Agilent Technologies 85107B manual
- Consulta online o descarga el manual de instrucciones
- 20 páginas
- 0.51 mb
Ir a la página of
manuales de instrucciones parecidos
-
Network Hardware
Agilent Technologies 3589A
151 páginas 4.03 mb -
Network Hardware
Agilent Technologies 8510
32 páginas 0.4 mb -
Network Hardware
Agilent Technologies 85107B
20 páginas 0.51 mb -
Network Hardware
Agilent Technologies 5373A
490 páginas 12.1 mb -
Network Hardware
Agilent Technologies 1670G
632 páginas 4.6 mb -
Network Hardware
Agilent Technologies 06-296-90001
62 páginas 3.22 mb -
Network Hardware
Agilent Technologies 8510C
41 páginas 2.21 mb -
Network Hardware
Agilent Technologies 8510XF
20 páginas 0.51 mb
Buen manual de instrucciones
Las leyes obligan al vendedor a entregarle al comprador, junto con el producto, el manual de instrucciones Agilent Technologies 85107B. La falta del manual o facilitar información incorrecta al consumidor constituyen una base de reclamación por no estar de acuerdo el producto con el contrato. Según la ley, está permitido adjuntar un manual de otra forma que no sea en papel, lo cual últimamente es bastante común y los fabricantes nos facilitan un manual gráfico, su versión electrónica Agilent Technologies 85107B o vídeos de instrucciones para usuarios. La condición es que tenga una forma legible y entendible.
¿Qué es un manual de instrucciones?
El nombre proviene de la palabra latina “instructio”, es decir, ordenar. Por lo tanto, en un manual Agilent Technologies 85107B se puede encontrar la descripción de las etapas de actuación. El propósito de un manual es enseñar, facilitar el encendido o el uso de un dispositivo o la realización de acciones concretas. Un manual de instrucciones también es una fuente de información acerca de un objeto o un servicio, es una pista.
Desafortunadamente pocos usuarios destinan su tiempo a leer manuales Agilent Technologies 85107B, sin embargo, un buen manual nos permite, no solo conocer una cantidad de funcionalidades adicionales del dispositivo comprado, sino también evitar la mayoría de fallos.
Entonces, ¿qué debe contener el manual de instrucciones perfecto?
Sobre todo, un manual de instrucciones Agilent Technologies 85107B debe contener:
- información acerca de las especificaciones técnicas del dispositivo Agilent Technologies 85107B
- nombre de fabricante y año de fabricación del dispositivo Agilent Technologies 85107B
- condiciones de uso, configuración y mantenimiento del dispositivo Agilent Technologies 85107B
- marcas de seguridad y certificados que confirmen su concordancia con determinadas normativas
¿Por qué no leemos los manuales de instrucciones?
Normalmente es por la falta de tiempo y seguridad acerca de las funcionalidades determinadas de los dispositivos comprados. Desafortunadamente la conexión y el encendido de Agilent Technologies 85107B no es suficiente. El manual de instrucciones siempre contiene una serie de indicaciones acerca de determinadas funcionalidades, normas de seguridad, consejos de mantenimiento (incluso qué productos usar), fallos eventuales de Agilent Technologies 85107B y maneras de solucionar los problemas que puedan ocurrir durante su uso. Al final, en un manual se pueden encontrar los detalles de servicio técnico Agilent Technologies en caso de que las soluciones propuestas no hayan funcionado. Actualmente gozan de éxito manuales de instrucciones en forma de animaciones interesantes o vídeo manuales que llegan al usuario mucho mejor que en forma de un folleto. Este tipo de manual ayuda a que el usuario vea el vídeo entero sin saltarse las especificaciones y las descripciones técnicas complicadas de Agilent Technologies 85107B, como se suele hacer teniendo una versión en papel.
¿Por qué vale la pena leer los manuales de instrucciones?
Sobre todo es en ellos donde encontraremos las respuestas acerca de la construcción, las posibilidades del dispositivo Agilent Technologies 85107B, el uso de determinados accesorios y una serie de informaciones que permiten aprovechar completamente sus funciones y comodidades.
Tras una compra exitosa de un equipo o un dispositivo, vale la pena dedicar un momento para familiarizarse con cada parte del manual Agilent Technologies 85107B. Actualmente se preparan y traducen con dedicación, para que no solo sean comprensibles para los usuarios, sino que también cumplan su función básica de información y ayuda.
Índice de manuales de instrucciones
-
Página 1
Agilent Upgrade Guide for the 8510 V ector Network Analyzer Product Note 85107B, 45 MHz to 50 GHz in coax 8510XF on-wafer configuration 85106D with option 001, 45 MHz to 50 GHz in coax, above 50 GHz in waveguide[...]
-
Página 2
2 3 5 5 6 7 8 9 9 9 10 11 11 11 11 12 13 15 15 16 17 17 19 T able of Contents V ector network analyzer (VNA) overview Agilent 8510 family of products Agilent 8510 network analyzer Agilent 8510 firmware upgrade kits T est sets Sources Upgrade considerations Upgrading individual components Upgrading the 8510 Upgrading the 8510 to 8530 T est set upgra[...]
-
Página 3
3 Figure 1. Device characterization DUT Processor/Display Receiver/Detector Signal separation Source Incident Reflected Transmitted Incident Reflected Transmitted Figure 2. Network analyzer configuration V ector network analyzer (VNA) overview V ector network analyzer (VNA) measurement systems are used t o fully characterize the linear beha vior of[...]
-
Página 4
4 8510 VNA system Source 8360 Test set 851X Receiver/detector 8510 processor/display network analyzer Signal separation Stimulus = + + Figure 3. 8510 measurement systems are made up of modular components, the 8510 network analyzer , a test set and a compatible source. The A gilent T echnologies 8510 netw ork analyzer consists of a family of compati[...]
