Bradford-White Corp Eco Defender manual
- Consulta online o descarga el manual de instrucciones
- 28 páginas
- 1.56 mb
Ir a la página of
manuales de instrucciones parecidos
-
Water Heater
Bradford-White Corp MITW -12 / -15
27 páginas 1.02 mb -
Water Heater
Bradford-White Corp EFR160T120
72 páginas 1.88 mb -
Water Heater
Bradford-White Corp 105-B
2 páginas 0.25 mb -
Water Heater
Bradford-White Corp M440T
28 páginas 1.4 mb -
Water Heater
Bradford-White Corp MI75S*(BN
16 páginas 0.73 mb -
Water Heater
Bradford-White Corp MII80(A)-*-**-(SF
36 páginas 1.4 mb -
Water Heater
Bradford-White Corp TGHE-1991-N(X)
80 páginas 1.66 mb -
Water Heater
Bradford-White Corp SDW2TW75T
16 páginas 0.98 mb
Buen manual de instrucciones
Las leyes obligan al vendedor a entregarle al comprador, junto con el producto, el manual de instrucciones Bradford-White Corp Eco Defender. La falta del manual o facilitar información incorrecta al consumidor constituyen una base de reclamación por no estar de acuerdo el producto con el contrato. Según la ley, está permitido adjuntar un manual de otra forma que no sea en papel, lo cual últimamente es bastante común y los fabricantes nos facilitan un manual gráfico, su versión electrónica Bradford-White Corp Eco Defender o vídeos de instrucciones para usuarios. La condición es que tenga una forma legible y entendible.
¿Qué es un manual de instrucciones?
El nombre proviene de la palabra latina “instructio”, es decir, ordenar. Por lo tanto, en un manual Bradford-White Corp Eco Defender se puede encontrar la descripción de las etapas de actuación. El propósito de un manual es enseñar, facilitar el encendido o el uso de un dispositivo o la realización de acciones concretas. Un manual de instrucciones también es una fuente de información acerca de un objeto o un servicio, es una pista.
Desafortunadamente pocos usuarios destinan su tiempo a leer manuales Bradford-White Corp Eco Defender, sin embargo, un buen manual nos permite, no solo conocer una cantidad de funcionalidades adicionales del dispositivo comprado, sino también evitar la mayoría de fallos.
Entonces, ¿qué debe contener el manual de instrucciones perfecto?
Sobre todo, un manual de instrucciones Bradford-White Corp Eco Defender debe contener:
- información acerca de las especificaciones técnicas del dispositivo Bradford-White Corp Eco Defender
- nombre de fabricante y año de fabricación del dispositivo Bradford-White Corp Eco Defender
- condiciones de uso, configuración y mantenimiento del dispositivo Bradford-White Corp Eco Defender
- marcas de seguridad y certificados que confirmen su concordancia con determinadas normativas
¿Por qué no leemos los manuales de instrucciones?
Normalmente es por la falta de tiempo y seguridad acerca de las funcionalidades determinadas de los dispositivos comprados. Desafortunadamente la conexión y el encendido de Bradford-White Corp Eco Defender no es suficiente. El manual de instrucciones siempre contiene una serie de indicaciones acerca de determinadas funcionalidades, normas de seguridad, consejos de mantenimiento (incluso qué productos usar), fallos eventuales de Bradford-White Corp Eco Defender y maneras de solucionar los problemas que puedan ocurrir durante su uso. Al final, en un manual se pueden encontrar los detalles de servicio técnico Bradford-White Corp en caso de que las soluciones propuestas no hayan funcionado. Actualmente gozan de éxito manuales de instrucciones en forma de animaciones interesantes o vídeo manuales que llegan al usuario mucho mejor que en forma de un folleto. Este tipo de manual ayuda a que el usuario vea el vídeo entero sin saltarse las especificaciones y las descripciones técnicas complicadas de Bradford-White Corp Eco Defender, como se suele hacer teniendo una versión en papel.
¿Por qué vale la pena leer los manuales de instrucciones?
Sobre todo es en ellos donde encontraremos las respuestas acerca de la construcción, las posibilidades del dispositivo Bradford-White Corp Eco Defender, el uso de determinados accesorios y una serie de informaciones que permiten aprovechar completamente sus funciones y comodidades.
Tras una compra exitosa de un equipo o un dispositivo, vale la pena dedicar un momento para familiarizarse con cada parte del manual Bradford-White Corp Eco Defender. Actualmente se preparan y traducen con dedicación, para que no solo sean comprensibles para los usuarios, sino que también cumplan su función básica de información y ayuda.
Índice de manuales de instrucciones
-
Página 1
(To be performed ONLY by qualified service providers) Save this manual for f utu re r eference Manual 47132A The Bradford White R U150L*FRN U1504S*FRN U430T*FRN U440T*FRN U4403S*FRN U4503*FRN U1XR403S*FRN ( *) Denotes Warranty Years. U130T*FRN U130S*FRN U140T*FRN U1403T*FRN U1403S*FRN U1404T*FRN U1503*FRN R[...]
