : Desktop Image sensor : Color CCD + Reduced optical sy stem Operating method : Automatic Document Feed(ADF), Simultaneous double-sided scanning Long page scanning (Resolution: 400dpi or less 1 ) (305mm x 3175mm) Light source : Fluorescent tube (White) Basic resolution : 600 dpi Output resol[...]

  • Seite 189

    182 White level follower : Enabled Brightness / Threshold / Contrast : 255 steps High light / Shadow : 255 steps (at Color / Gray scale scanning) Gamma pattern : Normal / Soft / Sharp / Download Pattern / Custom / Bright Image processing function : Simplified Dynamic Threshold (SDTC), Edge em phasis, Edge extraction, De-Screen, SEE (Selectable Edge[...]

  • Seite 190

    183 Buffer scan ([Use Memory on Scanner]) function : Enabled Use Both Memory ( [Ram Cache]+[Use Memory on Scanner] ) function : Enabled Batch Detection : Enabled Multifeed detection : Enabled (Check overlapping / length) Show Multifeed Image : Disabled Pre-Pick : Enabled Check Over-skew : Disabled Paper Protecti on : Disabled Blank page skip : Enab[...]

  • Seite 191

    184 Product: fi-6750S (Driver version: 9.21) Type : Desktop Image sensor : Color CCD + Reduced optical system Operating method : Document fixed Flat bed(FB), Automatic Document Feed(ADF) Long page scanning (Resolution: 400dpi or less 1 ) (305mm x 3175mm) Light source : Fluorescent tube (White) Basic resolution : 600 dpi Output resolution : Standard[...]

  • Seite 192

    185 Image processing function : Simplified Dynam i c Threshold (SDTC), Edge emphasis, Edge extraction, De-Screen, SEE (Selectable Edge Enhancement), Reverse image (at Black & White, Gray scale), 256 Color, 8 Color, 4bit Gra y scale Individual settin g : Disabled Multi Ima g e : Multi Image Output / Auto co lor Detection Im p rinter ( Endorse ) [...]

  • Seite 193

    186 Product: fi-6770/fi-6770A (Driver version: 9.21) Type : Desktop Image sensor : Color CCD + Reduced optical sy stem Operating method : Document fixed Flat bed(FB), Automatic Document Feed(ADF), Simultaneous double-sided scanning Long page scanning (Resolution: 400dpi or less 1 ) (305mm x 3175mm) Light source : Fluorescent tube (White) Basic reso[...]

  • Seite 194

    187 White level follower : Enabled Brightness / Threshold / Contrast : 255 steps High light / Shadow : 255 steps (at Color / Gray scale scanning) Gamma pattern : Normal / Soft / Sharp / Download Pattern / Custom / Bright Image processing function : Simplified Dynamic Threshold (SDTC), Edge em phasis, Edge extraction, De-Screen, SEE (Selectable Edge[...]

  • Seite 195

    188 Filter : Page Edge Filler, Digital Endorse Drop out color : Enabled sRGB output : Enabled Use Image Processing Software Option : Enabled (included as a standard function) Double-page spread with Carrier Sheet : Disabled Cropping with Carrier Sheet : Disabled[...]

  • Seite 196

    189 Product: fi-6800 (Driver version: 10.10) Type : Desktop Image sensor : Reduced optical system Operating method : Automatic Document Feed (ADF), Simultaneous double- sided scanning, Long page scanning (305mm x 3175mm) 1 Light source : Fluorescent tube (White) Basic resolution : 600 dpi Output resolution : Standard: 50 dpi to 600 dpi (at steps of[...]

  • Seite 197

    190 Image processing function : Dynamic Threshold (SDTC), Advanced DTC, Edge emphasis, Edge extraction, De-Screen, SEE (Selectable Edge Enhancement), Reverse image, 256 Color, 8 Color, 4bit Grayscale Individual setting : Enabled (Image Mode / Brightness / Threshold / Contrast / High light / Shadow / Gamma pattern / Image processing function) Multi [...]

  • Seite 198

    191 Show Multifeed Image : Enabled Pre-Pick : Enabled Check Over-skew : Disabled Paper Protection : Enabled Blank page skip : Enabled JPEG Transfer (Hardware Compression) : Enabled Filter : Page Edge Filler, Digital Endorse Drop out color : Enabled ( Red, Green, Blue, None, Custom, Panel setting ) sRGB output : Enabled Use Image Processing Soft[...]

  • Seite 199

    192 8.2 Maintenance Service This section explains briefly how you can help us t o provide you with high-quality maintenance service. Since it is practically impossible for the Fujitsu service staff to be aware of every detail of your daily scanning operation, please understand that our staff may sometimes be unable to answer your question immediate[...]

  • Seite 200

    TWAIN Driver “Scanner Utility for Microsoft ® Windows ® ” User’s Guide <32 bit / 64bit version> First Edition August 2011 © PFU LIMITED 2011 The contents of this document m ay ch ange for improvements without prior notice. PFU LIMITED takes no responsibilities for infringements of third parties’ patents or other rights that may ste[...]