-
Página 5
5 Agilent 8510 network analyzer Tables 1 and 2 sho w the different features of t he 8510A, B, and C, hardware and f irmware, respectively. T able 1. Hardware revision and measurement capability Product Firmware revisions Hardware features 8510A A.02.00 • T ape drive 8510B B.03.00 to B.06.54 • T ape drive 8510C C.06.00 to present • Large color[...]
-
Página 6
6 T able 2. Firmware revision and measurement capability Revision Time domain 1 Pulse 2 Power domain Other added key features limit lines A.02.00 B.03.00 • Adapter removal calibration • Direct control of two sources B.03.11 • Direct control of up to 4 test sets B.04.00 • 40 GHz test set capability • Frequency subset calibr[...]
-
Página 7
T est Sets The t est set in a VNA measurement system is used t o separate t he inci- dent, t he ref lected, and the transmitted signals. It is also used t o conver t the RF signal t o IF (inter mediate fre- quency) signal and to pass t he IF to the receiver . Once signals are separated, their individual magnitude and phase differences can be measur[...]
-
Página 8
8 Sources The RF or micro wav e signal source in a VNA measurement system pro vides the incident signal used to stimulate the device-under -test (DUT). The DUT responds by ref lecting par t of the incident and transmitting t he remaining part. By sweeping the frequency of t he source, the frequency response of t he DUT can be deter mined. There are[...]
-
Página 9
9 Upgrade considerations There are numerous reasons for upg rading the Agilent 8510 syst em. The 8510 netw ork analyzer maint ains ex cellent per f or mance while adapting to different measurement requirements such as basic component testing, on-waf er probing, pulsed device characterization, antenna and RCS (Radar Cross Section) meas- urements. De[...]
-
Página 10
10 Upgrading the 8510 to the 8530 microwave receiver for antenna measurements Figure 7 belo w illustrates ho w the 8510C can be upg raded t o eit her an 8530A or 8530A and 8510C. F or example, to upgrade an 8510C to an 8530A, order 85395C wit h Option 111. Figure 7. 8510 to 8530 upgrade paths Agilent 85395C 2 Upgrades any 8510C to an 8530A. Retains[...]
-
Página 11
11 T est set upgrades A sing le 8510 network analyzer can be conf igured to control up to f our test sets. The operat or can switch between test sets, without reconnections, using front panel controls. This arrangement is oft en referred to as the multiple test set configuration. Each test set must be equipped with Option 001 for IF switching. Othe[...]
-
Página 12
12 Upgrading systems Figure 8 sho ws the different 8510 systems and their components. This figure is an excellent guide when upgrading systems. Figure 8. 8510 family of system solutions T o upgrade from one system to another , simply order t he pieces t hat are needed in t he new system that are currently not in the existing system, an example is s[...]
-
Página 13
13 Here is a checklist of it ems t o consider when upgrading systems: 1. Which 8510 do I have? The 8510C is recommended for the latest available measurement capabilities. • To upgrade an 8510A t o an 8510C, order 85103E. • To upgrade an 8510B t o an 8510C, order 85103F . • Make sure the appropriate options are ordered. For inst ance, order Op[...]
-
Página 14
14 Upgrades for 85107B, 85109C Upgrade consists of tw o test heads, a millimet er t est set controller , an 83621B for LO source, and rack. It does not include calibration kits or t est por t cables. E7345A upgrade to an 8510XF 85 GHz system E7355A upgrade to an 8510XF 110 GHz system The follo wing options are available f or both upg rades:[...]
-
Página 15
15 Examples of upgrade paths Figure 10. Upgrading an 85107B 50 GHz system to an 85106D waveguide system to operate in V -band (or W -band) Measurement accessories There are measurement accessories f or seven device connect or types: 7 mm, 3.5 mm, 2.92 mm, 2.4 mm, 1.85 mm, 1 mm and T ype-N. Calibration kits include standards that are required for ve[...]
-
Página 16
16 Calibration kits Error correction requires t hat t he syst ematic er rors in the measurement system be charact erized by measuring kno wn devices (st andards) ov er the frequency range of interest with the process of calibration. All calibration kits contain st andards used for this purpose. The st andards in the 3.5 mm, 2.4 mm and T ype-N calib[...]
-
Página 17
17 V erification kits V erification kits are used to verify the per formance specif ications of an 8510 system. All kits include a precision Z o airline, mismatched airline and fixed attenuators. Measured data and uncert ainties traceable t o t he U.S. National Institute of St andards and Technology (NIST) are included wit h each kit. Compliance wi[...]
-
Página 18
18 Configuration B. This cable ar rangement is for applications where the device under t est is connected between cable ends. This setup of fers more f lexibility when connecting t o t he device under t est. For 8514B/8515A/85110A test sets (3.5 mm rugged test port connectors) Cables/adapter Connector type (on device side of cable/adapter) For 3.5 [...]
-
Página 19
19 Related literature Pub. number Agilent 8510 N etwork Analyzer , Color Brochure 5091-8970E Agilent 8510 System Solutions 5965-8837E Agilent 8510 Family Network Analyzer , Configuration Guide 5091-8967E Agilent 8510 Family Network Analyzer , Data Sheet 5091-8484E Agilent 85103C/D U pgrade P ackages to the 8510C 5091-8969E Agilent 85395A/B/C and 85[...]
-
Página 20
Agilent T echnologies’ T est and Measurement Support, Services, and Assistance Agilent T echnologies aims to maximize the value you receive, while minimizing your risk and problems. W e strive to ensure that you get the test and measure- ment capabilities you paid for and obtain the support you need. Our extensive sup- port resources and services[...]