-
Página 2
The Bradford White Ultra Low NOx Gas Water Heaters Page Service Procedure Introduction 3 - - - Gas Control Troubleshooting Chart 5 - - - Tools Required for Service 4 - - - Burner and Inner Door Gasket Removal, Inspection, Replacement and Installation 7 ED-I Thermopile Testing and Replacement 10 ED-II Pilot Assembly Inspection, Cleaning and Replacem[...]
-
Página 3
The Bradford White ECO-DEFENDER Safety System The Bradford White ECO-DEFENDER Safety System was designed to resist the ignition of flammable vapors that can occur outside of the water heater. In addition, the ECO-DEFENDER Safety System is designed to meet the stringent NOx emissions standards required in the South Coast Air Quality Management Distr[...]
-
Página 4
It is intended for this manual to be used by qualified service personal for the primary purpose of troubleshooting and repair of the Bradford White ECO-DEFENDER Series of water heaters. The Honeywell WV8860Q Gas Control will display error codes in the event of ab normal operation. Error codes are listed in the troubleshooting chart beginning on pag[...]
-
Página 5
Page 5 LED Sta t us Cont r ol St at us Pr obabl e Cause Servi ce Procedu re N on e (LED n ot on or f l ash in g) G a s v al v e is oper at i n g n orm al l y . Pilot fl am e m ay n ot be pres en t . C h eck f or pil ot f lam e t h r ou gh sigh t gl ass an d l ig h t if n ec e s s ar y . 1. G as v al v e i s f unc t i o ni ng no r m a l l y 2. G as [...]
-
Página 6
Page 6 LED Sta t us Contr ol St at us Probabl e Cause Ser v i ce Pr oce dur e Fi v e f l ash es an d t h ree secon d pau se. Th e r mo s ta t we ll fa ult. 1. Dam age t o t h e the rm o we ll wi r e . 2. T h erm ow el l sen sor r esi st an ce ou t of ran ge. See page 14. Si x f l ash es an d t h ree secon d pau se. Ch amber do or t em per atu re se[...]
-
Página 7
Inner Door Removal Procedure Step 1. Rotate the gas control knob to the “OFF” position. Step 2. Remove outer jacket burner access door Step 3. Inner Door Removal. a) Disconnect chamber door temperature sensor wire harness from the gas valve. b) Disconnect resettable thermal switch white wire lead (leading from gas valve). Disconnect the red wir[...]
-
Página 8
Installation of Inner Door With Gasket. WARNING Stripped fastener connections may allow for seal breach of inner door. A seal breach may result in a fire or explosion causing property damage, personal injury or death. Do not over tighten screws in steps 8, 10 and 11. If a fastener connection is stripped, contact the manufacturer listed on the water[...]
-
Página 9
Step 10. Firmly place right side inner door flange against the burner door flange and secure with two ¼” drive screws from step 3e. DO NOT OVER TIGHTEN SCREWS . Step 11. Align right side inner door to combustion chamber and verify the fastener holes of the combustion chamber are aligned with the right side inner door slotted opening. Verify seal[...]
-
Página 10
Step 1. Closed circuit testing is t he preferred method for testing thermopile. Following the lighting instruction label on the heater, proceed to light the pilot and allow to operate for three minutes. If the pilot will not stay lit, hold the pilot button (rotate the gas control knob to the pilot position, push and hold in) during this test Step 2[...]
-
Página 11
THERMOPILE REPLACEMENT Step 1. Turn off gas supply to water heater. Rotate gas control knob to the “OFF” position. Step 2. Remove outer jacket door. Step 3. Remove right side inner door and burner door per SERVICE PROCEDURE RG-I, steps 3a through 3g. Step 4 Disconnect the red thermopile wire from the wire harness and the white thermopile wire f[...]
-
Página 12
PILOT/ELECTRODE ASSEMBLY INSPECTION, CLEANING AND REPLACEMENT Step 1. Turn off gas supply to water heater. Rotate gas control knob to the “OFF” position. Step 2. Remove outer jacket door. Step 3. Remove burner and right side of inner door per SERVICE PROCEDURE ED-I, steps 3a through 3g. Step 4. Remove burner assembly from combustion chamber. St[...]
-
Página 13
IGNITER, ELECTRODE TESTING AND REPLACEMENT With the pilot not in operation (no pilot flame) you can check the igniter and electrode circuit by viewing pilot thru the sight glass located on the inner door and observing the spark action. SERVICE PROCEDURE ED -IV Igniter and Electrode Testing and Replacement Step 1. Remove outer jacket door. Step 2. R[...]
-
Página 14
Thermal Well Testing Thermal well testing Position gas control knob to the “OFF” position and disconnect thermal well harness from gas control. N Y Using a multi-meter set to the ohms setting, insert one meter probe (see caution) into center wire position of thermal well connector, insert the second probe (see caution) into either of the outsid[...]
-
Página 15
° F 012345678 9 40 2610 9 25400 24712 2404 5 23399 22771 22 163 21573 21000 20445 50 1990 6 19383 18876 1838 3 17905 17440 16 990 16553 16128 15715 60 1531 4 14925 14548 1418 0 13823 13477 13 140 12812 12494 12185 70 1188 4 11592 11308 1103 2 10763 10502 10 248 1000 9760 9 526 80 9299 9078 8862 86 53 8449 8250 8057 78 69 7685 7507 90 7333 7165 700[...]
-
Página 16
Gas Control & Thermal Well Removal From Water Heater Step 1. Turn the gas control knob to the “OFF” position. Step 2. Drain heater to a point below the gas control level. Step 3. Turn off gas supply to water heater and disconnect gas piping from gas control. Step 4. Disconnect wire harnesses and burner assembly from gas control. Step 5. Rem[...]
-
Página 17
Gas Control Assembly to Thermal Well Step 6. Reconnect wire harnesses and igniter wire to gas control per the illustration to the left. Step 7. Reconnect gas piping to gas control. Restore gas supply and check for gas leaks. Step 8. To resume operation, follow the instruction located on the lighting instruction label or the lighting instruction loc[...]
-
Página 18
Step 1. Turn the gas control knob to the “OFF” position Step 2. Disconnect the chamber sensor wire harness from the gas valve. Step 3. Remove the chamber door temperature sensor from the right side inner door (Phillips screw driver). Step 4. Make sure that the ring terminal of the chamber door temperature sensor is not touching any surface. Usi[...]
-
Página 19
At periodic intervals (not more then 6 months) a visual inspection should be made of the main burner for proper operation and to insure no debris is accumulating. Main burner should light smoothly from pilot and burn with a blue flame with a minimum of yellow tips. After 5 minutes of operation the burner screen will become radiant and the flame wil[...]
-
Página 20
Step 5. Disconnect (unscrew) manifold mount from feed line. Use a stiff brush, compressed air and/or shop vacuum to remove any debris build up from the manifold mount. Step 6. Remove main burner orifice from feed line (3/8" wrench). Inspect and clean if necessary Step 7. Remove pilot assembly, refer to SERVICE PROCEDURE ED-III for cleaning and[...]
-
Página 21
Step 1. Remove outer jacket door. Step 2. Disconnect white wire leads from resettable thermal switch. Step 3. Using a multimeter capable of measuring continuity (Ohms), place one probe of meter on one of the brass connection tabs of the resettable thermal switch, and the remaining probe on the other connection tab. Step 4. If continuity is indicate[...]
-
Página 22
SERVICE PROCEDURE ED -VII Resettable Thermal Switch Testing and Replacement RESETTABLE THERMAL SWITCH REPLACEMENT Step 1. Rotate gas control knob to the “OFF” position. Step 2. Remove outer jacket door. Step 3. Disconnect wire leads from resettable thermal switch. Step 4. Remove (2) ¼” hex drive screws from the manifold mount. Step 5. Bend t[...]
-
Página 23
SERVICE PROCEDURE ED-VIII ScreenLok Flame Arrestor Cleaning Step 1. Rotate gas control knob to the “OFF” position. Step 2. Remove outer jacket door. Step 3. Remove burner and inner door per SERVICE PROCEDURE ED-I, step 3a through 3g. Step 4. Clean ScreenLok Flame Arrestor using stiff brush, compressed air and/or shop vacuum to remove any scale [...]
-
Página 24
SERVICE PROCEDURE ED-IX Dip Tube and Anode Inspection and Replacement Page 24 Step 1. Rotate gas control knob to the “OFF” position. Step 2. Turn off cold water supply to water heater. Connect hose to drain spigot of water heater and route to an open drain. Open a nearby hot water faucet to vent heater for draining. Open drain spigot of water h[...]
-
Página 25
Step 1. Turn off water supply to water heater. Rotate gas control knob to the “OFF” position. Step 2. Turn off cold water supply to heater. Connect hose to drain spigot of water heater and route to an open drain. Open a nearby hot water faucet to vent heater for draining. Open drain spigot of hot water heater and allow heater to drain to a poin[...]
-
Página 26
1 Flue Baffle 2 Hot Water Outlet/Anode 3 Cold Water Inlet Tube 4 T&P Relief Valve 5 Thermal Well 6 Brass Drain Valve 7 Gas Valve 8 Main Burner Orifice 9 Heat Trap Inlet 10 Heat Trap Outlet 11 Outer Door 12 Draft Diverter 13 Complete Burner Assembly 14 RN Burner and Door 15 Flexible Gas Feed Line 16 Pilot Assembly 17 Screw #8-18 x ½ Hex Washer [...]
-
Página 27
27[...]
-